Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Confidence interval”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Gaussian Process for Flight Delay Prediction: Learning a Stochastic Process

This paper presents a machine-learning approach to predict flight delays. Whereas neural networks are extensively studied for predictive capabilities, they involve non-intuitive design and extensive analysis, particularly in training and optimization processes. Instead, the proposed framework employs Gaussian Processes as a supervised learning technique for flight delay prediction. This data-driven approach trains the model using prior information, specifically the mean and covariance tied to existing data. The proposed Gaussian Process Regression (GPR) model employs the day of flight as a pivotal feature for delay forecasting. We analyze flights from various routes and gauge the accuracy of the presented learning technique by comparing the predicted delays with the actual ones. Given the inherent challenges in precisely forecasting delays, we predict the delays with a 95 % confidence interval. Also, an error propagation analysis in the prediction horizon is carried out to determine the optimal time frame for prediction. The proposed method for flight delay prediction is important as airlines can strategize flight operations and issue timely advisories.

stochastic↗

Helicopter and Urban Air Mobility (UAM) Laboratory Comparison (HULC) Psychoacoustic Test

The Helicopter and Urban Air Mobility (UAM) Laboratory Comparison (HULC) psychoacoustic test was conducted in July 2025 to compare human annoyance responses to noise from UAM vehicles and helicopters. This document provides a literature review, describes the HULC test methodology including stimuli selection and test administration procedures, and presents results from an initial analysis using multilevel statistical modeling. The test utilized 123 sound stimuli from four helicopters and six UAM vehicles across three flight phases (departure, cruise, and approach), presented to 40 subjects in the Exterior Effects Room (EER) at NASA's Langley Research Center. Subjects rated their annoyance on a 0 to 10 scale while imagining hearing these sounds multiple times daily near their homes. Key findings revealed that, at the same A-weighted sound exposure levels, UAM vehicles and helicopters produced similar annoyance responses across all flight phases, with mean differences of only approximately 1 dB and overlapping confidence intervals. However, at equivalent observer distances, UAM vehicles had inherently quieter operations and lower mean annoyance ratings. These results suggest that UAM vehicles and helicopters may be assessed in a similar manner for community noise impact. The quieter noise characteristics of UAM vehicles may provide advantages for operating in communities and integrating into urban environments.

psychoacoustics↗

Precision Interval Estimation of the Response Surface by Means of an Integrated Algorithm of Neural Network and Linear Regression

The integration of Radial Basis Function Networks and Back Propagation Neural Networks with the Multiple Linear Regression has been accomplished to map nonlinear response surfaces over a wide range of independent variables in the process of the Modem Design of Experiments. The integrated method is capable to estimate the precision intervals including confidence and predicted intervals. The power of the innovative method has been demonstrated by applying to a set of wind tunnel test data in construction of response surface and estimation of precision interval.

Lo, Ching F.↗

Saskatoon M. F. Radar System: (52 Deg N, 107 Deg W), Canada

The system runs continuously, producing 1-h profiles approx. 75 to 110 km, 1978 to 1983: in particular for the 30-d (Nov. 9 to Dec. 7), 10-d (Nov. 16 to 26), 4-d core periods (Nov. 19 to 23). The means (EW, NS) and fourier components (24-, 12-h) fitted for the 4-d are shown. s.d. are shown, as derived from four 24-h fits in the interval. Comparisons with the 10-, 30-d intervals confirm confidence in these data and the lack of major variability in November. The 1-h profiles are means of 12 profiles so intrinsic errors are minimal. The 4-, 10-d fourier fits are compared and also the 30-d means from 48-h fits; in these amplitudes are N2+E2 as N/E approx. 1. Means differ slightly due to planetary wave activity; 24-h tides are variable in Novembers; and the 12-h variation is small less than 80 km. The final figure is a high resolution spectra for the November month: the 12-, 24-h dominate; the 8-h appears less than 100 km; and up to 90 km there is a 4-d oscillation.

Manson, A. H.↗

Gender not a factor for altitude decompression sickness risk

INTRODUCTION: Early, retrospective reports of the incidence of altitude decompression sickness (DCS) during altitude chamber training exposures indicated that women were more susceptible than men. We hypothesized that a controlled, prospective study would show no significant difference. METHODS: We conducted 25 altitude chamber decompression exposure profiles. A total of 291 human subjects, 197 men and 94 women, underwent 961 exposures to simulated altitude for up to 8 h, using zero to 4 h of preoxygenation. Throughout the exposures, subjects breathed 100% oxygen, rested or performed mild or strenuous exercise, and were monitored for precordial venous gas emboli (VGE) and DCS symptoms. RESULTS: No significant differences in DCS incidence were observed between men (49.5%) and women (45.3%). However, VGE occurred at significantly higher rates among men than women under the same exposure conditions, 69.3% and 55.0% respectively. Women using hormonal contraception showed significantly greater susceptibility to DCS than those not using hormonal contraception during the latter two weeks of the menstrual cycle. Significantly higher DCS incidence was observed in the heaviest men, in women with the highest body fat, and in subjects with the highest body mass indices and lowest levels of fitness. CONCLUSION: No differences in altitude DCS incidence were observed between the sexes under our test conditions, although men developed VGE more often than women. Age and height showed no significant influence on DCS incidence, but persons of either sex with higher body mass index and lower physical fitness developed DCS more frequently.

NASA Discipline Environmental Health↗

Impact of lossy compression on diagnostic accuracy of radiographs for periapical lesions

OBJECTIVES: The purpose of this study was to evaluate the lossy Joint Photographic Experts Group compression for endodontic pretreatment digital radiographs. STUDY DESIGN: Fifty clinical charge-coupled device-based, digital radiographs depicting periapical areas were selected. Each image was compressed at 2, 4, 8, 16, 32, 48, and 64 compression ratios. One root per image was marked for examination. Images were randomized and viewed by four clinical observers under standardized viewing conditions. Each observer read the image set three times, with at least two weeks between each reading. Three pre-selected sites per image (mesial, distal, apical) were scored on a five-scale score confidence scale. A panel of three examiners scored the uncompressed images, with a consensus score for each site. The consensus score was used as the baseline for assessing the impact of lossy compression on the diagnostic values of images. The mean absolute error between consensus and observer scores was computed for each observer, site, and reading session. RESULTS: Balanced one-way analysis of variance for all observers indicated that for compression ratios 48 and 64, there was significant difference between mean absolute error of uncompressed and compressed images (P <.05). After converting the five-scale score to two-level diagnostic values, the diagnostic accuracy was strongly correlated (R (2) = 0.91) with the compression ratio. CONCLUSION: The results of this study suggest that high compression ratios can have a severe impact on the diagnostic quality of the digital radiographs for detection of periapical lesions.

NASA Discipline Space Human Factors↗

Evaluation of three portable samplers for monitoring airborne fungi

Airborne fungi were monitored at five sample sites with the Burkard portable, the RCS Plus, and the SAS Super 90 air samplers; the Andersen 2-stage impactor was used for comparison. All samplers were calibrated before being used simultaneously to collect 100-liter samples at each site. The Andersen and Burkard samplers retrieved equivalent volumes of airborne fungi; the SAS Super 90 and RCS Plus measurements did not differ from each other but were significantly lower than those obtained with the Andersen or Burkard samplers. Total fungal counts correlated linearly with Cladosporium and Penicillium counts. Alternaria species, although present at all sites, did not correlate with total count or with amounts of any other fungal genera. Sampler and location significantly influenced fungal counts, but no interactions between samplers and locations were found.

NASA Center JSC↗

Efficacy of anticoagulation in resolving left atrial and left atrial appendage thrombi: A transesophageal echocardiographic study

BACKGROUND: Transesophageal echocardiography (TEE) is the gold standard for evaluation of the left atrium and the left atrial appendage (LAA) for the presence of thrombi. Anticoagulation is conventionally used for patients with atrial fibrillation to prevent embolization of atrial thrombi. The mechanism of benefit and effectiveness of thrombi resolution with anticoagulation is not well defined. METHODS AND RESULTS: We used a TEE database of 9058 consecutive studies performed between January 1996 and November 1998 to identify all patients with thrombi reported in the left atrium and/or LAA. One hundred seventy-four patients with thrombi in the left atrial cavity (LAC) and LAA were identified (1.9% of transesophageal studies performed). The incidence of LAA thrombi was 6.6 times higher than LAC thrombi (151 vs 23, respectively). Almost all LAC thrombi were visualized on transthoracic echocardiography (90.5%). Mitral valve pathology was associated with LAC location of thrombi (P <.0001), whereas atrial fibrillation or flutter was present in most patients with LAA location of thrombi. Anticoagulation of 47 +/- 18 days was associated with thrombus resolution in 80.1% of the patients on follow-up TEE. Further anticoagulation resulted in limited additional benefit. CONCLUSIONS: LAC thrombi are rare and are usually associated with mitral valve pathology. Transthoracic echocardiography is effective in identifying these thrombi. LAA thrombi occur predominantly in patients with atrial fibrillation or flutter. Short-term anticoagulation achieves a high rate of resolution of LAA and LAC thrombi but does not obviate the need for follow-up TEE.

NASA Discipline Cardiopulmonary↗

An efficient approach to ARMA modeling of biological systems with multiple inputs and delays

This paper presents a new approach to AutoRegressive Moving Average (ARMA or ARX) modeling which automatically seeks the best model order to represent investigated linear, time invariant systems using their input/output data. The algorithm seeks the ARMA parameterization which accounts for variability in the output of the system due to input activity and contains the fewest number of parameters required to do so. The unique characteristics of the proposed system identification algorithm are its simplicity and efficiency in handling systems with delays and multiple inputs. We present results of applying the algorithm to simulated data and experimental biological data In addition, a technique for assessing the error associated with the impulse responses calculated from estimated ARMA parameterizations is presented. The mapping from ARMA coefficients to impulse response estimates is nonlinear, which complicates any effort to construct confidence bounds for the obtained impulse responses. Here a method for obtaining a linearization of this mapping is derived, which leads to a simple procedure to approximate the confidence bounds.

Non-NASA Center↗

Demonstration of Deployment Accuracy of the Starshade Inner Disk Subsystem

We present experimental results that demonstrate the required in-plane deployment accuracy of the starshade Inner Disk Subsystem (IDS). This effort was to address Milestone 7C of the Starshade Technology Activity S5, which requires that the in-plane deployment accuracy of the petal interfaces on the IDS be within +/-300um. A full-scale 10m-diameter IDS prototype was constructed. This prototype comprised a medium-fidelity perimeter truss, medium-fidelity spokes, and a low-fidelity optical shield (OS). The testbed also included gravity compensation systems and a laser tracker metrology system. The post-processed measurement uncertainties of the laser tracker were less than 30um at the 3 sigma level. Design, engineering and fabrication of these components was done by JPL, Tendeg, and Roccor. Testing was performed at the Tendeg facility in Louisville, Colorado. The IDS prototype was deployed 22 times and the locations of petal interfaces on the IDS were measured after each deployment. Based on this data, tolerance intervals were calculated that would contain 99.73% of future deployment accuracy errors with 90% confidence. These tolerance intervals are conservative estimates for 3 sigma bounds. The tolerance intervals for the three pertinent error components were found to be within the required allocations, with at least 19% margin.

Turse, Dana↗

Strain Gauge Balance Uncertainty Analysis at NASA Langley: A Technical Review

This paper describes a method to determine the uncertainties of measured forces and moments from multi-component force balances used in wind tunnel tests. A multivariate regression technique is first employed to estimate the uncertainties of the six balance sensitivities and 156 interaction coefficients derived from established balance calibration procedures. These uncertainties are then employed to calculate the uncertainties of force-moment values computed from observed balance output readings obtained during tests. Confidence and prediction intervals are obtained for each computed force and moment as functions of the actual measurands. Techniques are discussed for separate estimation of balance bias and precision uncertainties.

John S Tripp↗

Uncertainty Analysis of Inertial Model Attitude Sensor Calibration and Application with a Recommended New Calibration Method

Statistical tools, previously developed for nonlinear least-squares estimation of multivariate sensor calibration parameters and the associated calibration uncertainty analysis, have been applied to single- and multiple-axis inertial model attitude sensors used in wind tunnel testing to measure angle of attack and roll angle. The analysis provides confidence and prediction intervals of calibrated sensor measurement uncertainty as functions of applied input pitch and roll angles. A comparative performance study of various experimental designs for inertial sensor calibration is presented along with corroborating experimental data. The importance of replicated calibrations over extended time periods has been emphasized; replication provides independent estimates of calibration precision and bias uncertainties, statistical tests for calibration or modeling bias uncertainty, and statistical tests for sensor parameter drift over time. A set of recommendations for a new standardized model attitude sensor calibration method and usage procedures is included. The statistical information provided by these procedures is necessary for the uncertainty analysis of aerospace test results now required by users of industrial wind tunnel test facilities.

Tripp, John S.↗

Measures of measurement adequacy

The adequacy of a measurement instrument is often characterized in terms of the precision, accuracy, and confidence that can be assigned to the measurements that it produces. The accuracy of the measurement may be defined as the size of the difference between the true and measured values. The precision of the system over a large number of measurements may be defined in terms of the sample standarad deviation. The confidence in an interval-values measurement may be defined as the probability that this interval contains the true value. These concepts are discussed in terms of their mathematical solutions.

Source record↗

Search for extinct natural radioactivity of Pb205 via thallium-isotope anomalies in chondrites and lunar soil.

Thallium and Pb204 contents were determined by stable-isotope-dilution analysis in 16 chondrites, one achondrite, and Apollo 11 and 12 lunar fines. Meteoritic thallium contents vary over a large range, 0.02 to 100 ppb, corresponding to the fact that thallium is a highly fractionated volatile element. Lunar thallium contents are less than 5 ppb. The Tl205/Tl203 ratio was determined in most of the samples, with precision ranging from 0.03% to several percent depending mainly on the amount of thallium present. No variations from the terrestrial ratio were observed. The chondritic isochron slope for Pb205 (13.8-m.y. half-life) is less than or equal to 0.00009 (99% confidence level), corresponding to an interval of at least 60 m.y. and possibly exceeding 120 m.y. between the termination of s-process nucleosynthesis and the lead-thallium fractionations.

Huey, J. M.↗

Statistical Sampling of Tide Heights Study

The goal of the study was to determine if it was possible to reduce the cost of verifying computational models of tidal waves and currents. Statistical techniques were used to determine the least number of samples required, in a given situation, to remain statistically significant, and thereby reduce overall project costs. Commercial, academic, and Federal agencies could benefit by applying these techniques, without the need to 'touch' every item in the population. For example, the requirement of this project was to measure the heights and times of high and low tides at 8,000 locations for verification of computational models of tidal waves and currents. The application of the statistical techniques began with observations to determine the correctness of submitted measurement data, followed by some assumptions based on the observations. Among the assumptions were that the data were representative of data-collection techniques used at the measurement locations, that time measurements could be ignored (that is, height measurements alone would suffice), and that the height measurements were from a statistically normal distribution. Sample means and standard deviations were determined for all locations. Interval limits were determined for confidence levels of 95, 98, and 99 percent. It was found that the numbers of measurement locations needed to attain these confidence levels were 55, 78, and 96, respectively.

Source record↗

Decision-related cortical potentials during an auditory signal detection task with cued observation intervals

Cortical-evoked potentials were recorded from human subjects performing an auditory detection task with confidence rating responses. Unlike earlier studies that used similar procedures, the observation interval during which the auditory signal could occur was clearly marked by a visual cue light. By precisely defining the observation interval and, hence, synchronizing all perceptual decisions to the evoked potential averaging epoch, it was possible to demonstrate that high-confidence false alarms are accompanied by late-positive P3 components equivalent to those for equally confident hits. Moreover the hit and false alarm evoked potentials were found to covary similarly with variations in confidence rating and to have similar amplitude distributions over the scalp. In a second experiment, it was demonstrated that correct rejections can be associated with a P3 component larger than that for hits. Thus it was possible to show, within the signal detection paradigm, how the two major factors of decision confidence and expectancy are reflected in the P3 component of the cortical-evoked potential.

Squires, K. C.↗

Computation of the intervals of uncertainties about the parameters found for identification

A modeling method to calculate the intervals of uncertainty for parameters found by identification is described. The region of confidence and the general approach to the calculation of these intervals are discussed. The general subprograms for determination of dimensions are described. They provide the organizational charts for the subprograms, the tests carried out and the listings of the different subprograms.

Mereau, P.↗

GCR Environmental Models III: GCR Model Validation and Propagated Uncertainties in Effective Dose

This is the last of three papers focused on quantifying the uncertainty associated with galactic cosmic rays (GCR) models used for space radiation shielding applications. In the first paper, it was found that GCR ions with Z>2 and boundary energy below 500 MeV/nucleon induce less than 5% of the total effective dose behind shielding. This is an important finding since GCR model development and validation have been heavily biased toward Advanced Composition Explorer/Cosmic Ray Isotope Spectrometer measurements below 500 MeV/nucleon. Weights were also developed that quantify the relative contribution of defined GCR energy and charge groups to effective dose behind shielding. In the second paper, it was shown that these weights could be used to efficiently propagate GCR model uncertainties into effective dose behind shielding. In this work, uncertainties are quantified for a few commonly used GCR models. A validation metric is developed that accounts for measurements uncertainty, and the metric is coupled to the fast uncertainty propagation method. For this work, the Badhwar-O'Neill (BON) 2010 and 2011 and the Matthia GCR models are compared to an extensive measurement database. It is shown that BON2011 systematically overestimates heavy ion fluxes in the range 0.5-4 GeV/nucleon. The BON2010 and BON2011 also show moderate and large errors in reproducing past solar activity near the 2000 solar maximum and 2010 solar minimum. It is found that all three models induce relative errors in effective dose in the interval [-20%, 20%] at a 68% confidence level. The BON2010 and Matthia models are found to have similar overall uncertainty estimates and are preferred for space radiation shielding applications.

Slaba, Tony C.↗