Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Chain rigidity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

256 records · Page 15

A New Computational Method for Membrane Compressibility: Bilayer Mechanical Thickness Revisited

Because lipid bilayers can bend and stretch in ways similar to thin elastic sheets, physical models of bilayer deformation have utilized mechanical constants such as the moduli for bending rigidity (κ C ) and area compressibility (K A ). However, the use of these models to quantify the energetics of membrane deformation associated with protein-membrane interactions, and the membrane response to stress is often hampered by the shortage of experimental data suitable for the estimation of the mechanical constants of various lipid mixtures. Although computational tools such as molecular dynamics simulations can provide alternative means to estimate K A values, current approaches suffer significant technical limitations. Here, in this study, we present a novel, to our knowledge, computational framework that allows for a direct estimation of K A values for individual bilayer leaflets. The theory is based on the concept of elasticity and derives K A from real-space analysis of local thickness fluctuations sampled in molecular dynamics simulations. We explore and validate the model on a large set of single and multicomponent bilayers of different lipid compositions and sizes, simulated at different temperatures. The calculated bilayer compressibility moduli agree with values estimated previously from experiments and those obtained from a standard computational method based on a series of constrained tension simulations. We further validate our framework in a comparison with an existing polymer brush model and confirm the polymer brush model’s predicted linear relationship with proportionality coefficient of 24, using elastic parameters calculated from the simulation trajectories. The robustness of the results that emerge from the method allows us to revisit the origins of the bilayer mechanical (compressible) thickness and in particular its dependence on acyl-chain unsaturation and the presence of cholesterol.

59 BASIC BIOLOGICAL SCIENCES↗

Enhancing Biopolyester Backbone Rigidity with an Asymmetric Furanic Monomer

Biobased furanic polyesters can exhibit performance advantages over petroleum-derived polyesters, primarily due to their rigid furan-containing backbones. Herein, we develop two strategies to polymerize methyl 5-hydroxymethyl furanoate to poly(5-hydroxymethyl furanoate) (PHMF), a furan-based polyester with even greater backbone rigidity than poly(ethylene furanoate). Thermal, spectroscopic, and computational investigations of PHMF alongside analogous furan-based and phenyl-based polyesters suggest that the high furan content of PHMF leads to its high glass transition temperature, slow crystallization kinetics, and low amorphous mobility. Molecular dynamics simulations suggest that while the backbone of PHMF is exceptionally rigid, its amorphous phase is denser than its phenyl analog due to noncovalent interchain interactions. Together, these results highlight how asymmetric furan-based monomers can modulate key properties in biobased polyesters.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Deliverable for FαST project: Ln Resin based PLE

This memo describes the fabrication of a polymer ligand extractant based on Eichrom's LN-1 resin. This work has been in support of the Fast Alpha Spectrometry Tool (FαST) project. The first part of LANL's role in this project is to evaluate new extractants for use in polymer ligand extractants (PLEs). The first new extractant evaluated is Di(2-ethyl hexyl) phosphoric acid (HDEHP), which is an effective metal extractant. It has very efficient chelating properties for a wide variety of metal ions. HDEHP is an amphiphillic molecule with two long hydrocarbon chains and a polar end with a phosphoryl oxygen (P=O) and an acidic -OH group as shown in Figure 1. HDEHP has shown effectiveness in extracting lanthanides, selective actinides, and other trivalent elements. Several authors have reported that lanthanides and elements with +3 oxidation state have similar extraction behavior in nitric acid. The distribution ratio for lanthanides rapidly decreases at lower nitric concentration then start to increase at higher concentration as shown in. The trivalent americium, curium, and yttrium exhibit similar trend as trivalent lanthanides. This extraction trend can be also observed from hydrogen chloride solution. This work describes the use of this ligand in a PLE to extract plutonium from solution. Polymer ligand films were prepared by dissolving HDEHP ligands and polystyrene beads in THF. The solution was directly deposited onto a 40 mm diameter stainless steel substrate using an automated pipette. HDEHP based PLEs with direct stippling method are shown in Figure 2. The solution was air dried at room temperature overnight to ensure complete evaporation of THF. The plutonium tracer solution was prepared in 0.01, 0.1, 1, and 8M nitric solutions to study the effect of nitric concentration in plutonium extraction. 0.1667 Bq 239 Pu tracer solution was directly stippled on each PLE and was allowed to equilibrate for 3 hours before removing the solution. The plutonium activity of each sample was measured by direct alpha counting to quantify the plutonium recovery by HDEHP PLE. The alpha spectra from alpha spectroscopy are shown in Figure 3. 1:5, 1:10, and 1:20 PLEs had sharp peak with low tailing. 1:2 had an extremely long tail, which is a possible indication that a large amount of ligands caused the film to not form a smooth surface. Also, it can be noted that 1:2 ratio PLE surface was not as rigid as the other ratio PLEs and it was prone to scratching during sample handing. The resolution of alpha spectra was quantified by measuring Full Width at Half of the Maximum (FWHM) using Bortels equation. The tailing component of the peak was also measured along with FWHM. The peak resolutions and tailing measurements for 0.1M nitric solution samples are given in Table 1. The best resolution was achieved with 1:5 PLE and worst was given by 1:2 PLE. The plutonium recovery by HDEHP PLE was dependent on both nitric concentration and ligand to polymer ratio. 1:2 PLE consistently had the highest recovery followed by 1:5 as shown in Figure 4. It should be noted that 1:2 ratio PLEs consistently had long tailing and the ROI of the spectrum had to be increased to encompass total counts from the tracer. 1:10 and 1:20 PLEs had close to zero percent recovery in all nitric concentration except for 0.01M. The highest plutonium recovery was observed for 0.1M nitric acid. 1:5 PLE gave the best combination of alpha spectroscopy resolution and plutonium recovery. Radiography image of samples were generated to study the plutonium distribution on the PLE surface. Samples were placed on an imaging plate (Fujifilm BAS-TR 2025) for 24 hours and the plate was scanned using GE Typhoon FLA 7000 system. The radiography image in Figure 5 shows uneven distribution with hot spots along the edge and in the center of the samples. These hot spots may be the result of highly localized concentration of ligands or surface defects that were observed in SEM. This unevenness in distribution may cause inaccurate activity measurement by alpha spectroscopy due to a bias in the energy calibration. PLEs based on HDEHP have been evaluated. The concentration of ligand in polystyrene is critical in the performance of the PLE; both for extraction efficiency as well as for alpha spectrometry results. The optimal PLE using this ligand has a concentration of 1:5 ligand to polystyrene. Under laboratory conditions, this configuration can produce similar results to those obtained for DIPEX based PLEs from previous studies. The concentration is very important to the results obtained for this ligand. This PLE is a good candidate for use in later field studies. Our next report will detail the evaluation of PLEs utilizing crown ether ligands.

36 MATERIALS SCIENCE↗

A discretized representation for Monte Carlo simulation of deformed semiflexible chains

In this study, we present a novel orientation discretization approach based on the rhombic triacontahedron for Monte Carlo simulations of semiflexible polymer chains, aiming at enhancing structural analysis through rheo-small-angle scattering (rheo-SAS). Our approach provides a more accurate representation of the geometric features of semiflexible chains under deformation, surpassing the capabilities of traditional lattice structures. Validation against the Kratky–Porod chain system demonstrated superior consistency, underscoring its potential to significantly improve the precision of uncovering geometric details from rheo-SAS data. Further, this approach opens new avenues for investigating the conformations of semiflexible polymers and mechanically induced phase transitions in more complex polymer structures, offering deeper insights into their behavior under various conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗