Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CALIBRATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Sensitivity of planetary cruise navigation to earth orientation calibration errors

A detailed analysis was conducted to determine the sensitivity of spacecraft navigation errors to the accuracy and timeliness of Earth orientation calibrations. Analyses based on simulated X-band (8.4-GHz) Doppler and ranging measurements acquired during the interplanetary cruise segment of the Mars Pathfinder heliocentric trajectory were completed for the nominal trajectory design and for an alternative trajectory with a longer transit time. Several error models were developed to characterize the effect of Earth orientation on navigational accuracy based on current and anticipated Deep Space Network calibration strategies. The navigational sensitivity of Mars Pathfinder to calibration errors in Earth orientation was computed for each candidate calibration strategy with the Earth orientation parameters included as estimated parameters in the navigation solution. In these cases, the calibration errors contributed 23 to 58% of the total navigation error budget, depending on the calibration strategy being assessed. Navigation sensitivity calculations were also performed for cases in which Earth orientation calibration errors were not adjusted in the navigation solution. In these cases, Earth orientation calibration errors contributed from 26 to as much as 227% of the total navigation error budget. The final analysis suggests that, not only is the method used to calibrate Earth orientation vitally important for precision navigation of Mars Pathfinder, but perhaps equally important is the method for inclusion of the calibration errors in the navigation solutions.

Estefan, J. A.↗

Calibration improvements to electronically scanned pressure systems and preliminary statistical assessment

Orifice-to-orifice inconsistencies in data acquired with an electronically-scanned pressure system at the beginning of a wind tunnel experiment forced modifications to the standard, instrument calibration procedures. These modifications included a large increase in the number of calibration points which would allow a critical examination of the calibration curve-fit process, and a subsequent post-test reduction of the pressure data. Evaluation of these data has resulted in an improved functional representation of the pressure-voltage signature for electronically-scanned pressures sensors, which can reduce the errors due to calibration curve fit to under 0.10 percent of reading compared to the manufacturer specified 0.10 percent of full scale. Application of the improved calibration function allows a more rational selection of the calibration set-point pressures. These pressures should be adjusted to achieve a voltage output which matches the physical shape of the pressure-voltage signature of the sensor. This process is conducted in lieu of the more traditional approach where a calibration pressure is specified and the resulting sensor voltage is recorded. The fifteen calibrations acquired over the two-week duration of the wind tunnel test were further used to perform a preliminary, statistical assessment of the variation in the calibration process. The results allowed the estimation of the bias uncertainty for a single instrument calibration; and, they form the precursor for more extensive and more controlled studies in the laboratory.

Everhart, Joel L.↗

Absolute Calibration of the AXAF Telescope Effective Area

The prelaunch calibration of AXAF encompasses many aspects of the telescope. In principle, all that is needed is the complete point response function. This is, however, a function of energy, off-axis angle of the source, and operating mode of the facility. No single measurement would yield the entire result. Also, any calibration made prior to launch will be affected by changes in conditions after launch, such as the change from one g to zero g. The reflectivity of the mirror and perhaps even the detectors can change as well, for example by addition or removal of small amounts of material deposited on their surfaces. In this paper, we give a broad view of the issues in performing such a calibration, and discuss how they are being addressed in prelaunch preparation of AXAF. As our title indicates, we concentrate here on the total throughput of the observatory. This can be thought of as the integral of the point response function, i.e. the encircled energy, out ot the largest practical solid angle for an observation. Since there is no standard x-ray source in the sky whose flux is known to the -1% accuracy we are trying to achieve, we must do this calibration on the ground. we also must provide a means for monitoring any possible changes in this calibration from pre-launch until on-orbit operation can transfer the calibration to a celestial x-ray source whose emission is stable. In this paper, we analyze the elements of the absolute throughput calibration, which we call Effective Area. We review the requirements for calibrations of components or subsystems of the AXAF facility, including mirror, detectors, and gratings. We show how it is necessary to calibrate this ground-based detection system at standard man-made x-ray sources, such as electron storage rings. We present the status of all these calibrations, with indications of the measurements remaining to be done, even though the measurements on the AXAF flight optics and detectors will have been completed by the time this paper is presented. We evaluate progress toward the goal of making 1% measurements of the absolute x-ray flux from astrophysical sources, so that comparisons can be made with their emission at other wavelengths, in support of observations such as the Sunyaev-Zeldovitch effect, which can give absolute distance measurements independent of the traditional distance measuring techniques in astronomy.

Kellogg, E.↗

High Altitude Measurements of Radiance at High Spectral and Spatial Resolution for SIMBIOS Sensor Calibration, Validation, and Intercomparisons

The successful combination of data from different ocean color sensors depends on the correct interpretation of signal from each of these sensors. Ideally, the sensor measured signals are calibrated to geophysical units of spectral radiance, and sensor artifacts are removed and corrected. The calibration process resamples the signal into a common radiometric data space so that subsequent ocean color algorithms that are applied to the data are based on physical processes and are inherently sensor independent. The objective of this project is to calibrate and validate the on-orbit radiometric characteristics of Sea-Viewing Wide Field-of-view Sensor (SeaWiFS) with underflights of NASA's calibrated Airborne Visible/Infrared Imaging Spectrometer (AVIRIS). This objective is feasible because AVIRIS measures the same spectral range as SeaWIFS at higher spectral resolution. In addition to satellite sensor underflights, the AVIRIS project has supported comparison and analysis of the radiometric calibration standards used for AVIRIS and SeaWIFS. To date, both the OCTS and SeaWIFS satellite sensors have been underflown by AVIRIS with matching spectral, spatial, geometric, radiometric, and temporal domains. The calibration and validation objective of this project is pursued for the following reasons: (1) Calibration is essential for the quantitative use of SeaWIFS and other SIMBIOS (Sensor Intercomparison and Merger for Biological and Interdisciplinary Oceanic Studies) sensor data; (2) Calibration in the laboratory of spaceborne sensors is challenging; (3) Satellite sensors are subjected aging on the ground and to trauma during launch; (4) The Earth orbit environment is significantly different than the laboratory calibration environment; (5) Through years of effort AVIRIS has been demonstrated to be well calibrated; and (6) AVIRIS can match the spectral and spatial observation characteristics near the top of the atmosphere at the time of SeaWIFS measurements.

Green, Robert O.↗

Optics-Only Calibration of a Neural-Net Based Optical NDE Method for Structural Health Monitoring

A calibration process is presented that uses optical measurements alone to calibrate a neural-net based NDE method. The method itself detects small changes in the vibration mode shapes of structures. The optics-only calibration process confirms previous work that the sensitivity to vibration-amplitude changes can be as small as 10 nanometers. A more practical value in an NDE service laboratory is shown to be 50 nanometers. Both model-generated and experimental calibrations are demonstrated using two implementations of the calibration technique. The implementations are based on previously published demonstrations of the NDE method and an alternative calibration procedure that depends on comparing neural-net and point sensor measurements. The optics-only calibration method, unlike the alternative method, does not require modifications of the structure being tested or the creation of calibration objects. The calibration process can be used to test improvements in the NDE process and to develop a vibration-mode-independence of damagedetection sensitivity. The calibration effort was intended to support NASA s objective to promote safety in the operations of ground test facilities or aviation safety, in general, by allowing the detection of the gradual onset of structural changes and damage.

Decker, Arthur J.↗

A Comparison of Two Balance Calibration Model Building Methods

Simulated strain-gage balance calibration data is used to compare the accuracy of two balance calibration model building methods for different noise environments and calibration experiment designs. The first building method obtains a math model for the analysis of balance calibration data after applying a candidate math model search algorithm to the calibration data set. The second building method uses stepwise regression analysis in order to construct a model for the analysis. Four balance calibration data sets were simulated in order to compare the accuracy of the two math model building methods. The simulated data sets were prepared using the traditional One Factor At a Time (OFAT) technique and the Modern Design of Experiments (MDOE) approach. Random and systematic errors were introduced in the simulated calibration data sets in order to study their influence on the math model building methods. Residuals of the fitted calibration responses and other statistical metrics were compared in order to evaluate the calibration models developed with different combinations of noise environment, experiment design, and model building method. Overall, predicted math models and residuals of both math model building methods show very good agreement. Significant differences in model quality were attributable to noise environment, experiment design, and their interaction. Generally, the addition of systematic error significantly degraded the quality of calibration models developed from OFAT data by either method, but MDOE experiment designs were more robust with respect to the introduction of a systematic component of the unexplained variance.

DeLoach, Richard↗

Revised Calibration Strategy for the CALIOP 532 nm Channel: Daytime - Part II

The CALIPSO lidar (CALIOP) makes backscatter measurements at 532 nm and 1064 nm and linear depolarization ratios at 532 nm. Accurate calibration of the backscatter measurements is essential in the retrieval of optical properties. An assessment of the nighttime 532 nm parallel channel calibration showed that the calibration strategy used for the initial release (Release 1) of the CALIOP lidar level 1B data was acceptable. In general, the nighttime calibration coefficients are relatively constant over the darkest segment of the orbit, but then change rapidly over a short period as the satellite enters sunlight. The daytime 532 nm parallel channel calibration scheme implemented in Release 1 derived the daytime calibration coefficients from the previous nighttime coefficients. A subsequent review of the daytime 532 nm parallel channel calibration revealed that the daytime calibration coefficients do not remain constant, but vary considerably over the course of the orbit, due to thermally-induced misalignment of the transmitter and receiver. A correction to the daytime calibration scheme is applied in Release 2 of the data. Results of both nighttime and daytime calibration performance are presented in this paper.

Powell, Kathleen A.↗

Landsat Data Continuity Mission Calibration and Validation

The primary payload for the Landsat Data Continuity Mission (LDCM) is the Operational Land Imager (OLI), being built by Ball Aerospace and Technologies, under contract to NASA. The OLI has spectral bands similar to the Landsat-7 ETM+, minus the thermal band and with two new bands, a 443 nm band and 1375 nm cirrus detection band. On-board calibration systems include two solar diffusers (routine and pristine), a shutter and three sets of internal lamps (routine, backup and pristine). Being a pushbroom opposed to a whiskbroom design of ETM+, the system poses new challenges for characterization and calibration, chief among them being the large focal plane with 75000+ detectors. A comprehensive characterization and calibration plan is in place for the instrument and the data throughout the mission including Ball, NASA and the United States Geological Survey, which will take over operations of LDCM after on-orbit commissioning. Driving radiometric calibration requirements for OLI data include radiance calibration to 5% uncertainty (1 q); reflectance calibration to 3% uncertainty (1 q) and relative (detector-to-detector) calibration to 0.5% (J (r). Driving geometric calibration requirements for OLI include bandto- band registration of 4.5 meters (90% confidence), absolute geodetic accuracy of 65 meters (90% CE) and relative geodetic accuracy of 25 meters (90% CE). Key spectral, spatial and radiometric characterization of the OLI will occur in thermal vacuum at Ball Aerospace. During commissioning the OLI will be characterized and calibrated using celestial (sun, moon, stars) sources and terrestrial sources. The USGS EROS ground processing system will incorporate an image assessment system similar to Landsat-7 for characterization and calibration. This system will have the added benefit that characterization data will be extracted as part of the normal image data processing, so that the characterization data available will be significantly larger than for Landsat-7 ETM+.

Markham, Brian L.↗

Photometric Calibration of Consumer Video Cameras

Equipment and techniques have been developed to implement a method of photometric calibration of consumer video cameras for imaging of objects that are sufficiently narrow or sufficiently distant to be optically equivalent to point or line sources. Heretofore, it has been difficult to calibrate consumer video cameras, especially in cases of image saturation, because they exhibit nonlinear responses with dynamic ranges much smaller than those of scientific-grade video cameras. The present method not only takes this difficulty in stride but also makes it possible to extend effective dynamic ranges to several powers of ten beyond saturation levels. The method will likely be primarily useful in astronomical photometry. There are also potential commercial applications in medical and industrial imaging of point or line sources in the presence of saturation.This development was prompted by the need to measure brightnesses of debris in amateur video images of the breakup of the Space Shuttle Columbia. The purpose of these measurements is to use the brightness values to estimate relative masses of debris objects. In most of the images, the brightness of the main body of Columbia was found to exceed the dynamic ranges of the cameras. A similar problem arose a few years ago in the analysis of video images of Leonid meteors. The present method is a refined version of the calibration method developed to solve the Leonid calibration problem. In this method, one performs an endto- end calibration of the entire imaging system, including not only the imaging optics and imaging photodetector array but also analog tape recording and playback equipment (if used) and any frame grabber or other analog-to-digital converter (if used). To automatically incorporate the effects of nonlinearity and any other distortions into the calibration, the calibration images are processed in precisely the same manner as are the images of meteors, space-shuttle debris, or other objects that one seeks to analyze. The light source used to generate the calibration images is an artificial variable star comprising a Newtonian collimator illuminated by a light source modulated by a rotating variable neutral- density filter. This source acts as a point source, the brightness of which varies at a known rate. A video camera to be calibrated is aimed at this source. Fixed neutral-density filters are inserted in or removed from the light path as needed to make the video image of the source appear to fluctuate between dark and saturated bright. The resulting video-image data are analyzed by use of custom software that determines the integrated signal in each video frame and determines the system response curve (measured output signal versus input brightness). These determinations constitute the calibration, which is thereafter used in automatic, frame-by-frame processing of the data from the video images to be analyzed.

Suggs, Robert↗

Simplified Vicarious Radiometric Calibration

A measurement-based radiance estimation approach for vicarious radiometric calibration of spaceborne multispectral remote sensing systems has been developed. This simplified process eliminates the use of radiative transfer codes and reduces the number of atmospheric assumptions required to perform sensor calibrations. Like prior approaches, the simplified method involves the collection of ground truth data coincident with the overpass of the remote sensing system being calibrated, but this approach differs from the prior techniques in both the nature of the data collected and the manner in which the data are processed. In traditional vicarious radiometric calibration, ground truth data are gathered using ground-viewing spectroradiometers and one or more sun photometer( s), among other instruments, located at a ground target area. The measured data from the ground-based instruments are used in radiative transfer models to estimate the top-of-atmosphere (TOA) target radiances at the time of satellite overpass. These TOA radiances are compared with the satellite sensor readings to radiometrically calibrate the sensor. Traditional vicarious radiometric calibration methods require that an atmospheric model be defined such that the ground-based observations of solar transmission and diffuse-to-global ratios are in close agreement with the radiative transfer code estimation of these parameters. This process is labor-intensive and complex, and can be prone to errors. The errors can be compounded because of approximations in the model and inaccurate assumptions about the radiative coupling between the atmosphere and the terrain. The errors can increase the uncertainty of the TOA radiance estimates used to perform the radiometric calibration. In comparison, the simplified approach does not use atmospheric radiative transfer models and involves fewer assumptions concerning the radiative transfer properties of the atmosphere. This new technique uses two neighboring uniform ground target areas having different reflectance values. The target areas can be natural or artificial and must be large enough to minimize adjacent-pixel contamination effects. The radiative coupling between the atmosphere and the terrain needs to be approximately the same for the two targets. This condition can be met for relatively uniform backgrounds when the distance between the targets is within a few hundred meters. For each target area, the radiance leaving the ground in the direction of the satellite is measured with a radiometrically calibrated spectroradiometer. Using the radiance measurements from the two targets, atmospheric adjacency and atmospheric scattering effects can be subtracted, thereby eliminating many assumptions about the atmosphere and the radiative interaction between the atmosphere and the terrain. In addition, the radiometrically calibrated spectroradiometer can be used with a known reflectance target to estimate atmospheric transmission and diffuse- to-global ratios without the need for ancillary sun photometers. Several comparisons between the simplified method and traditional techniques were found to agree within a few percent. Hence, the simplified method reduces the overall complexity of performing vicarious calibrations and can serve as a method for validating traditional radiative transfer models

Stanley, Thomas↗

Twenty-Five Years of Landsat Thermal Band Calibration

Landsat-7 Enhanced Thematic Mapper+ (ETM+), launched in April 1999, and Landsat-5 Thematic Mapper (TM), launched in 1984, both have a single thermal band. Both instruments thermal band calibrations have been updated previously: ETM+ in 2001 for a pre-launch calibration error and TM in 2007 for data acquired since the current era of vicarious calibration has been in place (1999). Vicarious calibration teams at Rochester Institute of Technology (RIT) and NASA/Jet Propulsion Laboratory (JPL) have been working to validate the instrument calibration since 1999. Recent developments in their techniques and sites have expanded the temperature and temporal range of the validation. The new data indicate that the calibration of both instruments had errors: the ETM+ calibration contained a gain error of 5.8% since launch; the TM calibration contained a gain error of 5% and an additional offset error between 1997 and 1999. Both instruments required adjustments in their thermal calibration coefficients in order to correct for the errors. The new coefficients were calculated and added to the Landsat operational processing system in early 2010. With the corrections, both instruments are calibrated to within +/-0.7K.

Barsi, Julia A.↗

Calibrated Noise Measurements with Induced Receiver Gain Fluctuations

The lack of well-developed techniques for modeling changing statistical moments in our observations has stymied the application of stochastic process theory in science and engineering. These limitations were encountered when modeling the performance of radiometer calibration architectures and algorithms in the presence of non stationary receiver fluctuations. Analyses of measured signals have traditionally been limited to a single measurement series. Whereas in a radiometer that samples a set of noise references, the data collection can be treated as an ensemble set of measurements of the receiver state. Noise Assisted Data Analysis is a growing field of study with significant potential for aiding the understanding and modeling of non stationary processes. Typically, NADA entails adding noise to a signal to produce an ensemble set on which statistical analysis is performed. Alternatively as in radiometric measurements, mixing a signal with calibrated noise provides, through the calibration process, the means to detect deviations from the stationary assumption and thereby a measurement tool to characterize the signal's non stationary properties. Data sets comprised of calibrated noise measurements have been limited to those collected with naturally occurring fluctuations in the radiometer receiver. To examine the application of NADA using calibrated noise, a Receiver Gain Modulation Circuit (RGMC) was designed and built to modulate the gain of a radiometer receiver using an external signal. In 2010, an RGMC was installed and operated at the National Institute of Standards and Techniques (NIST) using their Noise Figure Radiometer (NFRad) and national standard noise references. The data collected is the first known set of calibrated noise measurements from a receiver with an externally modulated gain. As an initial step, sinusoidal and step-function signals were used to modulate the receiver gain, to evaluate the circuit characteristics and to study the performance of a variety of calibration algorithms. The receiver noise temperature and time-bandwidth product of the NFRad are calculated from the data. Statistical analysis using temporal-dependent calibration algorithms reveals that the natural occurring fluctuations in the receiver are stationary over long intervals (100s of seconds); however the receiver exhibits local non stationarity over the interval over which one set of reference measurements are collected. A variety of calibration algorithms have been applied to the data to assess algorithms' performance with the gain fluctuation signals. This presentation will describe the RGMC, experiment design and a comparative analysis of calibration algorithms.

Racette, Paul↗

Radiometric Model and Inter-Comparison Results of the SGLI-VNR On-Board Calibration

The Second Generation Global Imager (SGLI) on Global Change Observation Mission– Climate (GCOM-C) satellite empowers surface and atmospheric measurements related to the carbon cycle and radiation budget, with two radiometers of Visible and Near Infrared Radiometer (SGLI-VNR) and Infrared Scanning Radiometer (SGLI-IRS) that perform a wide-band (380 nm–12 µm) optical observation not only with as wide as a 1150–1400 km field of view (FOV), but also with as high as 0.25–0.5 km resolution. Additionally, polarization and along-track slant view observations are quite characteristic of SGLI. It is important to calibrate radiometers to provide the sensor data records for more than 28 standard products and 23 research products including clouds, aerosols, ocean color, vegetation, snow and ice, and other applications. In this paper, the radiometric model and the first results of on-board calibrations on the SGLI-VNR, which include weekly solar and light-emitting diode (LED) calibration and monthly lunar calibration, will be described. Each calibration data was obtained with corrections, where beta angle correction and avoidance of reflection from multilayer insulation (MLI) were applied for solar calibration; LED temperature correction was performed for LED calibration; and the GIRO (GSICS (Global Space-based Inter-Calibration System) Implementation of the ROLO (RObotic Lunar Observatory) model) model was used for lunar calibration. Results show that the inter-comparison of the relative degradation amount between these three calibrations agreed to within 1% or less.

Urabe, Tomoyuki↗

Derivation of the final OSIRIS-REx OVIRS in-flight radiometric calibration

The OSIRIS-REx Visible and InfraRed Spectrometer (OVIRS) operates over the ∼0.4- to 4.3-μm wavelength range. Radiometric calibration over this broad range requires the use of multiple calibration sources. Initial OVIRS in-flight calibration coefficients were previously computed using ground calibration from visible integrating sphere and IR blackbody sources, cross-calibrated with Earth-observing satellites for visible wavelengths, and adjusted using the spectrum of the OSIRIS-REx mission’s target body, asteroid (101955) Bennu. As part of the final in-flight calibration, we determined that the best calibration method removes out-of-band IR signal leakage prior to radiometric calibration and updated the calibration coefficients accordingly. These final calibration coefficients work well for data where the field of view is filled, and we document the possible artifacts in underfilled spots.

Amy A. Simon↗

MODIS Reflective Solar Band Calibration Improvements using Pseudo-Invariant Desert Targets

To provide the best science data quality, an accurate characterization of the response versus scan angle (RVS) function is critical for the MODIS reflective solar bands (RSB) on-orbit calibration. In every MODIS operational scan, the Earth’s surface, referred to here as Earth view (EV), the space view (SV) port, and the onboard calibrators are viewed via a two-sided scan mirror. The RVS is defined as the sensor’s relative response as a function the angle of incidence (AOI) to the scan mirror. Many different approaches have been developed to derive the time-dependent RVS and its look-up table (LUT) applied to MODIS Level 1B (L1B) products since calibration Collection 4. For most MODIS RSB, the on-board calibrators can reasonably track the RVS change with time. In practice, their RVS is derived using data from on-board calibrators and the EV mirror side ratio (for mirror side 2). For Terra bands 1-4, 8-10 and Aqua bands 1-4, 8-9, an enhancement has been employed in Collections 6 and 6.1 (C6/C6.1) by using Earth scene response trending from pseudo-invariant desert sites in addition to the onboard calibrators. The current C6/C6/1 RVS algorithm is focused on fitting the EV data at each AOI over time and then deriving the relative change at different AOI. The EV response trending is currently fitted with multiple segments over time. Alternatively, the EV responses can be fit first as a function of AOI before fitting temporally in order to reduce the dependence on the stability of the desert site. These pre-treatment methods on the EV data provide improvement in the derived calibration coefficients. However, evidence of insufficient calibration is still observed in the MODIS L1B reflectance data, especially in the form of differences between the mirror sides. In this paper, we review the current methodologies that utilize the EV response trends from the pseudo-invariant Libyan desert targets to supplement the gain derived from the onboard calibrators. An improvement is then proposed and investigated such that a sliding window average (SWA) is used to pre-process the raw EV data. The SWA parameters are carefully selected using trade-off studies to accurately track the Earth scene response trending in multiple cases to overcome the reflectance differences between two mirror sides. Calibration results show improvements for both Aqua and Terra MODIS RSB L1B data products. This new adjustment has been included in the recently delivered Collection 7 LUT that will be evident in the L1B products expected to be released in late 2021.

MODIS↗

Calibration and Validation of the SHERLOC Instrument Operating in Jezero Crater, Mars

The Scanning Habitable Environments with Raman and Luminescence for Organics and Chemistry (SHERLOC) is an instrument onboard the Mars 2020 Perseverance rover. It consists of a spectrometer that measures deep ultraviolet (DUV) resonance Raman and native fluorescence photons generated through surface interactions with a 248.6 nm pulsed laser. Two microscopic imagers, the Autofocus Context Imager (ACI) and the Wide-Angle Topographic Sensor for Operations and eNgineering (WATSON), provide high-resolution context images of SHERLOC targets. The ACI is co-boresighted with the spectrometer. To ensure proper calibration, the SHERLOC calibration target (SCT) is mounted on the front of the rover and consists of ten different materials. The SCT was designed, fabricated, assembled, and tested by Jacobs Technology, Inc., and NASA Johnson Space Center. The dimensions of the calibration target housing are 150 x 89 x 33 mm and it weighs ~437 g. The ten targets are arranged in two rows; the first six are hard targets (AlGaN for Raman and fluorescence, diffuse transmission target, a slice of the SaU008 Mars meteorite, an intensity maze, and polycarbonate over geocache coin) and the remaining four are soft-goods targets (Vectran, Ortho-Fabric, Teflon, and nGimat-coated Teflon). The hard targets calibrate the spectrometer’s Raman and fluorescence spectral accuracy, ambient light reflection, and Raman response curve, while the soft-goods targets are spacesuit materials that function as human exploration targets, some of which are also used for spectral calibration. SHERLOC also has an internal calibration target consisting of AlGaN on sapphire (275 nm) located inside the ACI opaque dust cover to ensure proper instrument functioning between calibration target analyses. Initial SHERLOC, ACI, and WATSON calibration and validation on Mars was performed using the internal calibration target on sols 59, 83, 98, and 141; WATSON imaging of the SCT on sols 26 and 62, and SHERLOC spectroscopy and ACI imaging of the SCT on sol 59. These early data provide initial insights into instrument performance and the stability and degradation of the calibration target materials relative to the Martian surface and dust environment. Early observations also have implications for future astronaut spacesuit materials.

Trevor G Graff↗

Calibration Inter-Comparison of MODIS and VIIRS Reflective Solar Bands Using Lunar Observations

Multispectral band observations from Terra and Aqua MODIS, launched in December 1999 and May 2002, respectively, and from SNPP and NOAA-20 VIIRS, launched in November 2011 and October 2017, respectively, have continuously enabled a broad range of applications and studies of the Earth system and its changes via a set of geophysical and environmental parameters. The quality of MODIS and VIIRS science and environmental data products relies strongly on the calibration accuracy and stability of individual sensors, as well as their calibration consistency, especially for the data products generated using observations from sensors across different platforms. Both MODIS and VIIRS instruments carry a similar set of on-board calibrators for their on-orbit calibration. Besides, lunar observations are regularly scheduled and implemented in support of their reflective solar bands (RSB) calibration, especially their long-term stability monitoring. In this paper, we provide an overview of MODIS and VIIRS solar and lunar calibration methodologies applied for the RSB on-orbit calibration, and describe the approach developed for their calibration inter-comparisons using lunar observations, including corrections for the effects caused by differences in the relative spectral response and adopted solar spectra between individual sensors. The MODIS and VIIRS calibration inter-comparison results derived from their regularly scheduled lunar observations are presented and discussed, including associated uncertainties and a comparison with those derived using the Earth-view targets. Also discussed are remaining challenges in lunar calibration and inter-comparison for the Earth-observing sensors, as well as on-going efforts for future improvements.

Multispectral band↗

Using DSCOVR EPIC as an Additional Calibration Reference to Radiometrically Scale the Geo Imagers for the NASA CERES Project

The NASA CERES project provides climate-quality observed TOA and calculated surface fluxes to the climate community. The CERES instruments are mounted on the Aqua, Terra, NPP, and NOAA-20 low earth orbiting (LEO) satellites, where they are used alongside the VIIRS and MODIS based cloud properties necessary for converting CERES radiance observations into fluxes. The CERES SYN1deg product provides the regional hourly fluxes in between the Terra and Aqua/NOAA-20-CERES observations based on geostationary imager (GEO) radiances. The GEO radiances are radiometrically scaled to the MODIS or VIIRS calibration references. The GEO and MODIS inter-calibration events are limited by the Aqua-MODIS or VIIRS local equator crossing time of 1:30 PM. The DSCOVR satellite orbits the Lagrange-1 (L1) point about 1.5 million kilometers from Earth, and the Earth Polychromatic Imaging Camera (EPIC) instrument onboard DSCOVR has a constant view of the sunlit side of the Earth while taking images ranging from the UV to the NIR throughout the day. While the EPIC sensor has no onboard calibration systems, multiple inter-calibration studies have indicated that EPIC is radiometrically stable, which allows it to potentially be used as a transfer radiometer between imagers. This study will assess the viability of using EPIC as a consistent and stable calibration source for GEO imagers. EPIC will be inter-calibrated with Himawari-8 that has been radiometrically scaled with Aqua. The Himawari-8 based EPIC calibration gains will be verified by the EPIC calibration gains determined directly from Aqua-MODIS matches. The EPIC calibration gains based on Himawari-8 will be stratified by local time to determine any diurnal dependence of the GEO/EPIC calibration strategy.

C O Haney↗