Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CT Scans”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

SU-G-JeP2-14: MRI-Based HDR Prostate Brachytherapy: A Phantom Study for Interstitial Catheter Reconstruction with 0.35T MRI Images

Purpose: To evaluate the accuracy of interstitial catheter reconstruction with 0.35T MRI images for MRI-based HDR prostate brachytherapy. Methods: Recently, a real-time MRI-guided radiotherapy system combining a 0.35T MRI system and three cobalt 60 heads (MRIdian System, ViewRay, Cleveland, OH, USA) was installed in our department. A TrueFISP sequence for MRI acquisition at lower field on Viewray was chosen due to its fast speed and high signal-to-noise efficiency. Interstitial FlexiGuide needles were implanted into a tissue equivalent ultrasound prostate phantom (CIRS, Norfolk, Virginia, USA). After an initial 15s pilot MRI to confirm the location of the phantom, planning MRI was acquired with a 172s TrueFISP sequence. The pulse sequence parameters included: flip angle = 60 degree, echo time (TE) =1.45 ms, repetition time (TR) = 3.37 ms, slice thickness = 1.5 mm, field of view (FOV) =500 × 450mm. For a reference image, a CT scan was followed. The CT and MR scans were then fused with the MIM Maestro (MIM software Inc., Cleveland, OH, USA) and sent to the Oncentra Brachy planning system (Elekta, Veenendaal, Netherlands). Automatic catheter reconstruction using CT and MR image intensities followed by manual reconstruction was used to digitize catheters. The accuracy of catheter reconstruction was evaluated from the catheter tip location. Results: The average difference between the catheter tip locations reconstructed from the CT and MR in the transverse, anteroposterior, and craniocaudal directions was −0.1 ± 0.1 mm (left), 0.2 ± 0.2 mm (anterior), and −2.3 ± 0.5 mm (cranio). The average distance in 3D was 2.3 mm ± 0.5 mm. Conclusion: This feasibility study proved that interstitial catheters can be reconstructed with 0.35T MRI images. For more accurate catheter reconstruction which can affect final dose distribution, a systematic shift should be applied to the MR based catheter reconstruction in HDR prostate brachytherapy.

60 APPLIED LIFE SCIENCES↗

SU-E-J-68: Adaptive Radiotherapy of Head and Neck Cancer: Re-Planning Based On Prior Dose

Purpose: Adaptive Radiotherapy (ART) with frequent CT imaging has been used to improve dosimetric accuracy by accounting for anatomical variations, such as primary tumor shrinkage and/or body weight loss, in Head and Neck (H&N) patients. In most ART strategies, the difference between the planned and the delivered dose is estimated by generating new plans on repeated CT scans using dose-volume constraints used with the initial planning CT without considering already delivered dose. The aim of this study was to assess the dosimetric gains achieved by re-planning based on prior dose by comparing them to re-planning not based-on prior dose for H&N patients. Methods: Ten locally-advanced H&N cancer patients were selected for this study. For each patient, six weekly CT imaging were acquired during the course of radiotherapy. PTVs, parotids, cord, brainstem, and esophagus were contoured on both planning and six weekly CT images. ART with weekly re-plans were done by two strategies: 1) Generating a new optimized IMRT plan without including prior dose from previous fractions (NoPriorDose) and 2) Generating a new optimized IMRT plan based on the prior dose given from previous fractions (PriorDose). Deformable image registration was used to accumulate the dose distributions between planning and six weekly CT scans. The differences in accumulated doses for both strategies were evaluated using the DVH constraints for all structures. Results: On average, the differences in accumulated doses for PTV1, PTV2 and PTV3 for NoPriorDose and PriorDose strategies were <2%. The differences in Dmean to the cord and brainstem were within 3%. The esophagus Dmean was reduced by 2% using PriorDose. PriorDose strategy, however, reduced the left parotid D50 and Dmean by 15% and 14% respectively. Conclusion: This study demonstrated significant parotid sparing, potentially reducing xerostomia, by using ART with IMRT optimization based on prior dose for weekly re-planning of H&N cancer patients.

60 APPLIED LIFE SCIENCES↗

SU-E-J-220: Assessment of MRI Geometric Distortion in Head and Neck Cancer Patients Scanned in Immobilized Radiation Treatment Position

Purpose: Uncertainties about geometric distortion have somewhat hindered MRI simulation in radiation therapy. Most of the geometric distortion studies were performed with phantom measurements but another major aspect of MR distortion is patient related. We studied the geometric distortion in patient images by comparing their MRI scans with the corresponding CT, using CT as the non-distorted gold standard. Methods: Ten H&N cancer patients were imaged with MRI as part of a prospective IRB approved study. All patients had their treatment planning CT done on the same day or within one week of the MRI. MR Images were acquired with a T2 SE sequence (1×1×2.5mm voxel size) in the same immobilization position as in the CT scans. MRI to CT rigid registration was then done and geometric distortion comparison was done by measuring the corresponding anatomical landmarks on both the MRI and the CT images by two observers. Several skin to skin (9 landmarks), bone to bone (8 landmarks), and soft tissue (3 landmarks) were measured at specific levels in horizontal and vertical planes of both scans. Results: The mean distortion for all landmark measurements in all scans was 1.8±1.9mm. For each patient 11 measurements were done in the horizontal plane while 9 were done in the vertical plane. The measured geometric distortion were significantly lower in the horizontal axis compared to the vertical axis (1.3±0.16 mm vs 2.2±0.19 mm, respectively, P=0.003*). The magnitude of distortion was lower in the bone to bone landmarks compared to the combined soft tissue and skin to skin landmarks (1.2±0.19 mm vs 2.3±0.17 mm, P=0.0006*). The mean distortion measured by observer one was not significantly different compared toobserver 2 (2.3 vs 2.4 mm, P=0.4). Conclusion: MRI geometric distortions were quantified in H&N patients with mean error of less than 2 mm. JW received a corporate sponsored research grant from Elekta.

60 APPLIED LIFE SCIENCES↗

Tumor Volume Is Better Than Diameter for Predicting the Prognosis of Patients with Early-Stage Non-small Cell Lung Cancer

Background: This study aimed to investigate whether tumor volume (TV) is better than diameter for predicting the prognosis of patients with early-stage non-small cell lung cancer (NSCLC) after complete resection. Methods: This study retrospectively reviewed the clinicopathologic characteristics of 274 patients with early-stage NSCLC who had received pretreatment computed tomography (CT) scans and complete resection. TV was semi-automatically measured from CT scans using an imaging software program. The optimal cutoff of TV was determined by X-tile software. Disease-free survival (DFS) and overall survival (OS) were assessed by the Kaplan–Meier method. The prognostic significance of TV and other variables was assessed by Cox proportional hazards regression analysis. Results: Using 3.046 cm{sup 3} and 8.078 cm{sup 3} as optimal cutoff values of TV, the patients were separated into three groups. A larger TV was significantly associated with poor DFS and OS in the multivariable analysis. Kaplan–Meier curves of DFS and OS showed significant differences on the basis of TV among patients with stage 1a disease, greatest tumor diameter (GTD) of 2 cm or smaller, and GTD of 2–3 cm, respectively. Using two TV cutoff points, three categories of TV were created. In 54 cases (19.7%), patients migrated from the GTD categories of 2 cm or smaller, 2–3 cm, and larger than 3 cm into the TV categories of 3.046 cm{sup 3} or smaller, 3.046–8.078 cm{sup 3}, and larger than 8.078 cm{sup 3}. Conclusion: TV is an independent prognostic factor of DFS and OS for early-stage NSCLC. The findings show that TV is better than GTD for predicting the prognosis of patients with early-stage NSCLC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-J-123: CT-Based Determination of DIBH Variability and Its Dosimetric Impact On Post-Mastectomy Plus Regional Nodal Radiation Therapy

Purpose: Breast cancer radiotherapy delivered using voluntary deep inspiration breath-hold (DIBH) requires reproducible breath holds, particularly when matching supraclavicular fields to tangential fields. We studied the impact of variation in DIBHs on CTV and OAR dose metrics by comparing the dose distribution computed on two DIBH CT scans taken at the time of simulation. Methods: Ten patients receiving 50Gy in 25 fractions to the left chestwall and regional lymph nodes were studied. Two simulation CT scans were taken during separate DIBHs along with a free-breathing (FB) scan. The treatment was planned using one DIBH CT. The dose was recomputed on the other two scans using adaptive planning (Pinnacle 9.10) in which the scans are registered using a cross-correlation algorithm. The chestwall, lymph nodes and OARs were contoured on the scans following the RTOG consensus guidelines. The overall translational and rotational variation between the DIBH scans was used to estimate positional variation between breath-holds. Dose metrics between plans were compared using paired t-tests (p < 0.05) and means and standard deviations were reported. Results: The registration parameters were sub-millimeter and sub-degree. Although DIBH significantly reduced mean heart dose by 2.4Gy compared to FB (p < 0.01), no significant changes in dose were observed for targets or OARs between the two DIBH scans. Nodal coverage as assessed by V90% was 90%±8% and 89%±8% for supraclavicular and 99%±2% and 97%±22% for IM nodes. Though a significant decrease (10.5%±12.4%) in lung volume in the second DIBH CT was observed, the lung V20Gy was unchanged (14±2% and 14±3%) between the two DIBH scans. Conclusion: While the lung volume often varied between DIBHs, the CTV and OAR dose metrics were largely unchanged. This indicates that manual DIBH has the potential to provide consistent dose delivery to the chestwall and regional nodes targets when using matched fields.

60 APPLIED LIFE SCIENCES↗

Is radiography justified for the evaluation of patients presenting with cervical spine trauma?

Conventional radiography has been for decades the standard method of evaluation for cervical spine trauma patients. However, currently available helical multidetector CT scanners allow multiplanar reconstruction of images, leading to increased diagnostic accuracy. The purpose of this study was to determine the relative benefit/risk ratio between cervical spine CT and cervical spine radiography and between cervical spine CT and cervical spine radiography, followed by CT as an adjunct for positive findings. A decision analysis model for the determination of the optimum imaging technique was developed. The sensitivity and specificity of CT and radiography were obtained by dedicated meta-analysis. Lifetime attributable risk of mortal cancer from CT and radiography was calculated using updated organ-specific risk coefficients and organ-absorbed doses. Patient organ doses from radiography were calculated using Monte Carlo techniques, simulated exposures performed on an anthropomorphic phantom, and thermoluminescence dosimetry. A prospective patient study was performed regarding helical CT scans of the cervical spine. Patient doses were calculated based on the dose-length-product values and Monte Carlo-based CT dosimetry software program. Three groups of patient risk for cervical spine fracture were incorporated in the decision model on the basis of hypothetical trauma mechanism and clinical findings. Radiation effects were assessed separately for males and females for four age groups (20, 40, 60, and 80 yr old). Effective dose from radiography amounts to 0.050 mSv and from a typical CT scan to 3.8 mSv. The use of CT in a hypothetical cohort of 10{sup 6} patients prevents approximately 130 incidents of paralysis in the low risk group (a priori fracture probability of 0.5%), 500 in the moderate risk group (a priori fracture probability of 2%), and 5100 in the high risk group (a priori fracture probability of 20%). The expense of this CT-based prevention is 15-32 additional radiogenic lethal cancer incidents. According to the decision model calculations, the use of CT is more favorable over the use of radiography alone or radiography with CT by a factor of 13, for low risk 20 yr old patients, to a factor of 23, for high risk patients younger than 80 yr old. The radiography/CT imaging strategy slightly outperforms plain radiography for high and moderate risk patients. Regardless of the patient age, sex, and fracture risk, the higher diagnostic accuracy obtained by the CT examination counterbalances the increase in dose compared to plain radiography or radiography followed by CT only for positive radiographs and renders CT utilization justified and the radiographic screening redundant.

61 RADIATION PROTECTION AND DOSIMETRY↗

Identifying the Accuracy of Surface Roughness for Metal Additive Manufacturing Parts Captured with Computed Tomography Scanning

Conventional surface roughness measurement techniques require direct access to internal surfaces, often necessitating destructive sectioning of test articles. Computed tomography (CT) offers a non-destructive alternative for internal surface characterization, but its application in metrology remains unstandardized and sensitive to machine resolution and operator technique. This study investigates the feasibility of using CT scanning to quantify areal surface roughness in metal AM heat exchanger tubes with three distinct internal geometries: ribbed, discrete W, and featureless. CT-derived surface parameters were extracted using custom Python scripts and compared to measurements obtained from a focus variation microscope calibrated against a known standard. Results show that CT-based roughness measurements closely matched microscope values for the discrete W specimen, deviations between CT and microscope measurements were minimal—less than 1 µm—indicating reliable reconstruction. In contrast, the ribbed and featureless specimens, with lower roughness values showed greater discrepancies. The findings suggest that CT scanning can be a viable non-destructive metrology tool for AM parts with surface roughness above approximately 8 µm. For smoother surfaces, current CT capabilities may not provide sufficient accuracy, highlighting the need for resolution-aware workflows and further standardization in CT-based surface metrology.

36 MATERIALS SCIENCE↗

SU-C-9A-06: The Impact of CT Image Used for Attenuation Correction in 4D-PET

Purpose: To evaluate the appropriateness of using 3D non-gated CT image for attenuation correction (AC) in a 4D-PET (gated PET) imaging protocol used in radiotherapy treatment planning simulation. Methods: The 4D-PET imaging protocol in a Siemens PET/CT simulator (Biograph mCT, Siemens Medical Solutions, Hoffman Estates, IL) was evaluated. CIRS Dynamic Thorax Phantom (CIRS Inc., Norfolk, VA) with a moving glass sphere (8 mL) in the middle of its thorax portion was used in the experiments. The glass was filled with {sup 18}F-FDG and was in a longitudinal motion derived from a real patient breathing pattern. Varian RPM system (Varian Medical Systems, Palo Alto, CA) was used for respiratory gating. Both phase-gating and amplitude-gating methods were tested. The clinical imaging protocol was modified to use three different CT images for AC in 4D-PET reconstruction: first is to use a single-phase CT image to mimic actual clinical protocol (single-CT-PET); second is to use the average intensity projection CT (AveIP-CT) derived from 4D-CT scanning (AveIP-CT-PET); third is to use 4D-CT image to do the phase-matched AC (phase-matching- PET). Maximum SUV (SUVmax) and volume of the moving target (glass sphere) with threshold of 40% SUVmax were calculated for comparison between 4D-PET images derived with different AC methods. Results: The SUVmax varied 7.3%±6.9% over the breathing cycle in single-CT-PET, compared to 2.5%±2.8% in AveIP-CT-PET and 1.3%±1.2% in phasematching PET. The SUVmax in single-CT-PET differed by up to 15% from those in phase-matching-PET. The target volumes measured from single- CT-PET images also presented variations up to 10% among different phases of 4D PET in both phase-gating and amplitude-gating experiments. Conclusion: Attenuation correction using non-gated CT in 4D-PET imaging is not optimal process for quantitative analysis. Clinical 4D-PET imaging protocols should consider phase-matched 4D-CT image if available to achieve better accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Upright cone beam CT imaging using the onboard imager

Purpose: Many patients could benefit from being treated in an upright position. The objectives of this study were to determine whether cone beam computed tomography (CBCT) could be used to acquire upright images for treatment planning and to demonstrate whether reconstruction of upright images maintained accurate geometry and Hounsfield units (HUs). Methods: A TrueBeam linac was programmed in developer mode to take upright CBCT images. The gantry head was positioned at 0°, and the couch was rotated to 270°. The x-ray source and detector arms were extended to their lateral positions. The x-ray source and gantry remained stationary as fluoroscopic projections were taken and the couch was rotated from 270° to 90°. The x-ray tube current was normalized to deposit the same dose (measured using a calibrated Farmer ion chamber) as that received during a clinical helical CT scan to the center of a cylindrical, polyethylene phantom. To extend the field of view, two couch rotation scans were taken with the detector offset 15 cm superiorly and then 15 cm inferiorly. The images from these two scans were stitched together before reconstruction. Upright reconstructions were compared to reconstructions from simulation CT scans of the same phantoms. Two methods were investigated for correcting the HUs, including direct calibration and mapping the values from a simulation CT. Results: Overall geometry, spatial linearity, and high contrast resolution were maintained in upright reconstructions. Some artifacts were created and HU accuracy was compromised; however, these limitations could be removed by mapping the HUs from a simulation CT to the upright reconstruction for treatment planning. Conclusions: The feasibility of using the TrueBeam linac to take upright CBCT images was demonstrated. This technique is straightforward to implement and could be of enormous benefit to patients with thoracic tumors or those who find a supine position difficult to endure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intercostal Artery Supplying Hepatocellular Carcinoma: Demonstration of a Tumor Feeder by C-arm CT and Multidetector Row CT

This study was designed to describe tumor feeders from the intercostal artery supplying hepatocellular carcinoma (HCC) on C-arm CT and multidetector row CT. From March 2008 to May 2009, C-arm CT of the intercostal artery was prospectively performed in 24 HCC patients. Two interventional radiologists, who performed C-arm CT, evaluated tumor feeders on C-arm CT and multidetector row CT scans by consensus. In total, 35 intercostal arteries were examined by C-arm CT. All tumor feeders except one showed a sharp upward turn at or near the costochondral junction. On axial C-arm CT images, all tumor feeders were observed as an enhancing dot in the upper intercostal space along the diaphragm. On multidetector CT scans, 17 tumor feeders were observed and 18 were not. Tumor feeders from the intercostal artery are observed as an enhancing dot along the diaphragm on C-arm CT and can be seen on multidetector row CT in approximately half of patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dunham Pad A 4H Well

Medical CT scans, raw and processed core logging data (including XRF) and core images of the Dunham Pad A 4H well, obtained by Triana Energy, as supplemental information to the NETL Technical Report Series Crandall, D.; Brown, S.; Moore, J.; Martin, K.; Mackey, P.; Carr, T. CT Scanning and Geophysical Measurements of the Marcellus Formation from the Dunham Pad A 4H Well NETL-TRS-X-2018; NETL Technical Report Series; U.S. Department of Energy, National Energy Technology Laboratory: Morgantown, WV, 2018; p 48.

Core Logs↗

CT and Scanning Data of the KGS Wellington 1-32 CarbonSAFE Core

Data described in the NETL Technical Report Series "Computed Tomography Scanning and Geophysical Measurements of the Wellington 1-32 Core", including processed and raw CT and measurements from NETL's multi-sensor core logger. Paronish, T.; Schmitt, R.; Mitchell, N; Brown, S; Crandall, D.; Moore, J.; Hasiuk, F.; Potter, N.; Holubnyak, Y.E. Computed Tomography Scanning and Geophysical Measurements of the Wellington 1-32 Core; DOE.NETL-2021.2882; NETL Technical Report Series; U.S. Department of Energy, National Energy Technology Laboratory: Morgantown, WV, 2022; p 108. DOI: https://doi.org/10.2172/1894355 https://edx.netl.doe.gov/dataset/computed-tomography-scanning-and-geophysical-measurements-of-the-wellington-1-32-core

CarbonSafe↗

SU-E-T-383: Evaluation of Deep Inspiration Breath-Hold Technique for Post-Mastectomy Proton Pencil Beam Scanning Therapy

Purpose: Deep inspiration breath-hold techniques (DIBH) have been shown to carry significant dosimetric advantages in conventional radiotherapy of left-sided breast cancer. The purpose of this study is to evaluate the use of DIBH techniques for post-mastectomy radiation therapy (PMRT) using proton pencil beam scanning (PBS). Method: Ten PMRT patients, with or without breast implant, underwent two helical CT scans: one with free breathing and the other with deep inspiration breath-hold. A prescription of 50.4 Gy(RBE) to the whole chest wall and lymphatics (axillary, supraclavicular, and intramammary nodes) was considered. PBS plans were generated for each patient’s CT scan using Astroid, an in-house treatment planning system, with the institution conventional clinical PMRT parameters; that is, using a single en-face field with a spot size varying from 8 mm to 14 mm as a function of energy. Similar optimization parameters were used in both plans in order to ensure appropriate comparison. Results: Regardless of the technique (free breathing or DIBH), the generated plans were well within clinical acceptability. DIBH allowed for higher target coverage with better sparing of the cardiac structures. The lung doses were also slightly improved. While the use of DIBH techniques might be of interest, it is technically challenging as it would require a fast PBS delivery, as well as the synchronization of the beam delivery with a gating system, both of which are not currently available at the institution. Conclusion: DIBH techniques display some dosimetric advantages over free breathing treatment for PBS PMRT patients, which warrants further investigation. Plans will also be generated with smaller spot sizes (2.5 mm to 5.5 mm and 5 mm to 9 mm), corresponding to new generation machines, in order to further quantify the dosimetric advantages of DIBH as a function of spot size.

60 APPLIED LIFE SCIENCES↗

Impacts of Superalloys on the Surface Quality of Additively Manufactured Channels

Abstract Gas turbines feature many components that require superalloys capable of handling extreme thermal environments. Increasing the selection of materials available for these components is important to their use in these extremely high-temperature environments. This study investigated two recently developed materials intended to be used for additive manufacturing (AM), with one superalloy based on cobalt and the other on nickel. Sets of four test coupons were built using the materials, in addition to the commonly used Inconel-718, on multiple laser powder bed fusion machines. Several build conditions were varied between coupon sets, including coupon orientation, contour settings, and upskin and downskin treatment. Each set of test coupons featured four unique cooling designs to explore how different cooling technologies would be impacted by the variations in build conditions. After being built, coupons were computed tomography (CT) scanned to determine accuracy to design intent and quantify the surface roughness. The CT scans indicated that horizontally built test coupons had a significantly higher deviation from design intent and higher surface roughness than those built vertically. Results also indicated that the cobalt-based alloy consistently had a smoother surface quality with lower surface roughness compared to the nickel-based alloy. After geometric characterization, the cooling performance of the test coupons was measured experimentally. Pressure losses were found to correlate with increases in surface roughness; however, in some cases, the convective heat transfer did not increase proportionally to the pressure loss as a result of surface features significantly blocking the flow without proportionally increasing convective heat transfer.

Engineering↗

Robust Proton Pencil Beam Scanning Treatment Planning for Rectal Cancer Radiation Therapy

Purpose: To investigate, in a treatment plan design and robustness study, whether proton pencil beam scanning (PBS) has the potential to offer advantages, relative to interfraction uncertainties, over photon volumetric modulated arc therapy (VMAT) in a locally advanced rectal cancer patient population. Methods and Materials: Ten patients received a planning CT scan, followed by an average of 4 weekly offline CT verification CT scans, which were rigidly co-registered to the planning CT. Clinical PBS plans were generated on the planning CT, using a single-field uniform-dose technique with single-posterior and parallel-opposed (LAT) fields geometries. The VMAT plans were generated on the planning CT using 2 6-MV, 220° coplanar arcs. Clinical plans were forward-calculated on verification CTs to assess robustness relative to anatomic changes. Setup errors were assessed by forward-calculating clinical plans with a ±5-mm (left–right, anterior–posterior, superior–inferior) isocenter shift on the planning CT. Differences in clinical target volume and organ at risk dose–volume histogram (DHV) indicators between plans were tested for significance using an appropriate Wilcoxon test (P<.05). Results: Dosimetrically, PBS plans were statistically different from VMAT plans, showing greater organ at risk sparing. However, the bladder was statistically identical among LAT and VMAT plans. The clinical target volume coverage was statistically identical among all plans. The robustness test found that all DVH indicators for PBS and VMAT plans were robust, except the LAT's genitalia (V5, V35). The verification CT plans showed that all DVH indicators were robust. Conclusions: Pencil beam scanning plans were found to be as robust as VMAT plans relative to interfractional changes during treatment when posterior beam angles and appropriate range margins are used. Pencil beam scanning dosimetric gains in the bowel (V15, V20) over VMAT suggest that using PBS to treat rectal cancer may reduce radiation treatment–related toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Utility of Megavoltage Fan-Beam CT for Treatment Planning in a Head-And-Neck Cancer Patient with Extensive Dental Fillings Undergoing Helical Tomotherapy

The purpose of this study was to demonstrate the potential utility of megavoltage fan-beam computed tomography (MV-FBCT) for treatment planning in a patient undergoing helical tomotherapy for nasopharyngeal carcinoma in the presence of extensive dental artifact. A 28-year-old female with locally advanced nasopharyngeal carcinoma presented for radiation therapy. Due to the extensiveness of the dental artifact present in the oral cavity kV-CT scan acquired at simulation, which made treatment planning impossible on tomotherapy planning system, MV-FBCT imaging was obtained using the HI-ART tomotherapy treatment machine, with the patient in the treatment position, and this information was registered with her original kV-CT scan for the purposes of structure delineation, dose calculation, and treatment planning. To validate the feasibility of the MV-FBCT-generated treatment plan, an electron density CT phantom (model 465, Gammex Inc., Middleton, WI) was scanned using MV-FBCT to obtain CT number to density table. Additionally, both a 'cheese' phantom (which came with the tomotherapy treatment machine) with 2 inserted ion chambers and a generic phantom called Quasar phantom (Modus Medical Devices Inc., London, ON, Canada) with one inserted chamber were used to confirm dosimetric accuracy. The MV-FBCT could be used to clearly visualize anatomy in the region of the dental artifact and provide sufficient soft-tissue contrast to assist in the delineation of normal tissue structures and fat planes. With the elimination of the dental artifact, the MV-FBCT images allowed more accurate dose calculation by the tomotherapy system. It was confirmed that the phantom material density was determined correctly by the tomotherapy MV-FBCT number to density table. The ion chamber measurements agreed with the calculations from the MV-FBCT generated phantom plan within 2%. MV-FBCT may be useful in radiation treatment planning for nasopharyngeal cancer patients in the setting of extensive dental artifacts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Calibration of helical tomotherapy machine using EPR/alanine dosimetry

Purpose: Current codes of practice for clinical reference dosimetry of high-energy photon beams in conventional radiotherapy recommend using a 10x10 cm{sup 2} square field, with the detector at a reference depth of 10 cm in water and 100 cm source to surface distance (SSD) (AAPM TG-51) or 100 cm source-to-axis distance (SAD) (IAEA TRS-398). However, the maximum field size of a helical tomotherapy (HT) machine is 40x5 cm{sup 2} defined at 85 cm SAD. These nonstandard conditions prevent a direct implementation of these protocols. The purpose of this study is twofold: To check the absorbed dose in water and dose rate calibration of a tomotherapy unit as well as the accuracy of the tomotherapy treatment planning system (TPS) calculations for a specific test case. Method: Both topics are based on the use of electron paramagnetic resonance (EPR) using alanine as transfer dosimeter between the Laboratoire National Henri Becquerel (LNHB) {sup 60}Co-{gamma}-ray reference beam and the Institut Curie's HT beam. Irradiations performed in the LNHB reference {sup 60}Co-{gamma}-ray beam allowed setting up the calibration method, which was then implemented and tested at the LNHB 6 MV linac x-ray beam, resulting in a deviation of 1.6% (at a 1% standard uncertainty) relative to the reference value determined with the standard IAEA TRS-398 protocol. Results: HT beam dose rate estimation shows a difference of 2% with the value stated by the manufacturer at a 2% standard uncertainty. A 4% deviation between measured dose and the calculation from the tomotherapy TPS was found. The latter was originated by an inadequate representation of the phantom CT-scan values and, consequently, mass densities within the phantom. This difference has been explained by the mass density values given by the CT-scan and used by the TPS which were not the true ones. Once corrected using Monte Carlo N-Particle simulations to validate the accuracy of this process, the difference between corrected TPS calculations and alanine measured dose values was then found to be around 2% (with 2% standard uncertainty on TPS doses and 1.5% standard uncertainty on EPR measurements). Conclusion: Beam dose rate estimation results were found to be in good agreement with the reference value given by the manufacturer at 2% standard uncertainty. Moreover, the dose determination method was set up with a deviation around 2% (at a 2% standard uncertainty).

61 RADIATION PROTECTION AND DOSIMETRY↗

Interfraction Prostate Rotation Determined from In-Room Computerized Tomography Images

Fiducial markers (FMs) are commonly used as a correction technique for interfraction translations of the prostate. The aim of this investigation was to determine the magnitude of prostate rotations using 2 methods: FM coordinates and the anatomical border of the prostate and rectum. Daily computed tomography (CT) scans (n = 346) of 10 prostate cancer patients with 3 implanted FMs were acquired using the CT on rails. FM coordinates were used to determine rotation in the sagittal, transverse, and coronal planes, and CT contours of the prostate and rectum were used to determine rotation along the sagittal plane. An adaptive technique based on a subset of images (n = 6; planning and first 5 treatment CTs) to reduce systematic rotation errors in the sagittal plane was tested. The standard deviation (SD) of systematic rotation from FM coordinates was 7.6{sup o}, 7.7{sup o}, and 5.0{sup o} in the sagittal, transverse and coronal planes. The corresponding SD of random error was 10.2{sup o}, 15.8{sup o}, and 6.5{sup o}. Errors in the sagittal plane, determined from prostate and rectal contours, were 10.1{sup o} (systematic) and 7.7{sup o} (random). These results did not correlate with rotation computed from FM coordinates (r = -0.017; p = 0.753, n = 337). The systematic error could be reduced by 43% to 5.6{sup o} when the mean prostate position was estimated from 6 CT scans. Prostate rotation is a significant source of error that appears to be more accurately determined using the anatomical border of the prostate and rectum rather than FMs, thus highlighting the utility of CT image guidance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗