Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CAVITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Status of the mechanical design of the 650 MHz cavities for Project X

In the high-energy section of the Project X Linac, acceleration of H{sup -} ions takes place in superconducting cavities operating at 650 MHz. Two families of five-cell elliptical cavities are planned: beta = 0.61 and beta = 0.9. A specific feature of the Project X Linac is low beam loading, and thus, low bandwidth and higher sensitivity to microphonics. Efforts to optimize the mechanical design of the cavities to improve their mechanical stability in response to the helium bath pressure fluctuations will be presented. These efforts take into account constraints such as cost and ease of fabrication. Also discussed will be the overall design status of the cavities and their helium jackets. The proposed design of the 3 GeV Project X superconducting (SC) Linac employs 650 MHz five-cell elliptical cavities to accelerate 1.0 mA of average H-beam current in the 160-3000 MeV energy range. The 650 MHz region of the Linac is divided into two sections with two different geometric phase velocity factors: beta = 0.61 to cover the 160-520 MeV range and beta = 0.9 to cover the 520-3000 MeV range. Approximately 40 beta = 0.61 and 150 beta = 0.9 cavities are currently planned for the project. An R&D program is in progress at FNAL, in collaboration with TJNAF and India, to develop the 650 MHz cavities for the proposed Linac design. This R&D program includes the design and fabrication of several beta = 0.61 and beta = 0.9 single-cell prototypes for evaluation prior to production of the five-cell cavities. FNAL has contracted AES to fabricate the beta = 0.9 prototypes, while TJNAF is building beta = 0.61 prototypes of their own design. In the remainder of this paper we will restrict our discussion to the five-cell beta = 0.9 cavities.

43 PARTICLE ACCELERATORS↗

1.3 GHz superconducting RF cavity program at Fermilab

At Fermilab, 9-cell 1.3 GHz superconducting RF (SRF) cavities are prepared, qualified, and assembled into cryomodules (CMs) for Project X, an International Linear Collider (ILC), or other future projects. The 1.3 GHz SRF cavity program includes targeted R&D on 1-cell 1.3 GHz cavities for cavity performance improvement. Production cavity qualification includes cavity inspection, surface processing, clean assembly, and one or more cryogenic low-power CW qualification tests which typically include performance diagnostics. Qualified cavities are welded into helium vessels and are cryogenically tested with pulsed high-power. Well performing cavities are assembled into cryomodules for pulsed high-power testing in a cryomodule test facility, and possible installation into a beamline. The overall goals of the 1.3 GHz SRF cavity program, supporting facilities, and accomplishments are described.

43 PARTICLE ACCELERATORS↗

Hydroforming of Multi-Cell Niobium and NbCu-Clad Cavities

Technological aspects of seamless tube fabrication and multi-cell cavity production by hydroforming will be discussed. Problems related to the fabrication of seamless cavities from bulk niobium are mainly solved. Several two cell- and three cell- niobium cavities have been produced by hydroforming at DESY. A 9-cell cavity of the TESLA shape has been completed from three sub-sections at company ZANON. The cavity was treated by electropolishing (EP) and successfully RF-tested. Two 3-cell units equipped with niobium beam pipes are being RF-tested after BCP surface treatment. The temperature mapping method with Jlab’s two-cell thermometry system is applied for performance analysis. It is of particular interest to compare the seamless cavity quench locations to those from standard cavities. The cryogenic test results and the T-mapping findings will be discussed. Of special interest is the combination of the seamless technique with NbCu cladding, i.e. the fabrication of cavity from bimetallic clad NbCu tube by hydroforming. Fabrication of single-cell and multi-cell NbCu clad cavities by hydroforming from bimetallic tubes is proven. Some test results will be presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Novel deflecting cavity design for eRHIC

To prevent significant loss of the luminosity due to large crossing angle in the future ERL based Electron Ion Collider at BNL (eRHIC), there is a demand for crab cavities. In this article, we will present a novel design of the deflecting/crabbing 181 MHz superconducting RF cavity that will fulfil the requirements of eRHIC. The quarter-wave resonator structure of the new cavity possesses many advantages, such as compact size, high R{sub t}/Q, the absence of the same order mode and lower order mode, and easy higher order mode damping. We will present the properties and characteristics of the new cavity in detail. As the accelerator systems grow in complexity, developing compact and efficient deflecting cavities is of great interest. Such cavities will benefit situations where the beam line space is limited. The future linac-ring type electron-ion collider requires implementation of a crab-crossing scheme for both beams at the interaction region. The ion beam has a long bunches and high rigidity. Therefore, it requires a low frequency, large kicking angle deflector. The frequency of the deflecting mode for the current collider design is 181 MHz, and the deflecting angle is {approx}5 mrad for each beam. At such low frequency, the previous designs of the crab cavities will have very large dimensions, and also will be confronted by typical problems of damping the Lower Order Mode (LOM), the Same Order Mode (SOM), and as usual, the Higher Order Modes (HOM). In this paper we describe how one can use the concept of a quarter-wave (QW) resonator for a deflecting/crabbing cavity, and use its fundamental mode to deflect the beam. The simplicity of the cavity geometry and the large separation between its fundamental mode and the first HOM make it very attractive.

43 PARTICLE ACCELERATORS↗

Effect of H and He Irradiation on Cavity Formation and Blistering in Ceramics

Single- or poly-crystalline specimens of SiC, Si{sub 3}N{sub 4}, MgO, Al{sub 2}O{sub 3} and MgAl{sub 2}O{sub 4} were implanted with 0.4-1 MeV H{sup +} or He{sup +} ion beams at room temperature and 650 C up to fluences of {approx}1 x 10{sup 22}/m{sup 2}. This produced peak implanted gas and displacement damage levels as high as {approx}50 at.% and 34 displacements per atom (dpa). The specimens were subsequently examined optically, and in cross-section using transmission electron microscopy. Subsurface blistering occurred for specimens irradiated to H or He fluences greater than about 3 x 10{sup 21}/m{sup 2} ({approx}15 at.% peak implanted gas concentration), and surface exfoliation occurred for fluences above {approx}1 x 10{sup 22}/m{sup 2} ({approx}40 at.% implanted gas). Both helium and hydrogen had comparable effectiveness for inducing blistering and exfoliation on an atomic basis. The threshold blistering and exfoliation fluences for both ions were weakly dependent on temperature between 25 and 650 C. Both H and He were found to be very effective in inducing matrix cavity formation, due to their low solubility in these ceramics. The implanted gas concentrations that resulted in visible cavity formation generally ranged from 1 to 5 at.%. Visible cavity formation was readily induced during room temperature irradiation despite the limited vacancy mobility in these ceramics at room temperature. Three general types of cavity morphologies were observed: isolated cavities, clusters of small cavities (typically associated with dislocation loops), and two-dimensional platelets. Cavity formation was observed to initiate at the periphery of dislocation loops in some cases. During elevated temperature irradiation, cavity formation was often observed to be preferentially associated with certain low-index habit planes, particularly if the habit plane was oriented nearly parallel to the irradiated surface: (0001) and {l_brace}1{bar 1}00{r_brace} for Al{sub 2}O{sub 3}, (0001) for a-SiC, {l_brace}001{r_brace} and {l_brace}110{r_brace} for MgO, and {l_brace}110{r_brace} and {l_brace}111{r_brace} for MgAl{sub 2}O{sub 4}. The bubble formation and blistering behavior of the ceramics was similar to that observed in other studies of metals irradiated at comparable homologous temperatures. Ionization-induced diffusion effects associated with dual-beam light ion irradiation appeared to exert only a weak effect on cavity and dislocation loop growth compared to the single ion irradiation conditions.

08 HYDROGEN↗

A Resonant Cavity Approach to Non-Invasive, Pulse-to-Pulse EmittanceMeasurement

We present a resonant cavity approach for non-invasive, pulse-to-pulse, beam emittance measurements of non-circular multi-bunch beams. In a resonant cavity, desired field components can be enhanced up to Q{sub L{lambda}}/{pi}, where Q{sub L{lambda}} is the loaded quality factor of the resonant mode {lambda}, when the cavity resonant mode matches the bunch frequency of a bunch-train beam pulse. In particular, a quad-cavity, with its quadrupole mode (TM{sub 220} for rectangular cavities) at beam operating frequency, rotated 45{sup o} with respect to the beamline, extracts the beam quadrupole moment exclusively, utilizing the symmetry of the cavity and some simple networks to suppress common modes. Six successive beam quadrupole moment measurements, performed at different betatron phases in a linear transport system determine the beam emittance, i.e. the beam size and shape in the beam's phase space, if the beam current and position at these points are known. In the presence of x-y beam coupling, ten measurements are required. One measurement alone provides the rms-beam size of a large aspect ratio beam. The resolution for such a measurement of rms-beam size with the rectangular quad-cavity monitor presented in this article is estimated to be on the order of ten microns. A prototype quad-cavity was fabricated and preliminary beam tests were performed at the Next Linear Collider Test Accelerator (NLCTA) at the Stanford Linear Accelerator Center (SLAC). Results were mainly limited by beam jitter and uncertainty in the beam position measurement at the cavity location. This motivated the development of a position-emittance integrated monitor.

43 PARTICLE ACCELERATORS↗

Two-Dimensional Computational Fluid Dynamics and Conduction Simulations of Heat Transfer in Horizontal Window Frames with Internal Cavities

This paper assesses the accuracy of the simplified frame cavity conduction/convection and radiation models presented in ISO 15099 and used in software for rating and labeling window products. Temperatures and U-factors for typical horizontal window frames with internal cavities are compared; results from Computational Fluid Dynamics (CFD) simulations with detailed radiation modeling are used as a reference. Four different frames were studied. Two were made of polyvinyl chloride (PVC) and two of aluminum. For each frame, six different simulations were performed, two with a CFD code and four with a building-component thermal-simulation tool using the Finite Element Method (FEM). This FEM tool addresses convection using correlations from ISO 15099; it addressed radiation with either correlations from ISO 15099 or with a detailed, view-factor-based radiation model. Calculations were performed using the CFD code with and without fluid flow in the window frame cavities; the calculations without fluid flow were performed to verify that the CFD code and the building-component thermal-simulation tool produced consistent results. With the FEM-code, the practice of subdividing small frame cavities was examined, in some cases not subdividing, in some cases subdividing cavities with interconnections smaller than five millimeters (mm) (ISO 15099) and in some cases subdividing cavities with interconnections smaller than seven mm (a breakpoint that has been suggested in other studies). For the various frames, the calculated U-factors were found to be quite comparable (the maximum difference between the reference CFD simulation and the other simulations was found to be 13.2 percent). A maximum difference of 8.5 percent was found between the CFD simulation and the FEM simulation using ISO 15099 procedures. The ISO 15099 correlation works best for frames with high U-factors. For more efficient frames, the relative differences among various simulations are larger. Temperature was also compared, at selected locations on the frames. Small differences was found in the results from model to model. Finally, the effectiveness of the ISO cavity radiation algorithms was examined by comparing results from these algorithms to detailed radiation calculations (from both programs). Our results suggest that improvements in cavity heat transfer calculations can be obtained by using detailed radiation modeling (i.e. view-factor or ray-tracing models), and that incorporation of these strategies may be more important for improving the accuracy of results than the use of CFD modeling for horizontal cavities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

RF Cavities Loaded with Dielectric for Muon Facilities

This paper discusses RF cavities loaded with dielectric material that could be used in various muon collider facilities. Most of the existing pill-box cavity designs are too large in diameter to fit efficiently in the current cooling lattice designs. The paper describes novel compact dielectric loaded RF cavities designs that fit efficiently in muon cooling lattices and allow multi-frequency cavity designs in the same size cavity by changing the dielectric constant or size. The paper describes the designs of 400 and 800 MHz cavities for the (HCC) helical cooling channel. In addition to the use of the dielectric to reduce the radial size of gas-filled cavities in helical cooling channels, dielectric-loading has the potential use in vacuum cavities for suppression of dark current emission. Cavities that can be used for the phase rotation channel in the front end of a muon collider or neutrino factory are also presented.

43 PARTICLE ACCELERATORS↗

Image-Guided Radiotherapy for Breast Cancer Patients: Surgical Clips as Surrogate for Breast Excision Cavity

Purpose: To determine the use of surgical clips as a surrogate for localization of the excision cavity and to quantify the stability of the clips' positions during the course of external beam radiotherapy for breast cancer patients, using cone beam computed tomography (CBCT) scans. Methods and Materials: Twenty-one breast cancer patients with surgical clips placed in the breast excision cavity were treated in a supine position with 28 daily fractions. CBCT scans were regularly acquired for a setup correction protocol. Retrospectively, the CBCT scans were registered to the planning CT scans, using gray-value registration of the excision cavity region and chamfer matching of the clips. Subsequently, residual setup errors (systematic [{Sigma}] and random [{sigma}]) of the excision cavity were estimated relative to the clips' registration. Finally, the stability of the clips' positions were quantified as the movement of each separate clip according to the center of gravity of the excision cavity. Results: When clips were used for online setup corrections, the residual errors of the excision cavity were {Sigma}{sub left-right} = 1.2, {sigma}{sub left-right} = 1.0; {Sigma}{sub cranial-caudal} = 1.3, {sigma}{sub cranial-caudal} = 1.2; and {Sigma}{sub anterior-posterior} = 0.7, {sigma}{sub anterior-posterior} = 0.9 mm. Furthermore, the average distance (over all patients) between the clips and centers of gravity of the excision cavities was 18.8 mm (on the planning CT) and was reduced to 17.4 mm (measured on the last CBCT scan). Conclusion: Clips move in the direction of the center of gravity of the excision cavity, on average, 1.4 mm. The clips are good surrogates for locating the excision cavity and providing small residual errors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phonon-mediated squeezing of the cavity field off-resonantly coupled with a coherently driven quantum dot

We theoretically propose a scheme for the quadrature squeezing of the cavity field via dissipative processes. The effects of the electron-phonon interaction (EPI) on the squeezing are investigated, where the cavity is off-resonantly coupled with a coherently driven quantum dot (QD) which is allowed to interact with an acoustic-phonon reservoir. Under certain conditions, the participation of the phonon induced by both the EPI and the off-resonant coupling of the cavity with the QD enables some dissipative processes to occur resonantly in the dressed-state basis of the QD. The cavity-mode photons emitted or absorbed during the phonon-mediated dissipative processes are correlated, thus leading to the squeezing of the cavity field. A squeezed vacuum reservoir for the cavity field is built up due to the EPI plus the off-resonant coupling between the cavity and the QD. The numerical results obtained with an effective polaron master equation derived using second-order perturbation theory indicate that, in low temperature limit, the degree of squeezing is maximal but the increasing temperature of the phonon reservoir could hinder the squeezing and degrade the degree of the squeezing of the cavity field. In addition, the presence of the photonic crystal could enhance the quadrature squeezing of the cavity field.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Cavity morphology in a Ni based superalloy under heavy ion irradiation with cold pre-injected helium. I

In order to understand radiation damage in the nickel based superalloy Inconel X-750 in thermal reactors, where (n, α) transmutation reaction also occurred in addition to fast neutron induced atomic displacement, heavy ion (1 MeV Kr{sup 2+}) irradiation with pre-injected helium was performed under in-situ observations of an intermediate voltage electron microscope at Argonne National Laboratory. By comparing to our previous studies using 1 MeV Kr{sup 2+} irradiation solely, the pre-injected helium was found to be essential in cavity nucleation. Cavities started to be visible after Kr{sup 2+} irradiation to 2.7 dpa at ≥200 °C in samples containing 200 appm, 1000 appm, and 5000 appm helium, respectively, but not at lower temperatures. The cavity growth was observed during the continuous irradiation. Cavity formation appeared along with a reduced number density of stacking fault tetrahedra, vacancy type defects. With higher pre-injected helium amount, a higher density of smaller cavities was observed. This is considered to be the result of local trapping effect of helium which disperses vacancies. The average cavity size increases with increasing irradiation temperatures; the density reduced; and the distribution of cavities became heterogeneous at elevated temperatures. In contrast to previous characterization of in-reactor neutron irradiated Inconel X-750, no obvious cavity sink to grain boundaries and phase boundaries was found even at high doses and elevated temperatures. MC-type carbides were observed as strong sources for agglomeration of cavities due to their enhanced trapping strength of helium and vacancies.

36 MATERIALS SCIENCE↗

Plasma ignition and detection for in-situ cleaning of 1.3 GHz 9-cell cavities

Superconducting Radio Frequency (SRF) cavities performance preservation is crucial, from vertical test to accelerator operation. Field Emission (FE) is still one of the performance limiting factors to overcome and plasma cleaning has been proven successful by the Spallation Neutron Source (SNS), in cleaning field emitters and increasing the work function of Nb. A collaboration has been established between Fermi National Accelerator Laboratory (FNAL), SLAC National Accelerator Laboratory and Oak Ridge National Laboratory (ORNL) with the purpose of applying plasma processing to the Linac Coherent Light Source-II (LCLS-II) cavities, in order to minimize and overcome field emission without affecting the high Q of nitrogen-doped cavities. The cleaning for LCLS-II will follow the same plasma composition adopted at SNS, which allows in-situ processing of cavities installed in cryomodules from hydrocarbon contaminants. A novel method for plasma ignition has been developed at FNAL: a plasma glow discharge is ignited using high order modes to overcome limitations imposed by the fundamental power coupler, allowing in-situ cleaning for cavities in cryomodule. The plasma can be easily ignited and tuned in each of the cavity cells using low RF power. A method for plasma detection has been developed as well, which allows the detection of the plasma location in the cavity without the need of cameras at both cavity ends. The presented method can be applied to other multi-cell cavity designs, even for accelerators where the coupling for the fundamental modes at room temperature is very weak.

43 PARTICLE ACCELERATORS↗

Symmetrically tuned large-volume conic shell-cavities for axion searches

In an earlier paper [1], a new class of thin-shell cavities were proposed to evade the steep frequency scaling of conventional axion haloscopes. In this follow-up work, we see that a generalized conic geometry enables robust frequency-tuning for these large-volume cm-wave cavities. The frequency-defining dimension of a conic shell-cavity changes symmetrically and uniformly during tuning, maintaining a high axion coupling efficiency (the "form factor") to an external solenoid field. It is further shown that such tunable geometry is not restricted to circular cones. A general prescription for arbitrary volume-filling conic shell-cavities is developed and direct solutions are obtained for the created numerical models. Additionally, the largest of the realized designs is a meandering "brain" cavity that is tunable over a frequency range of 20%. The scan rate of this cavity is three orders of magnitude larger than that of a scaled cylindrical cavity used in the current generation experiments. The prospects for such a large improvement in the scan rate should motivate R& D efforts in fabrication and other implementation techniques. If these engineering challenges can be met, cavity-based axion haloscopes can stay competitive at frequencies higher than a few GHz. We propose an experimental configuration at 20 GHz (~80 μeV) using an array of brain cavities and compare it with other proposals for similar frequencies.

79 ASTRONOMY AND ASTROPHYSICS↗

Origins of quench in buffered chemical polished and low temperature baked SRF cavities

Electropolishing (EP) and buffered chemical polishing (BCP) are conventional surface preparation techniques for superconducting radiofrequency (SRF) cavities that remove damaged material from the cavity surface. One main issue with EP and BCP treated SRF cavities is high field Q-slope (HFQS), a drop in quality factor at high gradients that limits quench field. High gradient performance in EP cavities can be improved by applying a low temperature bake (LTB), but LTB does not consistently remove HFQS in BCP cavities. There is no consensus as to the why LTB is not effective on BCP prepared cavities, and the cause of HFQS in BCP cavities is not well understood. We examine the origins of quench in EP, BCP, EP+LTB, and BCP+LTB treated SRF cavities. We also show the effect of these treatments on the onset of HFQS, heating within the cavity up to quench, concentration of free hydrogen, and surface roughness.

43 PARTICLE ACCELERATORS↗

SRF Cavity Tuners for 3.9 GHz Cryomodules for LCLS-II Project

Fermilab conducted testing of three 3.9 GHz cryomodules for the LCLS-II project that will operate in continuous wave mode. A fast/fine tuning component was added to the LCLS-II 3.9 GHz tuner design due to the cavity bandwidth of 130 Hz which consists of two encapsulated piezos. Several cavities faced problems with fast-tuner operations after cooldown to 2 K and tuning the cavities to 3.9 GHz in cryomodule 2. All the piezo actuators were in working conditions but the slow tuner ranges required to stretch some of the cavities to the operational 3.9 GHz frequency were too small to deliver the required preload on the piezos. This behavior can be attributed to several factors: setting the initial warm cavity frequency during production too high, pressure tests of the warm cryomodule could have changed cavity frequency; and the small bending and twisting of the cavity-tuner system during the cooldown and warmup of the cavities. A decision was made to inelastically retune the warm cavities to decrease the unrestrained frequency by 200-300 kHz, this was done via the slow tuner. The results for this retuning method of three 3.9GHz cryomodules will be discussed.

43 PARTICLE ACCELERATORS↗

PRESERVATION OF THE HIGH QUALITY FACTOR AND ACCELERATING GRADIENT OF Nb3Sn-COATED CAVITY DURING PAIR ASSEMBLY

Two CEBAF 5-cell accelerator cavities have been coated with Nb3Sn film using the vapor diffusion technique. One cavity was coated in the Jefferson Lab Nb3Sn cavity coating system, and the other in the Fermilab Nb3Sn coating system. Both cavities were measured at 4 K and 2 K in the vertical dewar test in each lab and then assembled into a cavity pair at Jefferson Lab. Previous attempts to assemble Nb3Sn cavities into a cavity pair degraded the superconducting properties of Nb3Sn-coated cavities. This contribution discusses the efforts to identify and mitigate the pair assembly challenges and will present the results of the vertical tests before and after pair assembly. Notably, one of the cavities reached the highest gradient above 80 mT in the vertical test after the pair assembly.

Eremeev, G.V.↗

Superconducting Thin Films for The Enhancement of Superconducting Radio Frequency Accelerator Cavities

Bulk niobium (Nb) superconducting radio frequency (SRF) cavities are currently the preferred method for acceleration of charged particles at accelerating facilities around the world. However, bulk Nb cavities have poor thermal conductance, impose material and design restrictions on other components of a particle accelerator, have low reproducibility and are approaching the fundamental material-dependent accelerating field limit of approximately 50MV/m. Since the SRF phenomena occurs at surfaces within a shallow depth of ~1 μm, a proposed solution to this problem has been to utilize thin film technology to deposit superconducting thin films on the interior of cavities to engineer the active SRF surface in order to achieve cavities with enhanced properties and performance. Two proposed thin film applications for SRF cavities are: 1) Nb thin films coated on bulk cavities made of suitable castable metals (such as copper or aluminum) and 2) multilayer films designed to increase the accelerating gradient and performance of SRF cavities. While Nb thin films on copper (Cu) cavities have been attempted in the past using DC magnetron sputtering (DCMS), such cavities have never performed at the bulk Nb level. However, new energetic condensation techniques for film deposition, such as High Power Impulse Magnetron Sputtering (HiPIMS), offer the opportunity to create suitably thick Nb films with improved density, microstructure and adhesion compared to traditional DCMS. Clearly use of such novel technique requires fundamental studies to assess surface evolution and growth modes during deposition and resulting microstructure and surface morphology and the correlation with RF superconducting properties. Here we present detailed structure-property correlative research studies done on Nb/Cu thin films and NbN- and NbTiN-based multilayers made using HiPIMS and DCMS, respectively. Experiment Numbers:

Burton, Matthew↗

Simulation of Conduction Cooled SRF Cavity

SRF cavities are used heavily in high energy physics research, and simplifying operation of SRF cavities could enable their use in many fields of industry. Liquid helium coolant systems are a notable complexity of operating SRF cavities, and replacing liquid helium with cryocooler conduction cooling is an important research and development interest. As part of this effort, a system consisting of a 650 MHz single cell cavity, a commercial grade pulse tube refrigerator, and an aluminum thermal link was simulated through finite element analysis. The electromagnetic fields inside the cavity, heat flow through the system, and temperature distribution of the thermal link and cavity were calculated. Based on the simulations, the pulse tube refrigerator is capable of supplying adequate cooling power to a cavity with \ce{Nb3Sn} coating operating with an accelerating gradient between 6 and 12 MV/m. The maximum simulated temperature of the cavity was below 7 K, and the oscilla tions in temperature introduced by the pulse tube refrigerator were shown to dampen in amplitude before reaching the cavity surface.

43 PARTICLE ACCELERATORS↗