Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Clean room”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Adsorption of oxygen on W/100/ - Adsorption kinetics and structure

The adsorption of oxygen on W(100) single-crystal surfaces is studied by Auger electron spectroscopy (AES), flash desorption, low-energy electron diffraction (LEED), and retarding-field work-function measurements. The AES results reveal stepwise changes in the sticking coefficients in the coverage range 0 to 1 and activated adsorption at higher coverages. Upon room-temperature adsorption, a series of complex LEED patterns is observed. In layers adsorbed at 1050 K and cooled to room temperature, the p(2 x 1) structure is the first ordered structure observed. This structure shows a reversible order-disorder transition between 700 and 1000 K and is characterized by a work function which is lower than that of the clean surface. Heating room-temperature adsorbates changes their structure irreversibly. At temperatures below 750 K, some new structures are observed.

Bauer, E.↗

Surface characterization of hydrogen charged and uncharged alpha-2 and gamma titanium aluminide alloys using AES and REELS

The surfaces of selected uncharged and hydrogen charged alpha-2 and gamma titanium aluminide alloys with Nb additions were characterized by Auger electron (AES) and reflected electron energy loss (REELS) spectroscopy. The alloy surfaces were cleaned before analysis at room temperature by ion sputtering. The low energy (500 eV) ion sputtering process preferentially sputtered the surface concentration. The surface concentrations were determined by comparing AES data from the alloys with corresponding data from elemental references. No differences were observed in the Ti or Nb Auger spectra for the uncharged and hydrogen charged alloys, even though the alpha-2 alloy had 33.4 atomic percent dissolved hydrogen. Also, no differences were observed in the AES spectra when hydrogen was adsorbed from the gas phase. Bulk plasmon energy shifts were observed in all alloys. The energy shifts were induced either by dissolved hydrogen (alpha-2 alloy) or hydrogen adsorbed from the gas phase (alpha-2 and gamma alloys). The adsorption induced plasmon energy shifts were greatest for the gamma alloy and cp-Ti metal.

Shanabarger, M. R.↗

Fabrication method for a room temperature hydrogen sensor

A sensor for selectively determining the presence and measuring the amount of hydrogen in the vicinity of the sensor. The sensor comprises a MEMS device coated with a nanostructured thin film of indium oxide doped tin oxide with an over layer of nanostructured barium cerate with platinum catalyst nanoparticles. Initial exposure to a UV light source, at room temperature, causes burning of organic residues present on the sensor surface and provides a clean surface for sensing hydrogen at room temperature. A giant room temperature hydrogen sensitivity is observed after making the UV source off. The hydrogen sensor of the invention can be usefully employed for the detection of hydrogen in an environment susceptible to the incursion or generation of hydrogen and may be conveniently used at room temperature.

Seal, Sudipta↗

Analysis of strategies to meet ASHRAE S241 infectious aerosol control targets by space type and region using EnergyPlus™ simulations

Professional organizations, such as ASHRAE, have recently proposed new voluntary standards for controlling infectious aerosols. Specifically, ASHRAE Standard 241 (S241) defines equivalent clean air targets for a range of space types that can be met through combinations of mitigation measures. This paper seeks to inform the selection of measures by space type and climate zone through building simulations that quantify the impacts of increased outdoor air ventilation; increasing filtration and/or adding germicidal ultraviolet (GUV) in the central heating, ventilation, and air-conditioning (HVAC) systems; or using portable air cleaners (PACs), upper room GUV, or whole room GUV approaches to increase equivalent clean air delivery. The measures are assessed individually and in practical combinations for their ability to meet S241 in four space types (offices, classrooms, dining areas, and healthcare waiting rooms) using prototype buildings modeled using EnergyPlus. The mitigation measures are compared holistically against baseline building operations using metrics for equivalent clean air, energy, and comfort. The results in this study show that single measures can meet S241 for offices with minimal impacts on energy and comfort, while either upper room GUV systems or combinations of measures such as MERV 13 HVAC filtration with PACs are needed to meet S241 for classrooms. The dining area and healthcare waiting room targets cannot be met in this study when assuming design occupancy and MS2 as the challenge agent, even when combining multiple measures together. This paper provides valuable considerations when designing measures to meet S241 for a range of spaces and scenarios.

GUV↗

Environmental monitoring of the orbiter payload bay and Orbiter Processing Facilities

Contamination control in the Orbiter Processing Facility (OPF) is studied. The clean level required in the OPF is generally clean, which means no residue, dirt, debris, or other extraneous contamination; various methods of maintaining this level of cleanliness are described. The monitoring and controlling of the temperature, relative humidity, and air quality in the OPF are examined. Additional modifications to the OPF to improve contamination control are discussed. The methods used to maintain the payload changeout room at a level of visually clean, no particulates are to be detected by the unaided eye, are described. The payload bay (PLB) must sustain the cleanliness level required for the specific Orbiter's mission; the three levels of clean are defined as: (1) standard, (2) sensitive, and (3) high sensitive. The cleaning and inspection verification required to achieve the desired cleanliness level on a variety of PLB surface types are examined.

Bartelson, D. W.↗

Comparison of effectiveness and energy use of airborne pathogen mitigation measures to meet clean air targets in a prototypical office building

Organizations such as ASHRAE and the Centers for Disease Control and Prevention (CDC) have proposed guidelines for controlling infectious aerosols in buildings, which can be met through measures such as modified operation of the heating, ventilation, and air-conditioning (HVAC) system or incorporating air-cleaning technologies. However, more research is needed to understand the trade-offs between health, energy, and comfort aspects when designing measures for these guidelines. To address this gap, this paper presents an analysis using new models for air-cleaning technologies, including in-duct and in-room germicidal ultraviolet (GUV) systems and portable air cleaners (PACs). These models are incorporated into an existing prototypical office building model and six measures are designed to meet ASHRAE Standard 241 and CDC clean air targets: MERV 13 HVAC filtration, maximum outdoor air supplied to the building, PACs, and in-duct, upper-room, and whole-room GUV. The measures are simulated for an office building in a cool and humid climate compared against a baseline simulation using MERV 8 filtration. The results show that all measures, except for the maximum outdoor air case, can meet the ASHRAE 241 standard without significant impacts on energy or comfort. The HVAC system measures were not able to meet the CDC target with the default system sizing and lead to significant energy increases, while the in-room measures were able to meet the CDC target with small impacts on energy consumption. Finally, this paper consolidates the simulation findings and provides practical guidance for building operators to meet clean air targets while limiting energy and comfort impacts.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evolution of the Lunar Receiving Laboratory to the Astromaterial Sample Curation Facility: Technical Tensions Between Containment and Cleanliness, Between Particulate and Organic Cleanliness

The Lunar Receiving Laboratory (LRL) was planned and constructed in the 1960s to support the Apollo program in the context of landing on the Moon and safely returning humans. The enduring science return from that effort is a result of careful curation of planetary materials. Technical decisions for the first facility included sample handling environment (vacuum vs inert gas), and instruments for making basic sample assessment, but the most difficult decision, and most visible, was stringent biosafety vs ultra-clean sample handling. Biosafety required handling of samples in negative pressure gloveboxes and rooms for containment and use of sterilizing protocols and animal/plant models for hazard assessment. Ultra-clean sample handling worked best in positive pressure nitrogen environment gloveboxes in positive pressure rooms, using cleanable tools of tightly controlled composition. The requirements for these two objectives were so different, that the solution was to design and build a new facility for specific purpose of preserving the scientific integrity of the samples. The resulting Lunar Curatorial Facility was designed and constructed, from 1972-1979, with advice and oversight by a very active committee comprised of lunar sample scientists. The high precision analyses required for planetary science are enabled by stringent contamination control of trace elements in the materials and protocols of construction (e.g., trace element screening for paint and flooring materials) and the equipment used in sample handling and storage. As other astromaterials, especially small particles and atoms, were added to the collections curated, the technical tension between particulate cleanliness and organic cleanliness was addressed in more detail. Techniques for minimizing particulate contamination in sample handling environments use high efficiency air filtering techniques typically requiring organic sealants which offgas. Protocols for reducing adventitious carbon on sample handling surfaces often generate particles. Further work is needed to achieve both minimal particulate and adventitious carbon contamination. This paper will discuss these facility topics and others in the historical context of nearly 50 years' curation experience for lunar rocks and regolith, meteorites, cosmic dust, comet particles, solar wind atoms, and asteroid particles at Johnson Space Center.

Allton, J. H.↗

eGridGPT: Trustworthy AI in the Control Room

This report outlines the synergy between human decision making and generative artificial intelligence (GenAI), where GenAI supports power system operators by analyzing procedures, suggesting actions, simulating scenarios with physics-based digital twins, and recommending optimal decisions. This report is the first research effort to apply large language models (LLMs), a type of GenAI, in the power grid control room. The authors describe the Electric Grid Generative Pretrained Transformer (eGridGPT), an LLM that virtually assists system operators. Developed with cybersecurity and regulatory requirements in mind, eGridGPT represents an opportunity to responsibly evolve control room technologies to meet the needs of a rapidly changing grid. As an innovative concept, eGridGPT seeks to spearhead productive discussions about the advanced technologies in the control room of the future amid the transition to clean energy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Nafion Passivation of c-Si Surface and Edge for Electron Paramagnetic Resonance

Effective surface passivation of crystalline silicon (c-Si) surface by reducing the carrier recombination rate has led to modern c-Si solar cells with efficiencies > 25% in both laboratory and industrial settings. Typical mainstream surface passivation techniques include high-temperature silicon oxide (SiOx), amorphous silicon (a-Si:H), hydrogen-rich silicon nitride (SiNx), and aluminum oxide (Al2O3) [1]. They have demonstrated excellent surface recombination velocity of < 1 cm/s owing to both chemical passivation (via the hydrogen saturation of Si dangling bonds at the c-Si surface), and field-effect passivation (via the band bending from the fixed charge of the dielectric layers). Recently, several groups have studied solution-based organic materials for c-Si passivation, including bis(trifluoromethane)sulfonimide (TFSI), polystyrenesulfonate, and Nafion [2, 3] via spin or dip coating. All films were processed at ambient room temperature, and a high lifetime of 12 ms, as well as a low saturation current density (J0) of 16 fA/cm2, have been demonstrated using Nafion passivation [2]. However, despite the air instability, Nafion has several advantages when introduced to PV applications: (a) Wafer quality can be measured at high throughput after several process stages. (b) It is compatible with PL mapping, compared to HF liquid passivation which cannot be performed in room ambient. (c) Nafion process is fast and poses fewer constraints on process complexity, and cleanness, compared to Al2O3 and a-Si:H passivation. (d) Nafion is the ideal room temperature passivation, which can be applied onto a small fragment of a degraded module to investigate microscopic mechanisms when studying degradation mechanisms. Edge passivation is needed for advanced characterization tests such as Electron Paramagnetic Resonance (EPR), Electrically Detected Magnetic Resonance (EDMR), Deep Level Transient Spectroscopy (DLTS), local cell current-voltage (J-V), and Suns-Voc. In such cases, the laser-damaged minicell edges will obscure the true degradation mechanisms, and Nafion can effectively passivate them without causing further degradation through elevated-temperature processes. In this contribution, we show the passivation results of Nafion on bare nCz and compare it with a Al2O3 witness. We highlight the importance of edge pre-treatment before Nafion to achieve good passivation. We show that Nafion can reach decent passivation without undergoing high-temperature processes. We also explore the temperature dependency of Nafion through photoluminescence (PL) study and demonstrate the application of Nafion under cryogenic temperature (~6 K) through EPR. Our results reveal that Nafion can reduce surface and edge Si dangling bonds at low temperatures. Thus, it can be used as an effective room temperature passivation technique for advanced characterization methods.

c-Si↗

Magnetocaloric effect in Mn-rich Heusler-derived alloys for room temperature-based applications

Magnetic refrigeration-based technologies rely on the magnetocaloric properties of materials and are crucial for improving energy efficiency and for supporting clean environments. However, materials possessing significant magnetocaloric properties that can be used for room temperature-based applications are still lacking. Heusler alloys (such as Mn–Ni–Ga) show giant magnetocaloric effects, which can be further improved by tuning their composition. Herein, we optimized the ratio of Ni to Ga to achieve an alloy with unique magnetocaloric properties. Here, the alloy demonstrated a substantial magnetocaloric effect, attributed to its narrow temperature range for structural and magnetic phase transitions (near room temperature with minimal hysteresis). Structural phase changes were also observed through high-resolution transmission electron microscopy. Optimum entropy changes, calculated from isothermal magnetization curves (4 Tesla magnetic field), were found to be 24.50 J kg −1 K −1 , which is higher than that of state-of-the-art alloys. Experimental demonstration of the magnetocaloric effect (refrigeration cycle) was also carried out using a thermal imaging camera. Furthermore, first-principles calculations were conducted to validate the experimental findings, specifically focusing on the compositional effects on the structural transitions and magnetic properties of the investigated MNG alloys.

36 MATERIALS SCIENCE↗

Atomic-Scale STEM Analysis Shows Structural Changes of Au–Pd Nanoparticles in Various Gaseous Environments

We report dynamical restructuring effects in free-standing Au 0.75 Pd 0.25 nanoparticles occurring in gaseous environments at elevated temperatures. The freshly prepared sample was found to have a core–shell structure with a Pd-rich phase on the surface. The evolution of sample composition and morphology under exposure to 1 bar of pure gases, namely O 2 , H 2 , air, CO, and CO 2 , at different temperatures was studied using in situ scanning transmission electron microscopy (STEM) and energy-dispersive X-ray spectroscopy (EDS). We observed sharper facets on the surface of the particles under O 2 or air at 400 °C. Small islands of Pd were present on the surface, although some Pd was redistributed inside the bulk when the temperature was increased under O 2 . Subtle changes in surface roughness were noted when O 2 was substituted with H 2 at 400 °C, an observation correlated to density functional theory (DFT) calculations. The particles lost clean surface facets when CO was introduced at room temperature and at 200 °C. No substantial changes could be observed after exposure to CO 2 at 250 °C. The adsorption of CO molecules on the surface modifies the surface of the particles and decreases the facet prevalence. Furthermore, these in situ observations show how gases can induce subtle modification of the surface of nanocatalysts, potentially impacting their chemical properties.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An XPS study of the stability of Fomblin Z25 on the native oxide of aluminum

Thin films of Fomblin Z25, a perfluoropolyalkylether lubricant, were vapor deposited onto clean, oxidized aluminum and sapphire surfaces, and their behavior at different temperatures was studied using x ray photoelectron spectroscopy (XPS) and thermal desorption spectroscopy (TDS). It was found that the interfacial fluid molecules decompose on the native oxide at room temperature, and continue to decompose at elevated temperatures, as previous studies had shown to occur on clean metal. TDS indicated that different degradation mechanisms were operative for clean and oxidized aluminum. On sapphire substrates, no reaction was observed at room temperature. Our conclusion is that the native oxide of aluminum is neither passive nor protective towards Fomblin Z25. At high temperatures (150 C) degradation of the polymer on sapphire produced a debris layer at the interface with a chemical composition similar to the one formed on aluminum oxide. Rubbing a Fomblin film on a single crystal sapphire also induced the decomposition of the lubricant in contact with the interface and the formulation of a debris layer.

Herrera-Fierro, Pilar↗

X-ray photoelectron spectroscopy study of the stability of Fomblin Z25 on the native oxide of aluminum

Thin films of Fomblin Z25, a perfluoropolyalkylether lubricant, were vapor deposited onto clean, oxidized aluminum, and onto sapphire surfaces, and their behavior at different temperatures was studied using X-ray photoelectron spectroscopy and temperature desorption spectroscopy (TDS). The interfacial fluid molecules decompose on the native oxide at room temperature, and continue to decompose at elevated temperatures, as previous studies had shown to occur on the clean metal. TDS indicated that different degradation mechanisms were operative for clean and oxidized aluminum. On sapphire substrates, no reaction was observed at room temperature. The native oxide of aluminum is neither passive nor protective towards Fomblin Z25. At higher temperatures (150 C), degradation of the polymer on sapphire produced a debris layer at the interface with a chemical composition similar to the one formed on aluminum oxide. Rubbing a Fomblin film on a single crystal sapphire also induced the decomposition of the lubricant in contact with the interface and the formation of a debris layer.

Herrera-Fierro, Pilar↗

Energy migration and scintillation kinetics in compositionally complex (Gd 1/4 Y 1/4 Tb 1/4 Lu 1/4 ) 3 Al 5 O 12 :Ce single crystal scintillator

It is well-established that compositional tuning through binary admixture can improve scintillation performance in several materials systems, including Ce-activated garnets. Although recent work on ternary or quaternary cation admixture shows promise, the impact of this increased compositional complexity on thermal stability and carrier-defect dynamics has not been addressed. Here, we investigate a compositionally complex garnet, (Gd 1/4 Y 1/4 Tb 1/4 Lu 1/4 ) 3 Al 5 O 12 :Ce (GYTLAG), grown by the Czochralski method using temperature-dependent photoluminescence (PL), PL decay, and thermoluminescence (TL). PL and PL decay measurements support a thermally activated Tb 3+ -Ce 3+ energy transfer, where Tb 3+ emission dominates below 60 K, but Ce 3+ emission increases from 20-300 K. Thermal quenching of Ce 3+ emission occurs around T 50 = 508 K, with an activation energy of 0.6 eV. TL and wavelength-resolved TL spectra from 20–500 K show that GYTLAG contains similar trap groups to LuAG but with a broader distribution of glow peaks below room temperature, possibly caused by quaternary cation mixing. A combination of dose dependence, partial cleaning and initial rise, and glow curve fitting to a first order continuous Gaussian distribution model are used to understand the contribution of electronic point defects to scintillation decay and afterglow at room temperature. Furthermore, these results inform how increased compositional complexity influences recombination dynamics in garnet scintillators.

Compositionally complex↗

Detecting Airborne Mercury by Use of Gold Nanowires

Like the palladium chloride (PdCl2) films described in the immediately preceding article, gold nanowire sensors have been found to be useful for detecting airborne elemental mercury at concentrations on the order of parts per billion (ppb). Also like the PdCl2 films, gold nanowire sensors can be regenerated under conditions much milder than those necessary for regeneration of gold films that have been used as airborne-Hg sensors. The interest in nanowire sensors in general is prompted by the expectation that nanowires of a given material covering a given surface may exhibit greater sensitivity than does a film of the same material because nanowires have a greater surface area. In preparation for experiments to demonstrate this sensor concept, sensors were fabricated by depositing gold nanowires, variously, on microhotplate or microarray sensor substrates. In the experiments, the electrical resistances were measured while the sensors were exposed to air at a temperature of 25 C and relative humidity of about 30 percent containing mercury at various concentrations from 2 to 70 ppb (see figure). The results of this and other experiments have been interpreted as signifying that sensors of this type can detect mercury at ppb concentrations in room-temperature air and can be regenerated by exposure to clean flowing air at temperatures <40 C.

Ryan, Margaret↗

Delta-Doping at Wafer Level for High Throughput, High Yield Fabrication of Silicon Imaging Arrays

Systems and methods for producing high quantum efficiency silicon devices. A silicon MBE has a preparation chamber that provides for cleaning silicon surfaces using an oxygen plasma to remove impurities and a gaseous (dry) NH3 + NF3 room temperature oxide removal process that leaves the silicon surface hydrogen terminated. Silicon wafers up to 8 inches in diameter have devices that can be fabricated using the cleaning procedures and MBE processing, including delta doping.

Hoenk, Michael E.↗

Development of megasonic cleaning for silicon wafers

A cleaning and drying system for processing at least 2500 three in. diameter wafers per hour was developed with a reduction in process cost. The system consists of an ammonia hydrogen peroxide bath in which both surfaces of 3/32 in. spaced, ion implanted wafers are cleaned in quartz carriers moved on a belt past two pairs of megasonic transducers. The wafers are dried in the novel room temperature, high velocity air dryer in the same carriers used for annealing. A new laser scanner was used effectively to monitor the cleaning ability on a sampling basis.

Mayer, A.↗

Bosch Carbon Catalyst Regeneration in Water I: Bosch Carbon Removal from Reacted Beads Utilizing Mechanical Agitation

The ability to recover oxygen from metabolic carbon dioxide is crucial for crewed long duration missions in which the atmosphere must be recycled. Two physiochemical methods are primarily employed for this purpose: the Bosch process and the Sabatier reaction. This paper focuses on the Bosch process. It utilizes hydrogen in the presence of a catalyst to form water and solid carbon out of metabolic carbon dioxide. The solid carbon product deposits onto the catalyst and eventually causes reactor over pressurization issues. Multiple methods are currently being investigated to regenerate the catalyst’s surface and break up the pressure causing carbon clogs. This paper explores whether water and mechanical abrasion would work to remove Bosch carbon by testing multiple washing conditions. The different washing conditions involved agitation intensity, heating, duration, and volume of water. It was found that it is possible to break up the clumps of carbon formed in the reactor through agitation with room temperature water in one hour and shows promise for completely cleaning the carbon off the beads’ surface.

Agitation↗