Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CONES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Study of double vector charmonium meson production at B factories within light cone formalism

In this paper the processes e{sup +}e{sup -}{yields}J/{psi}J/{psi}, J/{psi}{psi}{sup '}, {psi}{sup '}{psi}{sup '} are considered in the framework of light cone formalism. An important distinction of this approach in comparison to the approaches used in other papers is that relativistic and leading logarithmic radiative corrections to the cross section can be resummed within light cone formalism. In this paper, the effect of this resummation is studied. It is shown that this effect is important, especially for the production of higher charmonium mesons. The predicted cross sections are in agreement with the upper bounds set by the Belle Collaboration.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Zero momentum modes in discrete light-cone quantization

We consider the constrained zero modes found in the application of discrete light-cone quantization to the nonperturbative solution of quantum field theories. These modes are usually neglected for simplicity, but we show that their inclusion can be relatively straightforward, and, what is more, that they are useful for nonperturbative calculations of field-theoretic spectra. In particular, inclusion of zero modes improves the convergence of the numerical calculation and makes possible the direct calculation of vacuum expectation values, even when the zero modes are determined dynamically. We also comment on zero-mode contributions not included by discrete light-cone quantization, namely, zero-mode loops.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Light-cone distribution amplitudes of {xi} and their applications

We present the light-cone distribution amplitudes of the {xi} baryons up to twist six on the basis of QCD conformal partial wave expansion to the leading order conformal spin accuracy. The nonperturbative parameters relevant to the DAs are determined in the framework of the QCD sum rule. The light-cone QCD sum rule approach is used to investigate both the electromagnetic form factors of {xi} and the exclusive semileptonic decay of {xi}{sub c} as applications. Our estimations on the magnetic moments are {mu}{sub {xi}{sup 0}}=-(1.92{+-}0.34){mu}{sub N} and {mu}{sub {xi}{sup -}}=-(1.19{+-}0.03){mu}{sub N}. The decay width of the process {xi}{sub c}{yields}{xi}e{sup +}{nu}{sub e} is evaluated to be {gamma}=8.73x10{sup -14} GeV, which is in accordance with the experimental measurements and other theoretical approaches.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

{lambda}{sub b}{yields}p, {lambda} transition form factors from QCD light-cone sum rules

Light-cone sum rules for the {lambda}{sub b}{yields}p, {lambda} transition form factors are derived from the correlation functions expanded by the twist of the distribution amplitudes of the {lambda}{sub b} baryon. In terms of the {lambda}{sub b} three-quark distribution amplitude models constrained by the QCD theory, we calculate the form factors at small momentum transfers and compare the results with those estimated in the conventional light-cone sum rules (LCSR) and perturbative QCD approaches. Our results indicate that the two different versions of sum rules can lead to the consistent numbers of form factors responsible for {lambda}{sub b}{yields}p transition. The {lambda}{sub b}{yields}{lambda} transition form factors from LCSR with the asymptotic {lambda} baryon distribution amplitudes are found to be almost 1 order larger than those obtained in the {lambda}{sub b}-baryon LCSR, implying that the preasymptotic corrections to the baryonic distribution amplitudes are of great importance. Moreover, the SU(3) symmetry breaking effects between the form factors f{sub 1}{sup {lambda}{sub b}}{sup {yields}}{sup p} and f{sub 1}{sup {lambda}{sub b}}{sup {yields}}{sup {lambda}} are computed as 28{sub -8}{sup +14}% in the framework of {lambda}{sub b}-baryon LCSR.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Sivers and Boer-Mulders functions in Light-Cone Quark Models

Results for the naive-time-reversal-odd quark distributions in a light-cone quark model are presented. The final-state interaction effects are generated via single-gluon exchange mechanism. The formalism of light-cone wave functions is used to derive general expressions in terms of overlap of wave-function amplitudes describing the different orbital angular momentum components of the nucleon. In particular, the model predictions show a dominant contribution from S- and P-wave interference in the Sivers function and a significant contribution also from the interference of P and D waves in the Boer-Mulders function. The favourable comparison with existing phenomenological parametrizations motivates further applications to describe azimuthal asymmetries in hadronic reactions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Analyses of decay constants and light-cone distribution amplitudes for s-wave heavy meson

In this paper, a study of light-cone distribution amplitudes (LCDAs) for s-wave heavy meson are presented in both general and heavy quark frameworks. Within the light-front approach, the leading twist light-cone distribution amplitudes, {phi}{sub M}(u), and their relevant decay constants of heavy pseudoscalar and vector mesons, f{sub M}, have simple relations. These relations can be further simplified when the heavy quark limit is taken into consideration. After fixing the parameters that appear in both Gaussian and power-law wave functions, the corresponding decay constants are calculated and compared with those of other theoretical approaches. The curves and the first six {xi}-moments of {phi}{sub M}(u) are plotted and estimated. A conclusion is drawn from these results: Even though the values of the decay constants of the distinct mesons are almost equal, the curves of their LCDAs may have quite large differences, and vice versa. Additionally, in the heavy quark limit, the leading twist LCDAs, {Phi}{sub Qq}({omega}) and {Phi}{sub Qq}({omega}), are compared with the B-meson LCDAs, {psi}{sub +}({omega}), suggested by the other theoretical groups.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Two-parton light-cone distribution amplitudes of tensor mesons

We present a detailed study of the two-parton light-cone distribution amplitudes for 1{sup 3}P{sub 2} nonet tensor mesons. The asymptotic two-parton distribution amplitudes of twist-2 and twist-3 are given. The decay constants f{sub T} and f{sub T}{sup (perpendicular{sup sign})} defined by the matrices of nonlocal operators on the light-cone are estimated using the QCD sum rule techniques. We also study the decay constants for f{sub 2}(1270) and f{sub 2}{sup '}(1525) based on the hypothesis of tensor meson dominance together with the data of {Gamma}(f{sub 2}{yields}{pi}{pi}) and {Gamma}(f{sub 2}{sup '}{yields}KK) and find that the results are in accordance with the sum rule predictions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Exclusive C=+ charmonium production in e{sup +}e{sup -{yields}}H+{gamma} at B factories within the light cone formalism

In this paper the cross sections of the processes e{sup +}e{sup -{yields}}H+{gamma}, H={eta}{sub c}, {eta}{sub c}{sup '}, {chi}{sub c0}, {chi}{sub c1}, {chi}{sub c2} are calculated. The calculation is carried out at the leading twist approximation of the light cone formalism. Within this approach the leading logarithmic radiative and relativistic corrections to the amplitudes are resummed. For the processes e{sup +}e{sup -{yields}{eta}}{sub c}, {eta}{sub c}{sup '}+{gamma} one-loop radiative corrections are taken into account. It is also shown that one-loop leading logarithmic radiative corrections calculated within the light cone formalism for the processes under study coincide with that obtained by direct calculations of one-loop diagrams within nonrelativistic QCD.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

B{sub (s)}{yields}S transitions in the light cone sum rules with the chiral current

We make a QCD light-cone sum rule assessment of B{sub (s)} semileptonic decays to a light scalar meson, B{sub (s)}{yields}Sl{nu}{sub l}, Sll(l=e,{mu},{tau}). Chiral current correlators are used and calculations are performed at leading order in {alpha}{sub s}. Having little knowledge of the ingredients of the scalar mesons, we confine ourself to the two-quark picture for them and work with the two possible scenarios. The resulting sum rules for the form factors receive no contributions from the twist-3 distribution amplitudes, in comparison with the calculation of the conventional light-cone sum rule approach where the twist-3 parts usually play an important role. We specify the range of the squared momentum transfer q{sup 2}, in which the operator product expansion for the correlators remains valid approximately. It is found that the form factors satisfy a relation consistent with the prediction of soft collinear effective theory. In the effective range we investigate behaviors of the form factors and differential decay widths and compare our calculations with the observations from other approaches.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-E-J-43: Deformed Planning CT as An Electron Density Substitute for Cone-Beam CT

Purpose: To confirm that deforming the planning CT to the daily Cone-Beam CTs (CBCT) can provide suitable electron density for adaptive planning. We quantify the dosimetric difference between plans calculated on deformed planning CTs (DPCT) and daily CT-on-rails images (CTOR). CTOR is used as a test of the method as CTOR already contains accurate electron density to compare against. Methods: Five prostate only IMRT patients, each with five CTOR images, were selected and re-planned on Panther (Prowess Inc.) with a uniform 5 mm PTV expansion, prescribed 78 Gy. The planning CT was deformed to match each CTOR using ABAS (Elekta Inc.). Contours were drawn on the CTOR, and copied to the DPCT. The original treatment plan was copied to both the CTOR and DPCT, keeping the center of the prostate as the isocenter. The plans were then calculated using the collapsed cone heterogeneous dose engine of Prowess and typical DVH planning parameters used to compare them. Results: Each DPCT was visually compared to its CTOR with no differences observed. The agreement of the copied CTOR contours with the DPCT anatomy further demonstrated the deformation accuracy. The plans calculated using CTOR and DPCT were compared. Over the 25 plan pairs, the average difference between them for prostate D100, D98 and D95 were 0.5%, 0.2%, and 0.2%; PTV D98, D95 and mean dose: 0.3%, 0.2% and 0.3%; bladder V70, V60 and mean dose: 1.1%, 0.7%, and 0.2%; and rectum mean dose: 0.3%. (D100 is the dose covering 100% of the target; V70 is the volume of the organ receiving 70 Gy). Conclusion: We observe negligible difference between the dose calculated on the DPCT and the CTOR, implying that deformed planning CTs are a suitable substitute for electron density. The method can now be applied to CBCTs. Research version of Panther provided by Prowess Inc. Research version of ABAS provided by Elekta Inc.

60 APPLIED LIFE SCIENCES↗

SU-E-T-143: Effect of X-Ray and Cone Beam CT Reconstruction Parameters On Estimation of Bone Volume of Mice Used in Aging Research

Purpose: To investigate the variations in bone volume calculations in mice involved in aging research when changing cone beam micro-CT x-ray and reconstruction parameters. Methods: Mouse spines were placed on an indexed turn table that rotated 0.5° per projection and imaged by a self-built micro CT machine containing a CCD-based high-resolution x-ray detector. After the full 360° rotation data set of object images was obtained, a standard filtered back-projection cone beam reconstruction was performed. Four different kVp's between 40–70 kVp in 10kVp increments were selected. For each kVp two mAs settings were used. Each acquisition was reconstructed using two voxel sizes (12 and 25μm) and two step angles, 0.5° and 1°, respectively. A LabView program was written to determine the total bone volume contained in the mouse's total spine volume (bone plus gaps) as a measure of spine health. First, the user selected the desired 512×512 reconstruction to view the whole spine volume which was then used to select a gray-level threshold that allowed for viewing of the bone structure, then another threshold to include gaps. The program returned bone volume, bone × gap volume, and their ratio, BVF. Results: The calculated bone volume fractions were compared as a function of tube potential. Cases with 25μm slice thickness showed trials with lower kVp's had greater image contrast, which resulted in higher calculated bone volume fractions. Cases with 12μm reconstructed slice thickness were significantly noisier, and showed no clear maximum BVF. Conclusion: Using the projection images and reconstructions acquired from the micro CT, it can be shown that the micro-CT x-ray and reconstruction parameters significantly affect the total bone volume calculations. When comparing mice cohorts treated with different therapies researchers need to be aware of such details and use volumes which were acquired and processed in identical conditions.

60 APPLIED LIFE SCIENCES↗

Dosimetry of cone-defined stereotactic radiosurgery fields with a commercial synthetic diamond detector

Purpose: Small field x-ray beam dosimetry is difficult due to lack of lateral electronic equilibrium, source occlusion, high dose gradients, and detector volume averaging. Currently, there is no single definitive detector recommended for small field dosimetry. The objective of this work was to evaluate the performance of a new commercial synthetic diamond detector, namely, the PTW 60019 microDiamond, for the dosimetry of small x-ray fields as used in stereotactic radiosurgery (SRS). Methods: Small field sizes were defined by BrainLAB circular cones (4–30 mm diameter) on a Novalis Trilogy linear accelerator and using the 6 MV SRS x-ray beam mode for all measurements. Percentage depth doses (PDDs) were measured and compared to an IBA SFD and a PTW 60012 E diode. Cross profiles were measured and compared to an IBA SFD diode. Field factors, Ω{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}}, were calculated by Monte Carlo methods using BEAMnrc and correction factors, k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}}, were derived for the PTW 60019 microDiamond detector. Results: For the small fields of 4–30 mm diameter, there were dose differences in the PDDs of up to 1.5% when compared to an IBA SFD and PTW 60012 E diode detector. For the cross profile measurements the penumbra values varied, depending upon the orientation of the detector. The field factors, Ω{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}}, were calculated for these field diameters at a depth of 1.4 cm in water and they were within 2.7% of published values for a similar linear accelerator. The corrections factors, k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}}, were derived for the PTW 60019 microDiamond detector. Conclusions: The authors conclude that the new PTW 60019 microDiamond detector is generally suitable for relative dosimetry in small 6 MV SRS beams for a Novalis Trilogy linear equipped with circular cones.

07 ISOTOPE AND RADIATION SOURCES↗

SU-G-JeP1-01: A Combination of Real Time Electromagnetic Localization and Tracking with Cone Beam Computed Tomography in Stereotactic Radiosurgery for Brain Tumors

Purpose: 1. online verification of patient position during treatment using calypso electromagnetic localization and tracking system. 2. Verification and comparison of positional accuracy between cone beam computed tomography and calypso system. 3. Presenting the advantage of continuation localization in Stereotactic radiosurgery treatments. Methods: Ten brain tumor cases were taken for this study. Patients with head mask were under gone Computed Tomography (CT). Before scanning, mask was cut on the fore head area to keep surface beacons on the skin. Slice thickness of 0.65 mm were taken for this study. x, y, z coordinates of these beacons in TPS were entered into tracking station. Varian True Beam accelerator, equipped with On Board Imager was used to take Cone beam Computed Tomography (CBCT) to localize the patient. Simultaneously Surface beacons were used to localize and track the patient throughout the treatment. The localization values were compared in both systems. For localization CBCT considered as reference. Tracking was done throughout the treatment using Calypso tracking system using electromagnetic array. This array was in tracking position during imaging and treatment. Flattening Filter free beams of 6MV photons along with Volumetric Modulated Arc Therapy was used for the treatment. The patient movement was observed throughout the treatment ranging from 2 min to 4 min. Results: The average variation observed between calypso system and CBCT localization was less than 0.5 mm. These variations were due to manual errors while keeping beacon on the patient. Less than 0.05 cm intra-fraction motion was observed throughout the treatment with the help of continuous tracking. Conclusion: Calypso target localization system is one of the finest tools to perform radiosurgery in combination with CBCT. This non radiographic method of tracking is a real beneficial method to treat patients confidently while observing real-time motion information of the patient.

60 APPLIED LIFE SCIENCES↗

Relativistic nuclear corrections to the spin structure function of the deuteron in the light-cone variables

The relativistic deuteron has been considered in the light-cone formalism as a system of two strongly interacting nucleons (two-nucleon approximation). The technique for the calculation of the average helicity of the proton in the deuteron has been considered in the light-cone variables. A receipt has been pro-posed for the consistent calculation of relativistic nuclear corrections to the average helicity of the proton in the deuteron and to the spin structure function of the deuteron g{sub 1}{sup D}. Relativistic-correction-induced change in the Bjorken sum rule has been discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Configuration of singular optical cones in gyrotropic crystals with dichroism

Optical conic singularities in crystals with linear dichroism and natural optical activity at the point of intersection of dispersion curves for the main refractive indices are considered. The possible existence of singularities like a nodal point, tangency point, triple point, and cusps of the first and second order is demonstrated. Forty-nine different types of irreducible fourth-order optical cones obtained by sequential bifurcations of eight main singular cones are established. The classification is based on the concept of roughness of systems depending on parameters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cone Penetrometer N Factor Determination Testing Results

This document contains the results of testing activities to determine the empirical 'N Factor' for the cone penetrometer in kaolin clay simulant. The N Factor is used to relate resistance measurements taken with the cone penetrometer to shear strength.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fast ignition relevant study of the flux of high intensity laser-generated electrons via a hollow cone into a laser-imploded plasma

An integrated experiment relevant to fast ignition. A Cu-doped deuterated polymer spherical shell target with an inserted hollow Au cone is imploded by a six-beam 900-J, 1-ns laser. A 10-ps, 70-J laser pulse is focused into the cone at the time of peak compression. The flux of high-energy electrons through the imploded material is determined from the yield of Cu K{sub {alpha}} fluorescence by comparison with a Monte Carlo model. The electrons are estimated to carry about 15% of the laser energy. Collisional and Ohmic heating are modeled, and Ohmic effects are shown to be relatively unimportant. An electron spectrometer shows significantly greater reduction of the transmitted electron flux than is calculated in the model. Enhanced scattering by instability-induced magnetic fields is suggested. An extension of this fluor-based technique to measurement of coupling efficiency to the ignition hot spot in future larger-scale fast ignition experiments is outlined.

42 ENGINEERING↗

Modification of the loss cone for energetic particles

Abstract The optimal pitch angle which maximizes the penetration distance, along the magnetic field, of relativistic charged particles injected from the midplane of an axisymmetric field is investigated analytically and numerically. Higher‐order terms of the magnetic moment invariant are necessary to correctly determine the mirror point of trapped energetic particles, and therefore the loss cone. The modified loss cone resulting from the inclusion of higher‐order terms is no longer entirely defined by the pitch angle but also by the phase angle of the particle at the point of injection. The optimal orientation of the injection has a nonzero component perpendicular to the magnetic field line, and is in the plane tangential to the flux surface. Numerical integration of particle orbits were carried out for a relativistic electron in a dipole field, showing agreement with analytic expressions. The results are relevant to experiments, which are concerned with injection of relativistic beams into the atmosphere from aboard a spacecraft in the magnetosphere.

Porazik, Peter↗