At least 271 records · Page 15

Effect of Minor Ce Additions on Corrosion Behavior of Experimental Pipeline Steel

Minor additions of rare earth elements (REEs) have been shown to improve various steel properties. In particular, Cerium (Ce), as a relatively abundant and inexpensive element, has received attention as a potentially beneficial minor alloying addition for a variety of steel applications, including pipelines materials. The objective of this work is to investigate the effect of Ce on corrosion performance of experimental high-strength pipeline steel. Electrochemical corrosion experiments were carried out on steel without and with 0.006, 0.018, and 0.03 wt.% of Ce in 3.5 wt.% NaCl saturated with CO2 at 20 oC. For comparison purposes, X100 carbon steel specimens machined from an experimental pipe with a yield strength of 731 MPa were tested under the same conditions. The electrochemical techniques employed included: potentiodynamic polarization (PDP), linear polarization resistance (LPR), and electrochemical impedance spectroscopy (EIS). In addition, post-corrosion surface characterization was performed using scanning electron microscopy (SEM) equipped with energy dispersive X-ray spectroscopy (EDS), while crystalline phases were determined by X-ray diffraction (XRD). The corrosion of base metal without Ce was lower (0.15 mm/y) compared to carbon steel X100 (0.9 mm/yr). The electrochemical results showed that adding Ce accelerates corrosion rates compared to base metal without Ce. No pitting corrosion of tested steel was detected.

Belarbi, Zineb↗

Effectiveness of Vapor Corrosion Inhibitors Under Elevated Chloride Conditions for Aboveground Storage Tank Application

The sand quality used to construct the tank pad is an important contributing factor to the rate of corrosion that occurs on the soil-side of the aboveground storage tanks (ASTs) floor plates. Clean sand that meets specific criteria provides the first line of defense for mitigation of tank floor corrosion. However, it has been observed that the sand quality used for some existing tanks differ greatly from the specifications provided in the API 651 standard; this could be partially due to initial sand quality not meeting the specification, and partially due to the environmental effects over time. For example, rain-water intrusion could lead to higher than the specified contents of corrosive species such as chloride. Tank operators are increasingly using vapor corrosion inhibitors (VCIs) either as a stand alone or in combination with cathodic protection (CP) for ASTs to mitigate soil-side corrosion. VCIs are delivered either through-thefloor or injected through the ports in the ring wall. Experimental studies were conducted to evaluate VCIs’ performance at elevated chloride concentrations and to study the effectiveness of the delivery methods under extreme chloride conditions. The experimental work found that VCI performance is robust and not compromised due to high chloride levels, such as 300 ppm or more. The work also showed that the through-the-floor VCI delivery method is more beneficial compared to the through-the-sand-pad method when tank pad corrosivity is elevated.

Shukla, Pavan K.↗

Effectiveness of Vapor Corrosion Inhibitors Under Bacterial Activity for Aboveground Storage Tank Application

Bacterial activity is known to influence corrosion and can result in increasing soil-side corrosion of the aboveground storage tanks (ASTs) floor plates. Association for Materials Protection and Performance (AMPP) defines this phenomenon as Microbiologically Influenced Corrosion (MIC). It has been hypothesized that vapor corrosion inhibitors (VCIs) can not only function in presence of bacterial activity but can also function as biocides. Experiments were conducted to study the effect of bacterial activity on corrosion in the sand pad conditions and effect of VCIs in mitigating MIC. Various bacteria cultures were grown using commercially available culture media, and coupon exposure tests were performed with field sand mixed with the culture media. To this end, control and VCI-dosed electrolytes were prepared using the field sand plus bacteria cultures. Pre- and post-test bacteria concentration estimation and measurements, respectively, in the VCI-dosed electrolytes indicated that VCIs do not function as biocides, however, VCIs are highly effective for mitigating corrosion in presence of bacterial activity.

Shukla, Pavan K.↗

Characterization of wellbore casing corrosion product as a permeable porous medium

Leakage along wellbores is of concern for a variety of applications, including sub-surface fluid storage facilities, geothermal wells, and CO 2 storage wells. We have investigated whether corroded casing is permeable to gas and can serve as a leakage pathway along wellbores. Three specimens were prepared from laboratory steel plates corroded using different mechanisms to reflect different possible field conditions and produce a variety of corrosion rates. Single-phase gas flow measurements were made under a range of gas pressures to investigate flow in both the viscous and visco-inertial flow regimes. Tests were conducted at different confining stresses (range from 3.45 to 13.79 MPa) following both loading and unloading paths. The gas flow test results imply corroded casing can serve as a significant leakage path along the axis of a wellbore. Transmissivity was discovered to be sensitive to the variation in confining stress suggesting that the corrosion product is deformable. Gas slip factors and the coefficients of inertial resistance of the corrosion product were comparable to those available in the literature for other porous media. Post-test examination of the corrosion product revealed it to be a heterogeneous, mesoporous material with mostly non-uniform slit type porosity. There was no discernable difference in the composition of corrosion product from specimens corroded by different mechanisms.

02 PETROLEUM↗

Time-Dependent Corrosion Behavior of Aluminum Using Advanced Electrochemical and Characterization Techniques

The time-dependent corrosion behavior of pure aluminum (Al) in a chloride-containing environment was investigated using various electrochemical and characterization techniques for up to 336 h. Transmission electron microscopic and secondary ion mass spectroscopic analysis revealed the continuous dissolution of the surface film over the immersion time. In the meantime, the increasing passive oxide thickness resulted in the surface film resistance enhancement over the immersion time, as indicated by the electrochemical impedance spectroscopic analysis. The electrochemical noise measurements showed an increase in the corrosion kinetics with immersion time until 60 h because of the accelerated localized corrosion in the early stage of immersion. However, an inhibition in corrosion kinetics occurred after longer immersion times due to corrosion product deposition inside the pit.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Corrosivity Screening of Pyrolysis Bio-Oils by Short-Term Alloy Exposures. Laboratory Analytical Procedure (LAP), Issue Date: May 12, 2022

Bio-oils contain organic acids and oxygenated compounds that can lead to corrosion issues during bio-oil processing and storage. This Laboratory Analytical Procedure (LAP) allows for rapid screening of a bio-oil's corrosivity without the need for complex equipment and long-term exposures. A robust and repeatable method for assessing the corrosivity of bio-oils is necessary in order to remove materials degradation as an obstacle to research, upgrading, use and storage of bio-oils. This LAP involves the incubation of a representative alloy, 410 stainless steel (410 SS), specimen in bio-oil over a period of 48 hours at 50 degrees C in a sealed container. The corrosive species in the bio-oil react with and deplete alloy elements such as iron (Fe) and/or chromium (Cr) from the specimen into the bio-oil solution. The depletion of Fe and Cr from the specimen results in a significant mass loss that can be recorded. The mass loss is directly correlated to the corrosivity of a bio-oil. Examples of bio-oils in scope include the ones produced by fast pyrolysis and catalytic fast pyrolysis, as well as liquids produced from hydrothermal liquefaction.

09 BIOMASS FUELS↗

Effect of Carboxylic Acids on Corrosion of Type 410 Stainless Steel in Pyrolysis Bio-Oil

Biomass-derived oils are renewable fuel sources and commodity products and are proposed to partially or entirely replace fossil fuels in sectors generally considered difficult to decarbonize such as aviation and maritime propulsion. Bio-oils contain a range of organic compounds with varying functional groups which can lead to polarity-driven phase separation and corrosion of containment materials during processing and storage. Polar compounds, such as organic acids and other oxygenates, are abundant in bio-oils and are considered corrosive to structural alloys, particularly to those with a low-Cr content. To study the corrosion effects of small carboxylic acids present in pyrolysis bio-oils, type 410 stainless steel (SS410) specimens were exposed in bio-oils with varying formic, acetic, propionic and hexanoic acid contents at 50 °C during 48 h exposures. The specific mass change data show a linear increase in mass loss with increasing formic acid concentration. Interestingly, a mild corrosion inhibition effect on the corrosion of SS410 specimens was observed with the addition of acetic, propionic and hexanoic acids in the bio-oil.

09 BIOMASS FUELS↗

Laser Surface Processing of Alloys for Corrosion Protection (Final Project Report of Marine Energy Seedling Project)

This is the final project report for the MHK Seedling project. The report describes use of laser surface processing (LSP) to modify the surface of test materials (Al, steel) and the corrosion testing performed on the resulting samples in different corrosion environments. Data shows that LSP improved the corrosion resistance of Al and steel used in this work relative to respective non-LSP samples. The data also showed that each material had a specific range of laser processing conditions where the beneficial effects of LSP (i.e. improvement in corrosion protection) were observed. Application of LSP to enable low-cost materials in marine environments, additional microstructural analysis and long-term testing are proposed to further develop this technology for marine renewable energy and systems.

36 MATERIALS SCIENCE↗

Variation of the Passive Film on Compositionally Concentrated Dual-Phase Al 0.3 Cr 0.5 Fe 2 Mn 0.25 Mo 0.15 Ni 1.5 Ti 0.3 and Implications for Corrosion

The passive film on a dual-phase Al 0.3 Cr 0.5 Fe 2 Mn 0.25 Mo 0.15 Ni 1.5 Ti 0.3 FCC + Heusler (L2 1 ) compositionally concentrated alloy formed during extended exposure to an applied potential in the passive range in dilute chloride solution was characterized. Each phase, with its own distinct composition of passivating elements, formed unique passive films separated by a heterophase interface. High-resolution, surface sensitive characterization enabled chemical analysis of the passive film formed over individual phases. The film formed over the L2 1 phase had a higher concentration of Al, Ni, and Ti, while the film formed over FCC phase was of similar thickness but contained comparatively higher Cr, Fe, and Mo concentrations, consistent with the differences in bulk microstructure composition. The passive film was continuous across phase boundaries and the distribution of passivating elements (Al, Cr, and Ti) indicated both phases were independently passivated. Spatially resolved analysis of the surface chemistry of the dual-phase CCA revealed that the cation with the highest composition in passive film formed on the FCC phase was Cr (52.4 at. pct) and for the L2 1 phase was Ti (53.1 at. pct) despite the bulk concentration of each element being below 20 at. pct in their respective phases. Al, Cr, and Ti were enriched in both phases within the passive film relative to their respective bulk compositions. In parallel studies, single-phase alloys with compositions representative of the FCC and L2 1 phases were synthesized to evaluate the corrosion behavior of each phase in isolation. The corrosion behavior of the dual-phase alloy showed passivity evidenced by a pitting potential of 0.615 V SCE in 0.01 M NaCl. The pitting potential and other electrochemical parameters suggested a combination of behaviors of both single-phase samples, suggesting that the global corrosion behavior may be represented by a composite theory applied to phases, their area fractions, and interphase length. However, the interphase in the dual-phase CCA was a local corrosion initiation site and may limit localized corrosion protectiveness. The alloy design implications for optimization of second phase structure and morphology are discussed.

36 MATERIALS SCIENCE↗

An Investigation of the Corrosion Mechanisms of Cu-7Ni-3Al-1Fe-1Mn Alloy in Chloride-Containing Environment

The corrosion mechanisms of Cu-7Ni-3Al-1Fe-1Mn (wt.%) alloy in a 3.5% NaCl solution are investigated through a multi-analytical approach. The formation, growth and stable corrosion stage of the stable corrosion layer are reflected by the change of electrochemical response with time. EDS and GI-XRD results show the presence of Cu{sub 2}(OH){sub 3}Cl and Cu{sub 2}O that are the main corrosion products, with the former predominantly present at topmost corrosion layer, and Cu{sub 2}O is mainly located in the inner part, followed by aluminum oxide closer to the alloy substrate.

36 MATERIALS SCIENCE↗

Relationship Between Microstructure and Marine Corrosion Resistance of Martensitic Stainless Steels: A Multiscale Approach

The electrochemical properties of martensitic stainless steels may depend on complex aspects of their microstructure. Three alloys were considered in this study: X30Cr13 (AISI 420), a martensitic stainless steel with a low content of alloying elements; X17CrNi16-2 (AISI 431), chosen for its strong resistance to corrosion; and X5CrNiCu15-5 (AISI 630), chosen for its good mechanical resistance. Voltammetry tests have shown the influence of carbon and chromium content on corrosion resistance. Resistance to pitting appears equivalent for the both. However, heterogeneous corrosion, in relation to δ-ferrite precipitation and chromium carbides at the lath boundaries, appears in the case of X17CrNi16-2. Conversely, non-preferential corrosion occurs in the case of the X5CrNiCu15-5, and a superior passive film stability during immersion in artificial seawater. This counterbalance negative effect of the microstructure. Thus, it achieves an equivalent “macroscopically” corrosion behavior between the two steels.

36 MATERIALS SCIENCE↗

Effect of Sulfide Concentration on the Corrosion and Cavitation Erosion Behavior of a Manganese-Aluminum Bronze in 3.5% NaCl Solution

The effect of sulfide concentration on the corrosion and cavitation erosion behavior of a cast manganese-aluminum bronze (MAB) alloy in 3.5% NaCl solution was investigated. The electrochemical results showed that when the sulfide concentration exceeded 50 ppm, hydrogen evolution reaction dominated the cathodic process because of the very negative corrosion potential of MAB, and the formation of a copper sulfide film on MAB was a diffusion-controlled process. The mass loss rate of MAB after longer-term immersion was ordered by the sulfide concentration as: 20/50 ppm > 100 ppm > zero > 200 ppm. In the 200 ppm sulfide solution, the mass loss rate of MAB was the lowest, because of the formation of a thin and homogeneous copper sulfide film. In the other sulfide solutions, the formation of a less-protective film with both oxides and sulfides resulted in higher mass loss rate of MAB. Moreover, selective phase corrosion occurred at the β and κ phases in solutions with sulfide addition less than 100 ppm. For all solutions, it was the mechanical attack that dominated cavitation erosion degradation. The cavitation erosion–corrosion synergy was lower in high sulfide solutions, because the corrosion products on MAB could reduce the mechanical impact under cavitation erosion.

36 MATERIALS SCIENCE↗

Effect of Carbon Nanotube Concentration on the Corrosion Behavior of Electroless Ni-B-CNT Coating

In this study, Ni-B-CNT composite was deposited on AISI 4140 steel using different concentrations of CNTs ranging from 0.2 to 1 gr/lit in an electroless bath. The phase analysis and surface morphology of the samples were characterized using x-ray diffraction and FESEM. The corrosion behavior of the coated samples was investigated in a 3.5 wt.% NaCl solution through potentiodynamic polarization, EIS, and electrochemical noise (EN) analyses. The corroded surface of the samples was further analyzed via FESEM observation after 10 days of immersion in corrosive medium. It was found that although adding 0.2 gr/lit CNT in electroless solution improves corrosion resistance, increasing CNT concentration from 0.2 up to 1 gr/lit increases the corrosion rate. The FESEM observations and EN results imply that the formation of micro-galvanic cells in samples with high concentration of CNTs leads to nucleation and growth of the pits. The results revealed that no passive layer was formed on the surface of the Ni-B sample, and the corrosion occurred through ionic diffusion into the cracks and crevices. The results of potentiodynamic test show that adding CNTs into electroless bath facilitates the formation of passive layer. However, results of EN test imply that increasing CNT concentration causes repetitive breakdown and recovery of passive film.

36 MATERIALS SCIENCE↗

Atomic Layer-Deposited Al{sub 2}O{sub 3} Interlayer for Improved Tribological and Anti-corrosion Properties of TiN Hard Coating on 316L Stainless Steel

A dense Al{sub 2}O{sub 3} interlayer was inserted into TiN to enhance the tribological and anti-corrosion properties of TiN hard coating via a hybrid process of magnetron sputtering and atomic layer deposition (ALD). The influence of the ALD-Al{sub 2}O{sub 3} layer on the microstructure, mechanical, tribological and anti-corrosion properties of TiN was examined. The TiN-Al{sub 2}O{sub 3} coating exhibits low friction coefficient and specific wear rate, due to the structure change and columnar refinement caused by the addition of amorphous ALD-Al{sub 2}O{sub 3} interlay which improves the mechanical properties of hard coating. The improved corrosion properties of TiN are attributed to the fact that the insulating ALD-Al{sub 2}O{sub 3} used as a sealing layer can prevent the corrosive chlorine ions migrating into the lower TiN layer and block the charge transport in coatings. Moreover, raising the insertion position of ALD-Al{sub 2}O{sub 3} layer away from the steel substrate results in a further increase in the anti-corrosion property of TiN-Al{sub 2}O{sub 3} composite coating.

36 MATERIALS SCIENCE↗

Mechanistic modeling of copper corrosions in data center environments

Air-side economizers are increasingly used to take advantage of “free-cooling” in data centers with the intent of reducing the carbon footprint of buildings. However, they can introduce outdoor pollutants to indoor environment of data centers and cause corrosion damage to the information technology equipment. Here, to evaluate the reliability of information technology equipment under various thermal and air-pollution conditions, a mechanistic model based on multi-ion transport and chemical reactions was developed. The model was used to predict Cu corrosion caused by Cl2-containing pollutant mixtures. It also accounted for the effects of temperature (25 °C and 28 °C), relative humidity (50%, 75%, and 95%), and synergism. It also identified higher air temperature as a corrosion barrier and higher relative humidity as a corrosion accelerator, which agreed well with the experimental results. The average root mean square error of the prediction was 13.7 Å. The model can be used to evaluate the thermal guideline for data centers design and operation when Cl2 is present based on pre-established acceptable risk of corrosion in data centers’ environment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Localized corrosion at nm-scale hardening precipitates in Al-Cu-Li alloys

The localized corrosion of Li-containing nm hardening precipitates in the 3rd generation of Al-Cu-Li alloys was investigated based on a quasi in situ approach by sequentially exposing the material to NaCl solution and characterizing the structural, chemical, and electrochemical evolution at atomic scale using electron microscopy, spectroscopy, 3D tomography, electrochemical measurements, and DFT calculations. Localized corrosion of Al 7.5 Cu 4 Li (TB phase) initiated along {001} family of planes through the dealloying of Al and Li due to a low surface work function. Cu was enriched along the Cu (110) // T B (011) // Al (100) orientations on and around corroded T B precipitates. No strong galvanic interactions were observed at the T B and Al matrix interface due to the formation of a Li-C-O rich passivation layer during electrolyte exposure. Similarities and differences between T B and other common Al-Cu-Li precipitates (Al 2 CuLi, Al 6 CuLi 3 , and Al 3 Li) with respect to corrosion are discussed. Overall, the reported corrosion mechanism can assist in the assessment of the localized corrosion susceptibility of precipitation-hardened Al alloys and assist in the design of new alloys.

36 MATERIALS SCIENCE↗

Cathodic corrosion: 21st century insights into a 19th century phenomenon

Cathodic corrosion is an enigmatic electrochemical process that etches metallic electrodes at potentials below 0 V versus the normal hydrogen electrode. Although this phenomenon was discovered in the late 1800s by Fritz Haber, it remained mostly unnoticed during the 20th century and only attracted increased attention in the past decade. This recent attention has generated marked improvements in both the fundamental knowledge and the applications of cathodic corrosion. Fundamental new insights were gained into the effects and possible reaction intermediates of cathodic corrosion. Complementing these insights, recent advances involve applications of cathodic corrosion for nanoparticle synthesis and electrocatalyst modification. Both these applied and fundamental advances will be discussed in this short review on cathodic corrosion.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of substrate orientation and anisotropic strength on corrosion pits

The complexities of pitting corrosion and its associated pit morphologies are critical for predicting and preventing pit-related failure in materials. With the advances in computational tools, modeling of pitting corrosion has lately gained momentum. We recently developed a phase field model for 3-D pit morphology, and in the current work, the model is utilized to gain insight into the role of substrate orientation and anisotropic strength on crystallographic pits. The influence of these parameters on pit morphology and corrosion metrics such as pit volume, current, pit area, current density, and pit depth are studied. The crystallographic pit morphology changes with substrate orientation but not significantly with anisotropic strength. Finally, the anisotropic strength strongly influences the corrosion metrics whereas most corrosion metrics remain unaffected by substrate orientation.

36 MATERIALS SCIENCE↗