Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COMPRESSION STRENGTH”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Framework for Characterizing the Performance of High-Early Strength, High-Volume Fly Ash (HVFA) Concrete Structures

This presentation will highlight the development of a comprehensive framework to characterize the performance of high-volume fly ash (HVFA) concretes at early ages and discuss the resulting implications for concrete structures built using such materials. Achieving high-early compressive and/or flexural strength is often of particular importance for precast and/or prestressed concrete components – due to early age loading demands resulting from lifting, handling, or application of initial prestress – or other types of concrete structures that can significantly benefit from rapid strength development - such as for bridge deck repairs. The framework first includes a methodology for optimizing the strength of HVFA cementitious binders before subsequently scaling up the technology to evaluation of fresh and hardened HVFA concrete performance. A series of trial mix designs will be presented to demonstrate the effectiveness of the framework to achieve not only the desired high-early strength targets but also satisfactory workability, often in the form of self-consolidating concrete. Mechanical performance was evaluated at several age-dependent milestones and, in conjunction with estimating concrete strength using the maturity method, was ultimately used to facilitate the development of novel strength development history curves. By way of these datasets, concrete mechanical properties were utilized in the design of prototype structural components, such as beams and wall panels, for subjection to larger-scale experimental testing. Implications for other pertinent HVFA concrete performance attributes, such as shrinkage or creep, will also be discussed. The framework also includes a comprehensive methodology for evaluating the environmental life-cycle performance of HVFA concrete structures focused on mitigating any unwarranted environmental consequences resulting from beneficial HVFA reuse in concrete. Strategies for more widespread implementation of HVFA concrete materials into construction practice will also be presented. Lastly, the role of the HVFA concrete framework towards the development of new provisions for building codes and/or design standards, and recommendations for future research needs will also be discussed.

01 COAL, LIGNITE, AND PEAT↗

Measurement of the strengths of Be and Pb4Sb by quasi-isentropic compress and release at near 100 GPa

The Ramp-compression experiments have been performed on the “Z” pulsed-power facility to investigate the strengths of Be and lead-antimony alloy. Yield strength and shear stress near peak pressure were obtained from measurements of the sound speed on release and using the Asay self-consistent method. Two S-65 grade Be samples, from batches which showed a significant difference in yield strength at ambient conditions, were found to have near identical yield strengths, which were also in agreement with similar earlier measurements on S-200 grade Be. Yield strength of Pb4Sb alloy at ~120 GPa was 1.35 GPa, while a National Ignition Facility (NIF) experiment by A. Krygier et al. (Phys. Rev. Lett. 123, 205701 (2020)) found 3.8 GPa at ~400 GPa pressure. Our result is intermediate between the ambient value and the Krygier one, but the significantly increased strength is probably not associated with the transition to the high-pressure bcc phase of lead.

42 ENGINEERING↗

High resolution >40 keV x-ray radiography using an edge-on micro-flag backlighter at NIF-ARC

Radiography of low-contrast features in high-density materials evolving on a nanosecond timescale requires a bright photon source in the tens of keV range with high temporal and spatial resolution. One application for sources in this category is the study of dynamic material strength in samples compressed to Mbar pressures at the National Ignition Facility, high-resolution measurements of plastic deformation under conditions relevant to meteor impacts, geophysics, armor development, and inertial confinement fusion. Here, we present radiographic data and the modulation transfer function (MTF) analysis of a multi-component test object probed at ~100 keV effective backlighter energy using a 5 μm-thin dysprosium foil driven by the NIF Advanced Radiographic Capability (ARC) short-pulse laser (~2 kJ, 10 ps). The thin edge of the foil acts as a bright line-projection source of hard x rays, which images the test object at 13.2× magnification into a filtered and shielded image plate detector stack. The system demonstrates a superior contrast of shallow (5 μm amplitude) sinusoidal ripples on gold samples up to 90 μm thick as well as enhanced spatial and temporal resolution using only a small fraction of the laser energy compared to an existing long-pulse-driven backlighter used routinely at the NIF for dynamic strength experiments.

47 OTHER INSTRUMENTATION↗

From broadband biphotons to frequency combs via spectral compression with time-varying cavities

Biphoton frequency combs are promising resources for quantum networking due in large part to their compatibility with the telecommunication infrastructure. Here, in this work, we propose a method to periodically compress broadband frequency-entangled photons into biphoton frequency combs by utilizing time-varying linear cavities. Our approach hinges on rapid modulation of the input cavity coupling, yielding high spectral purity in each output comb line similar to that achieved with narrowband filters, but without the associated loss in flux. We examine the dependence of spectral purity and compression on coupling strength, cavity loss, and switching speed, finding realistic regimes supporting purities in excess of 0.999 and peak enhancement factors of 100× and beyond.

Myilswamy, Karthik V. [Purdue Univ., West Lafayett↗

Advancement of Commercial Intumescent Expanding Foams for Deactivation and Decommissioning in the Nuclear Sector - 20198

Florida International University (FIU), in collaboration with The Department of Energy's Office of Environmental Management (DOE-EM), Savannah River National Laboratory (SRNL), and sites across the Savannah River complex, have identified an operational requirement for a fixative technology that is intended to immobilize and/or isolate residual contamination within a 3-dimensional space. Fixation of radiological contamination can reduce worker risk and mitigate potentially hazardous conditions, however nearly every marketed contamination fixative has been found to be flammable; a significant concern in radiological facilities. Coupled with this, industry fixatives are normally used as a thin coating which can present problems when attempting to stabilize irregular geometry or areas that are difficult to access whilst ensuring full coverage. The technical evaluation and advancement of commercial-off-the-shelf (COTS) polyurethane foams has yielded a down-selected candidate that shows potential in meeting the requirements to support deactivation and decommissioning activities. Several performance criteria have been established and tested to progress the technology readiness level towards an active field demonstration (TRL-7). Such criteria include: mechanical failure limits, adhesive and cohesive properties, thermal/fire resilience, determining thermal behavior, ability to immobilize contamination, and a means of non-destructive evaluation of applications. The test scenario examined was targeted towards an application for decommissioning nuclear pipework, in which the down-selected polyurethane foam would act as a barrier to segregate pipework and mitigate the potential for release during cutting, packaging, and storage operations. Testing carried out at SRNL included: mechanical evaluation of tensile, compressive, and adhesion strength by dynamic mechanical analysis (DMA), as well as thermogravimetric analysis (TGA). FIU examined the foam's fixative properties by utilizing phosphorescent europium-dysprosium doped strontium aluminate powder to investigating the extent to which contamination can be immobilized. FIU has also exploited previous successes in the field of intumescent technologies to assess the down-selected foam's tolerance to an extreme fire scenario, while maintaining the ability to effectively mitigate a contamination release. Parallel to this, extensive thermal investigations were carried out to determine the upper boundary of anticipated heat generation during the curing process as heat generation has the potential to compromise rubber parts of contaminated enclosures. These investigations subsequently yielded a promising method for a non-destructive application evaluation by means of infrared thermography. Utilizing the high sensitivity of modern IR cameras, coupled with the heat generated during the curing process of the polyurethane foam, FIU has been exploring the concept of monitoring the external pipe surface for indications of an irregular or abnormal application, thus informing operational decision making. The testing carried out utilized several current 'best fit' ASTM standards, which serve as helpful guidelines for testing, however, a precise definition of the operational parameters and requirements is still necessary. With continued collaboration with SRNL, FIU aims refine said definitions and develop new standards by which this, and other decommissioning technologies, can be accredited by relevant standards based testing. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Inference of strength and phase transition kinetics in dynamically-compressed tin

Dynamic compression experiments in condensed matter are of interest in part because they provide opportunities to examine material response under extreme conditions; however, the inference of material behavior from dynamic experiments is challenging in the presence of phase transitions exhibiting kinetic processes. Demonstrating an approach to quantitative interpretation of such dynamic experiments, here we present a Bayesian model calibration of strength and phase transformation parameters to data drawn from pulsed power and gas gun shot experiments. The posterior predictions of the Bayesian model capture the experimental measurements and account for the various uncertainties in the experimental configurations. This holistic approach to model calibration utilizing multiple types of experimental data identifies important cross correlations among kinetics, strength, and the phase boundary. Improved insight into potential sources of current model form error is provided by comparing the differences between calibrations against different subsets of the experimental data.

42 ENGINEERING↗

Effect of Sample Thickness on the Tensile Strength of Small Graphite Discs

This report formally documents the completion of the Advanced Reactor Technologies (ART) Level 3 Milestone (M3TG-24OR0501054), “Continue activities related to Split Disc-DIC - complete analysis of effect of sample thickness on one fine grain graphite,” due May 31, 2024. Details within this report outline the status of activities aimed at elucidating the effect of sample thickness on the tensile strength measurement using the small-disc, split-disc testing standard in support of the US Department of Energy’s ART Graphite R&D Program. The ASTM D8289, Standard Test Method for Tensile Strength Estimate by Disc Compression of Manufactured Graphite, was developed to provide an alternative means for testing tensile strength on smaller specimens, which are compatible with available irradiation capsule volumes, and other compatibility measurements. ASTM D8289 specifies that acceptable specimen diameter can range from 6 to 12.7 mm and that the maximum allowed sample thickness should be half of the diameter. However, information is limited with respect to the effect of thickness on the measured splitting tensile strength. This report documents efforts to understand the effect of sample thickness on splitting tensile strength. The work involved testing Ø12.7 mm samples of fine-grain graphites 2114 and IG-110 of different thicknesses (6.35, 5, 4, and 3 mm). The digital image correlation (DIC) method was applied to the samples, along with the ASTM D8289 Standard, to help interpret the measured results.

36 MATERIALS SCIENCE↗

Investigation of nonlinear mechanical behavior of two superfine-grained graphites with DIC assisted disc splitting test

Using standardized uniaxial tensile test specimens is not practical due to the limited volumes in irradiation capsules, molten salt degradation facilities, or oxidation apparatus. The ASTM International Standard Test Method for Tensile Strength Estimate by Disc Compression of Manufactured Graphite (ASTM D8289) was developed to provide a convenient way for estimating tensile strength. Unlike the traditional uniaxial tensile test in ASTM C749 (International Standard Test Method for Tensile Stress–Strain of Carbon and Graphite), which uses dog-bone shaped specimens larger than 12.95 mm × 120.65 mm, the ASTM D8289 standard uses smaller discs with diameters of 6–12.7 mm. A digital image correlation (DIC) system, which uses a full-field noncontact surface displacement measurement technique, was applied along with the ASTM D8289 disc splitting test on IG-110 samples and compared with previous measurements from Mersen 2114 samples. Results confirmed that the DIC technique can measure the surface displacement/strain on these small (Ø6 mm × 3 mm) graphite specimens with good repeatability. However, Mersen 2114 and IG-110 samples exhibited strain discrepancies when DIC measurements were compared with analytical and finite element simulation values. The loading history and strain results also indicated different mechanical behaviors between Mersen 2114 and IG-110, particularly the nonlinear behavior of the IG-110 samples. Good agreement was observed by comparing the splitting tensile strengths of two superfine-grained grades with results from other work. The specimen size effect is discussed when comparing the splitting tensile strength with corresponding uniaxial tensile strength of these two graphite grades.

Lin, Lianshan [ORNL] (ORCID:0000000203399219)↗

Elastic moduli of hexagonal diamond and cubic diamond formed under shock compression

The relative stiffnesses and strengths of hexagonal diamond and cubic diamond constitute long standing unresolved issues, because relevant experimental results are lacking. Laser interferometry was used to experimentally determine the longitudinal sound speeds and moduli in hexagonal diamond and cubic diamond formed during the shock compression of graphite. The hexagonal diamond longitudinal moduli are significantly larger than the cubic diamond longitudinal moduli, and even exceed averaged cubic diamond single crystal values. Here, the measured hexagonal diamond longitudinal moduli, combined with high-pressure bulk moduli for cubic diamond single crystals, show that shock-formed hexagonal diamond shear moduli are larger than the shear moduli for cubic diamond single crystals.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Adhesion Capabilities of Permanent Foaming Fixatives

DOE-EM have identified an operational requirement for a fixative that can immobilize and/or encapsulate residual contamination in 3D void volumes (pipes, gloveboxes, waste containers, etc.) during D and D activities. Failure to safely and effectively immobilize residual contamination can: Put workers at risk; Contaminate the public and environment; Drive up costs. Commercial-off-the-shelf (COTS) polyurethane (PU) foams is one possible solution and is currently being investigated by Savannah River National Lab (SRNL). Adhesion testing will dictate how well PU foams will adhere and immobilize residual contamination onto a substrate. Results can provide a performance criteria for Section 5 of ASTM E3191: Standard Specification for Permanent Foaming Fixatives Used to Mitigate Spread of Radioactive Contamination. Initial mechanical testing showed intumescent rigid PU foams were best in class (tensile, compression, TGA/DSC) Application of intumescent rigid PU foam in pipe scenario with 'contamination' showed excellent adhesion capabilities as long as foam had contact with pipe. The foam, however, was not able to penetrate 'contamination' but created pockets where the contamination interacted with the substrate. Pretreatment options of pipe were considered to produce better immobilization capabilities. Pretreatment options included COTS products like baking spray, rubber cement, and soap. Foam was still able to immobilize on a global sense, but not a local sense. Essentially acted as a mechanical plug. A tensile tester (MTS Criterion Series 43) was utilized to evaluate the tensile adhesion strength of 6 COTS PU foams. ASTM D1623: Tensile and Tensile Adhesion Properties of Rigid Cellular Plastics. Procedures: PU foams were cured between two smooth 2'' x 2'' 304 stainless steel coupons with hinges glued on plates for gripping support. Parameters Used: Pull rate of 0.1 in/min. Calculations: Tensile adhesion strength, elongation, and ImageJ analysis of how PU foam is left on substrate. Outcome: The PU foam with the best adhesion capabilities would be downselected for further evaluation to be used as a permanent foaming fixative. The rigid PU foams had the best adhesion capabilities with the R1 foam having a max load of 236 N. One of the I-R2 samples reached almost 450 N and another sample reached 2500 N before slipping. The other intumescent foam, I-F4, had the most coverage on the stainless steel coupon's surface from the ImageJ results (61.43% surface coverage). The intumescent foam, I-R2, will be the foam of choice for future testing due its fire retardant and adhesion capabilities. Future directions: Conduct the following experiment in a pipe scenario with the down-selected PU foam. Procedures: PU foam will be cured between in a 304 stainless steel pipe (ID: 4'', OD: 4.5'', Height: 4''). Parameters Used: Compression testing results will be referenced to determine if foam's adhesion strength would be greater its compression strength as its being compressed. Calculations: Compression strength, shear stress, total time elapsed. Conduct further adhesion testing with the down-selected PU foam (I-R2) to be treated as a permanent foaming fixative (PFF). Determine the minimum contact the PFF should have with the substrate for adequate results. Evaluate if PFF's adhesion capabilities is time dependent (3.1.5 of ASTM E3911). Subject PFF to seismic stressors addressed in Safety Basis of Interim Operation documents (SBIO) to further evaluate adhesion capabilities.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

In situ study on the compression deformation of MoNbTaVW high-entropy alloy

The excellent mechanical properties of high-entropy alloys (HEAs) make them promising materials for advances in science and technology. However, the underlying mechanism of plastic deformation is not well understood. In situ experiments are urgently required to provide a fundamental understanding of the plastic deformation under high pressure. We performed in situ synchrotron X-ray diffraction (XRD) experiments to study compression deformation behavior of the HEA MoNbTaVW in a radial diamond anvil cell (rDAC). Our results show that the strength and ratio of the stress-to-shear modulus values are ~1.5 and 3 times that of pure tungsten (W), respectively. MoNbTaVW showed plastic deformation above 5 GPa and displayed a much stronger texture. In this work, we found that the active dislocation behavior is mainly responsible for the high strength in MoNbTaVW under compression. This unique technique opens a new avenue to investigate the in situ mechanical properties and their mechanism in other types of HEAs.

36 MATERIALS SCIENCE↗

New dynamic diamond anvil cell for time-resolved radial x-ray diffraction

The dynamic diamond anvil cell (dDAC) is a recently developed experimental platform that has shown promise for studying the behavior of materials at strain rates ranging from intermediate to quasi-static and shock compression regimes. Combining dDAC with time-resolved x-ray diffraction (XRD) in the radial geometry (i.e., with incident x-rays perpendicular to the axis of compression) enables the study of material properties such as strength, texture evolution, and deformation mechanisms. This work describes a radial XRD dDAC setup at beamline P02.2 (Extreme Conditions Beamline) at DESY’s PETRA III synchrotron. Time-resolved radial XRD data are collected for titanium, zirconium, and zircon samples, demonstrating the ability to study the strength and texture of materials at compression rates above 300 GPa/s. In addition, the simultaneous optical imaging of the DAC sample chamber is demonstrated. The ability to conduct simultaneous radial XRD and optical imaging provides the opportunity to characterize plastic strain and deviatoric strain rates in the DAC at intermediate rates, exploring the strength and deformation mechanisms of materials in this regime.

47 OTHER INSTRUMENTATION↗

New dynamic diamond anvil cell for time-resolved radial x-ray diffraction

The dynamic diamond anvil cell (dDAC) is a recently developed experimental platform that has shown promise for studying the behavior of materials at strain rates ranging from intermediate to quasi-static and shock compression regimes. Combining dDAC with time-resolved x-ray diffraction (XRD) in the radial geometry (i.e., with incident x-rays perpendicular to the axis of compression) enables the study of material properties such as strength, texture evolution, and deformation mechanisms. This work describes a radial XRD dDAC setup at beamline P02.2 (Extreme Conditions Beamline) at DESY’s PETRA III synchrotron. Time-resolved radial XRD data are collected for titanium, zirconium, and zircon samples, demonstrating the ability to study the strength and texture of materials at compression rates above 300 GPa/s. In addition, the simultaneous optical imaging of the DAC sample chamber is demonstrated. The ability to conduct simultaneous radial XRD and optical imaging provides the opportunity to characterize plastic strain and deviatoric strain rates in the DAC at intermediate rates, exploring the strength and deformation mechanisms of materials in this regime.

47 OTHER INSTRUMENTATION↗

Understanding the effect of specimen size on the properties of fine-grain isotropic nuclear graphite for irradiation studies: Mechanical properties

Programs at Oak Ridge National Laboratory are investigating the effects of neutron irradiation in the High Flux Isotope Reactor (HFIR) on properties of fine-grain isotropic nuclear graphites. Specimens were irradiated in the HFIR flux trap, which requires using specimens that are smaller than the sizes recommended by ASTM standards. Here, this work has investigated whether subsized specimens can be used to reliably predict strength behavior. The results show that (1) tensile strength was loosely coupled to specimen volume, (2) the compression specimens had a slightly higher strength for larger volumes, (3) the uniaxial flexural strength was nearly independent of specimen effective area for one orientation whereas the other orientation showed a slight strength–size scaling Weibull behavior, and (4) equibiaxial flexural strength followed traditional strength–size scaling Weibull behavior. These results suggest that fine-grain graphite is more similar to ceramics than to medium- and large-grained graphite with respect to both the strength-limiting flaws (Griffith theory) and the effect of machining on the strength behavior. This work shows that using specimens that are smaller than ASTM recommendations are suitable for investigating the strength changes caused by neutron irradiation because the primary interest is the relative change in the strength distribution parameters rather than their absolute values.

36 MATERIALS SCIENCE↗

Effect of Grain Boundary Misorientation on Spall Strength in Ta via Shock-Free Simulations with Relatively Few Atoms

A suite of 37 molecular dynamics simulations is conducted at two system sizes to systematically characterize the role of grain boundary (GB) misorientation on spall strength in pure BCC tantalum (Ta). The systems studied consist of bicrystals with a single [110] symmetric tilt grain boundary. Two loading conditions are compared: (i) homogeneous extension under uniaxial strain simulated in this study and (ii) piston/flyer impact of sample, which induces heterogeneous deformation via shockwave propagation along the length of the sample. The piston/flyer impact is taken from the literature and run on the same set of GB misorientation angles using LAMMPS. The major finding here is that both methods result in similar spall strength predictions, but the homogeneous extension method generally requires two to three orders of magnitude fewer atoms and similar reductions in computational costs. Spall strength results systematically overpredict using this method, by about 10% for the dataset three orders of magnitude smaller than piston/flyer simulations, and 5% for the dataset two orders of magnitude smaller. Lastly, the effect of system size and pre-compression magnitude on spall strength is systematically characterized.

36 MATERIALS SCIENCE↗

Water-Dependent Blending of Pectin Films: The Mechanics of Conjoined Biopolymers

Biodegradable pectin polymers have been recommended for a variety of biomedical applications, ranging from the delivery of oral drugs to the repair of injured visceral organs. A promising approach to regulate pectin biostability is the blending of pectin films. To investigate the development of conjoined films, we examined the physical properties of high-methoxyl pectin polymer-polymer (homopolymer) interactions at the adhesive interface. Pectin polymers were tested in glass phase (10–13% w/w water content) and gel phase (38–41% w/w water content). The tensile strength of polymer-polymer adhesion was measured after variable development time and compressive force. Regardless of pretest parameters, the adhesive strength of two glass phase films was negligible. In contrast, adhesion testing of two gel phase films resulted in significant tensile adhesion strength (p < 0.01). Adhesion was also observed between glass phase and gel phase films—likely reflecting the diffusion of water from the gel phase to the glass phase films. In studies of the interaction between two gel phase films, the polymer-polymer adhesive strength increased linearly with increasing compressive force (range 10–80 N) (R 2 = 0.956). In contrast, adhesive strength increased logarithmically with time (range 10–10,000 s) (R 2 = 0.913); most of the adhesive strength was observed within minutes of contact. Fracture mechanics demonstrated that the adhesion of two gel phase films resulted in a conjoined film with distinctive physical properties including increased extensibility, decreased stiffness and a 30% increase in the work of cohesion relative to native polymers (p < 0.01). Scanning electron microscopy of the conjoined films demonstrated cross-grain adhesion at the interface between the adhesive homopolymers. These structural and functional data suggest that blended pectin films have emergent physical properties resulting from the cross-grain intermingling of interfacial pectin chains.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mechanical behavior analysis using small-size graphite disc compression testing with digital image correlation methods

The ASTM International Standard Test Method for Tensile Stress-Strain of Carbon and Graphite (ASTM C749) requires dog-bone shaped specimens. Unfortunately, specimen sizes required in ASTM C749 are much too large for irradiation within a test reactor and are incompatible with irradiation capsule volumes, molten salt degradation facilities, or oxidation apparatus. The ASTM International Standard Test Method for Tensile Strength Estimate by Disc Compression of Manufactured Graphite (ASTM D8289) was developed as an alternative that provides a means for testing tensile properties using smaller specimens when geometric constraints are present. However, the important stress–strain relation throughout the test loading history that could be recorded using ASTM C749 is lost by using ASTM D8289 because of the difficulties involved with using traditional strain gauges or extensometers on such a small specimen. In this work, a digital image correlation (DIC) method, which uses a full-field noncontact surface displacement measurement technique, was applied along with the ASTM D8289 splitting tensile test on eight small samples of graphite grade Mersen 2114 to track their deformation during compressive loading. Initial results showed that the DIC technique can measure the surface displacement/strain on these small (Ø6 × 3 mm) graphite specimens with high accuracy and good repeatability, indicating that the DIC technique, combined with the small-disc splitting tensile test in ASTM D8289, can capture the strain evolution in the test. In conclusion, further comparison of measured strains with analytical and numerical simulation results provides additional understanding of the mechanical behaviour of this nuclear graphite material in complex stress states.

36 MATERIALS SCIENCE↗