RH-TRU [ Remote-Handled Transuranic ] Waste Content Codes (RH-TRUCON) (Rev. 10)

The Remote-Handled Transuranic (RH-TRU) Content Codes (RH-TRUCON) document describes the inventory of RH-TRU waste within the transportation parameters specified by the Remote-Handled Transuranic Waste Authorized Methods for Payload Control (RH-TRAMPAC). The RH-TRAMPAC defines the allowable payload for the RH-TRU 72-B. This document is a catalog of RH-TRU 72-B authorized contents by site. A content code is defined by the following components: (1) a two-letter site abbreviation that designates the physical location of the generated/stored waste (e.g., ID for Idaho National Laboratory [INL]); and (2) a three-digit code that designates the physical and chemical form of the waste (e.g., content code 317 denotes TRU Metal Waste). For RH-TRU waste to be transported in the RH-TRU 72-B, the first number of this three-digit code is "3." The second and third numbers of the three-digit code describe the physical and chemical form of the waste. Content codes are further defined as subcodes by an alpha trailer after the three-digit code to allow segregation of wastes that differ in one or more parameter(s). For example, the alpha trailers of the subcodes ID 322A and ID 322B may be used to differentiate between waste packaging configurations. As detailed in the RH-TRAMPAC, compliance with flammable gas limits may be demonstrated through the evaluation of compliance with either a decay heat limit or flammable gas generation rate (FGGR) limit per container specified in approved content codes. As applicable, if a container meets the watt*year criteria specified by the RH-TRAMPAC, the decay heat limits based on the dose-dependent G value may be used as specified in an approved content code.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

RH-TRU Waste Content Codes (RH-TRUCON) (Rev. 11)

The Remote-Handled Transuranic (RH-TRU) Content Codes (RH-TRUCON) document describes the inventory of RH-TRU waste within the transportation parameters specified by the Remote-Handled Transuranic Waste Authorized Methods for Payload Control (RH-TRAMPAC). The RH-TRAMPAC defines the allowable payload for the RH-TRU 72-B. This document is a catalog of RH-TRU 72-B authorized contents by site. A content code is defined by the following components: (1) a two-letter site abbreviation that designates the physical location of the generated/stored waste (e.g., ID for Idaho National Laboratory [INL]); and (2) a three-digit code that designates the physical and chemical form of the waste (e.g., content code 317 denotes TRU Metal Waste). For RH-TRU waste to be transported in the RH-TRU 72-B, the first number of this three-digit code is "3." The second and third numbers of the three-digit code describe the physical and chemical form of the waste. Content codes are further defined as subcodes by an alpha trailer after the three-digit code to allow segregation of wastes that differ in one or more parameter(s). For example, the alpha trailers of the subcodes ID 322A and ID 322B may be used to differentiate between waste packaging configurations. As detailed in the RH-TRAMPAC, compliance with flammable gas limits may be demonstrated through the evaluation of compliance with either a decay heat limit or flammable gas generation rate (FGGR) limit per container specified in approved content codes. As applicable, if a container meets the watt*year criteria specified by the RH-TRAMPAC, the decay heat limits based on the dose-dependent G value may be used as specified in an approved content code.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

RH-TRU Waste Content Codes (RH-TRUCON) (Rev. 12)

The Remote-Handled Transuranic (RH-TRU) Content Codes (RH-TRUCON) document describes the inventory of RH-TRU waste within the transportation parameters specified by the Remote-Handled Transuranic Waste Authorized Methods for Payload Control (RH-TRAMPAC). The RH-TRAMPAC defines the allowable payload for the RH-TRU 72-B. This document is a catalog of RH-TRU 72-B authorized contents by site. A content code is defined by the following components: (1) a two-letter site abbreviation that designates the physical location of the generated/stored waste (e.g., ID for Idaho National Laboratory [INL]); and (2) a three-digit code that designates the physical and chemical form of the waste (e.g., content code 317 denotes TRU Metal Waste). For RH-TRU waste to be transported in the RH-TRU 72-B, the first number of this three-digit code is "3." The second and third numbers of the three-digit code describe the physical and chemical form of the waste. Content codes are further defined as subcodes by an alpha trailer after the three-digit code to allow segregation of wastes that differ in one or more parameter(s). For example, the alpha trailers of the subcodes ID 322A and ID 322B may be used to differentiate between waste packaging configurations. As detailed in the RH-TRAMPAC, compliance with flammable gas limits may be demonstrated through the evaluation of compliance with either a decay heat limit or flammable gas generation rate (FGGR) limit per container specified in approved content codes. As applicable, if a container meets the watt*year criteria specified by the RH-TRAMPAC, the decay heat limits based on the dose-dependent G value may be used as specified in an approved content code.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

RH-TRU Waste Content Codes (RH-TRUCON) (Rev. 13)

The Remote-Handled Transuranic (RH-TRU) Content Codes (RH-TRUCON) document describes the inventory of RH-TRU waste within the transportation parameters specified by the Remote-Handled Transuranic Waste Authorized Methods for Payload Control (RH-TRAMPAC). The RH-TRAMPAC defines the allowable payload for the RH-TRU 72-B. This document is a catalog of RH-TRU 72-B authorized contents by site. A content code is defined by the following components: (1) a two-letter site abbreviation that designates the physical location of the generated/stored waste (e.g., ID for Idaho National Laboratory [INL]); and (2) a three-digit code that designates the physical and chemical form of the waste (e.g., content code 317 denotes TRU Metal Waste). For RH-TRU waste to be transported in the RH-TRU 72-B, the first number of this three-digit code is "3." The second and third numbers of the three-digit code describe the physical and chemical form of the waste. Content codes are further defined as subcodes by an alpha trailer after the three-digit code to allow segregation of wastes that differ in one or more parameter(s). For example, the alpha trailers of the subcodes ID 322A and ID 322B may be used to differentiate between waste packaging configurations. As detailed in the RH-TRAMPAC, compliance with flammable gas limits may be demonstrated through the evaluation of compliance with either a decay heat limit or flammable gas generation rate (FGGR) limit per container specified in approved content codes. As applicable, if a container meets the watt*year criteria specified by the RH-TRAMPAC, the decay heat limits based on the dose-dependent G value may be used as specified in an approved content code.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

RH-TRU Waste Content Codes (RH-TRUCON) (Rev. 14)

The Remote-Handled Transuranic (RH-TRU) Content Codes (RH-TRUCON) document describes the inventory of RH-TRU waste within the transportation parameters specified by the Remote-Handled Transuranic Waste Authorized Methods for Payload Control (RH-TRAMPAC). The RH-TRAMPAC defines the allowable payload for the RH-TRU 72-B. This document is a catalog of RH-TRU 72-B authorized contents by site. A content code is defined by the following components: (1) a two-letter site abbreviation that designates the physical location of the generated/stored waste (e.g., ID for Idaho National Laboratory [INL]); and (2) a three-digit code that designates the physical and chemical form of the waste (e.g., content code 317 denotes TRU Metal Waste). For RH-TRU waste to be transported in the RH-TRU 72-B, the first number of this three-digit code is "3." The second and third numbers of the three-digit code describe the physical and chemical form of the waste. Content codes are further defined as subcodes by an alpha trailer after the three-digit code to allow segregation of wastes that differ in one or more parameters. Examples are as follows: (1) the alpha trailers of ID 322A and ID 322D differentiate waste packaging configurations; (2) the alpha trailers of OR 321F and OR 321G differentiate shipping periods for the same waste (i.e., 60 days versus 10 days); and (3) the alpha trailers of OR 321D and OR 321H differentiate generating sources and time periods from the same waste stream, resulting in different isotopic content. As detailed in the RH-TRAMPAC, compliance with flammable gas limits may be demonstrated through the evaluation of compliance with either a decay heat limit or flammable gas generation rate (FGGR) limit per container specified in approved content codes. As applicable, if a container meets the watt*year criteria specified by the RH-TRAMPAC, the decay heat limits based on the dose-dependent G value may be used as specified in an approved content code.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

RH-TRU Waste Content Codes (RH-TRUCON) (Rev. 15)

The Remote-Handled Transuranic (RH-TRU) Content Codes (RH-TRUCON) document describes the inventory of RH-TRU waste within the transportation parameters specified by the Remote-Handled Transuranic Waste Authorized Methods for Payload Control (RH-TRAMPAC). The RH-TRAMPAC defines the allowable payload for the RH-TRU 72-B. This document is a catalog of RH-TRU 72-B authorized contents by site. A content code is defined by the following components: (1) a two-letter site abbreviation that designates the physical location of the generated/stored waste (e.g., ID for Idaho National Laboratory [INL]); and (2) a three-digit code that designates the physical and chemical form of the waste (e.g., content code 317 denotes TRU Metal Waste). For RH-TRU waste to be transported in the RH-TRU 72-B, the first number of this three-digit code is "3." The second and third numbers of the three-digit code describe the physical and chemical form of the waste. Content codes are further defined as subcodes by an alpha trailer after the three-digit code to allow segregation of wastes that differ in one or more parameters. Examples are as follows: (1) the alpha trailers of ID 322A and ID 322D differentiate waste packaging configurations; (2) the alpha trailers of OR 321F and OR 321G differentiate shipping periods for the same waste (i.e., 60 days versus 10 days); and (3) the alpha trailers of OR 321D and OR 321H differentiate generating sources and time periods from the same waste stream, resulting in different isotopic content. As detailed in the RH-TRAMPAC, compliance with flammable gas limits may be demonstrated through the evaluation of compliance with either a decay heat limit or flammable gas generation rate (FGGR) limit per container specified in approved content codes. As applicable, if a container meets the watt*year criteria specified by the RH-TRAMPAC, the decay heat limits based on the dose-dependent G value may be used as specified in an approved content code.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

RH-TRU Waste Content Codes (RH-TRUCON) (Rev. 16)

The Remote-Handled Transuranic (RH-TRU) Content Codes (RH-TRUCON) document describes the inventory of RH-TRU waste within the transportation parameters specified by the Remote-Handled Transuranic Waste Authorized Methods for Payload Control (RH-TRAMPAC). The RH-TRAMPAC defines the allowable payload for the RH-TRU 72-B. This document is a catalog of RH-TRU 72-B authorized contents by site. A content code is defined by the following components: (1) a two-letter site abbreviation that designates the physical location of the generated/stored waste (e.g., ID for Idaho National Laboratory [INL]); and (2) a three-digit code that designates the physical and chemical form of the waste (e.g., content code 317 denotes TRU Metal Waste). For RH-TRU waste to be transported in the RH-TRU 72-B, the first number of this three-digit code is "3." The second and third numbers of the three-digit code describe the physical and chemical form of the waste. Content codes are further defined as subcodes by an alpha trailer after the three-digit code to allow segregation of wastes that differ in one or more parameters. Examples are as follows: (1) the alpha trailers of ID 322A and ID 322D differentiate waste packaging configurations; (2) the alpha trailers of OR 321F and OR 321G differentiate shipping periods for the same waste (i.e., 60 days versus 10 days); and (3) the alpha trailers of OR 321D and OR 321H differentiate generating sources and time periods from the same waste stream, resulting in different isotopic content. As detailed in the RH-TRAMPAC, compliance with flammable gas limits may be demonstrated through the evaluation of compliance with either a decay heat limit or flammable gas generation rate (FGGR) limit per container specified in approved content codes. As applicable, if a container meets the watt*year criteria specified by the RH-TRAMPAC, the decay heat limits based on the dose-dependent G value may be used as specified in an approved content code.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

National Energy Code Lighting Power Limits: The Need for an Updated Calculation Process

Lighting energy codes throughout the US have become progressively more stringent due to increased interest in energy efficiency, and associated federal legislation. At the same time, the codes must, and are expected to allow for design flexibility. Historical code development for lighting has been mostly empirical with often limited observation to always make the best fit for the reality of design. With each iteration, the processes used to determine the codes and standards tries to become more closely representative of practical design and application. A natural challenge in this process is the number of variables associated with lighting design that challenges code writers to think critically about the visual needs of people, generally accepted lighting practices, and changes in the market that promote energy efficiency. Despite the issues, the code must keep designs from being wasteful and allow designers the artistic flexibility to achieve the lighting needs of the space. This paper provides a detailed look at these issues and how they affect the code development process through the development of one of the national lighting energy codes/standards. As new 2010 and beyond versions of the codes are in preparation, more detailed methods are being developed to walk that fine line between efficiency and design flexibility. The paper also explains some of the progression of the process of development of national lighting energy codes (ASHRAE/IES 90.1) and its effect on other codes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

BAYESIAN CALIBRATION OF SAFETY CODES USING DATA FROM SEPARATE-AND INTEGRAL EFFECTS TESTS

Large-scale system codes for simulation of safety performance of nuclear plants may contain parameters whose values are not known very accurately. In order to be able to use the results of these simulation codes with confidence, it is important to learn how the uncertainty on the values of these parameters affects the output of the codes. New information from tests or operating experience is incorporated into safety codes by a process known as calibration, which reduces uncertainty in the output of the safety code, and thereby improves its support for decision-making. Modern analysis capabilities afford very significant improvements on classical ways of doing calibration, and the work reported here implements some of those improvements. The key innovation has come from development of safety code surrogate model (code emulator) construction and prediction algorithms. A surrogate is needed for calibration of plant-scale simulation codes because the multivariate nature of the problem (i.e., the need to adjust multiple uncertain parameters at once to fit multiple pieces of new information) calls for multiple evaluations of performance, which, for a computation-intensive model, makes calibration very computation-intensive. Use of a fast surrogate makes the calibration processes used here with Markov Chain Monte Carlo (MCMC) sampling feasible. Moreover, most traditional surrogates do not provide uncertainty information along with their predictions, but the Gaussian Process (GP) based code surrogates used here do. This improves the soundness of the code calibration process. Results are demonstrated on a simplified scenario with data from Separate and Integral Effect Tests.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Continuous Codes and Standards Improvement (CCSI)

As of 2014, the majority of the codes and standards required to initially deploy hydrogen technologies infrastructure in the United States have been promulgated. These codes and standards will be field tested through their application to actual hydrogen technologies projects. Continuous codes and standards improvement (CCSI) is a process of identifying code issues that arise during project deployment and then developing codes solutions to these issues. These solutions would typically be proposed amendments to codes and standards. The process is continuous because as technology and the state of safety knowledge develops there will be a need to monitor the application of codes and standards and improve them based on information gathered during their application. This paper will discuss code issues that have surfaced through hydrogen technologies infrastructure project deployment and potential code changes that would address these issues. The issues that this paper will address include (1) setback distances for bulk hydrogen storage, (2) code mandated hazard analyses, (3) sensor placement and communication, (4) the use of approved equipment, and (5) system monitoring and maintenance requirements.

08 HYDROGEN↗

Computer Codes V and V Tests with a Large-Scale Sodium Thermal-Hydraulic Test Facility (STELLA)

The Korea Atomic Energy Research Institute (KAERI) is carrying out the design of a 'Prototype Generation IV Sodium-cooled Fast Reactor (PGSFR)' in cooperation with Argonne National Laboratory (ANL) in the US. In regard to computer codes V and V, a large-scale sodium thermal-hydraulic test program is currently being progressed in parallel with the PGSFR design, which is called STELLA (Sodium Test Loop for Safety Simulation and Assessment). The final objective of this program is to collect a separate and integral effect test database to validate the safety analysis codes and other thermal hydraulic design codes. In the first phase of the STELLA program, the sodium component test loop (hereafter called STELLA-1) was constructed at the KAERI site, and it has been used for performance tests of key sodium heat exchangers in PGSFR. Since this sodium test loop is basically for separate effects tests to verify the performance of key sodium components, the test database obtained from STELLA-1 has been used for the V and V of safety codes as well as heat exchanger design codes. The second phase of the program aiming at an integral effect test is called STELLA-2, which will be used for synthetic review of the key safety issues of PGSFR. The basic and detailed design phases of the STELLA-2 test facility are underway in accordance with the specific design requirements reflecting the whole design features of PGSFR. The facility installation is scheduled to be completed by 2018. Then the main experiments including the start-up tests will begin and the first integral effect test database will be constructed by the end of 2019. Based on the STELLA-2 platform, a simulation of the PGSFR transient will be made to evaluate the plant dynamic behaviors and demonstrate the decay heat removal performance. Multi-dimensional effects coming from a large sodium pool system will be identified as well. The test database obtained from the STELLA-2 experiment will be used for the validation of the safety analysis codes and other thermal hydraulics codes, and this project finally contributes to the specific design phase of PGSFR. This paper presents both the results of heat transfer tests for the key sodium heat exchangers using STELLA-1 and the first results of heat exchanger design codes V and V. The recent progress of the engineering design for the STELLA-2 test section is introduced and its specific design parameters are also presented in this paper with detailed evaluation results of their scaling distortions. A large-scale sodium thermal-hydraulic test program (STELLA) was introduced with the specific activities for separate and integral effects tests. The test database obtained from STELLA-1 was successfully used to validate both the heat exchanger design and safety analysis codes. Specific design features of the integral effects test facility (STELLA- 2) with a scaling ratio of 1/5 in length and 1/125 in volume were also presented. Validation of the STELLA-2 facility design is underway using system codes and CFD tools. Dedicated water-mockup experiments to verify the scaling design of key subsystems are currently being conducted as well. (authors)

42 ENGINEERING↗

An Integrated Partnership to Create and Lead the Solar Codes and Standards Working Group (Final Report)

The DOE grant, “An Integrated Partnership to Create and Lead the Solar Codes and Standards Working Group,” to New Mexico State University created the Solar America Board for Codes and Standards (Solar ABCs). From 2007 – 2013 with funding from this grant, Solar ABCs identified current issues, established a dialogue among key stakeholders, and catalyzed appropriate activities to support the development of codes and standards that facilitated the installation of high quality, safe photovoltaic systems. Solar ABCs brought the following resources to the PV stakeholder community; Formal coordination in the planning or revision of interrelated codes and standards removing “stove pipes” that have only roofing experts working on roofing codes, PV experts on PV codes, fire enforcement experts working on fire codes, etc.; A conduit through which all interested stakeholders were able to see the steps being taken in the development or modification of codes and standards and participate directly in the processes; A central clearing house for new documents, standards, proposed standards, analytical studies, and recommendations of best practices available to the PV community; A forum of experts that invites and welcomes all interested parties into the process of performing studies, evaluating results, and building consensus on standards and code-related topics that affect all aspects of the market; and A biennial gap analysis to formally survey the PV community to identify needs that are unmet and inhibiting the market and necessary technical developments.

14 SOLAR ENERGY↗

Cyclic codes over the ring F{sub 2}+uF{sub 2}+vF{sub 2}

In this paper, we study linear and cyclic codes over the ring F{sub 2}+uF{sub 2}+vF{sub 2}. The ring F{sub 2}+uF{sub 2}+vF{sub 2} is the smallest non-Frobenius ring. We characterize the structure of cyclic codes over the ring R=F{sub 2}+uF{sub 2}+vF{sub 2} using of the work Abualrub and Saip (Des Codes Cryptogr 42:273–287, 2007). We study the rank and dual of cyclic codes of odd length over this ring. Specially, we show that the equation |C||C{sup ⊥}|=|R|{sup n} does not hold in general for a cyclic code C of length n over this ring. We also obtain some optimal binary codes as the images of cyclic codes over the ring F{sub 2}+uF{sub 2}+vF{sub 2} under a Gray map, which maps Lee weights to Hamming weights. Finally, we give a condition for cyclic codes over R that contains its dual and find quantum codes over F{sub 2} from cyclic codes over the ring F{sub 2}+uF{sub 2}+vF{sub 2}.

97 MATHEMATICS AND COMPUTING↗

Cross-verification of the global gyrokinetic codes GENE and XGC

A detailed cross-verification between two global gyrokinetic codes, the core continuum code GENE and the edge particle-in-cell code XGC, for the linear and nonlinear simulations of ion-temperature-gradient modes is carried out. With the recent developments in the edge gyrokinetics, it may be feasible someday to describe the whole tokamak plasma on turbulence timescales using a coupled gyrokinetic simulation model. Before pursuing this, the core code (GENE) and the edge code (XGC) must be carefully benchmarked with each other. The present verification provides a solid basis for future code coupling research. Also included in the benchmarking is the global particle-in-cell code ORB5, to raise the confidence in the quality of the obtained results. An excellent agreement between all three codes is obtained. Lastly, in order to facilitate a benchmark framework for other codes, we make a specific effort to provide all the relevant input parameters and precise details for each code.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Determining the vulnerability of multi-threaded program code to soft errors

The described embodiments include a program code testing system that determines the vulnerability of multi-threaded program code to soft errors. For multi-threaded program code, two to more threads from the program code may access shared architectural structures while the program code is being executed. The program code testing system determines accesses of architectural structures made by the two or more threads of the multi-threaded program code and uses the determined accesses to determine a time for which the program code is exposed to soft errors. From this time, the program code testing system determines a vulnerability of the program code to soft errors.

97 MATHEMATICS AND COMPUTING↗

Subsystem codes with spatially local generators

We study subsystem codes whose gauge group has local generators in two-dimensional (2D) geometry. It is shown that there exists a family of such codes defined on lattices of size LxL with the number of logical qubits k and the minimum distance d both proportional to L. The gauge group of these codes involves only two-qubit generators of type XX and ZZ coupling nearest-neighbor qubits (and some auxiliary one-qubit generators). Our proof is not constructive as it relies on a certain version of the Gilbert-Varshamov bound for classical codes. Along the way, we introduce and study properties of generalized Bacon-Shor codes that might be of independent interest. Secondly, we prove that any 2D subsystem [n,k,d] code with spatially local generators obeys upper bounds kd=O(n) and d{sup 2}=O(n). The analogous upper bound proved recently for 2D stabilizer codes is kd{sup 2}=O(n). Our results thus demonstrate that subsystem codes can be more powerful than stabilizer codes under the spatial locality constraint.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Best practices for building energy codes compliance

Building energy codes are a proven policy mechanism to achieve economy-wide energy savings in buildings. In 2021, the International Energy Agency Energy in Buildings and Communities Programme (IEA EBC) Building Energy Codes Working Group (BECWG) set out to survey the diverse codes compliance practices across BECWG member countries. While codes vary in format and approach, attaining the energy reduction potential of building energy codes requires effective implementation and compliance. This is a large undertaking for countries, as effective compliance checking requires adequate resources, technical knowledge, capacity, and strong institutions. Many nations face the same compliance issues, such as requiring faster and easier methods to verify codes and coordinating among numerous stakeholders and levels of government. This paper explores the need for stronger institutional approaches to enforce building energy codes that will lead to code compliance. Specifically, this report sets out to address the question of what practices result in effective building energy code compliance in selected BECWG member countries.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Linear and nonlinear verification of gyrokinetic microstability codes

Verification of nonlinear microstability codes is a necessary step before comparisons or predictions of turbulent transport in toroidal devices can be justified. By verification we mean demonstrating that a code correctly solves the mathematical model upon which it is based. Some degree of verification can be accomplished indirectly from analytical instability threshold conditions, nonlinear saturation estimates, etc., for relatively simple plasmas. However, verification for experimentally relevant plasma conditions and physics is beyond the realm of analytical treatment and must rely on code-to-code comparisons, i.e., benchmarking. The premise is that the codes are verified for a given problem or set of parameters if they all agree within a specified tolerance. True verification requires comparisons for a number of plasma conditions, e.g., different devices, discharges, times, and radii. Running the codes and keeping track of linear and nonlinear inputs and results for all conditions could be prohibitive unless there was some degree of automation. We have written software to do just this and have formulated a metric for assessing agreement of nonlinear simulations. We present comparisons, both linear and nonlinear, between the gyrokinetic codes GYRO[J. Candy and R. E. Waltz, J. Comput. Phys. 186, 545 (2003)] and GS2[W. Dorland, F. Jenko, M. Kotschenreuther, and B. N. Rogers, Phys. Rev. Lett. 85, 5579 (2000)]. We do so at the mid-radius for the same discharge as in earlier work [C. Holland, A. E. White, G. R. McKee, M. W. Shafer, J. Candy, R. E. Waltz, L. Schmitz, and G. R. Tynan, Phys. Plasmas 16, 052301 (2009)]. The comparisons include electromagnetic fluctuations, passing and trapped electrons, plasma shaping, one kinetic impurity, and finite Debye-length effects. Results neglecting and including electron collisions (Lorentz model) are presented. We find that the linear frequencies with or without collisions agree well between codes, as do the time averages of the nonlinear fluxes without collisions. With collisions, the differences between the time-averaged fluxes are larger than the uncertainties defined as the oscillations of the fluxes, with the GS2 fluxes consistently larger (or more positive) than those from GYRO. However, the electrostatic fluxes are much smaller than those without collisions (the electromagnetic energy flux is negligible in both cases). In fact, except for the electron energy fluxes, the absolute magnitudes of the differences in fluxes with collisions are the same or smaller than those without. None of the fluxes exhibit large absolute differences between codes. Beyond these results, the specific linear and nonlinear benchmarks proposed here, as well as the underlying methodology, provide the basis for a wide variety of future verification efforts.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗