Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CoP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Development of High Efficiency Carbon Dioxide Commercial Heat Pump Water Heater

Although heat pump water heaters are today widely accepted in both Japan and Europe, where energy costs are high and government incentives for their use exist, acceptance of such products in the US has been limited. While this trend is slowly changing with the introduction of heat pump water heaters into the residential market, but acceptance remains low in the commercial sector. The objective of the presented work is the development of a high efficiency R744 heat pump water heater for commercial applications with effective utilization of the cooling capability for air conditioning and/or refrigeration. The ultimate goal is to achieve total system COP of up to 8. This unit will be targeted at commercial use where some cooling load is typically needed year round, such as restaurants, hotels, nursing homes, and hospitals. This paper presents the performance results from the development of four R744 commercial heat pump water heater packages of approximately 35 kW and comparison to a commercially available baseline R134a unit of the same capacity and footprint. In addition, the influences of an internal heat exchanger and an enhanced evaporator on the system performance are described and recommendations are made for further improvements of the R744 system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design and Fabrication of a Precious Metal‐Free Tandem Core–Shell p + n Si/W‐Doped BiVO 4 Photoanode for Unassisted Water Splitting

Abstract Tandem photoelectrochemical water splitting cells utilizing crystalline Si and metal oxide photoabsorbers are promising for low‐cost solar hydrogen production. This study presents a device design and a scalable fabrication scheme for a tandem heterostructure photoanode: p + n black silicon (Si)/SnO 2 interface/W‐doped bismuth vanadate (BiVO 4 )/cobalt phosphate (CoPi) catalyst. The black‐Si not only provides a substantial photovoltage of 550 mV, but it also serves as a conductive scaffold to decrease charge transport pathlengths within the W‐doped BiVO 4 shell. When coupled with cobalt phosphide (CoP) nanoparticles as hydrogen evolution catalysts, the device demonstrates spontaneous water splitting without employing any precious metals, achieving an average solar‐to‐hydrogen efficiency of 0.45% over the course of an hour at pH 7. This fabrication scheme offers the modularity to optimize individual cell components, e.g., Si nanowire dimensions and metal oxide film thickness, involving steps that are compatible with fabricating monolithic devices. This design is general in nature and can be readily adapted to novel, higher performance semiconducting materials beyond BiVO 4 as they become available, which will accelerate the process of device realization.

Chakthranont, Pongkarn↗

Advanced trust region optimization strategies for glass box / black box models

We present an improved trust region filter (TRF) method for optimization of combined glass box/black box systems. Glass box systems refer to models that are easily expressed in an algebraic modeling language, providing cheap and accurate derivative information. By contrast, black box systems may be computationally expensive and derivatives are unavailable. The TRF method, as first introduced in our previous work (Eason and Biegler, AIChE J . 2016; 62:3124–3136), is able to handle hybrid systems containing both glass and black box components, which can frequently arise in chemical engineering, for example, when a multiphase reactor model is included in a flow sheet optimization problem. We discuss several recent modifications in the algorithm such as the sampling region, which maintains the algorithm's global convergence properties without requiring the trust region to shrink to zero in the limit. To benchmark the development of this optimization method, a test set of problems is generated based on modified problems from the CUTEr and COPS sets. The modified algorithm demonstrates improved performance using the test problem set. Finally, the algorithm is implemented within the Pyomo environment and demonstrated on a rigorous process optimization case study for carbon capture. © 2018 American Institute of Chemical Engineers AIChE J , 64: 3934–3943, 2018

Eason, John P.↗

Multimodal, microspectroscopic speciation of legacy phosphorus in two US mid-Atlantic agricultural soils

To understand phosphorus (P) mobility in agricultural soils and its potential environmental risk, it is essential to directly measure solid phase P speciation. Often, bulk P K-edge X-ray absorption near edge structure (XANES) spectroscopy followed by linear combination fitting (LCF) is utilized to determine the solid P phases in soil. However, this method may limit results to only a few major phases. Additionally, XANES spectra for different P species may have very similar features, leading to an over- or underestimate of their contribution to LCF. Here, an improved P speciation by pairing multimodal microbeam-X-ray fluorescence (µ-XRF) mapping coupled with µ-XANES (microbeam-X-ray absorption near edge structure) analysis to directly speciate major and minor P phases on the micron scale is provided. We combined maps of both tender (P, sulfur, aluminum, and silicon) and hard energy (calcium, iron [Fe], and manganese) elements to evaluate the elemental co-locations with P. To better account for uncertainty assigning XANES peaks to individual compounds, a more quantitative fingerprinting by “spectral feature analysis” was completed. With this analysis, an R-factor is reported for the fit. These results were compared to traditional LCF. Pre-edge fitting results revealed the presence of a two-component pre-edge feature for phosphate adsorbed to ferrihydrite. Additionally, phytate co-precipitated with ferrihydrite (Phytate-Fe-Cop) had a pre-edge feature, indicating direct association with Fe. Lastly, a unique P species associated with manganese oxide was identified in the soil via multimodal mapping and µ-XANES. These results allow for better prediction of P dissolution and mobility.

36 MATERIALS SCIENCE↗

AC Susceptibility of BaZrO{sub 3} Nanoparticles Added YBa{sub 2}Cu{sub 3}O{sub 7−δ} Superconductor Prepared via Coprecipitation Method

In this work, magnetic properties of polycrystalline samples YBa{sub 2}Cu{sub 3}O{sub 7−δ} added with x mol.% of BaZrO{sub 3} (BZO) nanoparticles (x = 0.0, 1.0, 2.0, 3.0, 5.0, and 7.0) were studied by AC susceptibility (ACS) measurement. The samples were prepared using coprecipitation (COP) method. X-ray diffraction (XRD) results showed that all the samples were composed of Y-123 as the major phase and Y-211 as the secondary phase. XRD peak of BZO was also observed in the samples added with BZO nanoparticles. The intensity of the peak became higher with increasing amount of BZO addition indicating the presence of increased amount of the unreacted nanoparticles in the samples. The refined lattice parameters indicated that all the samples have an orthorhombic crystal structure without the occurrence of orthorhombic-tetragonal phase transformation. Scanning electron microscopy (SEM) images showed that the samples have randomly distributed grains with irregular shape. The average grain size increased from 0.30 μ m for the pure sample to 0.50 μ m for the BZO addition of 7.0 mol.%. ACS measurement showed a slight decrease of onset critical temperature, T{sub c−onset} (< 1 K) with BZO addition. Both phase lock-in temperature, T{sub cj}, and coupling peak temperature, T{sub p}, remained relatively unchanged for BZO addition up to 3.0 mol.%. Based on the Bean critical state model, the calculated intergranular critical current density, J{sub cm}, for the pure sample is 1.88 A/cm{sup 2} at T{sub p} = 84.8 K. For the sample added with 7.0 mol.% of BZO, J{sub cm} at T{sub p} = 83.6 K is 1.95 A/cm{sup 2}.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Effect of Synthesis Approaches and Morphological Properties on Dielectric Enhancement and Microwave Absorption of Fe{sub 3}O{sub 4}/PANI Nanocomposites

In the present work, Fe{sub 3}O{sub 4} spherical (Fe{sub 3}O{sub 4}-cop) and raspberry-like (Fe{sub 3}O{sub 4}-hyd) nanoparticles were synthesized via co-precipitation and hydrothermal routes, respectively. Fe{sub 3}O{sub 4}/polyaniline (PANI) nanocomposites were prepared by in situ oxidative polymerization of aniline monomer in the presence of the Fe{sub 3}O{sub 4} materials. Characterization of the nanocomposites by XRD, FT-IR, FESEM, and TEM techniques revealed a core/shell structure for Fe{sub 3}O{sub 4}-hyd/PANI, unlike the PANI blocks with embedded Fe{sub 3}O{sub 4} and γ-Fe{sub 2}O{sub 3} observed in Fe{sub 3}O{sub 4}-cop/PANI composites. The larger and pure magnetite nanoparticles produced with the hydrothermal process and the respective nanocomposite with PANI possess higher magnetization and coercivity values, according to the magnetic investigation with VSM. Moreover, according to the electromagnetic characterization in the X-band, the Fe{sub 3}O{sub 4}-hyd/PANI nanocomposite exhibits the highest complex permittivity level, as a consequence of increased interfacial polarization in the Fe{sub 3}O{sub 4}-hyd/PANI system. On this account, reflection loss measurements have shown the superior microwave absorption capability of Fe{sub 3}O{sub 4}-hyd/PANI composite, compared with Fe{sub 3}O{sub 4}-cop/PANI, with a measured maximum of −31.28 dB at 8.5 GHz for 3.5 mm layer thickness.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Ionic liquid-based hybrid absorption cycle for water heating, dehumidification, and cooling

Water heating, dehumidification and space cooling are responsible for significant energy consumption in buildings. A potential energy saving measure is to develop hybrid systems that can utilize the sensible and latent heats removed in space cooling to heat water. In this paper, we present experimental results on a hybrid system that utilizes the latent heat released in the dehumidification process for water heating. This system absorbs water vapor from the air and transfers the heat of phase change into the process water. The absorbed water vapor is then liberated in a desorber and subsequently condensed in a condenser, while its latent heat is transferred to the process water. The condensed water vapor can then be either drained (if dehumidification is desired), or utilized in an evaporative cooling process (if sensible space cooling is desired). In essence, the system can exchange both sensible and latent heats with its ambient. The main innovations implemented in the system are (1) a semi-open absorption system architecture to lower the system cost, (2) a membrane-based absorber to alleviate the liquid entrainment issue encountered in the conventional packed bed absorbers and (3) an ionic liquid that eliminates the crystallization risks and minimizes corrosion issues normally associated with LiBr-based absorption systems. Furthermore, a water heating thermal COP of 1.4 is achieved at 30°C, 70% RH ambient conditions.

42 ENGINEERING↗

Investigation of a high-temperature combination heat pump for lower-cost electrification in multifamily buildings

The development of space and water heating combination heat pumps capable of generating water temperatures high enough for convective heat emitters will enable more cost-effective and equitable decarbonization solutions for electrifying multifamily buildings. Here, in this paper, multifamily building models and a charge-sensitive mechanistic cycle model of a combination heat pump are developed, and the system performance is predicted based on the models. Unlike other state-of-the-art residential heat pumping equipment, the modeled combination heat pump using an economized, fluid-injected variable-speed compressor can achieve higher temperature lifts of 40° - 85°C, with lower installation costs and complexity. The model predicted heating coefficient of performance (COP h ) is 2.1 at an ambient temperature of -15°C with a high-temperature lift of nearly 85°C, and a seasonal coefficient of performance in heating mode (SCOP h ) ranges from 2 - 4 for different locations. The system shows 30% - 90% lower CO 2 eq emissions over a condensing gas boiler and 9% - 13% lower projected installation costs than two separate space and water heat pumping appliances.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simulation of a High Efficiency Multi-bed Adsorption Heat Pump

Attaining high energy efficiency with adsorption heat pumps is challenging due to thermodynamic losses that occur when the sorbent beds are thermally cycled without effective heat recuperation. The multi-bed concept described here effectively transfers heat from beds being cooled to beds being heated, which enables high efficiency in thermally driven heat pumps. A simplified lumped-parameter model and detailed finite element analysis are used to simulate the performance of an ammonia-carbon sorption compressor, which is used to project the overall heat pump coefficient of performance. The effects of bed geometry and number of beds on system performance are explored, and the majority of the performance benefit is obtained with four beds. Results indicate that a COP of 1.24 based on heat input is feasible at AHRI standard test conditions for residential HVAC equipment. When compared on a basis of primary energy input, performance equivalent to SEER 13 or 14 are theoretically attainable with this system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Numerical and experimental analysis of precooled desiccant system

This paper presents a numerical and experimental study of four novel, desiccant air-conditioning systems based on pre-cooling of the ambient air. The purpose of the study is to: 1) establish which configuration is most profitable for the future studies through numerical and experimental methods; 2) verify the concept of precooled system and confirm that it is working in experimental conditions (for this purpose two prototypes of evaporative cooling units were developed and compared for different operation arrangements with desiccant wheel); 3) Analyze practical aspects of the systems, which includes water consumption analysis, economic analysis and establishing operational modes during a cooling season in temperate climate conditions (the proposed solution has a significant advantage during operation in a temperate climate, since it can utilize its first evaporative cooler the only source of cooling energy when the humidity of outdoor air allows to to meet the latent cooling load). Four arrangements of the system with different dew point evaporative air cooler prototypes were selected and developed for comparative analysis. The system was simulated as a whole, also, each component was individually tested on measurement station. develop the optimal arrangement of the system through numerical and experimental analysis. Four different performance indicators were considered: thermal COP (Coefficient Of Performance), the ERR (Energy Efficiency Ratio), coefficient a describing the potential in compensating indoor cooling loads, water consumption ratio. Also costs of the systems were compared through economic analysis. It was established that arrangement which is characterized by best-averaged performance in terms of all considered factors is a unit combined with two different types of evaporative coolers (marked as System B)- this is caused by the favorable arrangement of two units, where one is better suited to the pre-cooler role, while the other is better suited as the post-cooler.

42 ENGINEERING↗

Performance evaluation of a wrapped around condenser for heat pump water heater applications

In this report, accurate performance evaluation of a wrapped-around condenser for heat pump water heaters (WHPWH) is critical since the COP of the system depends heavily on thermal stratification and condenser design. An analytical, quasi-steady state heat balance method has been developed to determine the optimal spacing between adjacent channels, tube diameter, tube shape, and total refrigerant charge amount for the condenser. The heat transfer rate is compared among three approaches: the refrigerant thermodynamic model, the condenser-wrap fin model, and the analytical natural convection model on the inside of the tank for the three regions based on the refrigerant phase (e.g., super-heated, saturated, or subcooled). The heat transfer rate was predicted by a combination of slug-plug and annular flow for a D-shaped helical tube. Experimental data were used as boundary conditions for validating the model. The rate of heat transfer based on tube shape and tank wall temperatures was compared by CFD analysis. Parametric analysis indicates a tradeoff between refrigerant mass, pressure drop, tube diameter, and tube length to maximize the heat transfer rate. The model suggests the saturated region length can be extended by 400%, and the condenser pressure drop can be reduced by 23% with an optimal spacing pattern.

42 ENGINEERING↗

A critical review of electrochemical heat pump technologies: Status, challenges, and perspectives

The development of advanced heat pump technologies is critical for reducing global energy consumption in the building sector, where space heating and cooling account for nearly 50% of energy use. Electrochemical heat pumps (EHPs) offer a promising alternative to vapor compression systems by enabling direct electrochemical-to-thermal energy conversion, often with environmentally benign working fluids that exhibit low or zero global warming potential (GWP). Prior literature has predominantly focused on chemically reactive heat pumps, while comprehensive assessments of electrochemical mechanisms remain limited. Here, this review addresses this gap by systematically evaluating the underlying principles, architectures, and performance metrics of EHP systems. Compared to conventional vapor compression systems, EHPs can achieve 10%-30% higher energy efficiency, with reported cooling coefficients of performance (COP c ) ranging from 3.5 to 14.3 under standard operating conditions. Despite these advantages, widespread adoption is hindered by challenges including membrane degradation, electrode fouling, sluggish redox kinetics, and elevated system-level capital costs. To address these limitations, the review outlines three research priorities: (i) the development of advanced membranes, catalysts, and electrode materials with enhanced chemical and mechanical stability; (ii) the application of molecular-level simulations for the rational design of high-performance redox-active working fluids; and (iii) the integration of advanced diagnostic techniques for real-time monitoring and sustained operation of EHPs. By consolidating recent advances and explicitly identifying technological and scientific gaps, this work uniquely contributes a comprehensive framework for guiding future electrochemical heat pump research and facilitating the transition to sustainable thermal management technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integration of a thermoelectric subcooler with an air‑source heat pump to enhance heating capacity and dehumidification

This study presents an innovative configuration of a thermoelectric subcooler (TES) integrated with an air-source heat pump (ASHP). The TES is installed in the liquid line, where it absorbs heat from the refrigerant. On its hot side, it discharges heat to the return air in heating mode or to the supply air in cooling mode, enabling year-round operation. The ASHP–TES system was evaluated under various conditions to reduce supplemental heating needs and improve dehumidification. Experimental heating tests revealed that activating the TES increased the heating capacity by 12%–20%. However, this occurred with a 7.6%–10% reduction in heating coefficient of performance (COP). In cooling mode, TES operation significantly improved moisture removal. The TES reduced the sensible heat ratio (SHR) and enhanced dehumidification, removing 20%–50% more moisture than a conventional system when meeting the same sensible load. The TES can be turned off to use the refrigerant subcooler for reheat supply air or turned on to substantially boost dehumidification. When meeting the same latent load, the ASHP–TES system achieved up to 33% energy savings compared with a conventional ASHP using resistance heating. Relative to a conventional ASHP paired with a whole-house dehumidifier, the ASHP–TES system provided up to 20% energy savings. These findings underscore the potential of TES integration to improve latent load control and enhance overall energy efficiency in hybrid ASHP systems, especially in cold and humid climates.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

Theoretical analysis of a refrigerant injection-enhanced air source heat pump with thermal energy storage for extended cold-climate and defrosting operations

This study investigates a conceptual refrigerant injection-enhanced air source heat pump with integrated thermal energy storage (ITES-ASHP) that combines two-phase flash tank injection with phase change material (PCM) thermal energy storage (TES) to extend cold-climate operation and maintain indoor heating during defrost. A steady-state, mode-based thermodynamic cycle model is developed to evaluate heating and defrosting modes with and without refrigerant injection and TES integration over an outdoor temperature range of 8 to −25 °C. The framework is applied to refrigerants R-290, R-454B, R-410 A, and R-32. A parametric study is conducted for an 18-kW system rated for an outdoor temperature of 8 °C, with the compressor frequency scheduled to 150 Hz. The optimal PCM phase-change temperature is identified as 20 °C for R-290, R-454B, and R-410 A, and 15 °C for R-32. At the design condition of −25 °C outdoor temperature, the proposed concept achieves a combined COP of 2.22 for R-290, corresponding to a 60% increase relative to the theoretical single-stage baseline for combined heating and defrosting operation. Safety screening based on compressor discharge temperature (≤ 120 °C) and injection quality (≥ 0.65), together with performance evaluation, indicates that R-290 is the most suitable candidate, followed by R-410 A and R-454B. Under the assumptions and constraints used here, R-32 is found to be less suitable due to excessive discharge temperatures and a higher risk of wet compression.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The binding of TBK1 to STING requires exocytic membrane traffic from the ER

Highlights: • Blocking ER-to-Golgi traffic inhibited the binding of TBK1 to STING. • Endogenous TBK1 was recruited to the Golgi upon stimulation of STING. • Disease-causative STING variants bound to TBK1 at the Golgi not at the ER. Stimulator of interferon genes (STING) is essential for the type I interferon and pro-inflammatory responses against DNA pathogens. In response to the presence of cytosolic DNA, STING translocates from the endoplasmic reticulum (ER) to the Golgi, and activates TANK-binding kinase 1 (TBK1), a cytosolic kinase that is essential for the activation of STING-dependent downstream signalling. The organelles where TBK1 binds to STING remain unknown. Here we show that TBK1 binds to STING at the Golgi, not at the ER. Treatment with brefeldin A, an agent to block ER-to-Golgi traffic, or knockdown of Sar1, a small GTPase that regulates coat protein complex II (COP-II)-mediated ER-to-Golgi traffic, inhibited the binding of TBK1 to STING. Endogenous TBK1 was recruited to the Golgi when STING was transported to the Golgi, as shown by immunofluorescence microscopy. STING variants that constitutively induce the type I interferon response were found in patients with autoinflammatory diseases. Even these disease-causative STING variants could not bind to TBK1 when the STING variants were trapped in the ER. These results demonstrate that the Golgi is an organelle at which STING recruits and activates TBK1 for triggering the STING-dependent type I interferon response.

60 APPLIED LIFE SCIENCES↗

Thermal comfort evaluated for combinations of energy-efficient personal heating and cooling devices

Personal comfort systems (PCS) have potential to fulfill building occupants' personal thermal comfort preferences with great efficiency. But to integrate them into building conditioning, there must be a broader selection of PCS devices available. Design guidance and standards are needed to assure that such devices provide high levels of comfort effectiveness and energy efficiency. This study addresses these needs. A suite of minimum-power PCS devices was built that target body parts significant to alliesthesia—a heated shoe insole, heated/cooled wristpad, small deskfan, and heated/cooled chair. They were tested in a climate chamber under cool and warm conditions using both thermal-manikin and human-subjects. Their efficiency at physically heating/cooling the body is high; the combined suite has a coefficient of performance (COP) of 3.6 for cooling and 0.88 for heating. The subjects' whole-body thermal acceptance and thermal comfort perception were improved by the devices in an additive manner; using the combined suite over 80% of people accepted ambient temperatures of 18°C and 29°C. The PCS ‘corrects’ the ambient temperature towards thermal neutrality by as much as 6.5 K cooling and 3.6 K heating, overcoming building occupants' typical interpersonal thermal differences and making possible large HVAC energy savings in buildings. The idea of temperature corrective power can be the basis of standards for PCS.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A prototype cooling blanket for mitigating occupant overheating risk in a hot indoor environment: Modeling and assessments

Conventional ways of cooling a room or an entire house for occupant thermal comfort during summer consume a significant amount of energy and are vulnerable to overheating risk during power outages that lead to loss of cooling system operations. This study investigates a low-power cooling blanket, as a Personal Cooling System (PCS), that covers the upper human body for direct cooling during a five-day heat wave in a single-family house. A modeling framework is developed for evaluating the thermal and energy performance of the cooling blanket, which builds upon the co-simulation of three models: a house energy model, a personal thermal comfort model, and a cooling blanket model. Simulation results show that under the power outage scenario, the cooling blanket can greatly reduce the occupant heat stress with a reduction of daily hours of exceedance (discomfort hours defined as TSV>2) by up to 17.2 h (a 95.3 % improvement from the baseline power outage without the blanket). The cooling blanket, equipped with an innovative electrocaloric heat pump (COP as high as 10.1) consumes 6.31 W and can be operated by a portable battery for several days. The cooling blanket consumes only 0.28 % of the electricity of a central air-conditioning system running to provide cooling for the whole house during the five-day heatwave period. The findings justify further research of electrocaloric wearable PCS as low-power effective cooling to ensure thermal survivability of occupants during extreme indoor environments.

Electrocaloric heat pump↗