Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Commercialization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Thermo-economic analysis of a solid oxide fuel cell-gas turbine hybrid with commercial off-the-shelf gas turbine

The thermodynamic and economic performance of a natural gas-fueled solid oxide fuel cell (SOFC)-gas turbine (GT) hybrid system with a commercial off-the-shelf GT is investigated. Until today, commercial GTs are primarily engineered for the direct use of energy dense fuels, such as natural gas, and the integration of commercial GTs into a SOFC-GT hybrid remains challenging. In this work technically feasible and economically viable GT operating modes are identified to gauge the technology’s competitiveness on the free market. Steady state, full load operating conditions were established for various GT operating modes: I) constant spool speed operation, II) variable spool speed operation and III) partially closed compressor inlet guide vanes. For each GT operating mode, the performance was investigated over a range of SOFC fuel utilization factors, while considering physical constraints inside the SOFC, such as local temperature gradients in flow direction as well as overall cell temperature differences. The results of the thermodynamic evaluation served as inputs for the economic analysis of the SOFC-GT hybrid power plant. The results show that the integration of an off-the-shelf GT not only results in a significant derating of the GT, but also substantially impacts the SOFC operation, the main power producer in this SOFC-GT hybrid. To maximize the SOFC power output it is desirable operate the GT in a region of high air mass flow rates and low pressure ratios, which increases the number of stacks that can be accommodated and reduces the SOFC cooling requirement. The lowest costs of electricity are obtained at constant spool speed operation, while the highest efficiencies are reached at variable spool speed operation. Critical for the integration of off-the-shelf GTs, which historically have been designed for natural gas, is the surge margin. The largest surge margins are obtained by closing the compressor inlet guide vanes. Furthermore, higher SOFC fuel utilization factors are shown to increase the surge margin as the turbine firing temperature is decreased.

25 ENERGY STORAGE↗

Characterization of the indoor far-field aerosol transmission in a model commercial office building

As businesses gradually reopen and employees return to work, the potential spread of SARS-CoV-2 and its variants through airborne transmission via the heating, ventilation, and air-conditioning (HVAC) systems of commercial building raises concerns. Since the general practice in commercial buildings is to use low-efficiency air filters and given that indoor air is generally recycled, the degree to which cross-zone aerosol transmission occurs is of interest. To quantify the cross-zone aerosol transmission, experiments were conducted using a synthetic test aerosol in the five zones on the first floor of a model commercial office building at the Oak Ridge National Laboratory. Because the synthetic aerosol was tagged with fluorescent salt, the aerosol generated from the source zone can be distinguished from the background aerosols due to its unique fluorescent signal. Data from cross-zone campaigns showed that submicron-aerosol transmission was higher than the micron aerosols. In campaigns with doors closed, the submicron aerosol transmission was less than 16% and less than 11% for micron aerosol transmission. Finally, opening the interior doors that connecting different zones can significantly enhance the aerosol transmission for zones at the close proximity to the source, but has less impact on those farther away.

60 APPLIED LIFE SCIENCES↗

Performance investigation of alkaline direct methanol fuel cell with commercial PGM-free cathodic materials

Because little progress has been made in investigating the performance of alkaline direct methanol fuel cells (ADMFCs) with commercial materials (including platinum group metal (PGM)-free catalysts, anion exchange ionomers (AEIs), and anion exchange membranes (AEMs)), the objective of this work is to evaluate the performance of ADMFCs with all commercial materials, in order to establish a reference against which the performance of newly developed materials can be compared. Fe-N-C catalysts, Fumasep (FAA-3-50) based AEMs, and FAA3 based AEIs are here employed, and the parameters such as of operating temperature and methanol concentration are investigated and optimized. Electrochemical measurements show a performance increase with the temperature from 40 to 60 °C, and with the methanol concentration (from 1 to 5 M); followed by insignificant decrease with the further increase to 10 M. The best performance is achieved with 5 M methanol at 60 °C, and the remarkable powder density of 48.2 mW cm -2 was demonstrated under these conditions. This work provides insight into the large-scale application of ADMFC with commercial PGM-free materials.

25 ENERGY STORAGE↗

Translating a Material Discovery into a Commercial Product in the Modern Lithium-ion Battery Market

Lithium-ion batteries are essential for portable technology and are now poised to disrupt a century of combustion-based transportation. The electrification revolution could eliminate our reliance on fossil fuels and enable a clean energy future; advanced batteries would facilitate this transition. However, owing to the demanding performance, cost, and safety requirements, it is challenging to translate new materials from laboratory prototypes to commercial products. This Perspective describes that journey toward commercialization for a new lithium-ion battery anode material, TiNb2O7 (TNO). TNO is intended as an alternative to graphite or Li4Ti5O12 with better rate and safety characteristics than the former, and higher energy density than the latter. The high capacity of TNO stems from multielectron redox of Nb5+ to Nb3+, its operating voltage window well above Li+/Li reduction potential prevents lithium dendrite formation, and its open crystal structure leads to high-power performance. Nevertheless, the creation of a practical TNO anode was non-linear and non-trivial. Its history is built on 30 years on fundamental science that preceded its application as a battery, and its battery development included a nearly 30-year gap. The insights and lessons 2 contained in this Perspective, many of them acquired firsthand, serve two purposes: (i) to unite the disparate studies of TiNb2O7 into a coherent modern understanding relevant to its application as a battery material and (ii) to highlight some of the considerations of commercializing a new material that affect TiNb2O7 as well as new electrode candidates more generally.

Griffith, Kent J.↗

Nondestructive Analysis of Commercial Batteries

Electrochemical batteries play a crucial role for powering portable electronics, electric vehicles, large-scale electric grids, and future electric aircraft. However, key performance metrics such as energy density, charging speed, lifespan, and safety raise significant consumer concerns. Enhancing battery performance hinges on a deep understanding of their operational and degradation mechanisms, from material composition and electrode structure to large-scale pack integration, necessitating advanced characterization methods. These methods not only enable improved battery performance but also facilitate early detection of substandard or potentially hazardous batteries before they cause serious incidents. Here, this review comprehensively examines the operational principles, applications, challenges, and prospects of cutting-edge characterization techniques for commercial batteries, with a specific focus on in situ and operando methodologies. Furthermore, it explores how these powerful tools have elucidated the operational and degradation mechanisms of commercial batteries. By bridging the gap between advanced characterization techniques and commercial battery technologies, this review aims to guide the design of more sophisticated experiments and models for studying battery degradation and enhancement.

36 MATERIALS SCIENCE↗

Electrochemical CO 2 Conversion Commercialization Pathways: A Concise Review on Experimental Frontiers and Technoeconomic Analysis

Technoeconomic analysis (TEA) studies are vital for formulating guidelines that drive the commercialization of electrochemical CO 2 reduction (eCO 2 R) technologies. In this review, we first discuss the progress in the field of eCO 2 R processes by providing current state-of-the-art metrices (e.g., faradic efficiency, current density) based on the recent heterogeneous catalysts’ discovery, electrolytes, electrolyzers configuration, and electrolysis process designs. Next, we assessed the TEA studies for a wide range of eCO 2 R final products, different modes of eCO 2 R systems/processes, and discussed their relative competitiveness with relevant commercial products. Finally, we discuss challenges and future directions essential for eCO 2 R commercialization by linking suggestions from TEA studies. We believe that this review will catalyze innovation in formulating advanced eCO 2 R strategies to meet the TEA benchmarks for the conversion of CO 2 into valuable chemicals at the industrial scale.

54 ENVIRONMENTAL SCIENCES↗

Assessment of Plant and Microalgal Oil-Derived Nonisocyanate Polyurethane Products for Potential Commercialization

Green pathways for nonisocyanate polyurethane (NIPU) production have attracted increasing levels of interest. The reaction between 5-membered cyclic carbonate and polyamines is one of the most promising pathways to produce NIPU polymers. Though promising, major technical hurdles such as slow polymerization rate and poor performance hinder the commercialization of NIPU. In this paper, we screened several commercially available triglyceride oil feedstocks for NIPU products, focusing on polymerization kinetics and product performance for industrial application. The impact of carbonated group density on polymerization rate and mechanical strength was determined. We have demonstrated a remarkably higher reactivity of carbonated oil derived from feedstocks with polyunsaturated fatty acid (PUFA). The NIPU derived from such feedstocks also showed improved performance for industrial application. Unlike traditional polyurethane foam production that uses isocyanate and water to generate CO2 as a blowing reagent, there is no gas formation in NIPU polymerization. We have demonstrated a practical and cost-effective approach to produce NIPU foam material using bicarbonate as a blowing reagent. Furthermore, we conducted the first-ever technoeconomic analysis (TEA), revealing that profitable commercial NIPU production can be achieved when operating at sufficient production capacities.

09 BIOMASS FUELS↗

Extreme fast charging of commercial Li-ion batteries via combined thermal switching and self-heating approaches

Abstract The mass adoption of electric vehicles is hindered by the inadequate extreme fast charging (XFC) performance (i.e., less than 15 min charging time to reach 80% state of charge) of commercial high-specific-energy (i.e., >200 Wh/kg) lithium-ion batteries (LIBs). Here, to enable the XFC of commercial LIBs, we propose the regulation of the battery’s self-generated heat via active thermal switching. We demonstrate that retaining the heat during XFC with the switch OFF boosts the cell’s kinetics while dissipating the heat after XFC with the switch ON reduces detrimental reactions in the battery. Without modifying cell materials or structures, the proposed XFC approach enables reliable battery operation by applying <15 min of charge and 1 h of discharge. These results are almost identical regarding operativity for the same battery type tested applying a 1 h of charge and 1 h of discharge, thus, meeting the XFC targets set by the United States Department of Energy. Finally, we also demonstrate the feasibility of integrating the XFC approach in a commercial battery thermal management system.

25 ENERGY STORAGE↗

Development of new baseline models for U.S. medium office buildings based on commercial buildings energy consumption survey data

Building energy estimation for the building sector under various scenarios are needed for building energy regulation and policy making. This often starts with representative baselines (either empirical baseline or modeled baseline). Commercial Buildings Energy Consumption Survey (CBECS) data is a widely used empirical baseline for U.S. commercial buildings, but none of the existing baseline model are developed to represent the CBECS data. This paper aims to develop new baseline models for the U.S. medium office buildings, which can produce modeled baselines consistent with the CBECS data. Here, we introduced the methodology to create baseline models and the criteria to evaluate the performance of baseline models. The methodology consists of three phases: (1) identification of model inputs, (2) model calibration, and (3) model validation with uncertainty analysis. The evaluation index is the coefficient of variation of the root-mean-square deviation (CV(RMSD)) of site energy use intensities (EUIs) between the modeled baseline and empirical baseline. Then 30 new baseline models for two vintages (pre- and post-1980) and 15 climate zones were created. The evaluation shows that the CV(RMSD) is lower than 0.05 for the modeled baselines produced by the new baseline models. As a comparison, the CV(RMSD) is higher than 0.1 for the existing modeled baselines generated by DOE Commercial Reference Building Models. Further analysis shows that the new baseline models are able to capture the uncertainties of the representative features of existing buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Application of Site Controllers for Electrification of Commercial Fleet Vehicles

Electrification of transportation fleets presents a significant challenge for commercial customers. These challenges can be specific to region, weather, operating schedule, charging infrastructure, and other factors. This paper presents the value of integrating a site controller to monitor the health of assets and co-optimize the operation of commercial sites with multiple distributed energy resource technologies and electric vehicle fleets. The tests demonstrate smart-charging and vehicle-to-building uses compared to business-as-usual cases. The secondary objectives of power management for the customer vehicle are optimized by a planning tool (REopt) and integrated using the site controller. Any deviations from the planned dispatch are addressed by the real-time controllers offering tertiary controls, such as energy management, and limiting the reverse power flow (back into the grid). The results indicate that site controllers offer an efficient solution to manage the health of the connected assets and a scalable means to optimize the operations of a commercial customer with electrified transportation fleets.

ADVANCED PROPULSION SYSTEMS,POWER TRANSMISSION AND↗

Air Handling Unit Shutdowns During Scheduled Unoccupied Hours: US Commercial Building Stock Prevalence and Energy Impact

Commercial buildings account for 18% of U.S. energy consumption, with 44% used for heating, ventilation, and air conditioning (HVAC). American Society of Heating, Refrigerating and Air Conditioning Engineers (ASHRAE) 90.1 requires HVAC systems to shutdown fans and outdoor air ventilation during unoccupied times, only allowing fans to cycle on, without outdoor air, to maintain thermostat setpoints. However, it is minimally understood how often existing building operations align with energy code requirements and the energy implications of not doing so. This study used building automation system data from 843 buildings containing 5706 air handling units (AHUs) to determine three unoccupied AHU shutdown control schemes ranging in efficiency and then estimated their prevalence in the U.S. commercial building stock, segmented by building type. ComStock was then used to analyze the energy savings potential of implementing the most energy efficient unoccupied shutdown control scheme in non-participating buildings across the U.S commercial building stock. Results show that only 23% of AHUs align completely with the ASHRAE 90.1 requirement. ComStock modeling results show 4% annual stock energy savings by switching all non-participating buildings to the most efficient scheme, with 19% annual energy savings demonstrated for the median building switching from the least efficient scheme to the most efficient. Findings also show 114.5 TBtu electricity and 75.8 TBtu natural gas fuel savings when converting to the most efficient scheme. Furthermore, these findings help stakeholders understand the high prevalence of buildings not aligning with the ASHRAE-90.1 requirements for unoccupied AHU shutdowns and the energy savings potential of utilizing the most efficient unoccupied AHU shutdown scheme.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Commercial Fleet Level Emissions and Energy Tracker (COFLEET) v1.0

This tool generates the latest US commercial vehicle fleet composition and operational characteristics using 2021 US VIUS data and assess the fleetwide energy and emission outcomes. The emission rates for commercial trucks and default fleet composition are collected from the U.S. EPA's MOtor Vehicle Emission Simulator (MOVES4). The 2021 US VIUS data is applied to generate fleet characteristics such as the long-haul fraction and the vehicle mileage accumulation rate. The tool also provides fleet turnover and emission forecasts under various forecasted fleet electrification scenarios. This tool helps policymakers and practitioners advance the commercial fleet generation for emission models. This study also provides some sample datasets for state and local transportation/air quality agencies to test, which can reduce the estimation bias associated with using MOVES default fleets.

Xu, Xiaodan [Lawrence Berkeley National Laboratory↗

CIECAT (Cyber-Informed Engineering Commercial Buildings Analysis Tool) [SWR-25-172]

The Cyber-Informed Engineering Commercial Buildings Analysis Tool (CIECAT) was developed in collaboration with the U.S. Department of Energy’s Office of Cybersecurity, Energy Security, and Emergency Response (CESER). This tool is a energy source subcomponent integrated into the CIEMAT ecosystem and is developed to enhance the security and resilience of Commercial Buildings by incorporating Cyber-Informed Engineering (CIE) principles into the Commercial Buildings.

Etigowni, Sriharsha [National Laboratory of the Ro↗

Efficacy of commercial recombinant HVT vaccines against a North American clade 2.3.4.4b H5N1 highly pathogenic avian influenza virus in chickens

The outbreak of clade 2.3.4.4b H5 highly pathogenic avian influenza (HPAI) in North America that started in 2021 has increased interest in applying vaccination as a strategy to help control and prevent the disease in poultry. Two commercially available vaccines based on the recombinant herpes virus of turkeys (rHVT) vector were tested against a recent North American clade 2.3.4.4b H5 HPAI virus isolate: A/turkey/Indiana/22-003707-003/2022 H5N1 in specific pathogen free white leghorn (WL) chickens and commercial broiler chickens. One rHVT-H5 vaccine encodes a hemagglutinin (HA) gene designed by the computationally optimized broadly reactive antigen method (COBRA-HVT vaccine). The other encodes an HA gene of a clade 2.2 virus (2.2-HVT vaccine). There was 100% survival of both chicken types COBRA-HVT vaccinated groups and in the 2.2-HVT vaccinated groups there was 94.8% and 90% survival of the WL and broilers respectively. Compared to the 2.2-HVT vaccinated groups, WL in the COBRA-HVT vaccinated group shed significantly lower mean viral titers by the cloacal route and broilers shed significantly lower titers by the oropharyngeal route than broilers. Virus titers detected in oral and cloacal swabs were otherwise similar among both vaccine groups and chicken types. To assess antibody-based tests to identify birds that have been infected after vaccination (DIVA-VI), sera collected after the challenge were tested with enzyme-linked lectin assay-neuraminidase inhibition (ELLA-NI) for N1 neuraminidase antibody detection and by commercial ELISA for detection of antibodies to the NP protein. As early as 7 days post challenge (DPC) 100% of the chickens were positive by ELLA-NI. ELISA was less sensitive with a maximum of 75% positive at 10DPC in broilers vaccinated with 2.2-HVT. Both vaccines provided protection from challenge to both types of chickens and ELLA-NI was sensitive at identifying antibodies to the challenge virus therefore should be evaluated further for DIVA-VI.

60 APPLIED LIFE SCIENCES↗

Field Performance of Commercial Building Load Flexibility Using Model Predictive Control

Model Predictive Control (MPC) applied to buildings is starting to see some commercial adoption by companies. However, it is hard to estimate if relative energy cost savings are enough to justify the cost of MPC implementation with few reported demonstrations. In small commercial and residential buildings, a one size-fits-all solution can help reduce implementation costs, while in very large buildings or districts the potential energy cost savings magnitude can cover more tailored solutions. This estimation becomes harder for medium to large commercial buildings, where a one-size-fits-all solution cannot be adopted and potential energy cost savings might not be sufficient to cover a tailored solution. Therefore, value propositions in addition to energy efficiency alone can make MPC technology more attractive through additional energy cost savings. One such value proposition is load shifting in response to dynamic electricity prices. On this aspect, MPC is a key technology to unlock building thermal mass for energy flexibility in response to electric grid conditions. This study shows the experimental results of MPC control of an office building in Berkeley, where different dynamic electricity price profiles were used in the MPC objective function to shift the building load and to calculate hypothetical electricity costs. Results show potential 50% cost savings with respect to the existing controller with the dynamic price scenario.

Zanetti, Ettore↗

SolarPlus Optimizer: Integrated Control of Solar, Batteries, and Flexible Loads for Small Commercial Buildings

Building-level microgrids may be a key strategy to unlock the combined potential of flexible loads, renewable generation, and energy storage. However, few software options exist for integrated control of building loads and other distributed energy resources at this scale. The commercial software solutions on the market can force customers to adopt one particular ecosystem of products, thus limiting consumer choice. The SolarPlus Optimizer (SPO) is an open-source building-level microgrid control platform that uses Model Predictive Control to optimize both building loads and behind-the-meter energy storage to reduce energy bills and increase demand flexibility. This paper evaluates the capabilities of SPO in a small commercial building in Northern California under multiple electricity tariffs and demand response scenarios. Comparing SPO operation with an emulated battery and baseline operation employing a commercial optimization service, SPO reduced electricity bills by an estimated 7.3% in summer, 3.2% in spring, and 3.7% in winter. In a “load shape” scenario meant to counter the “duck curve”, SPO achieved 71% fewer violations from the load signal than the baseline control method. During a three hour long load shed event, SPO reduced cooling and refrigeration load by 38%. This research shows significant potential to provide load flexibility for building-level microgrids for this type of control systems. Finally, the paper discusses the future direction of research on open-source control systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Brief Update on Advancements by Commercial Vendors/Options for Feeding and Pumping Biomass Slurries for Hydrothermal Liquefaction

In 2011, Pacific Northwest National Laboratory (PNNL), working as a partner in the National Advanced Biofuels Consortium, issued a report assessing the viable industrial feed system and pump options for a 2000 dry metric tons per day production-scale hydrothermal liquefaction (HTL) plant (Berglin et al. 2012). This report was issued as PNNL-21981, Review and Assessment of Commercial Vendors/Options for Feeding and Pumping Biomass Slurries for Hydrothermal Liquefaction, and will be referred to as “Pump Survey” for reference. It had the following scope: • Identify relevant applications and industries operating at comparable scales • Interact with commercial vendors and pursue integration between vendors • Take advantage of commercial off-the-shelf (COTS) technology • Supply and support vendor needs for biomass feedstock rheology characterization • Provide vendors with process requirements to support selection of conceptual design for feedstock handing and pump system • Obtain cost data to the extent possible from equipment vendors to support the technical economic analysis (TEA) • Identify issues associated scale-up. The current document represents an update to the prior report in order to: 1. Identify advancements in vendor-reported technologies 2. List reports of new experience or trials with biomass pumping applications 3. Determine if technology/application gaps identified in the prior report have been filled 4. Capture ideas on future research.

09 BIOMASS FUELS↗

U.S. Industrial and Commercial Motor System Market Assessment Report. Volume 3: Energy Saving Opportunity

This report seeks to inform the potential for motor systems to support decarbonization by estimating their potential energy, electricity cost, and CO 2 emissions reduction potential from adoption of proven energy efficiency actions and advanced technologies. This is the third and final report in a series of reports disseminating the findings of the U.S. Department of Energy’s (DOE’s) Motor System Market Assessment (MSMA). The MSMA and this report focus on polyphase motor systems greater than or equal to 1 horsepower (hp) in the industrial and commercial sectors. In the U.S. Industrial and Commercial Motor System Market Assessment Report Volume 1: Characteristics of the Installed Base (Volume 1 report), it was determined that these motor systems consume more than 1,000 terawatt-hours (TWh) annually. This equates to 29% of the U.S. electric grid load and results in 765 million metric tons (MMT) of CO 2 emissions and $166 billion in electricity costs. This report finds that substantial reductions to these energy, cost, and emissions impacts are possible, with three areas of significant opportunity being (1) improved load matching, (2) replacing older inefficient motors with more efficient motors, and (3) improving the condition of fluid (e.g., air, water, compressed air) distribution systems. A summary of the savings potential from these three opportunities placed within the context of the overall consumption for motor systems is illustrated in Figure ES 1 (industrial) and Figure ES 2 (commercial).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗