Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Compression Analysis of Materials via in situ X-ray Computed Tomography

X-ray computed tomography (X-ray CT) is an analytical technique used in materials science to non– destructively characterize features in a variety of materials like polymers, metals, composites, and explosives. The non-destructive imaging allows for the analysis of features (voids and cracks), which give a fundamental understanding of material characteristics.This is more effective when combinedwith a load cell to expose the material to realworld stimuli to understand material characteristics and morphological behavior in situ. This study focused on using in situ X-ray CT to understand the material characteristics and morphological changes of sugar prills and a lattice under a compressive load. Sugar prills are used as a surrogate to analyze explosives in a safer and less expensiveway. The sugar prills were found to be brittle and shattered when compressed via the CT renderings and the stress/strain information. The lattices are used as both the basis and ground truth comparison for the development of models to predict the morphological and material characteristic changes that occur as a result of loading. The lattice was found to have weak regions due to low polymer interlayer fusion in these regions during the printing process. It was also found that under the initial compression the lattice demonstrated elastic behavior as its cellular structure was intact until the cellular structure started to collapse causing yielding in the lattice. Additionally, the analysis of the sugar prills and lattice demonstrate the information that can be gleaned from in situ X-ray CT experiments that would be lost in traditional pre- and post-mortem X-rayCT analysis.

36 MATERIALS SCIENCE↗

Computed Tomography Scanning and Geophysical Measurements of the Enhanced Geothermal Systems (EGS) Collab SURF Core

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) in Morgantown, West Virginia were used to characterize core from 8 wells from the Enhanced Geothermal Systems (EGS) Collab project located in the Sanford Underground Research Facility’s (SURF) 4850 level. The work in this report falls in Experiment 1 in a three-phase experiment, with the primary purpose to increase understanding of hydraulic fracturing. The primary impetus of this work is a collaboration between U.S. Department of Energy (DOE) and the EGS Collab. The resultant datasets are presented in this report and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/surf-collab-core. All equipment and techniques used were non-destructive, enabling future examinations and analyses to be performed on these cores. None of the equipment used was suitable for direct visualization of the pore space in the core, although fractures and discontinuities were detectable with the methods tested. Low resolution CT imagery with the NETL medical CT scanner was performed on the entire core. Qualitative analysis of the medical CT images, coupled with X-ray fluorescence (XRF), P-wave, and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for more detailed analysis as well as fractured zones. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provides a multi-scale analysis of the core; the resulting macro and micro descriptions are relevant to many subsurface energy related examinations traditionally performed at NETL.

47 OTHER INSTRUMENTATION↗

Computed Tomography Scanning and Geophysical Measurements of the Patterson #5-25 Well in Western Kansas

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) site in Morgantown, West Virginia, were used to characterize core from the Patterson Field site. This core came from a vertical well (Patterson #5-25 well) that was obtained as part of the U.S. Department of Energy (DOE) sponsored Integrated Midcontinental Stacked Carbon Storage Hub. The primary impetus of this work is a collaboration between NETL and the Kansas Geological Survey to characterize core from the Patterson Field site. The 625 ft of whole core from the Atoka Formation to Precambrian Basement was characterized at NETL. As part of this effort, bulk scans of core were obtained. This report, and the associated scans, provide detailed datasets not typically made publicly available for carbon capture utilization and storage analysis. The resultant datasets are presented in this report and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/patterson-5-25-well. All equipment and techniques used were non-destructive, enabling future examinations and analyses to be performed on these cores. None of the equipment used was suitable for direct visualization of the shale pore space, although fractures and discontinuities were detectable with the methods tested. Low resolution CT imagery with the NETL medical CT scanner was performed on the entire core. Qualitative analysis of the medical CT images, coupled with x-ray fluorescence (XRF), P-wave, and magnetic susceptibility measurements from the MSCL are useful in identifying zones of interest for more detailed analysis as well as fractured zones. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provided a multi-scale analysis of this core and provided both a macro and micro description of the core that is relevant for many subsurface energy related examinations that have traditionally been performed at NETL.

58 GEOSCIENCES↗

Post-Marcus Theory and Simulation of Interfacial Charge Transfer Dynamics in Organic Semiconducting Materials (Final Report)

The research program developed, validated and applies predictive computational protocols for calculating charge transfer (CT) rates in complex molecular systems, including molecular dyads and triads in liquid solution and solid-state organic semiconducting (OSC) materials. We have established a transformative computational scheme that goes beyond widely used simplifications, to achieve realistic descriptions of CT processes. The approach properly addresses the contribution of molecular environment at ambient conditions to CT processes. Our approach achieves unique insight on investigated CT processes in relevant experimental efforts. The collaborative team included three principal investigators (PIs), with complimentary expertise in classical molecular dynamics simulations and data science (Cheung), state-of-the-art electronic structure calculations (Dunietz), and cutting-edge theory and simulation techniques for modeling energy, charge and coherence transfer dynamics in molecular systems (Geva).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Computed Tomography Scanning and Geophysical Measurements of the CarbonSAFE Seal Integrity Wells in the Illinois Basin

The U.S. Department of Energy’s (DOE) National Energy Technology Laboratory (NETL) researchers in Morgantown, West Virginia, utilized computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) to evaluate the integrity of three cores (Geophysical Monitor #2 (GM2), Verification Well #1 (VW #1), and Wabash #1 for the Illinois Basin Carbon Storage Assurance Facility Enterprise (CarbonSAFE) efforts. This work was carried out in collaboration with the Illinois State Geological Survey (ISGS) as part of their efforts to analyze cores from two field locations, including the Illinois Basin-Decatur Project (IBDP) and second stage Illinois Industrial Carbon Capture and Storage (IL-ICCS) sites at Decatur, Illinois, and the Wabash CarbonSAFE project at the Wabash Valley Resources Integrated Gasification Combined Cycle plant in Terre Haut, Indiana. The results of this study are presented in several formats and are available online on the Energy Data eXchange (EDX). The rock characterization was conducted using non-destructive techniques, allowing for future analysis of the cores. While the equipment used did not provide direct visualization of shale pore space, it allowed for detection of fractures and discontinuities. Low resolution CT imagery with the NETL medical CT scanner was performed on the entire core. Qualitative analysis of the medical CT images, coupled with x-ray fluorescence (XRF), P-wave, and magnetic susceptibility measurements from the MSCL were utilized to identify areas of interest for further study as well as fractured zones. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provided a multi-scale analysis of this core and provided both a macro and micro description of the core that is relevant for many subsurface energy-related examinations traditionally performed at NETL.

58 GEOSCIENCES↗

Deep Learning Model Segmentations on Computed Tomography 3D Reconstructions of Coffee Beans to Determine Void Ratio (U-Net) and Roast Level (LinkNet)

This project will evaluate the functionality of Object Research Dragonfly software’s user produced deep learning (DL) models on Computed Tomography (CT) scanned coffee beans from green (unroasted) through a dark roast. DL models will be expected to identify voids within the coffee beans, and identify the level of roast of the bean from the CT reconstruction. The scope of this project is intended to meet the Capstone Project requirements of University of California San Diego (UCSD) Structural Engineering master’s degree and offer useful insight on Dragonfly’s DL capability for LANL’s Non-Destructive Evaluation (NDE) CT team. The results of this project will be presented to the E-6 NDE group within LANL. Data acquisition was completed with a North Star Imaging (NSI) X-25 CT Cabinet.

97 MATHEMATICS AND COMPUTING↗

Ruling Out the Onset of Color Transparency up to Q2 = 14.2 GeV2 in Quasielastic 12C(e,e'p) Scattering

Color Transparency (CT) is a prediction of QCD that at high momentum transfer Q2, a system of quarks which would normally interact strongly with nuclear matter could form a small color-neutral object whose compact transverse size would be maintained for some distance, passing through the nucleus undisturbed. A clear signature of CT would be a dramatic rise in nuclear transparency T with increasing Q2. CT emerges as a deviation from Glauber multiple scattering theory, which predicts constant T. While a rise in nuclear transparency would provide an unequivocal validation of QCD factorization theorems, the complex nature of nuclear interactions renders its observation difficult to predict. The E12-06-107 experiment at JLab measured T in quasielastic electron-proton scattering with carbon-12 and liquid hydrogen targets, for Q2 between 8.0 and 14.2 GeV2 , a range over which models of CT predicted that T might differ appreciably from Glauber calculations. Supported in part by US DOE grant DE-FG02-03ER41240.

Matter, John↗

Development of a Control Co-Design Modeling Tool for Marine Hydrokinetic Turbines: Preprint

This report describes the ongoing and planned development of the software package CT-Opt (Current/Tidal Optimization), a control co-design modeling tool for marine hydrokinetic turbines. The commercialization of these turbines has faced significant challenges due to the complex, multidisciplinary nature of their design and the extreme environmental conditions of their operation. This project aims to create a modeling tool that will enable the efficient design of robust, cost-competitive hydrokinetic turbine systems. Rather than using traditional optimization methods, CT-Opt combines multiple models across a range of fidelities to enable coupled optimization of the system design and system controller via a control co-design approach. With this method, the parameters that affect system performance are considered more comprehensively at every stage of the design process. The lowest-fidelity, frequency-domain model called by CT-Opt is RAFT (Response Amplitudes of Floating Turbines), which was originally developed by the National Renewable Energy Laboratory (NREL) to model response amplitudes of floating offshore wind turbines. The highest-fidelity, time-domain model is OpenFAST, which was developed by NREL for land-based and offshore wind turbines. As part of the CT-Opt project, new functionalities will be added to RAFT and OpenFAST to enable the accurate simulation of fixed and floating marine hydrokinetic turbines. In addition to expanding the capabilities of RAFT and OpenFAST, new midfidelity models will be developed. These models will be based on RAFT and OpenFAST and will consist of linearized, state-space models derived from the fully coupled, nonlinear OpenFAST equations and derivative function surrogate models that approximate the nonlinear system behavior. Each model will be coupled with controllers to allow control co-design methods to be applied both within models and across fidelity levels, enabling efficient system optimization.

control co-design↗

Corrosion of rebar in concrete. Part III: Artificial Neural Network analysis of chloride threshold data

Active corrosion of carbon steel in reinforced concrete occurs when the chloride ion concentration exceeds the chloride threshold (CT). CT is affected by many physical and chemical parameters including primary variables (pH, corrosion potential, breakdown potential, and temperature) and secondary variables (cemenet composition, concreete porosity, and water/cement ratio). A Kohonen-self organized map (KSOM) and regression artificial neural network (ANN) coupled methodology was developed to find the missing values of independent variables in the sparse database and for quantitatively evaluating the effects of these variables on CT values that are expressed in %TotalCl/cem (or %FreeCl/cem), and [Cl - ]/[OH - ].

36 MATERIALS SCIENCE↗

X-ray computed tomography-based porosity analysis: Algorithms and application for porous woody biomass

The properties of lignocellulosic biomass, such as bulk physical, thermal, and mechanical properties, as well as the mobility of enzymes or catalysts, are largely affected by porosity, pore structures, and pore size distribution. While X-ray computed tomography (CT) has been introduced to effectively produce 3D volumetric images of material microstructure, a quantitative porosity analysis from the 3D images has never been done. This work introduces a first-of-its-kind X-ray CT-based quantitative porosity analysis method and applies the developed toolkit to characterize the internal porosity distribution of loblolly pine. A sample loblolly pine chip was scanned by a nano-resolution X-ray CT system and digitally reconstructed after a sequence of image processing operations. Here, a comprehensive porosity analysis was then performed to quantify the envelope porosity, the spatial distribution of local porosity, and the directional porosity. Solutions to the various challenges in image processing, porosity calculation, and large data handling are provided.

42 ENGINEERING↗

A wide-field micro-computed tomography detector: micron resolution at half-centimetre scale

Ideal three-dimensional imaging of complex samples made up of micron-scale structures extending over mm to cm, such as biological tissues, requires both wide field of view and high resolution. For existing optics and detectors used for micro-CT (computed tomography) imaging, sub-micron pixel resolution can only be achieved for fields of view of <2 mm. This article presents a unique detector system with a 6 mm field-of-view image circle and 0.5 µm pixel size that can be used in micro-CT units utilizing both synchrotron and commercial X-ray sources. A resolution-test pattern with linear microstructures and whole adult Daphnia magna were imaged at beamline 8.3.2 of the Berkeley Advanced Light Source. Volumes of 10000 × 10000 × 7096 isotropic 0.5 µm voxels were reconstructed over a 5.0 mm × 3.5 mm field of view. Measurements in the projection domain confirmed a 0.90 µm measured spatial resolution that is largely Nyquist-limited. This unprecedented combination of field of view and resolution dramatically reduces the need for sectional scans and computational stitching for large samples, ultimately offering the means to elucidate changes in tissue and cellular morphology in the context of larger, whole, intact model organisms and specimens. This system is also anticipated to benefit micro-CT imaging in materials science, microelectronics, agricultural science and biomedical engineering.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Systems Approach to Estimating the Uncertainty Limits of X-Ray Radiographic Metrology

Micro- and nanomanufacturing capabilities have rapidly expanded over the past decade to include complex three-dimensional (3D) structure fabrication; however, the metrology required to accurately assess these processes via part inspection and characterization has struggled to keep pace. X-ray computed tomography (CT) is considered an ideal candidate for providing the critically needed metrology on the smallest scales, especially internal features, or inaccessible regions. X-ray CT supporting micro- and nanomanufacturing often push against the poorly understood resolution and variation limits inherent to the machines, which can distort or hide fine structures. In this study, we have developed and experimentally verify a comprehensive analytical uncertainty propagation signal variation flow graph (SVFG) model for X-ray radiography in this work to better understand resolution and image variability limits on the small scale. The SVFG approach captures, quantifies, and predicts variations occurring in the system that limit metrology capabilities, particularly in the micro/nanodomain. This work is the first step to achieving full uncertainty modeling of CT reconstructions and provides insight into improving X-ray attenuation imaging systems. The SVFG methodology framework is applied to generate a complete basis set of functions describing the major sources of variation in radiographs. Five models are identified, covering variation in energy, intensity, length, blur, and position. Radiographic system experiments are defined to measure the parameters required by the SVFGs. Best practices are identified for these measurements. The SVFG models are confirmed via direct measurement of variation to predict variation within 30% on average.

47 OTHER INSTRUMENTATION↗

Boosting Hydrogen Evolution in Neutral Medium by Accelerating Water Dissociation with Ru Clusters Loaded on Mo 2 CTx MXene

Abstract Electrocatalytic hydrogen evolution reaction (HER) in mild neutral medium is a compelling goal for environmentally sustainable energy conversion, but its development is greatly limited by slow kinetics. Platinum group noble metals exhibit ultra‐high HER activities, but their scarcity and performance instability restrict wide application. Herein, taking advantage of excellent catalyst carrier properties of 2D‐layered transition metal carbides (MXenes), highly dispersed of Ru clusters anchored on Mo 2 CT x MXene are demonstrated as a superior HER electrocatalyst, which is prepared by a facile in situ reduction strategy. The as‐prepared Ru/Mo 2 CT x catalyst exhibits a very low overpotential of 73 mV to achieve a current density of −10 mA cm −2 and Tafel slope of 57 mV dec −1 in neutral medium, surpassing performance of most previously reported MXene‐based catalysts. In addition, Ru/Mo 2 CT x catalyst also presents superior stability compared to commercial Pt/C. Experimental results and theoretical calculations indicate that the interaction between Ru clusters modulates the electronic structure of active sites and promotes H 2 O dissociation and hydrogen desorption.

Wu, Yanze↗

Responsive Interfacial Assemblies Based on Charge‐Transfer Interactions

Abstract Charge transfer (CT) interactions have been widely used to construct supramolecular systems, such as functional nanostructures and gels. However, to date, there is no report on the generation of CT complexes at the liquid–liquid interface. Here, by using an electron‐deficient acceptor dissolved in water and an electron‐rich donor dissolved in oil, we present the in situ formation and assembly of CT complex surfactants (CTCSs) at the oil–water interface. With time, CTCSs can assemble into higher‐order nanofilms with exceptional mechanical properties, allowing the stabilization of liquids and offering the possibility to structure liquids into nonequilibrium shapes. Moreover, due to the redox‐responsiveness of the electron‐deficient acceptor, the association and dissociation of CTCSs can be reversibly manipulated in a redox process, leading to the switchable assembly and disassembly of the resultant constructs.

Sun, Shuyi↗

Responsive Interfacial Assemblies Based on Charge‐Transfer Interactions

Abstract Charge transfer (CT) interactions have been widely used to construct supramolecular systems, such as functional nanostructures and gels. However, to date, there is no report on the generation of CT complexes at the liquid–liquid interface. Here, by using an electron‐deficient acceptor dissolved in water and an electron‐rich donor dissolved in oil, we present the in situ formation and assembly of CT complex surfactants (CTCSs) at the oil–water interface. With time, CTCSs can assemble into higher‐order nanofilms with exceptional mechanical properties, allowing the stabilization of liquids and offering the possibility to structure liquids into nonequilibrium shapes. Moreover, due to the redox‐responsiveness of the electron‐deficient acceptor, the association and dissociation of CTCSs can be reversibly manipulated in a redox process, leading to the switchable assembly and disassembly of the resultant constructs.

Sun, Shuyi↗

The Wormholes Within: A Study of 1, 3, 5–Triamino–2, 4, 6–Trinitrobenzene Crystal Morphology by Micro and Nano–Scale X–Ray Computed Tomography and its Effects Upon the Shock Sensitivity of Detonation

We report that we understand heterogeneous-explosive detonation only to the extent that we can first measure the salient chemical and microstructural features. Barring an inordinate amount of trial and error, we can tailor the detonation properties of our HE formulations only to the extent that we understand (at least qualitatively) the same effects. As an insensitive high explosive, 1, 3, 5-triamino-2, 4, 6-trinitrobenzene (TATB) burns more heterogeneously than conventional high explosives, making its detonation properties sensitive to microstructure. The Benziger route can produce various grain morphologies depending on the amount of water used in the amination step. So-called dry-aminated (DA) TATB crystals are riddled with a void structure called wormholes, which are washed out ammonium chloride (NH4Cl) inclusions that form during synthesis. So-called wet-aminated (WA) TATB crystals do not contain NH 4 Cl inclusions but possess a very convoluted external structure. Using both micro and nano-scale CT, we explore three DA-TATB lots that reflect evolutionary processing changes, plus one WA-TATB material. Micro CT imaged crystal collections show the exterior grain structure, revealing its roughness and providing a crude particle size measurement. The DA-TATB lots that test most sensitively in the LANL ECOT corner-turning test are roughest, having the appearance of being “corroded”. Nano-scale CT reveals both internal NH 4 Cl inclusions and void structures. The DA-TATB lots that tested intermediate and high sensitivity in ECOT exhibited similar wormhole structures, which were more extensive than that of the low-sensitivity lot. The least sensitive DA-TATB lot also retained more NH 4 Cl, consistent with reduced connectivity of voids to the surface.

1, 3, 5-triamino-2,4↗

Tomographic X-ray particle tracking velocimetry

We investigate the feasibility of in-laboratory tomographic X-ray particle tracking velocimetry (TXPTV) and consider creeping flows with nearly density matched flow tracers. Specifically, in these proof-of-concept experiments we examined a Poiseuille flow, flow through porous media and a multiphase flow with a Taylor bubble. For a full 360° computed tomography (CT) scan we show that the specially selected 60 micron tracer particles could be imaged in less than 3 seconds with a signal-to-noise ratio between the tracers and the fluid of 2.5, sufficient to achieve proper volumetric segmentation at each time step. In the pipe flow, continuous Lagrangian particle trajectories were obtained, after which all the standard techniques used for PTV or PIV (taken at visible wave lengths) could also be employed for TXPTV data. And, with TXPTV we can examine flows inaccessible with visible wave lengths due to opaque media or numerous refractive interfaces. In the case of opaque porous media we were able to observe material accumulation and pore clogging, and for flow with Taylor bubble we can trace the particles and hence obtain velocities in the liquid film between the wall and bubble, with thickness of liquid film itself also simultaneously obtained from the volumetric reconstruction after segmentation. While improvements in scan speed are anticipated due to continuing improvements in CT system components, we show that for the flows examined even the presently available CT systems could yield quantitative flow data with the primary limitation being the quality of available flow tracers.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Out-of-Distribution Detection and Radiological Data Monitoring Using Statistical Process Control

Abstract Machine learning (ML) models often fail with data that deviates from their training distribution. This is a significant concern for ML-enabled devices as data drift may lead to unexpected performance. This work introduces a new framework for out of distribution (OOD) detection and data drift monitoring that combines ML and geometric methods with statistical process control (SPC). We investigated different design choices, including methods for extracting feature representations and drift quantification for OOD detection in individual images and as an approach for input data monitoring. We evaluated the framework for both identifying OOD images and demonstrating the ability to detect shifts in data streams over time. We demonstrated a proof-of-concept via the following tasks: 1) differentiating axial vs. non-axial CT images, 2) differentiating CXR vs. other radiographic imaging modalities, and 3) differentiating adult CXR vs. pediatric CXR. For the identification of individual OOD images, our framework achieved high sensitivity in detecting OOD inputs: 0.980 in CT, 0.984 in CXR, and 0.854 in pediatric CXR. Our framework is also adept at monitoring data streams and identifying the time a drift occurred. In our simulations tracking drift over time, it effectively detected a shift from CXR to non-CXR instantly, a transition from axial to non-axial CT within few days, and a drift from adult to pediatric CXRs within a day—all while maintaining a low false positive rate. Through additional experiments, we demonstrate the framework is modality-agnostic and independent from the underlying model structure, making it highly customizable for specific applications and broadly applicable across different imaging modalities and deployed ML models.

Zamzmi, Ghada↗