Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COMFORT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Thermoelectric air conditioning undergarment for personal thermal management and HVAC energy saving

Personal thermal management systems (PTMS) are highly desirable for improving individual thermal comfort and reducing indoor HVAC energy consumption. Although there have been many attempts in developing PTMS, existing PTMS are generally bulky, heavy or immobile. Besides, previous analysis on additional personal cooling and heating power required for maintaining thermal comfort in changing environments did not consider the individual difference in metabolism and the variability of comfort skin temperature with environmental conditions. In this paper, we report on the development of a novel lightweight (<1 kg) thermoelectric air conditioning undergarment system with a preferred design of branching tubing network (branching angle of 60° and diameter ratio of 0.782) for air distribution. Through thermal manikin and human subject tests, we demonstrated that the novel system is capable of providing a maximum of 15.5 W of personal cooling and 18.1 W personal heating with a coefficient of performance (COP) greater than 0.4, which is sufficient to the expansion of the indoor set-points by at least 2.2 °C (4 °F) on both sides without compromising thermal comfort and the potential saving of about 15% HVAC energy. Furthermore, our study improved the understanding of the required additional personal cooling and heating power for changing environmental conditions, which are essential guidelines for the further development of PTMS.

42 ENGINEERING↗

Assessing the performance of global thermostat adjustment in commercial buildings for load shifting demand response

Abstract Efficiently leveraging new sources of flexibility is critical to mitigating load balancing challenges posed by variable renewable resources. The thermal inertia of commercial buildings allows us to shift their power consumption on minute to hourly timescales to provide demand response to the grid while maintaining occupant comfort. Global thermostat adjustment (GTA) provides a readily available and scalable approach for implementing load shifting demand response using commercial heating, ventilation, and air conditioning (HVAC) systems, since it leverages the inherent sophistication of modern building automation systems. However, there is an incomplete understanding of GTA’s performance for this purpose and its impact on building systems and occupant comfort. In this paper, we explore the performance of GTA by analyzing results from nearly nine hundred experiments on eight university campus buildings in Michigan and North Carolina. Using GTA, we manipulate each building’s thermostat setpoints causing the building to shift its power consumption with respect to its baseline. We quantify the magnitude of HVAC power response, energy use of HVAC subsystems, and impact on occupant comfort. Finally, we connect our experimental results with power system operation using an optimization model that coordinates GTA actions across a large collection of grid-interactive efficient buildings (GEBs) to reduce high ramp rates on the grid and mitigate renewable energy curtailment. Overall, our work finds that the impacts on HVAC subsystems are often complex, and may result in additional energy being consumed by fans and terminal reheat. These effects must be considered when using GTA for load shifting. Additionally, we demonstrate that occupant comfort, as assessed by indoor temperature and humidity, can be maintained during GTA events. From a societal perspective, our modeling work finds that the additional renewable energy that can be integrated through the use of GTA strategies eclipses any additional energy consumed by buildings.

Keskar, Aditya (ORCID:0000000244617980)↗

Appliance Commitment for Household Load Scheduling

This paper presents a novel appliance commitment algorithm that schedules thermostatically-controlled household loads based on price and consumption forecasts considering users comfort settings to meet an optimization objective such as minimum payment or maximum comfort. The formulation of an appliance commitment problem was described in the paper using an electrical water heater load as an example. The thermal dynamics of heating and coasting of the water heater load was modeled by physical models; random hot water consumption was modeled with statistical methods. The models were used to predict the appliance operation over the scheduling time horizon. User comfort was transformed to a set of linear constraints. Then, a novel linear, sequential, optimization process was used to solve the appliance commitment problem. The simulation results demonstrate that the algorithm is fast, robust, and flexible. The algorithm can be used in home/building energy-management systems to help household owners or building managers to automatically create optimal load operation schedules based on different cost and comfort settings and compare cost/benefits among schedules.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SU-E-T-540: Volumetric Modulated Total Body Irradiation Using a Rotational Lazy Susan-Like Immobilization System

Purpose: Traditional extended SSD total body irradiation (TBI) techniques can be problematic in terms of patient comfort and/or dose uniformity. This work aims to develop a comfortable TBI technique that achieves a uniform dose distribution to the total body while reducing the dose to organs at risk for complications. Methods: To maximize patient comfort, a lazy Susan-like couch top immobilization system which rotates about a pivot point was developed. During CT simulation, a patient is immobilized by a Vac-Lok bag within the body frame. The patient is scanned head-first and then feet-first following 180° rotation of the frame. The two scans are imported into the Pinnacle treatment planning system and concatenated to give a full-body CT dataset. Treatment planning matches multiple isocenter volumetric modulated arc (VMAT) fields of the upper body and multiple isocenter parallel-opposed fields of the lower body. VMAT fields of the torso are optimized to satisfy lung dose constraints while achieving a therapeutic dose to the torso. The multiple isocenter VMAT fields are delivered with an indexed couch, followed by body frame rotation about the pivot point to treat the lower body isocenters. The treatment workflow was simulated with a Rando phantom, and the plan was mapped to a solid water slab phantom for point- and film-dose measurements at multiple locations. Results: The treatment plan of 12Gy over 8 fractions achieved 80.2% coverage of the total body volume within ±10% of the prescription dose. The mean lung dose was 8.1 Gy. All ion chamber measurements were within ±1.7% compared to the calculated point doses. All relative film dosimetry showed at least a 98.0% gamma passing rate using a 3mm/3% passing criteria. Conclusion: The proposed patient comfort-oriented TBI technique provides for a uniform dose distribution within the total body while reducing the dose to the lungs.

60 APPLIED LIFE SCIENCES↗

Dynamic Response of a Semiactive Suspension System with Hysteretic Nonlinear Energy Sink Based on Random Excitation by means of Computer Simulation

This paper aims to investigate the property and behavior of the hysteretic nonlinear energy sink (HNES) coupled to a half vehicle system which is a nine-degree-of-freedom, nonlinear, and semiactive suspension system in order to improve the ride comfort and increase the stability in shock mitigation by using the computer simulation method. The HNES model is a semiactive suspension device, which comprises the famous Bouc–Wen (B-W) model employed to describe the force produced by both the purely hysteretic spring and linear elastic spring of potentially negative stiffness connected in parallel, for the half vehicle system. Nine nonlinear motion equations of the half vehicle system are derived in terms of the seven displacements and the two dimensionless hysteretic variables, which are integrated numerically by employing the direct time integration method for studying both the variables of vertical displacements, velocities, accelerations, chassis pitch angle, and the ride comfort and driver safety, respectively, based on the bump and random road inputs of the pseudoexcitation method as excitation signal. Simulation results show that, compared with the HNES model and the magnetorheological (MR) model coupled to the half vehicle system, the ride comfort and stability have been evidently improved. A successful validation process has been performed, which indicated that both the ride comfort and driver safety properties of the HNES model coupled to half vehicle significantly improved.

Chen, Hui↗

Building Agent™ Software (BA) [SWRs 12-05 and 17-21]

Energy interfaces provide a new level of motivational information. Many studies have reported energy savings after dashboards for operators are installed, but these provide little actionable information to the occupant and the occupant cannot report individual comfort. The Building Agent™ (BA), in development at the National Renewable Energy Laboratory (NREL), provides an interface for the occupant to converse with the building control system and aims to actively engage and affect occupant behavior to achieve positive energy outcomes. Energy savings achieved via occupant behavioral changes could be as high as 25%, and could rival savings achieved by technological measures. For example, energy audits often show that more than 50% of the energy used in a building is consumed at night. Occupants leaving equipment and lighting on after they leave work is a large contributing factor. Similar savings opportunities have been identified when occupants were away from their desks 50% of the time, while most of their computers, lights, and other equipment remained powered on. Building Agent aims to create cohesion between building automation system (BAS) data, local measurements, and occupant feedback to provide visualizations, empowering occupants and building engineers to take diagnostic, proactive, energy-saving, and comfort-improving actions. The multilayer BA architecture consists of central server, measurement, and distributed application layers. The server layer aggregates global and localized measurements with occupant feedback to correlate perceived comfort with actual data throughout the building. The measurement layer complements BAS data with localized, environmental condition measurements at workstations. The application layer provides a bidirectional communications mechanism between the building and the occupants that accepts comfort feedback and provides energy performance information. The interface layer also uses three displays to influence building energy use: empathetic and personalized gauges, graphical data, and competitive rankings. Building Agent was implemented at NREL in the Research Support Facility (RSF), a LEED Platinum and Net Zero office building, which has received many awards. The constant feedback from occupants has enabled BA to better enhance the BAS data controls. Continued work is being done on BA to increase visualization of data and enhanced the user experience.

Long, Nicholas↗

Low-E Retrofit Demonstration and Educational Program

The objective of this project was to demonstrate the capability of low-emissivity (low-E) storm windows / panels and low-E retrofit glazing systems to significantly and cost effectively improve the energy efficiency of both existing residential and commercial buildings. The key outcomes are listed below: RESIDENTIAL CASE STUDIES: (a) A residential case study in two large multifamily apartment buildings in Philadelphia showed a substantial 18-22% reduction in heating energy use and a 9% reduction in cooling energy use by replacing old clear glass storm windows with modern low-E storm windows. Furthermore, the new low-E storm windows reduced the overall apartment air leakage by an average of 10%. (b) Air leakage testing on interior low-E panels installed in a New York City multifamily building over windows with and without AC units showed that the effective leakage area of the windows was reduced by 77-95%. (c) To study the use of low-E storm windows in a warmer mixed climate with a balance of both heating and cooling, 10 older homes near Atlanta with single pane windows were tested with three types of exterior storm windows: clear glass, low-E glass with high solar heat gain, and low-E glass with lower solar heat gain. The storm windows significantly reduced the overall home air leakage by an average of 17%, or 3.7 ACH50. Considerably high variability in the data made it difficult to draw strong conclusions about the overall energy usage, but for heating periods, the low-E storm windows showed approximately 15% heating energy savings, whereas clear storm windows were neutral in performance. For cooling periods, the low-E storm windows showed a wide range of performance from 2% to over 30% cooling energy savings. Overall, the study showed the potential for significantly more energy savings from using low-E glass versus no storm window or clear glass storm windows in warmer mixed climates, but it is difficult to conclusively say whether one type of low-E performed better than the other. COMMERCIAL CASE STUDIES: (a) A 12-story office building in Philadelphia was retrofitted by adding a double-pane low-E insulating glass unit to the existing single pane windows, to create a triple glazed low-E system. A detailed side-by-side comparison in two pairs of perimeter offices facing north and east showed a 39-60% reduction in heating energy use, a 9-36% reduction in cooling energy use, and a 10% reduction in peak electrical cooling demand. An analysis of utility bills estimated the whole building heating and cooling energy use was reduced by over 25%. Additionally, the retrofit window temperatures were commonly 20 degrees warmer on winter days, and 10-20 degrees cooler on summer days, leading to increased occupant comfort. (b) Two large 4-story office buildings in New Jersey were retrofitted with a similar system, but using two low-E coatings in the retrofit system. The energy savings are being monitored by a separate GPIC project; this work quantified the changes in glass surface temperatures, thermal comfort, and potential glass thermal stress. The low-E retrofit panels greatly reduced daily variations in the interior window surface temperatures, lowering the maximum temperature and raising the minimum temperature by over 20F compared to the original single pane windows with window film. The number of hours of potential thermal discomfort, as measured by deviation between mean radiant temperature and ambient air temperature by more than 3F, were reduced by 93 percent on the south orientation and over two-thirds on the west orientation. Overall, the low-E retrofit led to substantially improved occupant comfort with less periods of both overheating and feeling cold. (c) No significant thermal stress was observed in the New Jersey office building test window when using the low-E retrofit system over a variety of weather conditions. The surface temperature difference only exceeded 10F (500 psi thermal stress) for less than 1.5% of the monitored time, and in all cases, the maximum surface temperature difference never exceeded 35F (1,750 psi thermal stress). LOW-E STORM WINDOW OUTREACH AND EDUCATION PROGRAM: (a) The project team assisted the State of Pennsylvania in adding low-E storm windows as a cost effective weatherization measure on its priority list for the state weatherization assistance program. (b) No technical barriers that could hinder widespread application were identified in the case studies. However, educational barriers have been identified, in that weatherization personnel commonly misunderstand how the application of low-E storm windows is very different than much more expensive full window replacement. (c) A package of educational materials was developed to help communicate the benefits of low-E storm windows and retrofits as a cost effective tool for weatherization personnel. (d) Using detailed thermal simulations, more accurate U-factor and solar heat gain coefficient (SHGC) values were determined for low-E storm windows installed over different primary windows. IN SUMMARY, this work confirmed the potential for low-E storm windows, panels, and retrofit systems to provide significant energy savings, reductions in air leakage, and improvements in thermal comfort in both residential and commercial existing buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sensor Impact Evaluation and Verification Technical Advisory Group Meeting Minutes

This report provides the technical advisory group meeting minutes and summary of detailed discussions for future development of sensor impact evaluations and verifications. Methods for sensor configuration/deployment have critical impacts on energy-efficient building control and thermal comfort. However, traditional sensor techniques for building operation and fault detection and diagnostics (FDD) are not optimal in terms of energy efficiency and thermal comfort, and their global effects are not thoroughly investigated. In an effort to address and overcome this limitation, a 3 year project, Sensor Impact Evaluation and Verification, was proposed. The multi-laboratory team—the US Department of Energy’s Oak Ridge National Laboratory (ORNL), Pacific Northwest National Laboratory (PNNL), and the National Renewable Energy Laboratory (NREL)—is conducting early-stage R&D to provide technical supports and guidelines for sensor design in building/HVAC systems to optimize building energy use, FDD, thermal comfort, and grid efficiency. The overall goal of this project is to develop a framework that enables quantitative evaluation of the impact of sensors on building HVAC control, FDD, and consequently, building energy efficiency and thermal comfort.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of the Energy, Hygrothermal, and Thermal Capacity Performance of Cross-Laminated Timber

Cross-laminated timber (CLT) construction is gaining momentum in the US because it offers multiple advantages over traditional construction methods. Benefits that have received the most attention focus on constructability, the environment, and protection (e.g., blast resistance), although CLT construction is likely to offer other benefits, as well. Still, these have not been studied at length because such evaluations are costly, requiring long-term assessments in an actual building and specialized technical knowledge. Among the possible benefits, CLT construction likely provides a higher-performing building envelope. Using CLT panels to enclose a building means fewer joints in the opaque envelope than what is required in traditional stick-framed construction. Fewer joints mean fewer locations where the air- and water-resistive barrier (WRB) could be compromised; thus, a CLT building enclosure may require less maintenance and have a longer lifespan than a traditionally built structure because of fewer air and water leaks. In addition, CLT’s thermal mass moderates indoor temperatures, allowing the heating, ventilation, and air conditioning (HVAC) system to operate more efficiently during peak hours, reducing operational energy consumption throughout the lifetime of the CLT building (Salonvaara et al., 2022). Furthermore, more stable indoor temperatures can increase occupant comfort. The CLT’s thermal mass can also reduce energy costs by adjusting to utility time-of-use pricing without affecting occupant comfort. The ability of CLT buildings to bridge periods without HVAC operation prepares them for future grid interaction and provides a certain level of resilience against power outages. Researchers have attempted to quantify these benefits; however, their work is based on simplified simulations with numerous assumptions. To correctly understand the benefits, an actual building must be monitored. Therefore, information needs to be gathered on indoor and outdoor temperatures, HVAC energy consumption, thermostat setpoints, temperatures, and thermal transport in CLT components to comprehend how these parameters are affected by the CLT’s thermal mass. These data are needed to reduce the number of assumptions and calibrate simulation models to optimize HVAC controls to minimize overall energy consumption, reduce energy use and higher fees during peak demand, and maintain occupant comfort. Additionally, the calibrated simulation model allows the optimization exercise to be repeated in various US climates. Potential benefits can be tailored to buildings in various locations, and decisions can be made on where CLT construction could be most advantageous. Furthermore, monitoring and simulation results are needed to evaluate the durability of the CLT structures in different climates. This project’s researchers gathered information to help understand and quantify the benefits of CLT buildings concerning operational energy, moderated indoor temperatures, and comfort; the dynamic operation to provide grid services; and resilience in times of power outage. Through the corroboration of simulation models with real-world measurements, this study paves the way for extrapolating findings to other climatic zones and building typologies, thereby broadening the understanding of CLT’s multifaceted benefits and reinforcing its position as a material of choice in sustainable construction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ride quality evaluation. I

As part of a larger effort to assess passenger comfort in aircraft, two questionnaires were administered: one to ground-based respondents, the other to passengers in flight. Respondents indicated the importance of various factors influencing their satisfaction with a trip, the perceived importance of various physical factors in determining their level of comfort, and the ease of time spent performing activities in flight. The in-flight sample also provided a rating of their level of comfort and of their willingness to fly again. Comfort ratings were examined in relation to (1) type of respondent, (2) type of aircraft, (3) characteristics of the passengers, (4) ease of performing activities, and (5) willingness to fly again.

Richards, L. G.↗

Human confort response to random motions with a dominant rolling motion

Subjective ride comfort response ratings were measured on a visual motion simulator with rolling velocity inputs with various power spectra shapes and magnitudes. The results show only little influence of spectra shape on comfort response. The effects of magnitude on comfort response indicate the applicability of psychophysical precepts for comfort modeling.

Stone, R. W., Jr.↗

Subjective response to combined noise and vibration during flight of a large twin-jet airplane

A NASA twin-jet airplane was used to obtain controlled noise and vibration environments during flight while obtaining subjective responses from 13 passenger-subjects (6 females and 7 males). Subjective ratings of overall comfort, comfort when considering only vibration, and comfort when considering only noise were obtained during times of different vibration and noise environments. Passenger-subjects were able to distinguish and rate noise better than vibration. In addition, there was a statistically significant difference in ratings of ride comfort due to both sex type and flight experience. Males rated flying discomfort much more severely than females when rating the overall ride and the ride when considering only the noise environment. Experienced passengers also rated the overall ride to be more uncomfortable than inexperienced passengers.

Clevenson, S. A.↗

Ride quality evaluation. IV - Models of subjective reaction to aircraft motion

The paper examines models of human reaction to the motions typically experienced on short-haul aircraft flights. Data are taken on the regularly scheduled flights of four commercial airlines - three airplanes and one helicopter. The data base consists of: (1) a series of motion recordings distributed over each flight, each including all six degrees of freedom of motion; temperature, pressure, and noise are also recorded; (2) ratings of perceived comfort and satisfaction from the passengers on each flight; (3) moment-by-moment comfort ratings from a test subject assigned to each airplane; and (4) overall comfort ratings for each flight from the test subjects. Regression models are obtained for prediction of rated comfort from rms values for six degrees of freedom of motion. It is shown that the model C = 2.1 + 17.1 T + 17.2 V (T = transverse acceleration, V = vertical acceleration) gives a good fit to the airplane data but is less acceptable for the helicopter data.

Jacobson, I. D.↗

The development of interior noise and vibration criteria

A generalized model was developed for estimating passenger discomfort response to combined noise and vibration. This model accounts for broadband noise and vibration spectra and multiple axes of vibration as well as the interactive effects of combined noise and vibration. The model has the unique capability of transforming individual components of noise/vibration environment into subjective comfort units and then combining these comfort units to produce a total index of passenger discomfort and useful sub-indices that typify passenger comfort within the environment. An overview of the model development is presented including the methodology employed, major elements of the model, model applications, and a brief description of a commercially available portable ride comfort meter based directly upon the model algorithms. Also discussed are potential criteria formats that account for the interactive effects of noise and vibration on human discomfort response.

Leatherwood, J. D.↗

Augmentation of blood circulation to the fingers by warming distant body areas

Future activities in space will require greater periods of time in extreme environments in which the body periphery will be vulnerable to chilling. Maintaining the hands and fingers in comfortable conditions enhances finger flexibility and dexterity, and thus effects better work performance. We have evaluated the efficacy of promoting heat transfer and release by the extremities by increasing the blood flow to the periphery from more distant parts of the body. The experimental garment paradigm developed by the investigators was used to manipulate the temperature of different body areas. Six subjects, two females and four males, were evaluated in a stage-1 baseline condition, with the inlet temperature of the circulating water in the liquid cooling/warming garment (LCWG) at 33 degrees C. At stage 2 the total LCWG water inlet temperature was cooled to 8 degrees C, and at stage 3 the inlet water temperature in specific segments of the LCWG was warmed (according to protocol) to 45 degrees C, while the inlet temperature in the rest of the LCWG was maintained at 8 degrees C. The following four body-area-warming conditions were studied in separate sessions: (1) head, (2) upper torso/arm, (3) upper torso/arm/head, and (4) legs/feet. Skin temperature, heat flux and blood perfusion of the fingers, and subjective perception of thermal sensations and overall physical comfort were assessed. Finger temperature (T(fing)) analyses showed a statistically significant condition x stage interaction. Post-hoc comparisons (T(fing)) indicated that at stage 3, the upper torso/arm/head warming condition was significantly different from the head, upper torso/arm and legs/feet conditions, showing an increase in T(fing). There was a significant increase in blood perfusion in the fingers at stage 3 in all conditions. Subjective perception of hand warmth, and overall physical comfort level significantly increased in the stage 3 upper torso/arm/head condition. The findings indicate that physiological methods to enhance heat transfer by the blood to the periphery within protective clothing provide an additional tool for increasing total and local human comfort in extreme environments.

NASA Discipline Life Sciences Technologies↗

Display and Automation Considerations for the Airborne Collision Avoidance System Xu

In this paper we examine several display and automation considerations of a collision avoidance system that is currently under development: the Airborne Collision Avoidance System (ACAS) Xu. This study builds on previous work conducted as part of NASA’s Unmanned Aircraft Systems (UAS) Integration into the National Airspace System (NAS) project. ACAS Xu represents the next-generation successor to the Traffic Alert and Collision Avoidance System (TCAS II), wherein the Xu variant is intended for UAS applications. Whereas TCAS II exclusively issues RAs in the vertical dimension, a major distinction between ACAS Xu and previous collision avoidance (CA) systems is the introduction of horizontal and “blended” RAs (i.e., RAs with both horizontal and vertical components). This present work was conducted as an engineering analysis involving two parts. In Part 1, a two-by-two, within-subjects study was performed that manipulated how RAs were presented to a pilot situated at a UAS ground control station. Five participants experienced four experimental trials in which text and aural alerting characteristics were manipulated. In Part 2, another five participants experienced four trials in which the levels of automation were manipulated with regard to the CA and return-to-course (RTC) tasks. The results for Part 1 found no effect of display or alerting configuration on pilot performance. However, it was discovered that pilot response time to RAs greatly depended on the RA type. In particular, pilots were quicker to respond to vertical RAs (M = 4.52 seconds) than horizontal (M = 7.42 seconds) and blended (M = 9.68 seconds) RAs in which both dimensions were issued simultaneously. For Part 2 of the study, pilots found both auto-CA and auto-RTC functions equally useful. Most pilots were comfortable with the automation, however responses were mixed. Three of five participants indicated high levels of comfort with the auto-CA function, while two rated their comfort as low. Pilots’ comfort for the auto-RTC functionality was slightly higher: four out of five pilots gave high ratings, while one pilot gave a low rating. Overall, pilots ordinally ranked their preference for automated functions as auto-CA together with auto-RTC (when an aural alert announces a change between CA and RTC states), auto-CA, and auto-CA and RTC (without the aural state-change announcement). Recommendations for improving the display of automation are also discussed.

collision avoidance↗

Display and Automation Considerations for the Airborne Collision Avoidance System Xu

In this presentation we examine several display and automation considerations of a collision avoidance system that is currently under development: the Airborne Collision Avoidance System (ACAS) Xu. This study builds on previous work conducted as part of NASA’s Unmanned Aircraft Systems (UAS) Integration into the National Airspace System (NAS) project. ACAS Xu represents the next-generation successor to the Traffic Alert and Collision Avoidance System (TCAS II), wherein the Xu variant is intended for UAS applications. Whereas TCAS II exclusively issues RAs in the vertical dimension, a major distinction between ACAS Xu and previous collision avoidance (CA) systems is the introduction of horizontal and “blended” RAs (i.e., RAs with both horizontal and vertical components). This present work was conducted as an engineering analysis involving two parts. In Part 1, a two-by-two, within-subjects study was performed that manipulated how RAs were presented to a pilot situated at a UAS ground control station. Five participants experienced four experimental trials in which text and aural alerting characteristics were manipulated. In Part 2, another five participants experienced four trials in which the levels of automation were manipulated with regard to the CA and return-to-course (RTC) tasks. The results for Part 1 found no effect of display or alerting configuration on pilot performance. However, it was discovered that pilot response time to RAs greatly depended on the RA type. In particular, pilots were quicker to respond to vertical RAs (M = 4.52 seconds) than horizontal (M = 7.42 seconds) and blended (M = 9.68 seconds) RAs in which both dimensions were issued simultaneously. For Part 2 of the study, pilots found both auto-CA and auto-RTC functions equally useful. Most pilots were comfortable with the automation, however responses were mixed. Three of five participants indicated high levels of comfort with the auto-CA function, while two rated their comfort as low. Pilots’ comfort for the auto-RTC functionality was slightly higher: four out of five pilots gave high ratings, while one pilot gave a low rating. Overall, pilots ordinally ranked their preference for automated functions as auto-CA together with auto-RTC (when an aural alert announces a change between CA and RTC states), auto-CA, and auto-CA and RTC (without the aural state-change announcement). Recommendations for improving the display of automation are also discussed.

collision avoidance↗

Application of Bioengineering in Space Exploration - Sleep Study System

Bioengineering has spread roots far and wide among the needs of space exploration. The field creates many of paths to generate information from a variety of sources. One such source is the astronauts on the International Space Station (ISS). As of now the investigation is focused on the quality of sleep of crew members during a long duration flight. Our team is investing time into a piece of hardware’s comfort, waste, and operability. The hardware was not originally designed for space; therefore, the device must be modified to function at a optimal level in space. The design not made for space has generated some ailments, such as discomfort and decreased mobility. A function of the internship was to produce designs that would manage the wires to increase mobility and comfort. The wires excess slack was reduced by the part that was designed. The piece was adjustable, so the patient may adjust the system to their comfort and space compatible material was used. This product will help control the direction and length of the wires, thereby aiding in comforting the patient. This multifaceted design may be used in future for all other wire management for wearable biomedical sensor on orbit.

Biomedical↗