Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Conduction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Mechanically robust and superior conductive n-type polymer binders for high-performance micro-silicon anodes in lithium-ion batteries

Compared with nanostructured silicon (Si), the Si microparticle (SiMP) has more commercial prospects due to its low cost. However, SiMPs suffer from unavoidable fracture during electrochemical cycling owing to their significant volume change. Here we develop a series of novel n-type conductive polymer binders (CPBs) for SiMP anodes in lithium-ion batteries owing to their superior properties. Extraordinary electrochemical performance of cells with such unique binders could be achieved, which is because these designed polymers contain electron-withdrawing oxadiazole ring groups and easily ionizable sulfonate polar groups, exhibiting excellent ionic conductivity, outstanding wettability to the electrolyte, and improved electronic conductivity after doping. Moreover, the coexistence of rigid and flexible chains enables them to have exceptional strength and ductility. Besides, a unique electrochromic approach has been utilized to investigate the energy gap of the CPBs in n-doping states. The ionic and electronic conductivities of prepared CPBs in an eigenstate and n-doping state have been systematically studied by the electrochemical method, filling the current research gap in this field. Due to the high conductivity of b-POD, the capacity of SiMPs (4200 mA h g –1 ) can be almost entirely released during the first cycle of discharge, while the SiMP anodes prepared with the PAALi or CMC binder show a much lower initial capacity. Here, the high conductivity of b-POD also endows it with better cycling performance than non-conductive binders especially at high current densities, demonstrating its excellent fast-charging ability. More essentially, this work provides polymer binders without any intricate structural designs to obtain high-performance SiMP batteries, significantly enhancing their practical applications.

25 ENERGY STORAGE↗

Effects of Al concentration on the structure and conductivity of lithium lanthanum zirconium oxide

Cubic Li 7-3x Al x La 3 Zr 2 O 12 (LLZO) is a promising, next-generation solid electrolyte due to its stability with Li-metal and high bulk conductivity (~1 mS cm -1 ). However, the source of the high conductivity is not completely understood. In this work, we address this key knowledge gap through the integration of elemental analysis, neutron diffraction sensitive to Li and O atoms, and impedance spectroscopy to understand the structure–property correlations for LLZO. We show the metal–oxygen framework structure remains constant with variation in Al substitution, resulting in a constant activation energy of ~0.35 eV and little effect on the bulk conductivity. Instead, Li concentration, Al blocking and trapping of mobile defects, and Li–Li nearest neighbor interactions largely control the Al substituted LLZO bulk conductivity, resulting in decreases from 0.73 to 0.22 mS cm -1 as the Al concentration increases from 0.17 to 0.32 mol. These results differ from those of Ta substituted LLZO, where the framework structure and Li–Li site distances play large roles in controlling the conductivity. The increased understanding of the controlling factors of conductivity allows for greater ability to tailor the design of and substitution into the LLZO structure for improved conductivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of surface functional groups on MXene conductivity

In this work, we report the in-plane electron transport in the MXenes (i.e., within the MXene layers) as a function of composition using the density-functional tight-binding method, in conjunction with the non-equilibrium Green’s functions technique. Our study reveals that all MXene compositions have a linear relationship between current and voltage at lower potentials, indicating their metallic character. However, the magnitude of the current at a given voltage (conductivity) has different trends among different compositions. For example, MXenes without any surface terminations (Ti 3 C 2 ) exhibit higher conductivity compared to MXenes with surface functionalization. Among the MXenes with –O and –OH termination, those with –O surface termination have lower conductivity than the ones with –OH surface terminations. Interestingly, conductivity changes with the ratio of –O and –OH on the MXene surface. Our calculated I–V curves and their conductivities correlate well with transmission functions and the electronic density of states around the Fermi level. The surface composition-dependent conductivity of the MXenes provides a path to tune the in-plane conductivity for enhanced pseudocapacitive performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Phonon Olympics: Phonon property and lattice thermal conductivity benchmarking from open-source packages

Three widely used open-source packages for determining phonon properties and lattice thermal conductivities (ALAMODE, phono3py, and ShengBTE) are benchmarked by teams of expert users and the package developers. The phonons for Ge, RbBr, monolayer MoSe 2 , and AlN are modeled at zero temperature, and they scatter through three-phonon and phonon-isotope processes, with thermal conductivities obtained from the linearized Peierls–Boltzmann transport equation with input from density functional theory calculations. Over a wide range of temperatures, the thermal conductivities calculated by the teams fall within at most ±15% of their mean values for each of the four materials. The phonon frequencies, obtained from the harmonic force constants, do not show large differences between the calculations, indicating that the modal heat capacities and group velocities are not responsible for the thermal conductivity variations. It is the lifetimes associated with three-phonon scattering, obtained from the cubic force constants, that drive the variations. The many decisions required to calculate the cubic force constants (e.g., supercell size, atomic displacement, neighbor cutoff, and application of symmetries) make identification of the precise origin of the thermal conductivity variations challenging. The calculated thermal conductivities do not generally show agreement with experimental measurements, which is attributed to the limitations of the density functional theory calculations. Guidance for the development of best practices is provided, which will help to standardize protocols needed for building thermal conductivity databases. The results provide a baseline for future benchmarking of other packages and more advanced calculations.

McGaughey, Alan J. H. [Carnegie Mellon Univ., Pitt↗

The effect of relative humidity and temperature on the response of stomatal conductance to vapor pressure deficit in tropical trees

Understanding how leaf gas exchange responds to changes in vapor pressure deficit (VPD) is key to predicting tropical forest resilience to climate change. Stomata regulate leaf water and CO2 diffusion, and respond to changes in temperature and relative humidity (RH), two drivers of VPD. At high temperatures, the cuticular pathway may also become significant and participate in the overall leaf conductance. Here, we measured gas exchange under light and dark conditions to investigate the stomatal and cuticular responses to temperature and RH on detached branches in five tropical tree species. Leaf conductance in the dark, when stomata are essentially closed, was not markedly impacted by temperature and RH, suggesting a minimal response of the cuticular pathway to these conditions. We compared six steady-state conductance models incorporating different effects of photosynthesis and evaporative demand on stomatal control. All models performed well (residual standard deviation, σ, < 0.025 mol m-2 s-1), but the best-fitting model (σ = 0.017 mol m-2 s-1) used a nonlinear relationship between photosynthesis and stomatal conductance and incorporated RH rather than vapor pressure difference. All models overestimated the steady-state conductance at high RH. Furthermore, leaf conductance immediately increased after a decrease in RH (wrong-way response), but not after an increase in leaf temperature. This suggests that the mechanisms underlying stomatal response to VPD need further investigation. The non-linear coupling between photosynthetic rate and stomatal conductance indicates a sharper physiological response than previously acknowledged.

Lamour, Julien↗

Radiant Heat Transfer to Absorbing Gases Enclosed Between Parallel Flat Plates with Flow and Conduction

An analysis is presented for obtaining two-dimensional temperature profiles and heat transfer in a radiation-absorbing gray gas of uniform absorptivity under the combined influence of thermal radiation, conduction, and gas flow. The gas is enclosed in a channel of infinite width and finite length formed by two semi-infinite parallel flat plates. These plates are black emitting surfaces, and the ends of the channel are formed by porous black surfaces through which the gas can flow into or out of the channel. These porous black end surfaces are used to simulate the radiation environment external to the channel. First, results are obtained for heat transfer between the plates in the absence of both conduction and flow. These results are found to be in good agreement with those obtained for the same conditions by previous workers. Results are then presented for heat transfer between the plates for the case of a radiating and conducting, but stagnant, gas separating the plates. The effects of the interactions between radiation and conduction are discussed. It was found that the heat transfer for combined radiation and conduction in an absorbing gas is slightly greater than the sum for each process taken separately. Finally, results are given for heat transfer from the plates to a flowing, radiating gas in the absence of conduction. The two plates are at the same temperature, and the gas enters the channel with uniform velocity and temperature. The results obtained for this case indicate that the heat transferred to the flowing gas from the constant temperature surfaces goes through a maximum as the absorptivity of the gas increases. This is in qualitative agreement with earlier results obtained by other investigators. All the results are presented in terms of dimensionless parameters, for the sake of generality, and the derivation of the dimensionless parameters, which are indicative of the effects of conduction and flow is presented.

Gray Gas↗

Electrically Conductive Paints for Satellites

A program was conducted to develop and test electrically conductive paint coatings for spacecraft. A wide variety of organic and inorganic coatings were formulated using conductive binders, conductive pigments, and similar approaches. Z-93, IITRI's standard specification inorganic thermal control coating, exhibits good electrical properties and is a very space-stable coating system. Several coatings based on a conductive pigment (antimony-doped tin oxide) in silicone and silicate binders offer considerable promise. Paint systems using commercially available conductive polymers also appear to be of interest, but will require substantial development. Evaluations were made based on electrical conductivity, paint physical properties, and the stability of spectral reflectance in space environment testing.

Gilligan, J. E.↗

Conductive damping of coronal motions

Time-dependent motions in the solar corona are subject to modification through conductive transport of thermal energy away from compression regions and into rarefaction regions. The evolution depends on how the energy is introduced - by an essentially thermal perturbation or by a density perturbation. The net effect of thermal conduction is to convert local kinetic energy in the transient into widely distributed thermal energy, which then may in turn be partially converted into kinetic energy of the bulk flow. Local motion in the transient is thereby damped. These effects are modeled here using a numerical solution of the time-dependent solar wind equations for single-fluid thermally conductive flow. The simulations of transient phenomena are made for ordinary collisional thermal conduction and compared with similar simulations done using polytropic flow. Between one and five solar radii, the gross character in the two cases is very similar. However, there are effects with thermal conduction that cannot be modeled with polytropic flow, illustrated here by temperature and velocity forerunners and a delayed and large-amplitude trailing velocity low. If thermal conduction is artificially inhibited by simple reduction of the thermal conduction coefficient, relative velocity amplitudes remain larger in approximate proportion to the amount the coefficient is reduced.

Suess, S. T.↗

Thermal conductivity of pristine and brominated P-100 fibers

Thermal conductivity of brominated and pristine Union Carbide P-100 graphite fibers in the 30 to 160 C temperature range was determined by measuring thermal conductivities of graphite fiber epoxy composite samples and then excluding the epoxy contribution. A comparative thermal conductivity instrument was used to measure the thermal conductivity of the samples containing fibers. Results showed that the thermal conductivity values were 225 to 370 w/m-K and 215 to 340 w/m-K for pristine and brominated fibers, respectively. Furthermore, the thermal conductivity ratio of brominated to pristine P-100 fibers was 0.89, 0.91, and 0.92 at 55 to 80 C; 108 and 130 C, respectively. Such decrease in thermal conductivity results almost entirely from the 10 percent increase in fiber cross sectional area due to bromination. This result suggests that bromination effects on P-100 fiber structure is small, and that some structural changes, presumably the sharp-angled domain wall becomes less sharp, occurring in the 80 to 108 C temperature range.

Hung, C. C.↗

Stratospheric conductivity variations over thunderstorms

This paper reports the first in-situ observation of variations in the electrical conductivity over thunderstorms at 26 km altitude. The vector electric field, positive and negative polar conductivity, and optical lightning power/flash were measured by payloads on superpressure balloons in the Southern Hemisphere in early 1984. It is found that in 72 percent of the thunderstorm periods observed (or in 23 of 32 periods) there were clear cases of conductivity variations while the balloons were over the thunderstorms. Examples from two separate balloons at widely separated dates and locations showing both daytime and nighttime events are presented. The conductivity measurements are made with the relaxation technique, and the vector field measurements are based on the double Langmuir probe high-impedance method. It is found that the positive and negative conductivity measurements vary independently and have a different temporal profile than the dc electric field. The polar conductivity variations can exceed a factor of 2 at this altitude. In seven of the nine most intense thunderstorm events the total conductivity increased, while in only one of these nine events did it decrease (one event had no change). Implications of these observations for global current patterns are discussed.

Holzworth, R. H.↗

Thermal conductivity of pristine and brominated highly graphitized pitch based carbon fibers

Thermal conductivity of brominated and pristine Union Carbide P-100 graphite fibers in the 30 to 160 C temperature range was determined by measuring thermal conductivities of graphite fiber epoxy composite samples and then excluding the epoxy contribution. A comparative thermal conductivity instrument was used to measure the thermal conductivity of the samples containing fibers. Results showed that the thermal conductivity values were 225 to 370 w/m-K and 215 to 340 w/m-K for pristine and brominated fibers, respectively. Furthermore, the thermal conductivity ratio of brominated to pristine P-100 fibers was 0.89, 0.91, and 0.92 at 55 to 80 C; 108 and 130 C, respectively. Such decrease in thermal conductivity results almost entirely from the 10 percent increase in fiber cross sectional area due to bromination. This result suggests that bromination effects on P-100 fiber structure is small, and that some structural changes, presumably the sharp-angled domain wall becomes less sharp, occurring in the 80 to 108 C temperature range.

Hung, Ching-Cheh↗

Thermal conductance of augmented pressed metallic contacts at liquid helium temperatures

The thermal conductance of uncoated oxygen-free high conductivity (OFHC) copper, 6061-T6 aluminum, free-machining brass, and 304 stainless steel sample pairs which were augmented with a gold coated 6061-T6 aluminum washer inserted between the contact surfaces was measured over the temperature range of 1.6 to 6.0 K, with applied forces from 22 to 670 N. The contact surfaces of the sample pairs were prepared with a 0.8 micron lapped finish, while the finish of the aluminum washer was 0.2 micron lapped. The contribution to the overall thermal impedance by the bulk conductance of the aluminum washer was negligible. It was found that addition of the washer offered no significant conductance improvement over an uncoated single contact pair; any benefits from using the gold plated washer were counteracted by the addition of two more contact surfaces. Additionally, the thermal conductance of a 'combination' aluminum sample pair having one gold coated and one uncoated surface was measured and compared to the washer pair. The ratio of the conductance of the washer pair to half the conductance of the 'combination' pair was found to be constant and near unity over the temperature range of the data obtained, within experimental error.

Salerno, L. J.↗

Thermal conductance of two interface materials and their applications in space systems

Two polymeric materials, the Cho-Therm 1671 elastomer and the CV-2946 conductive RTV silicone, have been evaluated. Tests were conducted in vacuum and in air, for many clamping pressures, power densities, and as a function of time. Results obtained show that the CV-2946 thermal conductance after 24 hour in vacuum is 0.62 W/sq cm C(4W/sq in C) when clamped with an average pressure of about 350 psi. The maximum conductance of Cho-Therm 1671 is 4.3 W/sq in C at the clamping pressure about 200 psi. After 72 h in vacuum, the conductance reaches a steady 3.4 W/sq in C, independent of clamping pressure. It is concluded that the tightly bolted, torqued fixtures do not buckle or distort and provide an optimum thermal conductance. The fixtures simulating an actual spacecraft configuration suffered severe bowing and separating, which caused considerable degradation of conductance values.

Scialdone, J. J.↗

Simultaneous solution for core magnetic field and fluid flow beneath an electrically conducting mantle

The effects of laterally homogeneous mantle electrical conductivity were included in steady, frozen-flux core surface flow estimation along with refinements in method and weighting. The refined method allows simultaneous solution for both the initial radial geomagnetic field component at the core-mantle boundary (CMB) and the sub-adjacent fluid motion; it also features Gauss' method for solving the non-linear inverse problem associated with steady motional induction. The tradeoff between spatial complexity of the derived flows and misfit to the weighted Definitive Geomagnetic Reference Field models (DGRF's) is studied for various mantle conductivity profiles. For simple flow and a fixed initial geomagnetic condition, a fairly high deep-mantle conductivity performs better than either insulating or weakly conducting profiles; however, a thin, very high conductivity layer at the base of the mantle performs almost as well. Simultaneous solution for both initial geomagnetic field and flow reduces the misfit per degree of freedom even more than does changing the mantle conductivity profile. Moreover, when both core field and flow are estimated, the performance of the solutions and the derived flows become insensitive to the conductivity profile.

Voorhies, Coerte V.↗

Thermal conductivity of zirconia thermal barrier coatings

Thermal barrier coatings (TBC's) applied to the hot gas components of turbine engines lead to enhanced fuel efficiency and component reliability. Understanding the mechanisms which control the thermal transport behavior of the TBC's is of primary importance. Physical vapor description (PVD) and plasma spraying (PS) are the two most commonly used coating techniques. These techniques produce coatings with unique microstructures which control their performance and stability. The PS coatings were applied with either standard power or hollow sphere particles. The hollow sphere particles yielded a lower density and lower thermal conductivity coating. The thermal conductivity of both fully and partially stabilized zirconia, before and after thermal aging, will be compared. The thermal conductivity of the coatings permanently increase upon being exposed to high temperatures. These increases are attributed to microstructural changes within the coatings. Sintering of the as fabricated plasma sprayed lamellar structure is observed by scanning electron microscopy of coatings isothermally heat treated at temperatures greater than 1100 C. During this sintering process the planar porosity between lamella is converted to a series of small spherical pores. The change in pore morphology is the primary reason for the observed increase in thermal conductivity. This increase in thermal conductivity can be modeled using a relationship which depends on both the temperature and time of exposure. Although the PVD coatings are less susceptible to thermal aging effects, preliminary results suggest that they have a higher thermal conductivity than PS coatings, both before and after thermal aging. The increases in thermal conductivity due to thermal aging for partially stabilized plasma sprayed zirconia have been found to be less than for fully stabilized plasma sprayed zirconia coatings. The high temperature thermal diffusivity data indicates that if these coatings reach a temperature above 1100 C during operation, they will begin to lose their effectiveness as a thermal barrier.

Dinwiddie, R. B.↗

Simultaneous solution for core magnetic field and fluid flow beneath an electrically conducting mantle

The effects of laterally homogeneous mantle electrical conductivity have been included in steady, frozen-flux core surface flow estimation along with refinements in method and weighting. The refined method allows simultaneous solution for both the initial radial geomagnetic field component at the core-mantle boundary and the subadjacent fluid motion; it also features Gauss' method for solving the nonlinear inverse problem associated with steady motional induction. The trade-off between spatial complexity of the derived flows and misfit to the weighted Definitive Geomagnetic Reference Field models is studied for various mantle conductivity profiles. For simple flow and a fixed initial geomagnetic condition a fairly high deep-mantle conductivity performs better than either insulating or weakly conducting profiles; however, a thin, very high conductivity layer at the base of the mantle performs almost as well. Simultaneous solution for both initial geomagnetic field and fluid flow reduces the misfit per degree of freedom even more than does changing the mantle conductivity profile. Moreover, when both core field and flow are estimated, the performance of the solutions and the derived flows become insensitive to the conductivity profile.

Voorhies, Goerte V.↗

Thermal conductivity of zirconia thermal barrier coatings

Thermal barrier coatings (TBC's) applied to the hot gas components of turbine engines lead to enhanced fuel efficiency and component reliability. Understanding the mechanisms which control the thermal transport behavior of the TBC's is of primary importance. Physical vapor deposition (PVD) and plasma spraying (PS) are the two most commonly used coating techniques. These techniques produce coatings with unique microstructures which control their performance and stability. The PS coatings were applied with either standard powder or hollow sphere particles. The hollow sphere particles yielded a lower density and lower thermal conductivity coating. The thermal conductivity of both fully and partially stabilized zirconia, before and after thermal aging, will be compared. The thermal conductivity of the coatings permanently increases upon exposed to high temperatures. These increases are attributed to microstructural changes within the coatings. Sintering of the as-fabricated plasma sprayed lamellar structure is observed by scanning electron microscopy of coatings isothermally heat treated at temperatures greater than 1100 C. During this sintering process the planar porosity between lamella is converted to a series of small spherical pores. The change in pore morphology is the primary reason for the observed increase in thermal conductivity. This increase in thermal conductivity can be modeled using a relationship which depends on both the temperature and time of exposure. Although the PVD coatings are less susceptible to thermal aging effects, preliminary results suggest that they have a higher thermal conductivity than PS coatings, both before and after thermal aging. The increases in thermal conductivity due to thermal aging for partially stabilized plasma sprayed zirconia have been found to be less than for fully stabilized plasma sprayed zirconia coatings. The high temperature thermal diffusivity data indicate that if these coatings reach a temperature above 1100 C during operation, they will begin to lose their effectiveness as a thermal barrier.

Dinwiddie, R. B.↗

Computer Modeling of the Thermal Conductivity of Cometary Ice

The main objective of this research was to estimate the thermal conductivity of cometry ices from computer simulations of model amorphous ices. This was divided into four specific tasks: (1) Generating samples of amorphous water ices at different microporosities; (2) Comparing the resulting molecular structures of the ices with experimental results, for those densities where data was available; (3) Calculating the thermal conductivities of liquid water and bulk amorphous ices and comparing these results with experimentally determined thermal conductivities; and (4) Investigating how the thermal conductivity of amorphous ice depends upon the microscopic porosity of the samples. The thermal conductivity was found to be only weakly dependent on the microstructure of the amorphous ice. In general, the amorphous ices were found to have thermal conductivities of the same order of magnitude as liquid water. This is in contradiction to recent experimental estimates of the thermal conductivity of amorphous ice, and it is suggested that the extremely low value obtained experimentally is due to larger-scale defects in the ice, such as cracks, but it is not an intrinsic property of the bulk amorphous ice.

Bunch, Theodore E.↗