Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Commercialization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Endpoint Use Efficiency Comparison for AC and DC Power Distribution in Commercial Buildings

Advances in power electronics and their use in Miscellaneous Electric Loads (MELs) in buildings have resulted in increased interest in using low-voltage direct current (DC) power distribution as a replacement for the standard alternating current (AC) power distribution in buildings. Both systems require an endpoint converter to convert the distribution system voltage to the MELs voltage requirements. This study focused on the efficiency of these endpoint converters by testing pairs of AC/DC and DC/DC power converters powering the same load profile. In contrast to prior studies, which estimated losses based on data sheet efficiency and rated loads, in this study, we used part load data derived from real-world time-series load measurements of MELs and experimentally characterized efficiency curves for all converters. The measurements performed for this study showed no systematic efficiency advantage for commercially available DC/DC endpoint converters relative to comparable, commercially available AC/DC endpoint converters. For the eight appliances analyzed with the pair of converters tested, in 50%, the weighted energy efficiency of the DC/DC converter was higher, while, for the other 50%, the AC/DC converter was. Additionally, the measurements indicated that the common assumption of using either data sheet efficiency values or efficiency at full load may result in substantial mis-estimates of the system efficiency.

AC/DC converters↗

Commercial PV Inverter IEEE 1547.1 Ride-Through Assessments Using an Automated PHIL Test Platform

As more countries seek solutions to their de-carbonization targets using renewable energy (RE) technologies, interconnection standards and national grid codes for distributed energy resources (DER) are being updated to support higher penetrations of RE and improve grid stability. Common grid-code revisions mandate DER devices, such as solar inverters and energy storage systems, ride-through (RT) voltage and frequency disturbances. This is necessary because as the percentage of generation from DER increases, there is a greater risk power system faults will cause many or all DER to trip, triggering a substantial load-generation imbalance and possible cascading blackout. This paper demonstrates for the first time a methodology to verify commercial DER devices are compliant to new voltage, frequency, and rate of change of frequency (ROCOF) RT requirements established in IEEE Std. 1547-2018. The methodology incorporates a software automation tool, called the SunSpec System Validation Platform (SVP), in combination with a hardware-in-the-loop (HIL) system to execute the IEEE Std. 1547.1-2020 RT test protocols. In this paper, the approach is validated with two commercial photovoltaic inverters, the test results are analyzed for compliance, and improvements to the test procedure are suggested.

14 SOLAR ENERGY↗

Comparison of Eco-Friendly Ionic Liquids and Commercial Bio-Derived Lubricant Additives in Terms of Tribological Performance and Aquatic Toxicity

Approximately half of the lubricants sold globally find their way into the environment. The need for Environmentally Acceptable Lubricants (EALs) is gaining increased recognition. A lubricant is composed of a base oil and multiple functional additives. The literature has been focused on EAL base oils, with much less attention given to eco-friendly additives. This study presents the tribological performance and aquatic toxicity of four short-chain phosphonium-phosphate and ammonium-phosphate ionic liquids (ILs) as candidate anti-wear and friction-reducing additives for EALs. The results are benchmarked against those of four commercial bio-derived additives. The four ILs, at a mere 0.5 wt% concentration in a synthetic ester, demonstrated a 30–40% friction reduction and >99% wear reduction, superior to the commercial baselines. More impressively, all four ILs showed significantly lower toxicity than the bio-derived products. In an EPA-standard chronic aquatic toxicity test, the sensitive model organism, Ceriodaphnia dubia, had 90–100% survival when exposed to the ILs but 0% survival in exposure to the bio-derived products at the same concentration. This study offers scientific insights for the future development of eco-friendly ILs as lubricant additives.

36 MATERIALS SCIENCE↗

Repurposing Offshore Infrastructure for Clean Energy (ROICE) vs. Decommissioning – Commercial Considerations

Abstract The Repurposing Offshore Infrastructure for Clean Energy (ROICE) Program, a collaboration of the energy industry and University of Houston, proposes extending the life of up to 1,500 oil and gas platforms in the Outer Continental Shelf of the Gulf of Mexico, USA. Rather than decommissioning or converting them to underwater reefs at the end of their oil and gas production phase, the platforms could be transformed for 10–20+ years of renewable energy development, such as green hydrogen production or carbon dioxide injection and storage, resulting in significant economic, environmental, and social benefits. ROICE has already published papers on the technical and regulatory considerations for such repurposing projects. This paper focuses on the commercial considerations needed to ensure ROICE projects are economically viable and sustainable for all involved. There are potentially many entities that can come together to progress a repurposing project, including oil and gas asset owners, operators, investors, developers, contractors, manufacturers, and regulators. This paper looks at possible combinations of these entities in a ROICE project team and the various commercial agreements that will be needed to ensure a mutually successful outcome. The paper proposes adapting existing industry agreements and templates to suit, including asset transfer agreements (ATA), asset purchase agreements (APA) and joint purchasing agreements (JOA). An ATA or APA can be drafted to address the obligations and issues involved in the sale or transfer of an existing oil and gas facility to the developer, operator, non-operating interests, and financial investors in a ROICE project, while a JOA can be drafted to govern the rights, obligations, and financial requirements of the parties involved in the development and operation.

Legge, G. [Endeavor Management, USA]↗

Achieving Diesel Powertrain Ownership Parity in Battery Electric Heavy Duty Commercial Vehicles Using a Rapid Recurrent Recharging Architecture

Battery electric vehicles (BEV) in heavy duty (HD) commercial freight transport face challenging technoeconomic barriers to adoption. Specifically, beyond safety and compliance, fleet and operational logistics require both high up-time and parity with diesel system productivity/Total Cost of Ownership (TCO) to enable strong adoption of electrified powertrains. At present, relatively high energy storage prices coupled with the increased weight of BEV systems limit the practicality of HD commercial freight transport to shorter range applications, where smaller batteries will suffice for the mission energy requirements (single operational shift). This paper presents an approach to extend the feasibility of BEV HD trucking for a broad range of applications. The concept is based on the leveraging rapid and recurrent recharging of a BEV HD truck that may either already make frequent stops due to shipment drop-offs/reloading or be required to make frequent stops along with longer missions for recharging. While the challenges of the latter are well appreciated, the concept proposed explores making minimal impact to overall mission time by targeting high C-rate charging while optimizing the frequency (miles) through which these events must occur. The concept optimizes battery size and chemistry, such that the expected life (years and total energy throughput) is balanced with the depth of discharge between recharging events, thus making complete use of the energy available through the life of the battery system. The solution is constrained to minimize the impact on payload capacity. The paper analyzes critical levers in achieving diesel price parity (based on a simplified vehicle TCO), achieved through different purchase options (including lease versus buy) and operational models (half-life swap out). Finally, the paper identifies the application design domain where these solutions are viable with limited impact on fleet operations.

Sujan, Vivek↗

Development of a hardware-in-the-loop testbed for laboratory performance verification of flexible building equipment in typical commercial buildings

The goals of reducing energy costs, shifting electricity peaks, increasing the use of renewable energy, and enhancing the stability of the electric grid can be met in part by fully exploiting the energy flexibility potential of buildings and building equipment. The development of strategies that exploit these flexibilities could be facilitated by publicly available high-resolution datasets illustrating how control of HVAC systems in commercial buildings can be used in different climate zones to shape the energy use profile of a building for grid needs. This article presents the development and integration of a Hardware-In-the-Loop Flexible load Testbed (HILFT) that integrates physical HVAC systems with a simulated building model and simulated occupants with the goal of generating datasets to verify load flexibility of typical commercial buildings. Compared to simulation-only experiments, the hardware-in-the-loop approach captures the dynamics of the physical systems while also allowing efficient testing of various boundary conditions. The HILFT integration in this article is achieved through the co-simulation among various software environments including LabVIEW, MATLAB, and EnergyPlus. Although theoretically viable, such integration has encountered many real-world challenges, such as: 1) how to design the overall data infrastructure to ensure effective, robust, and efficient integration; 2) how to avoid closed-loop hunting between simulated and emulated variables; 3) how to quantify system response times and minimize system delays; and 4) how to assess the overall integration quality. Lessons-learned using the examples of an AHU-VAV system, an air-source heat pump system, and a water-source heat pump system are presented.

Chen, zhelun↗

Modeling commercial-scale CO 2 storage in the gas hydrate stability zone with PFLOTRAN v6.0

Abstract. Safe and secure carbon dioxide (CO2) storage is likely to be critical for mitigating some of the most dangerous effects of climate change. In the last decade, there has been a significant increase in activity associated with reservoir characterization and site selection for large-scale CO2 storage projects across the globe. These prospective storage sites tend to be selected for their optimal structural, petrophysical, and geochemical trapping potential. However, it has also been suggested that storing CO2 in reservoirs within the CO2 hydrate stability zone (GHSZ), characterized by high pressures and low temperatures (e.g., Arctic or marine environments), could provide a natural thermodynamic barrier to gas leakage. Evaluating the prospect of commercial-scale, long-term storage of CO2 in the GHSZ requires reservoir-scale modeling capabilities designed to account for the unique physics and thermodynamics associated with these systems. We have developed the HYDRATE flow mode and the accompanying fully implicit parallel well model in the massively parallel subsurface flow and reactive transport simulator PFLOTRAN to model CO2 injection into the marine GHSZ. We have applied these capabilities to a set of CO2 injection scenarios designed to reveal the challenges and opportunities for commercial-scale CO2 storage in the GHSZ.

carbon storage↗

A Preliminary Investigation on the Cost Reduction Potential of Optimizing Bore Fields for Commercial Ground Source Heat Pump Systems

The high initial cost of ground heat exchangers (GHE) is a primary hurdle preventing wider adoption of ground source heat pump (GSHP) systems. GHEs used for commercial GSHP systems commonly consist of vertical boreholes installed on a grid with equal spacing between boreholes. Significant thermal loads require a large number of boreholes to be present in the field. However, due to thermal interactions among boreholes, the ground formation in the center of a bore field can, over time, become thermally saturated when the thermal load is not balanced on an annual basis. The loss of effectiveness due to thermal saturation at the center boreholes in regularly spaced borehole fields suggests that larger spacing near the center of the bore field could be more optimal, and in return reduce initial costs. Through computer simulations using the latest development of a GHE modeling tool, this study evaluates the impacts of various unconventional designs of the borehole field on the performance and cost of the GHEs of a typical commercial GSHP system. The unconventional designs include irregular spacing among boreholes with decreased spacing around the perimeter and increased spacing in the interior of the field. The unconventional bore field design shortens the total drilling length by up to 42% while giving better heat transfer performance than a conventional bore field design. The significant total bore length reduction is due to improved heat transfer effectiveness of each borehole in the unconventional bore field.

Spitler, Jeffery↗

Peak Power Reduction for HVAC Operations in Multi-unit Commercial Buildings

The load profiles of most commercial consumers are characterized by brief periods of very high power consumption followed by intervals of relatively lower demand. In order to flatten commercial load profiles, several power utilities in addition to billing energy consumption, levy a demand charge (DC) on the monthly peak demand. In this work, we consider the problem of joint optimization of energy costs (EC) and DC incurred by a multi-unit building which follows a demand response (DR) program. Despite the non-linear structure of the problem, we show how the optimal solutions can be obtained efficiently using linear programming. We evaluate the performance of the proposed power control scheme for various climate zones in the US. We show that depending on the ambient conditions and the prescribed tariff structure, our strategy can result in savings of up to nearly 19% compared to the baseline.

Raza Naqvi, Syed A.↗

Predicting and Managing Risk to Bats at Commercial Wind Farms using Acoustics

Bat populations in North America face novel threats from white-nose syndrome and widespread turbine-related mortality related to the rapidly expanding wind power industry in addition to long-standing pressures from habitat loss and degradation. Bats, unlike most small mammals, are long-lived and slow to reproduce, highlighting the importance of understanding and managing anthropogenic sources of mortality. My dissertation research used acoustic bat detectors to measure bat activity at commercial wind projects, predict patterns in risk, and design strategic measures to reduce fatality rates by curtailing turbine operation during periods when bats are most active. Bats collide with wind turbines only when their rotors are spinning, and risk of turbine-related fatality is therefore a dynamic factor that can be manipulated by curtailing turbine operation when bats are active. We first measured inter-detector variation in metrics of acoustic bat activity to understand how the acoustic detection process may affect inferences related to spatial and temporal variation in bat activity. Using acoustic detectors mounted on top of wind turbines at two commercial wind farms in West Virginia, we then demonstrated that the amount of bat activity recorded when turbines were operating aligned closely with bat fatality rates on multiple scales. Accordingly, the metric of bat activity exposed to turbine operation provides a meaningful, quantitative indicator of turbine-related bat fatality risk. Further, bats responded consistently to changing wind speed and temperature at turbines in both wind farms across multiple years, enabling exposed bat activity to be predicted accurately among turbines and years. Building on these results, we simulated exposure of bats to turbine operation and energy loss for curtailment strategies recommended by state and federal agencies in the United States and Canada. By adjusting parameters such as cut-in wind speeds and temperature thresholds, we demonstrated the ability to design strategic curtailment programs that achieve equivalent or greater predicted reductions in bat activity exposure for substantially less energy-production loss. Characterizing fatality risk on a finer scale using acoustics will help regulatory agencies and the wind industry alike reduce risks of population-level impacts to vulnerable bat species while continuing to expand large-scale renewable energy generation.

17 WIND ENERGY↗

Using Wi-Fi Location-Based Services (LBS) for Commercial Building Occupancy Sensing

From May 2019 through October 2022, this DOE-funded project investigated and demonstrated the use of Wi-Fi Location-Based Services (LBS) to perform occupancy sensing in commercial buildings. Wi-Fi LBS can be used to detect the presence of Wi-Fi enabled mobile devices and laptops that accompany occupants as they move through the building. These signals can be used to determine occupant presence, head count, and location. When integrated with the building automation system, this emerging technology approach can be used to manage other connected systems such as lighting and HVAC to reduce energy usage in the building and improve occupant comfort. An open source location detection algorithm was developed, which uses data collected from three or more Wi-Fi access points to determine the presence and estimate the location of mobile devices and laptops. Access points can detect Wi-Fi enabled devices even if they are not connected to the existing Wi-Fi network. Building occupancy is determined based on the presence, location, and movement of these devices through the space. From lab and small-scale in-situ testing, the Location Detection Algorithm (LDA) was found to be accurate to within 10 feet and could be further refined by tuning the algorithm for the specific space characteristics such as layout and obstructions (walls, furniture, etc.). An open source method to integrate the occupancy data with existing building automations systems was investigated. The Wi-Fi occupancy sensing approach was then demonstrated and validated at two commercial buildings located in Minnesota and Wisconsin.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Demonstration of Power over Ethernet (PoE) Technologies in Commercial and Institutional Buildings

PoE technologies are currently ubiquitous in offices in the form of phones, access points, and IP security cameras and managed by on-site IT staff. As low voltage DC-power capabilities have increased with network switches, PoE devices are now being integrated across additional building systems, including lighting, computers, and HVAC controls. Since PoE devices are connected to network switches, energy monitoring and management can be performed through the IT network management software. Data and results from technology validations are still very limited for PoE equipment. This lack of information hinders higher adoption as its benefits and challenges have been insufficiently quantified in real-world scenarios. The use of IT network switches to power and control lighting, plug loads, and HVAC were demonstrated at a variety of sites including offices, schools, and a hotel. This paper presents the findings of a three-year DOE-/State of Minnesota-funded project that demonstrated and assessed the energy and non-energy benefits of Power over Ethernet (PoE) technologies at four commercial/institutional sites. The goals of the demonstrations were to: (1) assess the receptiveness of commercial and institutional markets to these new technologies, (2) demonstrate the feasibility of PoE technologies within standard design/construction practices and commercial codes, (3) assess the energy and cost savings opportunities of these technologies, (4) provide energy management opportunities where they typically are not available, and (5) formulate approaches to spur adoption of these technologies in the marketplace.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ComStock: Commercial Building Stock Energy Consumption Dataset

The commercial building sector stock model, or ComStock, is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States.

building↗

Panel Session 99: Commercial LLW Management: Global Perspective

This panel focused on opportunities and challenges in providing commercial nuclear waste management services in a global context. The panelists commented on their approach to establishing new businesses, overcoming communication barriers acquiring / maintaining skills and capabilities and delivering commercial nuclear waste management projects in a range of regulatory and socio-economic environments. The panel discussion was followed by a Q and A session with audience participation. Panelist with presentations: BGE Technology (Thilo von Berlepsch)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Utilizing Commercial Submersible Mixer Pumps for Sludge Removal in Savannah River Site's Tank 26 - 20289

The Savannah River Site (SRS) Liquid Waste System (LWS) safely manages, stores, treats, and dispositions liquid radioactive waste. The LWS consists of 51 underground waste storage tanks (eight of which are operationally closed and filled with grout), waste evaporators, treatment facilities, and solidification facilities, known as the Defense Waste Processing Facility (DWPF) and Saltstone Production Facility (SPF). One of the waste storage tanks, Tank 26, was placed into service in 1980 as an F Tank Farm (FTF) Evaporator Feed Tank. From 1980 to 2013, Tank 26 received F Canyon receipts and dilute supernate that was then transferred to the 242-16F FTF Evaporator for volume reduction. In 2013, the steam tube bundle failed in the FTF Evaporator, and the decision was made not to repair/resume evaporator operation. During operation of Tank 26, solids built up to a level of 2.03 m in the tank with a volume of 1062.9 kL. Due to the evaporator failure and subsequent shutdown, the solids in Tank 26 were selected to feed Sludge Batch 10, which is collected and prepped prior to being sent to DWPF for final disposition. To accomplish solids removal, Commercial Submersible Mixer Pumps (CSMPs) were selected to slurry the solids in preparation to be sent to Tank 51. Four CSMPs were installed in Tank 26 with each one installed in a separate quadrant of Tank 26. This work would mark the first deployment of CSMPs in an SRS waste tank. The CSMPs were developed in response to operational issues from previous mixing pumps and budgetary constraints. The CSMPs use the concept of modifying commercially available equipment for nuclear waste applications. The CSMPs consist of a 230-horsepower submersible mixing pump (manufactured by GPM, Inc.) joined to a mast fabricated at SRS. For this application, Savannah River Remediation (SRR) design services was challenged to provide a mast design that required no steel superstructure support system on top of Tank 26. Also, SRR design services provided a simplified Tank 26 riser interface that did not require extensive machine parts to adjust height of the suction screen of the CSMP within the tank. Other design improvements include no requirements for tank top radiation monitors and no requirements for flushing of the CSMPs during startup/shutdown operations. The CSMPs were operated at an initial height of 2.29 m above the Tank 26 bottom for 10 days. After sludge sounding, the CSMPs were lowered to a height of 1.52 m with no issues due to proper work planning and the simplified riser interface. With the CSMPs lowered to a level of 1.52 meters above the tank bottom, the CSMPs were operated for 12 days and another sounding was performed. The sounding level came back matching the disturbance depth results of the first pump run. Chemistry samples were analyzed while the tank was left to settle. The analysis revealed enough weight percent solids to provide good feed to Sludge Batch 10. Also, the results revealed the supernate within the mixture would provide good salt solution feed to Salt Waste Processing Facility (SWPF) Salt Batch 3. So, the plan was modified to let the disturbed solids settle and decant the salt solution for addition to SWPF Salt Batch 3. Then water will be added back to Tank 26, and the CSMPs run in order to wash the solids to decrease settling time prior to being sent to Tank 51 for Sludge Batch 10. Utilizing CSMPs for waste removal in an SRS Tank has provided a cost-effective means for further waste removal efforts. In addition, the CSMPs are easier to operate by utilizing a robust and simplified design. The CSMPs performed quite well with no process shutdown or delays during operation. As a result, CSMPs are integral to the future of removing radioactive waste from storage tanks at SRS. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Decarbonizing the Building Sector: A Human-Centered Study Focused on Small/Light Commercial Building Energy Equity

Decarbonization of the building sector is no small feat; buildings account for 40% of primary energy consumption, and fossil-fuel combustion in buildings leads to roughly 30% of total greenhouse gas emissions. Energy efficiency, electrification and smart technologies are fundamental strategies to reduce consumption and shift away from fossil-fuel use in buildings. This energy transition carries significant societal risks unless the shift is carried out with equity and justice as a top priority. Low-income, vulnerable and communities of color have higher energy burdens compared to affluent populations. Furthermore, systemic racism and historic exclusionary policies have resulted in increased risks (environmental, climatic, economic, and social) to low-income and communities of color, and underserved communities often do not have financial resources for, or access to, advanced building technologies. The U.S. Department of Energy is funding research to characterize and develop solutions to the challenges of equity and justice that complicate the ability of communities to contribute to goals for decarbonization. Our project has a specific focus on small commercial buildings and the businesses that occupy them. Significantly less is known about the burdens and risks these businesses experience or the challenges they face in pursuing decarbonization, or how those are affected by income and race, in comparison to research on energy equity and justice for diverse households. The project team includes the Pacific Northwest National Laboratory, Arizona State University and Clark Atlanta University. Researchers are conducting semi-structured interviews with small business owners in underserved communities in Phoenix and Atlanta, followed by a survey distributed to the larger community to learn more about the equity and justice issues that communities with different racial, economic, and cultural backgrounds face. Results will help inform an actionable and replicable framework for engaging small commercial building owners/operators to catalyze the reduction of energy burdens and increase equity.

Antonopoulos, Chrissi A.↗

A Simulation Framework for Analyzing the Impact of Stochastic Occupant Behaviors on Demand Flexibility in Typical Commercial Buildings

As one of the primary users of the electric grid, buildings and building equipment, including heating, ventilation, and air conditioning (HVAC) systems, can be leveraged to provide the flexible demand needed to balance the grid. Typical strategies to achieve demand flexibility are to reduce electricity use during peak or critical periods by shutting down equipment or relaxing system setpoints, which will inevitably impact the occupants’ comfort. When occupants feel uncomfortable, they may take actions to regain their comfort, and some of those actions (such as turning on a personal fan) may have a negative impact on meeting the demand response goal. Therefore, it is important to incorporate occupant behaviors into the assessment ofthe building demand flexibility potential. In this study, a simulation framework that includes simulation of zone thermal loads, an HVAC system, and occupant behaviors, was developed to investigate the impact of occupant behaviors on demand flexibility. A case study was conducted using a small office model from the U.S. Department of Energy (DOE) Commercial Prototype Building Models to simulate the building envelope and zone loads. An agent-based occupant thermal behavior model was adapted to forecast occupants’ thermal comfort and their resulting thermal behaviors. An artificial neural network (ANN) based airflow model trained from a computational fluid dynamics (CFD) model of the zone was adopted to better predict the ambient environment of each occupant. An air-source heat pump simulation model that was calibrated from a real two-stage air-source heat pump system was used as the HVAC system. A typical load shedding event during peak hours was studied. Repeated simulations were conducted to capture the stochastic effects of occupant behaviors. The interplay between the demand flexibility, occupant comfort and behavior were analyzed by evaluating key performance indicators, including the energy use, occupant discomfort duration, and occupant behavior duration during the peak period. The results suggest that this framework can be used to analyze typical commercial buildings and their HVAC systems in terms ofdemand flexibility potential under the impact of occupant behaviors.

Chen, Zhelun↗

Commercialization of High-Density High Assay Low Enriched Uranium Fuel Systems

The Office of Reactor Conversion and Uranium Supply (NA 231) at the National Nuclear Security Administration leads the conversion effort for the United States High Performance Research Reactors (USHPRR). These reactors are the final civilian reactors in the US to transition from High Enriched Uranium (HEU) to high assay low enriched uranium (HALEU). Each of these reactors represents unique capabilities and no currently available fuel system meets their needs for conversion. The Fuel Fabrication (FF) Pillar of the USHPRR project is responsible for the fabrication of experimental elements, conversion elements, and establishing a commercial economical production capability. FF is also responsible to share with the domestic and international community the theoretical knowledge gained. Other pillars within the USHPRR project provide the experimental and conversion fuel designs, assist the reactors with licensing activities, and ensure the entire fuel cycle is evaluated. Over the last decade, FF has worked with the production partners at Y-12 National Security Complex (Y-12) and BWXT Nuclear Operations Group, Research and Test Reactors (BWXT). Y-12 has begun processing the alloy feedstock for the conversion elements with a qualified process. BWXT has started the final fabrication of the experimental elements. Once the experimental elements are complete, BWXT will begin conversion element fabrication. The FF Pillar resides at Pacific Northwest National Laboratory (PNNL) and uses PNNL, universities, commercial vendors, and the DOE national laboratory system to evaluate process development activities to improve the process steps. FF supports the fabrication of two high density fuel systems, monolithic U-10Mo (Figure 1) and Uranium Silicide (Figure 2). The U-10Mo fuel system is further along the development process. FF assists in long term planning with the production partners. This includes ramping production of the elements from experimental quantities to annual steady state needs. As part of the ramp up, opportunities to improve yield and product quality are identified to ensure the fuel systems are cost effective.

Catalan, Michael A. [BATTELLE (PACIFIC NW LAB)]↗