Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CONTAMINATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Performance Losses and Current-Driven Recovery from Cation Contaminants in PEM Water Electrolysis

Water contaminants are a common cause of failure for polymer electrolyte membrane (PEM) electrolyzers in the field as well as a confounding factor in research on cell performance and durability. In this study, we investigated the performance impacts of feed water containing representative tap water cations at concentrations ranging from 0.5–500 μ M, with conductivities spanning from ASTM Type II to tap-water levels. We present multiple diagnostic signatures to help identify the presence of contaminants in PEM electrolysis cells. Through analysis of polarization curves and impedance spectroscopy to understand the origins of performance losses, we found that a switch from the acidic to alkaline hydrogen evolution mechanism is a key factor in contaminated cell behavior. Finally, we demonstrated that this mechanism switching can be harnessed to remove cation contaminants and recover cell performance without the use of an acid wash. We demonstrated near-complete recovery of cells contaminated with sodium and calcium, and partial recovery of a cell contaminated with iron, which was further investigated by post-mortem microscopy. The improved understanding of contaminant impacts from this work can inform development of strategies to mitigate or recover performance losses as well as improve the consistency and rigor of electrolysis research.

30 DIRECT ENERGY CONVERSION↗

A Murine Model of Radionuclide Lung Contamination for the Evaluation of Americium Decorporation Treatments

The hydroxypyridinone ligand 3,4,3-LI(1,2-HOPO) (HOPO), has been previously characterized as a promising chelating agent for in vivo decorporation of actinides, with decorporation being the removal of internally deposited contaminants from the body after exposure. The large majority of relevant literature reports have detailed the efficacy profile of HOPO as a decorporation agent in rodent models, where controlled radionuclide contamination is conducted via intravenous injection. However, this method of contamination does not necessarily reflect an accurate predictive model of the most probable biodistribution of free metal in the body. In the event of a radiological dispersal device or nuclear power plant accident scenario, it is most likely that first responders, military personnel, and victims of the event will be contaminated via air and water transmission. Therefore, research into the efficacy of chelating agents to treat lung-contaminated in vivo models needs to be carried out. Here, we establish a murine model with controlled, reproducible lung contamination using two different radionuclides, 89Zr and 241Am, for orthogonal biodistribution validation by positron emission tomography and ex vivo radioanalysis, respectively. In addition, we report effective chelation treatment of 241Am-contaminated lungs using HOPO, which improves decorporation by up to 40% compared to Ca-DTPA, the current standard of care.

Arino, Trevor↗

Remedy Evaluation Framework for Inorganic, Non-Volatile Contaminants in the Vadose Zone

Contaminants in the vadose zone may act as a potential long-term source of groundwater contamination and need to be considered in remedy evaluations. In many cases, remediation decisions for the vadose zone will need to be made all or in part based on projected impacts to groundwater. Because there are significant natural attenuation processes inherent in vadose zone contaminant transport, remediation in the vadose zone to protect groundwater is functionally a combination of natural attenuation and use of other remediation techniques, as needed, to mitigate contaminant flux to groundwater. Attenuation processes include both hydrobiogeochemical processes that serve to retain contaminants within porous media and physical processes that mitigate the rate of water flux. In particular, the physical processes controlling fluid flow in the vadose zone are quite different and generally have a more significant attenuation impact on contaminant transport relative to those within the groundwater system. A remedy evaluation framework is presented herein that uses an adaptation of the established EPA Monitored Natural Attenuation (MNA) evaluation approach and a conceptual model based approach focused on identifying and quantifying features and processes that control contaminant flux through the vadose zone. A key concept for this framework is to recognize that MNA will comprise some portion of all remedies in the vadose zone. Thus, structuring evaluation of vadose zone waste sites to use an MNA-based approach provides information necessary to either select MNA as the remedy, if appropriate, or to quantify how much additional attenuation would need to be induced by a remedial action (e.g., technologies considered in a feasibility study) to augment the natural attenuation processes and meet groundwater protection goals.

natural attenuation↗

Determination of the Effect of Coal/Biomass-Derived Syngas Contaminants on the Performance of Fischer-Tropsch and Water-Gas-Shift Catalysts

Today, nearly all liquid fuels and commodity chemicals are produced from non-renewable resources such as crude oil and natural gas. Because of increasing scrutiny of carbon dioxide (CO 2 ) emissions produced using traditional fossil-fuel resources, the utilization of alternative feedstocks for the production of power, hydrogen, value-added chemicals, and high-quality hydrocarbon fuels such as diesel and substitute natural gas (SNG) is critical to meeting the rapidly growing energy needs of modern society. Coal and biomass are particularly attractive as alternative feedstocks because of the abundant reserves of these resources worldwide. The strategy of co-gasification of coal/biomass (CB) mixtures to produce syngas for synthesis of Fischer-Tropsch (FT) fuels offers distinct advantages over gasification of either coal or biomass alone. Co-feeding coal with biomass offers the opportunity to exploit economies of scale that are difficult to achieve in biomass gasification, while the addition of biomass to the coal gasifier feed leverages proven coal gasification technology and allows CO 2 credit benefits. Syngas generated from CB mixtures will have a unique contaminant composition because coal and biomass possess different concentrations and types of contaminants, and the final syngas composition is also strongly influenced by the gasification technology used. Syngas cleanup for gasification of CB mixtures will need to address this unique contaminant composition to support downstream processing and equipment. To investigate the impact of CB gasification on the production of transportation fuels by FT synthesis, RTI International conducted thermodynamic studies to identify trace contaminants that will react with water-gas-shift and FT catalysts and built several automated microreactor systems to investigate the effect of single components and the synergistic effects of multiple contaminants on water-gas-shift and FT catalyst performance. The contaminants investigated were sodium chloride (NaCl), potassium chloride (KCl), hydrogen sulfide (H 2 S), carbonyl sulfide (COS), ammonia (NH 3 ), and combinations thereof. This report details the thermodynamic studies and the individual and multi-contaminant results from this testing program.

10 SYNTHETIC FUELS↗

Healthy Zero Energy Buildings (HZEB) Program - Cross-Sectional Study of Contaminant Levels, Source, Strengths, and Ventilation Rates in Retail Stores

This field study measured ventilation rates and indoor air quality parameters in 21 visits to retail stores in California. The data was collected to guide the development of new, science-based commercial building ventilation rate standards that balance the dual objectives of increasing energy efficiency and maintaining acceptable indoor air quality. Data collection occurred between September 2011 and March 2013. Three types of stores participated in this study: grocery stores, furniture/hardware stores, and apparel stores. Ventilation rates and indoor air contaminant concentrations were measured on a weekday, typically between 9 am and 6 pm. Ventilation rates measured using a tracer gas decay method exceeded the minimum requirement of California’s Title 24 Standard in all but one store. Even though there was adequate ventilation according to Title 24, concentrations of formaldehyde, acetaldehyde, and acrolein exceeded the most stringent chronic health guidelines. Other indoor air contaminants measured included carbon dioxide (CO{sub 2}), carbon monoxide (CO), ozone (O{sub 3}), and particulate matter (PM). Concentrations of CO{sub 2} were kept low by adequate ventilation, and were assumed low also because the sampling occurred on a weekday when retail stores were less busy. CO concentrations were also low. The indoor-outdoor ratios of O{sub 3} showed that the first-order loss rate may vary by store trade types and also by ventilation mode (mechanical versus natural). Analysis of fine and ultrafine PM measurements showed that a substantial portion of the particle mass in grocery stores with cooking-related emissions was in particles less than 0.3 μm. Stores without cooking as an indoor source had PM size distributions that were more similar indoors and outdoors. The whole-building emission rates of volatile organic compounds (VOCs) and PM were estimated from the measured ventilation rates and indoor and outdoor contaminant concentrations. Mass balance models were then used to determine the ventilation rates, filtration strategies, or source reductions needed to maintain indoor contaminant concentrations below reference levels. Several scenarios of potential concern were considered: (i) formaldehyde levels in furniture/hardware stores, (ii) contaminants associated with cooking (e.g., PM, acrolein, and acetaldehyde) in grocery stores, and (iii) outdoor contaminants (e.g., PM and O{sub 3}) impacting stores that use natural ventilation. Estimated formaldehyde emission rates suggest that retail stores would need to ventilate at levels far exceeding the current Title 24 requirement to lower indoor concentrations below California’s stringent formaldehyde reference level. Given the high costs of providing ventilation but only modest chronic health benefit is expected, effective source control is an attractive alternative, as demonstrated by some retail stores in this study. Predictions showed that grocery stores need MERV 13 air filters, instead of MERV 8 filters that are more commonly used, to maintain indoor PM at levels that meet the chronic health standards for PM. Exposure to acrolein is a potential health concern in grocery stores, and should be addressed by increasing the use of kitchen range hoods or improving their contaminant removal efficiency. In stores that rely on natural ventilation, indoor PM can be a health concern if the stores are located in areas with high outdoor PM. This concern may be addressed by switching to mechanical ventilation when the outdoor air quality is poor, while continuing natural ventilation when outdoor air quality is good.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Contaminant Stabilization Technology Gap Report

After an intentional radiological release or nuclear power plant (NPP) accidental release, there may be a large area that is contaminated. Re-suspension and tracking of contamination may create issues with containing the contaminated area and create additional exposure to responders. There is a need for technologies/methodologies to reduce resuspension and tracking. Current radiological particle containment relies on securing the area, setting up a single egress and ingress route, and minimizing the amount of contaminated equipment and vehicles leaving the contaminated zone. The re-suspension and tracking of contamination greatly hampers the ability to conduct first response activities in that zone therefore technologies that can reduce these spreading mechanisms are needed. In the NPP decommissioning industry, coatings are employed to reduce the spread of contamination. These coatings may not be readily available in the quantities needed for early response. Responders need containment methodologies that can be employed with existing equipment and materials on site using techniques such as fire hosing, street sweepers, and painting. A review by Parra et al. (2009) provided a good overview of fixative/stabilization materials, which formed the basis (in addition to a literature search) for a list of potential technologies presented to stakeholders in the initial stages of this work. Advantages and disadvantages were identified for each of the technologies, which were grouped into tiers based on the time-frame they would be available following a radiological release. Stakeholders then ranked containment technologies in terms of their preference and interest in use and availability. The final part of this task is to gather more information on the stakeholder-selected technologies and identify technical gaps that need to be filled with experimental research before technical procedures can be developed for containment technology use in the field.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Removable, Sequestration Coatings for Mitigating Hazardous Contaminants Related to Deactivation and Decommissioning Activities

This project is a collaborative effort between InnoSense LLC (ISL) and Oak Ridge National Laboratory (ORNL) aimed at mitigating the mercury (Hg) contamination problem at the Y-12 National Security Complex (NSC). The report summarizes the research and technology development work of the Phase IIB Project, led by Dr. Uma Sampathkumaran at ISL for the period of July 31, 2017–October 31, 2021. The Y-12 site cleanup includes technologies for safe and cost-effective facility demolition, soil remediation, and on-site treatment and disposal of mercury bearing wastes. One of the technology demonstration goals was a reactive strippable coating for targeted pre-demolition and de-contamination to limit Hg mobilization and the volume of debris requiring treatment for disposal. Toward this, ISL has developed a water-based reactive strippable coating (Trap & See-Hg™) to sequester elemental Hg(0) and mercuric Hg(II) species in the coating. The coating provides multiple benefits including (1) Hg vapor suppression, (2) sealing in the hazardous contaminants, (3) visually locating the contaminant through color changes, and (4) remediating the contaminated surfaces upon coating removal. Through collaboration between ORNL and ISL in Phase II work, the team successfully demonstrated the Trap & See-Hg technology to (1) visually locate the presence of Hg on concrete, soil and drywall surfaces, (2) effectively sequester all mercury species (elemental, soluble and insoluble Hg) from lab-generated and ex-situ soil and brick/rubble samples collected from the Y 12 site with 80 to 95% efficiency to capture/reduce Hg vapor concentration, (3) be applied by manual and robotic spray applicators and cure at room ambient, (4) remain a cohesive and peelable coating upon drying, and (5) sequester Hg0 from walls in the alpha-2 building basement at Y-12 during a small scale in-situ field trial. In Phase IIB, ISL’s effort was focused on refining the coating formulations with additives containing passive and reactive sorbents, colorimetric indicator, and thixotropic agents to achieve the desired performance. The paints were then evaluated at ORNL for applicability to metal and concrete surfaces of different sizes and shapes, and soil rubble, Hg-sorption capacity and achieving sag-free coating on surfaces when applied by a manual spray applicator. Ambient cure of the coating resulted in a dry thickness of 16–20 mil. The coatings were removed from smooth or rough surfaces with low to moderate force. Both lab-generated Hg-contaminated samples and soil and brick/rubble samples containing a range of Hg concentrations (collected from the Y-12 site by UCOR) were used in this project. Optimized formulations were applied to these samples and evaluated for ability to suppress Hg vapors, sequester Hg 0 and Hg(II) species and color mapping of mercury species on the test surface. The ORNL team initially identified three to four potential sites at Y-12 and ORNL for potential demonstration. However, the pandemic closed any possible avenues for on-site demonstration of the robotic spray applicator. The metal and concrete samples with low to high Hg content provided by UCOR from an ongoing demolition were subsequently used for ex-situ sample characterization and analysis at ORNL over a period of 25 days. The coatings suppressed Hg vapors with an efficiency of 95–99% from heavily contaminated metal and 60% from concrete substrate. Analysis of total Hg in the peeled paints indicates sorption capacities ranging from 12 µg Hg/g of paint from concrete to 1.2 mg Hg/g of paint from the metal substrates while peeled paints from soil samples could capture a total Hg from 2.3 mg Hg/g to 66 mg/g paint. Toxicity characteristic leaching procedure (TCLP) tests recovered total mercury leached at 0.15±0.0008 µg/L for concrete to 126.81±0.67 µg/L and 377.25±5.67 µg/L for the two metal substrates, to allow for informed decisions on downstream disposal considerations. Together, this Phase IIB demonstrated the potential value of the Trap & See-Hg for Hg uptake, vapor suppression, and color mapping, and may thus be used to enhance worker safety during site cleanup, facility demolition, and downstream waste disposal at Y-12 NSC.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Non-reactive facet specific adsorption as a route to remediation of chlorinated organic contaminants

The present work quantifies metal-contaminant interactions between palladium substrates and three salient chlorinated organic contaminants, namely trichloroethylene 1,3,5-trichlorobenzene (TCB), and 3,3′,4,4′-tetrachlorobiphenyl (PCB77). Given that Pd is one of the conventional catalytically active materials known for contaminant removal, maximizing catalytic efficiency through optimal adsorption dynamics reduces the cost of remediation of contaminants that are persistent water pollutants chronically affecting public health. Adsorption efficiency analyses from all-atom molecular dynamics (MD) simulations advance the understanding of reaction mechanisms available from density functional theory (DFT) calculations to an extractable feature scale that can fit the parametric design of supported metal catalytic systems and feed into high throughput catalyst selection. Data on residence time, site-specific adsorption, binding energies, packing geometries, orientation profiles, and the effect of adsorbate size show the anomalous behaviour of organic contaminant adsorption on the undercoordinated {110} surface as compared to the {111} and {100} surfaces. The intermolecular interaction within contaminants from molecular dynamics simulation exhibits refreshing results than ordinary single molecule density functional theory calculation. Since complete adsorption and dechlorination is an essential step for chlorinated organic contaminant remediation pathways, the presented profiles provide essential information for designing efficient remediation systems through facet-controlled palladium nanoparticles.

Guo, Hao↗

Automated identification of local contamination in remote atmospheric composition time series

Abstract. Atmospheric observations in remote locations offer a possibility of exploring trace gas and particle concentrations in pristine environments. However, data from remote areas are often contaminated by pollution from local sources. Detecting this contamination is thus a central and frequently encountered issue. Consequently, many different methods exist today to identify local contamination in atmospheric composition measurement time series, but no single method has been widely accepted. In this study, we present a new method to identify primary pollution in remote atmospheric datasets, e.g., from ship campaigns or stations with a low background signal compared to the contaminated signal. The pollution detection algorithm (PDA) identifies and flags periods of polluted data in five steps. The first and most important step identifies polluted periods based on the derivative (time derivative) of a concentration over time. If this derivative exceeds a given threshold, data are flagged as polluted. Further pollution identification steps are a simple concentration threshold filter, a neighboring points filter (optional), a median, and a sparse data filter (optional). The PDA only relies on the target dataset itself and is independent of ancillary datasets such as meteorological variables. All parameters of each step are adjustable so that the PDA can be “tuned” to be more or less stringent (e.g., flag more or fewer data points as contaminated). The PDA was developed and tested with a particle number concentration dataset collected during the Multidisciplinary drifting Observatory for the Study of Arctic Climate (MOSAiC) expedition in the central Arctic. Using strict settings, we identified 62 % of the data as influenced by local contamination. Using a second independent particle number concentration dataset also collected during MOSAiC, we evaluated the performance of the PDA against the same dataset cleaned by visual inspection. The two methods agreed in 94 % of the cases. Additionally, the PDA was successfully applied to a trace gas dataset (CO2), also collected during MOSAiC, and to another particle number concentration dataset, collected at the high-altitude background station Jungfraujoch, Switzerland. Thus, the PDA proves to be a useful and flexible tool to identify periods affected by local contamination in atmospheric composition datasets without the need for ancillary measurements. It is best applied to data representing primary pollution. The user-friendly and open-access code enables reproducible application to a wide suite of different datasets. It is available at https://doi.org/10.5281/zenodo.5761101 (Beck et al., 2021).

54 ENVIRONMENTAL SCIENCES↗

Innovative Use of Cr(VI) Plume Depictions and Pump-and-Treat Capture Analysis to Estimate Risks of Contaminant Discharge to Surface Water at Hanford Reactor Areas

The Hanford Site nuclear reactor operations required large quantities of high-quality cooling water, which was treated with chemicals including sodium dichromate dihydrate for corrosion control. Cooling water leakage, as well as intentional discharge of cooling water to ground during upset conditions, produced extensive groundwater recharge mounds consisting largely of contaminated cooling water and resulted in wide distribution of hexavalent chromium (Cr[VI]) contamination in the unconfined aquifer. The 2013 Cr(VI) groundwater plumes in the 100 Areas cover approximately 6 km2 (1500 acres), primarily in the 100-HR-3 and 100-KR-4 groundwater operable units (OUs). The Columbia River is a groundwater discharge boundary; where the plumes are adjacent to the Columbia River there remains a potential to discharge Cr(VI) to the river at concentrations above water quality criteria. The pump-and-treat systems along the River Corridor are operating with two main goals: 1) protection of the Columbia River, and 2) recovery of contaminant mass. An evaluation of the effectiveness of the pump-and-treat systems was needed to determine if the Columbia River was protected from contamination, and also to determine where additional system modifications may be needed. In response to this need, a technique for assessing the river protection was developed which takes into consideration seasonal migration of the plume and hydraulic performance of the operating well fields. Groundwater contaminant plume maps are generated across the Hanford Site on an annual basis. The assessment technique overlays the annual plume and the capture efficiency maps for the various pump and treat systems. The river protection analysis technique was prepared for use at the Hanford site and is described in detail in M.J. Tonkin, 2013. Interpolated capture frequency maps, based on mapping dynamic water level observed in observation wells and derived water levels in the vicinity of extraction and injection wells, are developed initially. Second, simulated capture frequency maps are developed, based on transport modelling results. Both interpolated and simulated capture frequency maps are based on operation of the systems over a full year. These two capture maps are then overlaid on the plume distribution maps for inspection of the relative orientation of the contaminant plumes with the capture frequency. To quantify the relative degree of protection of the river from discharges of Cr(VI) (and conversely, the degree of threat) at any particular location, a systematic method of evaluating and mapping the plume/capture relationship was developed. By comparing the spatial relationship between contaminant plumes and hydraulic capture frequency, an index of relative protectiveness is developed and the results posted on the combined plume/capture plan view map. Areas exhibiting lesser degrees of river protection are identified for remedial process optimization actions to control plumes and prevent continuing discharge of Cr(VI) to the river.

Miller, Chuck W.↗

Radioactive Contamination Tenacity on Building Substrate – 17417

Radiological decontamination is an essential enterprise that has become more important over the last four decades due to unfortunate accidents and the threat of terrorist actions. Decontamination can be an effective, beneficial alternative for the cleanup of radiological contamination events; however, the costs and benefits need to be balanced against those for complete removal and demolition of contaminated areas or facilities. Demolition and removal are often the first options considered in such circumstances as decontamination may be thought of as slow and costly. Decontamination has advantages, including significant waste reduction over demolition. In areas with buildings of cultural or societal importance, demolition may not be an option. Three decontamination evaluation test series are the focus of this article: SIMCON 1 and 2 (i.e., simulated contamination), and Urban RDD (radiological dispersal device, i.e., a dirty bomb detonation). These test series revealed that different contaminants respond differently during decontamination. This was found to be true with both SIMCON and Urban RDD simulant tests. SIMCON 2 especially demonstrated that chemically different contaminants respond differently to different decontamination methods: cesium appears to be less tenacious (more easily removed) than zirconium using chemical methods. These differences were underscored by the Urban RDD tests where americium and cobalt tended to precipitate on high pH surfaces (such as concrete), making them easier to remove, while cesium and strontium were essentially unaffected by surface pH and were imbibed more strongly into the substrate pore structure. While authorities argue over the contributions of contaminant chemistry and substrate morphology, the clear answer is that each has a contribution to the tenacity of a contaminant. Knowing how these characteristics interact will make us better at decontamination in the field. This knowledge refutes the efforts of perhaps well-meaning marketers to define our decontamination problems by what products they are trying to sell; often a “one size fits all” type approach. Knowing even a little bit about the character of the decontamination problem will save time and money and increase the efficacy of decontamination.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Method and system for gas flow mitigation of molecular contamination of optics

A computer-implemented method for determining an optimized purge gas flow in a semi-conductor inspection metrology or lithography apparatus, comprising receiving a permissible contaminant mole fraction, a contaminant outgassing flow rate associated with a contaminant, a contaminant mass diffusivity, an outgassing surface length, a pressure, a temperature, a channel height, and a molecular weight of a purge gas, calculating a flow factor based on the permissible contaminant mole fraction, the contaminant outgassing flow rate, the channel height, and the outgassing surface length, comparing the flow factor to a predefined maximum flow factor value, calculating a minimum purge gas velocity and a purge gas mass flow rate from the flow factor, the contaminant mass diffusivity, the pressure, the temperature, and the molecular weight of the purge gas, and introducing the purge gas into the semi-conductor inspection metrology or lithography apparatus with the minimum purge gas velocity and the purge gas flow rate.

42 ENGINEERING↗

Impacts to Project from {sup 99}Tc Contamination on the K-25 / K-27 Decontamination and Decommissioning Project

Like so many good ideas that evolved as the U.S. was learning about nuclear materials, the introduction of recovered uranium from the fuel reprocessing efforts is causing additional headaches in the decontamination and decommissioning (D and D) of the gaseous diffusion plants at the East Tennessee Technology Park in Oak Ridge, Tennessee. Technetium-99 ({sup 99}Tc) is a low-energy beta emitter that is a product of the fission reaction. Its introduction into the in an operating gaseous diffusion plant is of little or no operational or dose concern but creates many issues when planning and conducting the D and D of those facilities. These issues include control of contamination and beta exposure to workers and significant waste management issues when trying to ship and dispose of the waste materials. Technetium-99 is very long lived and mobile in the environment and is therefore has very restrictive concentration limits in wastes going to disposal facilities. The gaseous diffusion process was developed for isotopic enrichment of uranium. Gaseous uranium hexafluoride (UF{sub 6}) was passed through a series of stages to affect the separation of the fissionable U-235 from U-238. Because of the low concentration of U-235 in naturally occurring uranium ({approx}0.711%), the number of separation stages required to enrich the uranium to a level usable for reactor fuels or nuclear weapons was quite large. For instance, the K-25 Building, where uranium was enriched, is a U-shaped structure approximately one mile in length. Similar sizes of stages were grouped in cells, and up to 14 cells were contained in a single building unit. Multiple building units were arranged in series to process the uranium, with the capability of isolation and bypass of each cell. This arrangement of multiple stages was referred to as the cascades. Since UF{sub 6} is a heavy molecule, lighter gases that were contained in the process gas stream moved at a higher rate than UF{sub 6}. These gases tended to quickly flow to the latter stages of the cascade (also known as the 'top of the cascade'). The removal of certain undesired lighter gases was done in the purge cascades. Technetium forms volatile fluoride compounds under the conditions used to chemically convert uranium oxide (UO{sub 2}) in reactor tails to UF{sub 6}. Thus, Tc vaporized and flowed with the process gas in the cascade. However, because Tc is much lighter than U, it rapidly migrated to the top of the cascade and into the purge cascades. Most of the Tc is thought to be located in the purge cascade equipment. The purge cascade equipment is generally located in Area 1 of K-25 and Areas 7 and 8 in K-27. Fourteen building units are now known or believed to be contaminated with {sup 99}Tc. During the demolition activities, the equipment used is expected to become contaminated. To prevent cross-contamination of other wastes with {sup 99}Tc, separate equipment will be used for the southern end of the K-25 east wing. This same demolition equipment will be employed in K-27 to help minimize equipment decontamination efforts at the end of the project. However, because of this sequential schedule, any delays for demolition of the K-25 Building will adversely impact the schedule for K-27. The {sup 99}Tc contamination of the K-25 and K-27 D and D Project is now better known, but considerable planning will still be needed to control migration of this material to meet radiological controls and waste management limits. Since {sup 99}Tc has been an emerging issue over the last decade, the measurement, controls, and ultimately the impacts (e.g., cost and schedule) to the project have caused a significant increase in the planning effort for the D and D of these facilities and are expected to increase the ultimate cost of remediation. The cost increase will not be known until the planning effort is restarted (probably in FY 08-09). The contamination controls to be put in place to minimize the spread of this contaminant are not expected to be fully demonstrated until the demolition of the affected areas later in the project.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High Angle Remediation Antimony, Mercury, and Pu-239/240 Contaminated Soil at LANL near Los Alamos Town Site - 18579

The Manhattan Project and early Cold War era operations at Los Alamos National Laboratory (LANL) left behind soil contaminated with antimony, mercury, and Pu-239/240. TerranearPMC (TPMC) successfully completed a phased three-year high-angle legacy cleanup project to excavate contaminated soil from a steep, difficult-to-access canyon wall in the Upper Los Alamos Canyon Aggregate Area bordering Los Alamos town site. The first and third phases of the project (years 2015 and 2017) utilized a Menzi Muck (spider excavator) in concert with a 275 US ton telescoping crane to remove ∼158 cubic yards (cy) of mercury-contaminated rock and soil (i.e. media) from one solid waste management unit (SWMU) in 2015; and ∼70 cy of antimony contaminated media, and ∼65 cy of collocated mercury and Pu-239/240 contaminated media from two SWMUs in 2017. All soil excavated from the site was containerized in soft-sided 1.0 cy, 1.77 cy, and 3.5 cy IP-1 containers and shipped to an approved, licensed, off-site disposal facility. The crane was also used to move the spider excavator, field personnel, tools, the packaged waste, and restoration materials into and out of the canyon. In 2016, conventional but miniaturized excavation equipment was used to remove about 133 cy of Pu-239/240 contaminated media from four SWMUs west of both the 2015 and 2017 excavations. A total of 398 soil screening, waste composite, characterization/bounding, and confirmation samples were collected during the project. Media that was left in place after the excavation was sampled to confirm that human health concerns and environmental risk issues had been mitigated. This proven technical approach was the preferred method for cleaning up ∼426 cy of contaminated media from steep, difficult-to-access legacy waste sites within the Upper Los Alamos Canyon Aggregate Area between 2015 and 2017. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Kinetics of Cd Release from Some Contaminated Calcareous Soils

Contamination of soils with heavy metals may pose long-term risk to groundwater quality leading to health implications. Bioavailability of heavy metals, like cadmium (Cd) is strongly affected by sorption and desorption processes. The release of heavy metals from contaminated soils is a major contamination risks to natural waters. The release of Cd from contaminated soils is strongly influenced by its mobility and bioavailability. In this study, the kinetics of Cd desorption from ten samples of contaminated calcareous soils, with widely varying physicochemical properties, were studied using 0.01 M EDTA extraction. The median percentage of Cd released was about 27.7% of the total extractable Cd in the soils. The release of Cd was characterized by an initial fast release rate (of labile fractions) followed by a slower release rate (of less labile fractions) and a model of two first-order reactions adequately describes the observed release of Cd from the studied soil samples. There was positive correlation between the amount of Cd released at first phase of release and Cd in exchangeable fraction, indicating that this fraction of Cd is the main fraction controlling the Cd in the kinetic experiments. There was strongly negative correlation between the amount of Cd released at first and second phases of release and residual fraction, suggesting that this fraction did not contribute in Cd release in the kinetic experiments. The results can be used to provide information for evaluation of Cd potential toxicity and ecological risk from contaminated calcareous soils.

54 ENVIRONMENTAL SCIENCES↗

A hybrid phytoremediation system for contaminants in groundwater

Impacted groundwater at hazardous waste release sites often contain mixtures of contaminants. It can be relatively easy to treat some compounds ex situ. However, mixtures of some compounds can be difficult to treat. A method to extract and treat complex mixtures of contaminants of concern using phytotechnology is proposed in this paper. A specific case study is described wherein a hybrid phytoremediation system is compared and contrasted with conventional groundwater and phytoremediation technologies. Nitrate is used as an exemplar co-contaminant since nitrate contamination is (1) widespread in the United States, and (2) difficult and expensive to treat. The approach involves using contaminated groundwater as a source of irrigation water for a phytoremediation grove. Groundwater would be extracted using conventional groundwater extraction methods. Groundwater then would be pumped to multiple irrigation zones under the control of an autonomous irrigation system. Each zone would consist of a number of trees. The root system for each tree would be modified to function as a confined treatment cell that facilitates contaminated water uptake. The irrigation controller would optimize the amount of groundwater that can be extracted and treated while preventing surface water runoff away from the phyto component.

54 ENVIRONMENTAL SCIENCES↗

Chromium transport in an acidic waste contaminated subsurface medium: The role of reduction

A series of wet chemical extractions and column experiments, combined with electron microprobe analysis (EMPA) and X-ray photoelectron spectroscopy (XPS) measurements, were conducted to estimate the extent of contaminant Cr(VI) desorption and determine the mechanism(s) of Cr(VI) attenuation in contaminated and naturally aged (decades) Hanford sediments which were exposed to dichromate and acidic waste solutions. Results from wet extractions demonstrated that contaminated sediments contained a large fraction of tightly-bound Cr. Results from column experiments showed that effluent Cr(VI) concentrations were low and only a small percentage of the total Cr inventory was released from the contaminated sediments, demonstrating again low Cr mobility. EMPA inspections showed that Cr contamination was spread throughout sediment matrix and high-concentrated Cr spots were not apparently present. XPS analyses showed that most surface Cr was Cr(III). Reduced Cr(III) was spatially associated with Fe, which occurred mostly as Fe(III). Neoprecipitates were most likely Cr(III) oxyhydroxides or [Cr(III) Fe(III)] solid solutions. Extensive reduction to Cr(III) limited dramatically mass flux from this source. The following multiple-step mechanism was most likely operational in the contaminated sediments: acid promoted dissolution of Fe(II)-bearing soil minerals and/or their surface coatings, release of Fe(II) in the aqueous phase, abiotic homogeneous and/or heterogeneous Cr(VI) reduction by aqueous, sorbed and/or structural Fe(II), formation of insoluble Cr(III) phases or [Cr(III) Fe(III)] solid solutions.

54 ENVIRONMENTAL SCIENCES↗

Application of an in-situ soil sampler for assessing subsurface biogeochemical dynamics in a diesel-contaminated coastal site during soil flushing operations

Subsurface biogeochemistry and contaminant dynamics during the remediation of diesel-contamination by in-situ soil flushing were investigated at a site located in a coastal region. An in-situ sampler containing diesel-contaminated soils separated into two size fractions (<0.063- and <2-mm) was utilized in two monitoring wells: DH1 (located close to the injection and extraction wells for in-situ soil flushing) and DH2 (located beyond sheet piles placed to block the transport of leaked diesel). Total petroleum hydrocarbon (TPH) concentrations and biogeochemical properties were monitored both in soil and groundwater for six months. A shift occurred in the groundwater type from Ca-HCO 3 to Na-CI due to seawater intrusion during intense pumping, while the concentrations of Ni, Cu, Co, V, Cr, and Se increased substantially following surfactant (TWEEN 80) injection. The in-situ sampler with fine particles was more sensitive to variations in conditions during the remedial soil flushing process. In both wells, soil TPH concentrations in the <0.063-mm fraction were much higher than those in the <2-mm fraction. Increases in soil TPH in DH1 were consistent with the expected outcomes following well pumping and surfactant injection used to enhance TPH extraction. However, the number of diesel-degrading microorganisms decreased after surfactant injection. 16S-rRNA gene-based analysis also showed that the community composition and diversity depended on both particle size and diesel contamination. The multidisciplinary approach to the contaminated site assessments showed that soil flushing with surfactant enhanced diesel extraction, but negatively impacted in-situ diesel biodegradation as well as groundwater quality. In conclusion, the results also suggest that the in-situ sampler can be an effective monitoring tool for subsurface biogeochemistry as well as contaminant dynamics.

02 PETROLEUM↗