Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COMPARISON SOFTWARE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

SU-E-T-651: Quantification of Dosimetric Accuracy of Respiratory Gated Stereotactic Body Radiation Therapy

Purpose: To quantify the dosimetric accuracy of respiratory gated stereotactic body radiation therapy delivery using dynamic thorax phantom. Methods: Three patients with mobile target (2 lung, 1liver) were chosen. Retrospective 4DCT image sets were acquired for using Varian RPM system. An in-house MATLAB program was designed for MIP, MinIP and AvgIP generation. ITV was contoured on MIP image set for lung patients and on MinIP for liver patient. Dynamic IMRT plans were generated on selected phase bin image set in Eclipse (v10.0) planning system. CIRS dynamic thorax phantom was used to perform the dosimetric quality assurance. Patient breathing pattern file from RPM system was converted to phantom compatible file by an in-house MATLAB program. This respiratory pattern fed to the CIRS dynamic thorax phantom. 4DCT image set was acquired for this phantom using patient breathing pattern. Verification plans were generated using patient gating window and delivered on the phantom. Measurements were carried out using with ion chamber and EBT2 film. Exposed films were analyzed and evaluated in FilmQA software. Results: The stability of gated output in comparison with un-gated output was within 0.5%. The Ion chamber measured and TPS calculated dose compared for all the patients. The difference observed was 0.45%, −0.52% and −0.54 for Patient 1, Patient2 and Patient 3 respectively.Gamma value evaluated from EBT film shows pass rates from 92.41% to 99.93% for 3% dose difference and 3mm distance to agreement criteria. Conclusion: Dosimetric accuracy of respiratory gated SBRT delivery for lung and liver was dosimetrically acceptable. The Ion chamber measured dose was within 0.203±0.5659% of the expected dose. Gamma pass rates were within 96.63±3.84% of the expected dose.

61 RADIATION PROTECTION AND DOSIMETRY↗

An open source platform for multi-scale spatially distributed simulations of microbial ecosystems

The goal of this project was to develop a tool for facilitating simulation, validation and discovery of multiscale dynamical processes in microbial ecosystems. This led to the development of an open-source software platform for Computation Of Microbial Ecosystems in Time and Space (COMETS). COMETS performs spatially distributed time-dependent flux balance based simulations of microbial metabolism. Our plan involved building the software platform itself, calibrating and testing it through comparison with experimental data, and integrating simulations and experiments to address important open questions on the evolution and dynamics of cross-feeding interactions between microbial species.

97 MATHEMATICS AND COMPUTING↗

Benchmarking Algorithm for Radio Nuclide Identification (BARNI) Literature Review

This is a literature review of published radioisotope identification (ID) methods, and an attempt at systematic organization of the approaches for solving this problem. In addition, there is an overview of the related open and closed source software, and patents related to radioisotope identification. This document is also part of the development plan for BARNI (Benchmarking Algorithm for RadioNuclide Identification) software, since it is meant to be a comparison tool, a summary of radiation ID performance evaluations is also included.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Analysis and design of a high power, digitally-controlled spacecraft power system

The progress to date on the analysis and design of a high power, digitally controlled spacecraft power system is described. Several battery discharger topologies were compared for use in the space platform application. Updated information has been provided on the battery voltage specification. Initially it was thought to be in the 30 to 40 V range. It is now specified to be 53 V to 84 V. This eliminated the tapped-boost and the current-fed auto-transformer converters from consideration. After consultations with NASA, it was decided to trade-off the following topologies: (1) boost converter; (2) multi-module, multi-phase boost converter; and (3) voltage-fed push-pull with auto-transformer. A non-linear design optimization software tool was employed to facilitate an objective comparison. Non-linear design optimization insures that the best design of each topology is compared. The results indicate that a four-module, boost converter with each module operating 90 degrees out of phase is the optimum converter for the space platform. Large-signal and small-signal models were generated for the shunt, charger, discharger, battery, and the mode controller. The models were first tested individually according to the space platform power system specifications supplied by NASA. The effect of battery voltage imbalance on parallel dischargers was investigated with respect to dc and small-signal responses. Similarly, the effects of paralleling dischargers and chargers were also investigated. A solar array and shunt model was included in these simulations. A model for the bus mode controller (power control unit) was also developed to interface the Orbital replacement Unit (ORU) model to the platform power system. Small signal models were used to generate the bus impedance plots in the various operating modes. The large signal models were integrated into a system model, and time domain simulations were performed to verify bus regulation during mode transitions. Some changes have subsequently been incorporated into the models. The changes include the use of a four module boost discharger, and a new model for the mode controller, which includes the effects of saturation. The new simulations for the boost discharger show the improvement in bus ripple that can be achieved by phase-shifted operation of each of the boost modules.

Lee, F. C.↗

NAE Twin Otter operations in FIFE 1989

During the summer of 1989, the National Aeronautical Establishment (Canada) Twin Otter Atmospheric Research Aircraft was flow in support of the NASA sponsored First ISLSCP (International Satellite Land Surface Climatology Project) Field Experiment called FIFE-89. Airborne measurements of the fluxes of heat, momentum, water vapor and carbon dioxide were made during 16 flow-altitude flights over the FIFE project area in central Kansas. The Twin Otter operations in FIFE are documented and details are included on the instrumentation, software, flight procedures, atmospheric conditions and analysis methods. Comparisons of Twin Otter measured fluxes are made with those determined at several surface sites and with those made by other instrumented aircraft in the FIFE-87 measurements. Airborne flux measurements are related to run length, altitude, and environmental parameters such as vegetation type, temperature, and wind speed. One night flight was run in an attempt to measure the respiration component of the CO2 flux. The use of aircraft was studied for regional observations of fluxes and to relate these to satellite radiance measurements. Run average data are presented for all 285 flux runs flown by the Twin Otter in FIFE-89. This should serve as as a working reference for scientists utilizing Twin Otter data either directly of through the FIFE data archive.

Macpherson, J. I.↗

Estimation of propulsion-induced effects on transonic flows over a hypersonic configuration

Boundary conditions are formulated for treating selected patches of a subject configuration as inlet or nozzle areas. For subsonic inflow, the mass flow through the inlet is controlled by the exhaust conditions and the effects of mass and heat addition. For supersonic inflow, the exhaust conditions are based on the inlet conditions and on combustion data. These formulations were included into an existing Euler/Navier-Stokes solver. Comparisons with experimental data demonstrate that the resulting software package efficiently permits the assessment of propulsion-induced effects on external flow fields, particularly around highly blended configurations.

Hartwich, Peter M.↗

Conversion of bioprocess ethanol to industrial chemical products - Applications of process models for energy-economic assessments

An assessment approach for accurate evaluation of bioprocesses for large-scale production of industrial chemicals is presented. Detailed energy-economic assessments of a potential esterification process were performed, where ethanol vapor in the presence of water from a bioreactor is catalytically converted to ethyl acetate. Results show that such processes are likely to become more competitive as the cost of substrates decreases relative to petrolium costs. A commercial ASPEN process simulation provided a reasonably consistent comparison with energy economics calculated using JPL developed software. Detailed evaluations of the sensitivity of production cost to material costs and annual production rates are discussed.

Rohatgi, Naresh K.↗

Preliminary Structural Sizing and Alternative Material Trade Study of CEV Crew Module

This paper presents the results of a preliminary structural sizing and alternate material trade study for NASA s Crew Exploration Vehicle (CEV) Crew Module (CM). This critical CEV component will house the astronauts during ascent, docking with the International Space Station, reentry, and landing. The alternate material design study considers three materials beyond the standard metallic (aluminum alloy) design that resulted from an earlier NASA Smart Buyer Team analysis. These materials are graphite/epoxy composite laminates, discontinuously reinforced SiC/Al (DRA) composites, and a novel integrated panel material/concept known as WebCore. Using the HyperSizer (Collier Research and Development Corporation) structural sizing software and NASTRAN finite element analysis code, a comparison is made among these materials for the three composite CM concepts considered by the 2006 NASA Engineering and Safety Center Composite Crew Module project.

Bednarcyk, Brett A.↗

Understanding PIP Measurements of Particle Shape via Image Analysis

A number of instruments exist to measure the size, shape and orientation angle of precipitation particles near the surface; this study will specifically focus on three of them: the precipitation imaging package (PIP), the multi-angle snowflake camera (MASC), and the two-dimensional video distrometer (2DVD). The measurements of particular interest for developing precipitation microphysical retrievals from polarimetric radar and satellite-based microwave data are of the particle size, aspect ratio, and orientation angle. Due to differences in instrument design and processing software, however, the measurements made by PIP, MASC, and 2DVD are not in agreement on these key measurements. The aim of the present study is to understand how the differences between these three instruments impact their measurements of the size, aspect ratio, and orientation angle of winter precipitation particles. To this end, we have reprocessed the video files produced by PIP in a manner that replicates how the MASC and 2DVD instruments operate and process their respective data. Our findings suggest that the MASC processing software results in superior particle characteristic measurements in comparison to the other instruments, although a cursory comparison of measurements from the actual instruments suggests the PIP captures the largest number of particles of the three instruments, making PIP potentially better for computing distributions.

Charles N. Helms↗

An assessment of space shuttle flight software development processes

In early 1991, the National Aeronautics and Space Administration's (NASA's) Office of Space Flight commissioned the Aeronautics and Space Engineering Board (ASEB) of the National Research Council (NRC) to investigate the adequacy of the current process by which NASA develops and verifies changes and updates to the Space Shuttle flight software. The Committee for Review of Oversight Mechanisms for Space Shuttle Flight Software Processes was convened in Jan. 1992 to accomplish the following tasks: (1) review the entire flight software development process from the initial requirements definition phase to final implementation, including object code build and final machine loading; (2) review and critique NASA's independent verification and validation process and mechanisms, including NASA's established software development and testing standards; (3) determine the acceptability and adequacy of the complete flight software development process, including the embedded validation and verification processes through comparison with (1) generally accepted industry practices, and (2) generally accepted Department of Defense and/or other government practices (comparing NASA's program with organizations and projects having similar volumes of software development, software maturity, complexity, criticality, lines of code, and national standards); (4) consider whether independent verification and validation should continue. An overview of the study, independent verification and validation of critical software, and the Space Shuttle flight software development process are addressed. Findings and recommendations are presented.

Source record↗

PFLOTRAN-RepoTREND Source Term Comparison Summary.

Code inter-comparison studies are useful exercises to verify and benchmark independently developed software to ensure proper function, especially when the software is used to model high-consequence systems which cannot be physically tested in a fully representative environment. This summary describes the results of the first portion of the code inter-comparison between PFLOTRAN and RepoTREND, which compares the radionuclide source term used in a typical performance assessment.

97 MATHEMATICS AND COMPUTING↗

Mass Spectrometry Imaging of Biological Tissue: An Approach for Multicenter Studies

Mass spectrometry imaging has become a popular tool for probing the chemical complexity of biological surfaces. This led to the development of a wide range of instrumentation and preparation protocols. It is thus desirable to evaluate and compare the data output from different methodologies and mass spectrometers. Here, we present an approach for the comparison of mass spectrometry imaging data from different laboratories (often referred to as multicenter studies). This is exemplified by the analysis of mouse brain sections in five laboratories in Europe and the USA. The instrumentation includes matrix-assisted laser desorption/ionization (MALDI)-time-of-flight (TOF), MALDI-QTOF, MALDIFourier transform ion cyclotron resonance (FTICR), atmospheric-pressure (AP)-MALDI-Orbitrap, and cluster TOF-secondary ion mass spectrometry (SIMS). Experimental parameters such as measurement speed, imaging bin width, and mass spectrometric parameters are discussed. All datasets were converted to the standard data format imzML and displayed in a common open-source software with identical parameters for visualization, which facilitates direct comparison of MS images. The imzML conversion also allowed exchange of fully functional MS imaging datasets between the different laboratories. The experiments ranged from overview measurements of the full mouse brain to detailed analysis of smaller features (depending on spatial resolution settings), but common histological features such as the corpus callosum were visible in all measurements. High spatial resolution measurements of AP-MALDI-Orbitrap and TOF-SIMS showed comparable structures in the low-micrometer range. We discuss general considerations for planning and performing multicenter studies in mass spectrometry imaging. This includes details on the selection, distribution, and preparation of tissue samples as well as on data handling. Such multicenter studies in combination with ongoing activities for reporting guidelines, a common data format (imzML) and a public data repository can contribute to more reliability and transparency of MS imaging studies.

Environmental Molecular Sciences Laboratory↗

PARET/ANL (V.7.7) Verification and Validation Report

This report documents the software testing which has been performed for the PARET/ANL version 7.7 software. The software testing is based on code capabilities identified by research reactor analysts as frequently used in their safety analyses. The verification and validation procedures have been performed and documented to address the steady-state capabilities of the software, as described in Chapter 2, and the transient capabilities, as described in Chapter 3. Testing based on the comparison between PARET/ANL calculations and analytical solutions, hand calculations, or other code calculations of the test cases confirms that all the identified capabilities of the software were implemented correctly. In addition, results from code comparisons against SPERT-I and SPERT-IV experiments for various flow rates are reported for the peak power, energy release and cladding surface temperature. The comparisons showed overall good agreement for the peak power and conservative predictions of the cladding surface temperature

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

PARET/ANL v7.7 Verification and Validation Report

This report documents the software testing which has been performed for the PARET/ANL version 7.7 software. The software testing is based on code capabilities identified by research reactor analysts as frequently used in their safety analyses. The verification and validation procedures have been performed and documented to address the steady-state capabilities of the software, as described in Chapter 2, and the transient capabilities, as described in Chapter 3. Testing based on the comparison between PARET/ANL calculations and analytical solutions, hand calculations, or other code calculations of the test cases confirms that all the identified capabilities of the software were implemented correctly. In addition, results from code comparisons against SPERT-I and SPERT-IV experiments for various flow rates are reported for the peak power, energy release and cladding surface temperature. The comparisons showed overall good agreement for the peak power and conservative predictions of the cladding surface temperature.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Plutonium Critical Mass Curve Comparison to Mass at Upper Subcritical Limit (USL) Using Whisper

Whisper is computational software designed to assist the nuclear criticality safety analyst with validation studies with the MCNP ® Monte Carlo radiation transport package. Standard approaches to validation rely on the selection of benchmarks based upon expert judgment. Whisper uses sensitivity/uncertainty (S/U) methods to select relevant benchmarks to a particular application or set of applications being analyzed. Using these benchmarks, Whisper computes a calculational margin. Whisper attempts to quantify the margin of subcriticality (MOS) from errors in software and uncertainties in nuclear data. The combination of the Whisper-derived calculational margin and MOS comprise the baseline upper subcritical limit (USL), to which an additional margin may be applied by the nuclear criticality safety analyst as appropriate to ensure subcriticality. A series of critical mass curves for plutonium, similar to those found in Figure 31 of LA-10860-MS, have been generated using MCNP6.1.1 and the iterative parameter study software, WORM_Solver. The baseline USL for each of the data points of the curves was then computed using Whisper 1.1. The USL was then used to determine the equivalent mass for plutonium metal-water system. ANSI/ANS-8.1 states that it is acceptable to use handbook data, such as the data directly from the LA-10860-MS, as it is already considered validated (Section 4.3 4) “Use of subcritical limit data provided in ANSI/ANS standards or accepted reference publications does not require further validation.”). This paper attempts to take a novel approach to visualize traditional critical mass curves and allows comparison with the amount of mass for which the k eff is equal to the USL (calculational margin + margin of subcriticality). However, the intent is to plot the critical mass data along with USL, not to suggest that already accepted handbook data should have new and more rigorous requirements for validation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evolution of Flexible Multibody Dynamics for Simulation Applications Supporting Human Spaceflight

During the course of transition from the Space Shuttle and International Space Station programs to the Orion and Journey to Mars exploration programs, a generic flexible multibody dynamics formulation and associated software implementation has evolved to meet an ever changing set of requirements at the NASA Johnson Space Center (JSC). Challenging problems related to large transitional topologies and robotic free-flyer vehicle capture/ release, contact dynamics, and exploration missions concept evaluation through simulation (e.g., asteroid surface operations) have driven this continued development. Coupled with this need is the requirement to oftentimes support human spaceflight operations in real-time. Moreover, it has been desirable to allow even more rapid prototyping of on-orbit manipulator and spacecraft systems, to support less complex infrastructure software for massively integrated simulations, to yield further computational efficiencies, and to take advantage of recent advances and availability of multi-core computing platforms. Since engineering analysis, procedures development, and crew familiarity/training for human spaceflight is fundamental to JSC's charter, there is also a strong desire to share and reuse models in both the non-realtime and real-time domains, with the goal of retaining as much multibody dynamics fidelity as possible. Three specific enhancements are reviewed here: (1) linked list organization to address large transitional topologies, (2) body level model order reduction, and (3) parallel formulation/implementation. This paper provides a detailed overview of these primary updates to JSC's flexible multibody dynamics algorithms as well as a comparison of numerical results to previous formulations and associated software.

Multibody dynamics↗

SU-F-P-34: Commission of Enhanced Dynamic Wedge of Varian Truebeam Linac System with Feature Study

Purpose: To evaluate an Enhanced Dynamic Wedge (EDW) as part of machine commission process with feature study. Methods: The EDW system in this study was from a Truebeam, which is the Linear accelerator manufactured by Varian Medical Systems. The EDW feature vectors includes selected elements. These elements were dosimetric output spots check, field size, wedge angles, dose rate, collimator orientation, and different energy settings. Point dose measurement was done by a PTW farmer chamber, and profiles were measured by Gafchromic EBT2 films positing at different depths of the Solidwater based on the study elements. The output spot measurements were done with PTW farmer chamber with Solidwater setting for all orientation and wedge angles in the EDW system. The profiles comparisons were done by IMRT measurement function in RIT software at version 6.3. And the films were scanned by Vidar scanner. Dosimetry calculation were done by using the same Solidwater scanned by GE LightSpeed CT in Eclipse Treatment Planning System (TPS). Then measurements were compared to simulation results in TPS. Results: The energy average percentage difference between chamber measurement and TPS was 0.16% with standard deviation (SD) at 0.93%. For selected features, the average percentage difference between film measurement and computation was 0.93% with SD at 1.55% in horizontal profiles, and 1.18% with SD at 0.98% at vertical profiles. The average gamma difference for film measurement and TPS computing results was at 0.924 with SD at 0.314. Conclusion: A feature vector was developed to describe the commission of EDW, and developing a complete set of features for sufficiency of commission of a LINAC function could provide optimal commission instance with acceptable confident level of clinical application of the machine. Given the institution specific vector pattern and big data process, it could provide wide range clinical outcome comparison information in application of EDW.

60 APPLIED LIFE SCIENCES↗