Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CAD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Towards understanding the formation of internal fragments generated by collisionally activated dissociation for top-down mass spectrometry

Top-down mass spectrometry (TD-MS) generates fragment ions that returns information on the polypeptide amino acid sequence. In addition to terminal fragments, internal fragments that result from multiple cleavage events can also be formed. Traditionally, internal fragments are largely ignored due to a lack of available software to reliably assign them, mainly caused by a poor understanding of their formation mechanism. To accurately assign internal fragments, their formation process needs to be better understood. Here we applied a statistical method to compare fragmentation patterns of internal and terminal fragments of peptides and proteins generated by collisionally activated dissociation (CAD). Internal fragments share similar fragmentation propensities with terminal fragments (e.g., enhanced cleavages N-terminal to proline and C-terminal to acidic residues), suggesting that their formation follows conventional CAD pathways. Internal fragments should be generated by subsequent cleavages of terminal fragments and their formation can be explained by the well-known mobile proton model. Additionally, internal fragments can be coupled with terminal fragments to form complementary product ions that span the entire protein sequence. These enhance our understanding of internal fragment formation and can help improve sequencing algorithms to accurately assign internal fragments, which will ultimately lead to more efficient and comprehensive TD-MS analysis of proteins and proteoforms.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Particle tracking acceleration via signed distance fields in direct-accelerated geometry Monte Carlo

Computer-aided design (CAD)-based Monte Carlo radiation transport is of value to the nuclear engineering community for its ability to conduct transport on high-fidelity models of nuclear systems, but it is more computationally expensive than native geometry representations. This work describes the adaptation of a rendering data structure, the signed distance field, as a geometric query tool for accelerating CAD-based transport in the direct-accelerated geometry Monte Carlo toolkit. Demonstrations of its effectiveness are shown for several problems. The beginnings of a predictive model for the data structure's utilization based on various problem parameters is also introduced.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Robust Containment Queries over Collections of Trimmed NURBS Surfaces via Generalized Winding Numbers

Here, we propose a containment query that is robust to the watertightness of regions bound by trimmed NURBS surfaces, as this property is difficult to guarantee for in-the-wild CAD models. Containment is determined through the generalized winding number (GWN), a mathematical construction that is indifferent to the arrangement of surfaces in the shape. Applying contemporary techniques for the 3D GWN to trimmed NURBS surfaces requires some form of geometric discretization, introducing computational inefficiency to the algorithm and even risking containment misclassifications near the surface. In contrast, our proposed method leverages properties of the 3D solid angle to solve the relevant surface integral using a boundary formulation with rapidly converging adaptive quadrature. Batches of queries are further accelerated by memoizing (i.e., caching and reusing) quadrature node positions and tangents as they are evaluated. We demonstrate that our GWN method is robust to complex trimming geometry in a CAD model, and is accurate up to arbitrary precision at arbitrary distances from the surface. The derived containment query is therefore robust to model non-watertightness while respecting all curved features of the input shape.

97 MATHEMATICS AND COMPUTING↗

TEAMER: Results of Investigating Structural Design Concepts and Alternative Materials for a Wave Power System

Included here are materials from a study on the design of a three-body Wave Energy Converter (WEC) utilizing a heave plate, dual Power Take Offs (PTOs), and single point mooring. A material trade study has been conducted to evaluate the effects of introducing various metallic and fiber-reinforced polymer (FRP) elements to the design. The baseline design is C-Power's patented k2 Wave Power System (WPS). This Testing Expertise and Access for Marine Energy Research (TEAMER) Request for Technical Support (RFTS) 9 effort resulted in alternative designs of the WPS center member, the nacelle. The analysis resulting from this study will inform the design of a lightweight structure with lower manufacturing and operating costs that increases energy conversion and power-to-weight ratio of the device. The dataset contains several components: finite element analysis (FEA) data, hand calculations, and CAD models. FEA files includes those used for and generated by finite element simulations. Calculations include hand calculations performed using Microsoft Excel, which assess core laminate properties, buckling, and other structural aspects in accordance with risk management DNV-RP-C201 standards. CAD materials include Solidworks files for parts, assemblies, and drawings of the evaluated models.

16 TIDAL AND WAVE POWER↗

Design for Remanufacturing

The objective of this project was to develop relationships between published scholarship, industry experience, and remanufacturing design rules and identify a clear path for integrating remanufacturing design rules into CAD tools and design practices. To accomplish this, remanufacturing knowledge was compiled, and then the relationships between this knowledge and a prioritized set of product design guidelines was developed. Next, a process to create rules out of guidelines was developed by first defining life extension as a primary function, and remanufacturing as effective tasks to control the failure modes that would restrict the product life. The reliability centered maintenance (RCM) process was used to identify proactive tasks and default actions to mitigate the effects of failure modes. These tasks were developed into expert system rules. The impact of design on remanufacturing was then validated through implementing a prioritized set of design rules for a Heavy Duty Off-Road (HDOR) techno-economic case study. Finally, detailed steps on how to define, develop, and integrate these rules into CAD were created.

42 ENGINEERING↗

Conceptual Design of a Test Section for a Cryogenic Transfer Line Experiment

This project presents the development of a comprehensive computer-aided design (CAD) model for the Transfer Line test section, which is an upcoming test module for the Flow Boiling and Condensation Experiment (FBCE) aboard the International Space Station. The FBCE aims to serve as the primary platform to study two-phase flow in microgravity, and the Transfer Line module aims to utilize its existing hardware to study cryogenic chilldown; a critical component of cryogenic propellant transfer in space. The CAD model was created using SolidWorks software and includes the test section’s main components: a heat transfer line, a flow visualization line, insulation, high-speed visible imaging, and infrared imaging. The heat transfer line primarily consists of a stainless steel tube that will be heated via Joule heating. The flow visualization line consists of segmented Indium-Titanium-Oxide coated sapphire tubes, which allow for visualization of flow regimes by high-speed and infrared cameras, similar thermal properties as the stainless steel tube, and Joule heating via the ITO coating resistance. Polyether Ether Ketone was used to insulate and encapsulate the two sections. High-speed visible imaging and infrared imaging were also incorporated to view the propagation of fluid during inverted annular flow and map out the thermal profile of the ITO-coated sapphire tube. This model serves as the guiding concept design for the Transfer Line project and will assist the project team during future safety reviews and concept design reviews. Overall, this work is significant in two-phase flow research and offers a promising path towards an established facility for cryogenic transfer line research in microgravity.

Flow boiling↗

A Fundamental Tandem Mass Spectrometry Study of the Collision‐Activated Dissociation of Small Deprotonated Molecules Related to Lignin

AbstractThe collision‐activated fragmentation pathways and reaction mechanisms of 34 deprotonated model compounds representative of lignin degradation products were explored experimentally and computationally. The compounds were evaporated and ionized by using negative‐ion mode electrospray ionization doped with NaOH to produce abundant deprotonated molecules. The ions were isolated and subjected to collision‐activated dissociation (CAD). Their fragment ions were then isolated and also subjected to CAD. This was repeated until no further fragmentation was observed (up to MS6). This approach enabled the identification of characteristic reaction pathways and delineation of reasonable fragmentation mechanisms for deprotonated molecules containing various functional groups. The varying fragmentation patterns observed for different types of compounds allow for the identification of the functionalities in these compounds. This information was utilized to identify the presence of specific functionalities and their combinations in molecules in an organosolv lignin sample.

catalysis (homogeneous), catalysis (heterogeneous)↗

Yet another parameter-free shape optimization method

The use of node coordinates as design variables in shape optimization offers a larger design space than computer-aided design (CAD)-based shape parameterizations. It also allows for the optimization of legacy designs, i.e., a finite element mesh from an existing design can be readily optimized to meet new performance requirements without involving a CAD model. However, it is well known that the node coordinate parameterization method is fraught with numerical difficulties, which makes it impractical to use. This has led to several of “parameter-free” shape optimization methods that seek the advantages and avoid the pitfalls of the naïve node coordinate parameterization method. These methods come in two main varieties: sensitivity filtering (or gradient smoothing) and consistent filtering. The latter is analogous to the density filter method used in topology optimization (TO). In this work, we use the PDE filter from TO and energy-based filters to implement consistent shape optimization filtering schemes easily and efficiently. Numerical experiments demonstrate that consistent methods are more robust than sensitivity filtering methods.

42 ENGINEERING↗

Computer-Assisted Diagnosis System for Breast Cancer in Computed Tomography Laser Mammography (CTLM)

Computed tomography laser mammography (Eid et al. Egyp J Radiol Nucl Med, 37(1): p. 633–643, 1) is a non-invasive imaging modality for breast cancer diagnosis, which is time-consuming and challenging for the radiologist to interpret the images. Some issues have increased the missed diagnosis of radiologists in visual manner assessment in CTLM images, such as technical reasons which are related to imaging quality and human error due to the structural complexity in appearance. The purpose of this study is to develop a computer-aided diagnosis framework to enhance the performance of radiologist in the interpretation of CTLM images. The proposed CAD system contains three main stages including segmentation of volume of interest (VOI), feature extraction and classification. A 3D Fuzzy segmentation technique has been implemented to extract the VOI. The shape and texture of angiogenesis in CTLM images are significant characteristics to differentiate malignancy or benign lesions. The 3D compactness features and 3D Grey Level Co-occurrence matrix (GLCM) have been extracted from VOIs. Multilayer perceptron neural network (MLPNN) pattern recognition has developed for classification of the normal and abnormal lesion in CTLM images. The performance of the proposed CAD system has been measured with different metrics including accuracy, sensitivity, and specificity and area under receiver operative characteristics (AROC), which are 95.2, 92.4, 98.1, and 0.98%, respectively.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Coronary Artery Disease and Coronary Anomalies with a Handheld Smartphone

The purpose of this study was to determine the diagnostic accuracy of an iPhone for evaluation of the coronary arteries on coronary CT angiography (CTA) in comparison to a standard clinical workstation. Fifty coronary CTA exams were selected to include a range of normal and abnormal cases including both coronary artery disease (CAD) of varying severity and coronary artery anomalies. Two cardiac radiologists reviewed each exam on a standard clinical workstation initially and then on an iPhone 6 after a washout period. Coronary stenosis was evaluated on a 4-point scale and presence of coronary anomalies was recorded. Two additional cardiac radiologists reviewed all cases in consensus on the standard workstation and these results were used as the reference standard. When reader results were compared to the reference standard, there was no significant difference in agreement for per-vessel stenosis scores using either the iPhone or standard clinical workstation. The intraobserver intertechnology agreement on a per-vessel basis for obstructive CAD were 97.4% (299/307, kappa = 0.777) and 97.5% (317/325, kappa = 0.804) for the two readers. All cases of coronary anomalies were identified by both readers regardless of the device used. Coronary CTA examinations can be interpreted on a smartphone with diagnostic accuracy comparable to a standard workstation. 3D visualization app on the iPhone may facilitate urgent coronary CTA review when a workstation is not available.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MABAL: a Novel Deep-Learning Architecture for Machine-Assisted Bone Age Labeling

Bone age assessment (BAA) is a commonly performed diagnostic study in pediatric radiology to assess skeletal maturity. The most commonly utilized method for assessment of BAA is the Greulich and Pyle method (Pediatr Radiol 46.9:1269–1274, 2016; Arch Dis Child 81.2:172–173, 1999) atlas. The evaluation of BAA can be a tedious and time-consuming process for the radiologist. As such, several computer-assisted detection/diagnosis (CAD) methods have been proposed for automation of BAA. Classical CAD tools have traditionally relied on hard-coded algorithmic features for BAA which suffer from a variety of drawbacks. Recently, the advent and proliferation of convolutional neural networks (CNNs) has shown promise in a variety of medical imaging applications. There have been at least two published applications of using deep learning for evaluation of bone age (Med Image Anal 36:41–51, 2017; JDI 1–5, 2017). However, current implementations are limited by a combination of both architecture design and relatively small datasets. The purpose of this study is to demonstrate the benefits of a customized neural network algorithm carefully calibrated to the evaluation of bone age utilizing a relatively large institutional dataset. In doing so, this study will aim to show that advanced architectures can be successfully trained from scratch in the medical imaging domain and can generate results that outperform any existing proposed algorithm. The training data consisted of 10,289 images of different skeletal age examinations, 8909 from the hospital Picture Archiving and Communication System at our institution and 1383 from the public Digital Hand Atlas Database. The data was separated into four cohorts, one each for male and female children above the age of 8, and one each for male and female children below the age of 10. The testing set consisted of 20 radiographs of each 1-year-age cohort from 0 to 1 years to 14–15+ years, half male and half female. The testing set included left-hand radiographs done for bone age assessment, trauma evaluation without significant findings, and skeletal surveys. A 14 hidden layer-customized neural network was designed for this study. The network included several state of the art techniques including residual-style connections, inception layers, and spatial transformer layers. Data augmentation was applied to the network inputs to prevent overfitting. A linear regression output was utilized. Mean square error was used as the network loss function and mean absolute error (MAE) was utilized as the primary performance metric. MAE accuracies on the validation and test sets for young females were 0.654 and 0.561 respectively. For older females, validation and test accuracies were 0.662 and 0.497 respectively. For young males, validation and test accuracies were 0.649 and 0.585 respectively. Finally, for older males, validation and test set accuracies were 0.581 and 0.501 respectively. The female cohorts were trained for 900 epochs each and the male cohorts were trained for 600 epochs. An eightfold cross-validation set was employed for hyperparameter tuning. Test error was obtained after training on a full data set with the selected hyperparameters. Using our proposed customized neural network architecture on our large available data, we achieved an aggregate validation and test set mean absolute errors of 0.637 and 0.536 respectively. To date, this is the best published performance on utilizing deep learning for bone age assessment. Our results support our initial hypothesis that customized, purpose-built neural networks provide improved performance over networks derived from pre-trained imaging data sets. We build on that initial work by showing that the addition of state-of-the-art techniques such as residual connections and inception architecture further improves prediction accuracy. This is important because the current assumption for use of residual and/or inception architectures is that a large pre-trained network is required for successful implementation given the relatively small datasets in medical imaging. Instead we show that a small, customized architecture incorporating advanced CNN strategies can indeed be trained from scratch, yielding significant improvements in algorithm accuracy. It should be noted that for all four cohorts, testing error outperformed validation error. One reason for this is that our ground truth for our test set was obtained by averaging two pediatric radiologist reads compared to our training data for which only a single read was used. This suggests that despite relatively noisy training data, the algorithm could successfully model the variation between observers and generate estimates that are close to the expected ground truth.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Non-invasive Risk Stratification for Coronary Artery Disease: Is It Time for Subclassifications?

Purpose of Review: Coronary artery disease (CAD) is the leading contributor to cardiovascular disease; it is the most prevalent non-communicable disease globally and has high morbidity, mortality and health care cost. Risk stratification is defined as prevention or containment of disease prior to it occurring or progressing, and non-invasive surrogates include history, examination, biomarkers and non-invasive imaging. This review aims to highlight advancement in current diagnostic strategies and explores gaps for CAD secondary to atherosclerosis and non-obstructive vascular diseases. Recent Findings: Cardiac risk scores have largely proven inadequate in risk stratifying heterogeneous patient populations. Greater emphasis should also be provided to posttest risk stratification. Non-invasive imaging with MRI is the most accurate but least cost efficacious presently due to availability and expertise. Echocardiography and nuclear imaging have good accuracy, but radiation limits the latter. Novel echocardiographic technologies may increase its appeal. Cardiac CT angiography is increasingly promising. Summary: Non-invasive and minimally invasive imaging has significantly influenced the cost-efficacy trajectory of coronary artery disease diagnosis and management. Recent studies suggest that future guidelines will incorporate more subclassifications from the findings of these novel technologies and for more diverse patient demographics.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of imaging protocol on left ventricular ejection fraction using gated-SPECT myocardial perfusion imaging

Background: There are limited data on the impact of the imaging protocol (single-day stress-rest, SD, vs. dual-day, DD) on the change in left ventricular (LV) ejection fraction (EF) (post-stress-rest) in relation to ischemia and on outcome. Methods: Using propensity score matching procedure, 490 of 1121 patients with known CAD, undergoing a SD or a DD in a multicenter study, were evaluated. Stress and rest gated-SPECT myocardial perfusion imaging was used to quantify LV perfusion, EF, and volumes. Outcome was assessed at an average follow-up time of 3.2 years. Results: Post-stress LVEF in SD and DD were comparable across all degrees of ischemia. The change in LVEF in patients with severe ischemia was, however, higher in the DD protocol, independent of the extent of CAD. At follow-up, 240 patients (49.0%) required coronary revascularization (CR) and 52 patients (10.6%) had hard events. The ischemic burden was independently associated with CR and hard-events; the post-stress LVEF was associated with CR but the change in EF was not predictive of either CR or hard events. Conclusions: In patients with severe ischemia, underestimation of post-stress myocardial stunning could be observed with the SD protocol. Post-stress LVEF and the extent ischemia, but not the change in EF, are predictive of CR and hard events.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Complete revascularization determined by myocardial perfusion imaging could improve the outcomes of patients with stable coronary artery disease, compared with incomplete revascularization and no revascularization

Objectives: To compare the outcomes among patients treated by complete coronary revascularization (CCR) or incomplete coronary revascularization (ICR) and no coronary revascularization (NCR) by myocardial perfusion imaging (MPI), as well as to evaluate the impact of severity of ischemia on patients with coronary artery disease (CAD) by different therapy strategies. Background: Using myocardial ischemia severity determined by MPI guiding treatment strategies for CAD patients still lacks strong clinical evidences. Methods: Consecutive patients (N = 286) underwent clinical stress-rest SPECT MPI and were retrospectively followed-up. For assessment of outcome of treatment, all patients were classified into three groups (CCR, ICR, and NCR), and further divided into two subgroups as mild ischemia (< 10% ischemic myocardium) and moderate-severe ischemia (≥ 10% ischemic myocardium). All-cause death was defined as the primary endpoint, and the composite of deaths, nonfatal myocardial infarction, and repeat revascularization (MACE) as the secondary endpoint. Results: Two-hundred eighty-six patients were followed-up for 46 ± 21 months. Thirty deaths and 65 MACEs were recorded. Patients treated by revascularization had significantly lower MACE (P < .001) but not mortality (P = .158) than patients treated by NCR. Outcomes of CCR related to mortality rate were greater than ICR and NCR (death: P = .019, MACE: P < .001). In patients with moderate-severe ischemia, CCR showed improved outcomes than ICR and NCR (death: P = .034; and MACE: P < .001). In patients with mild ischemia, the outcomes of CCR, ICR, and NCR had no significant difference (P > .05). Multivariate regression Cox analysis revealed that summed difference score [death: HR 1.09 (1.03, 1.15), P = .004] was an independent risk factor and CCR was an independent negative predictor [death: HR 0.31 (0.12, 0.81), P = .017; MACE: HR 0.30 (0.16, 0.57), P < .001]. Conclusions: Outcomes of patients treated by CCR were most likely more promising in comparison with treatment of ICR and NCR, especially when patients had over 10% ischemic myocardium.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Implementation of Triply Periodic Minimal Surfaces (TPMS) as surface objects in OpenMC

Triply Periodic Minimal Surfaces (TPMS) represent a promising geometry for future fuel designs due to their significant surface-to-volume ratio, which facilitates efficient cooling of nuclear fuel, a crucial factor for safety and efficiency. Demonstrating the remarkable capabilities of TPMS fuel requires initial modeling and simulation. This paper presents an implementation of TPMS in the Monte Carlo code OpenMC, enabling reactor physics modeling of TPMS. Here, the primary advantages over traditional methods using CAD files include reduced memory requirements for computations and high-fidelity implementation. This implementation has been tested against CAD files loaded in Serpent2, yielding promising results with low biases in the $k_{\textrm{eff}}$, comparable to biases in the material balance sheet. The implementation presented in this work will be used in future reactor physics computations related to new reactor designs involving TPMS-based fuels.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Prostate Cancer Patients' Preferences for Intermittent vs. Continuous Androgen Deprivation—A Pilot Institutional Study

With locally advanced, recurrent, and metastatic prostate cancer patients, patient preference between intermittent (IAD) and continuous (CAD) androgen deprivation therapy has not been investigated. The goal of the study was to determine patients' preference for IAD vs. CAD therapy. The secondary aim was to elucidate demographic or treatment variables that may affect a patient's preference for one type of hormonal treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Microstructure and fracture properties of open-cell porous Ti-6Al-4V with high porosity fabricated by electron beam melting

Highlights: • The Ti-6Al-4V foams with 80% high porosity are prepared by electron beam melting. • The ligament width appears to play the major role for mechanical properties. • The work of fracture is a linear function of ligament width and roughness/width ratio. - Abstract: The open-cell porous Ti-6Al-4V structure with high porosity, intended to be applied as replacement for human cancellous bone, were fabricated by electron beam melting (EBM). Computer aided design (CAD) was applied to design porous structures using the same unit cell with different unit cell sizes from 2.5 to 4 mm, different ligament widths from 600 to 900 μm, and different pore sizes from 1200 to 1800 μm, in order to achieve high porosity of 80% in avoiding the stress shielding effect. In comparison with the CAD designs and the EBM samples, there were minor discrepancies in terms of pore size and ligament width, mainly a result of melting pool. The measured data on the Young's modulus and yield strength of the EBM porous samples can be predicted by the Gibson and Ashby model. All samples with high porosity were found to match well with cancellous bone, with Young's modulus of 2 GPa and yield stress of 31 MPa, effective to diminish the risk of stress shielding effect. For porous EBM sample with high 80% porosity, the work of fracture can increase from 15.9 to 47.6 kJ/m{sup 2} with increasing ligament width from 600 to 900 μm.

36 MATERIALS SCIENCE↗

An unstructured mesh based neutronics optimization workflow

We have developed a fully automated workflow to optimize the neutronics performance of the Second Target Station (STS) at the Oak Ridge National Laboratory’s Spallation Neutron Source. The optimization workflow starts with the parametrized solid CAD engineering models and converts them into the unstructured mesh (UM) models for the neutronics calculations with MCNP6.2. Calculations are executed and their results are loaded into the Dakota optimization toolkit. Dakota analyzes the results and proposes new geometry parameters for the next design iteration. The cycle repeats until the optimal parameters are found. The automated CAD to MCNP conversion, the use of high-fidelity UM models, and the use of modern optimizer are the key elements that advance the entire optimization workflow in comparison with the original workflow. The original workflow was based on a simplified constructive solid geometry (CSG) modeling with MCNPX, mcnp_pstudy tool, and an in-house optimizer. Herein to demonstrate the new workflow, we present a case of neutronics optimization of the moderator–reflector assembly (MRA). Apart from the MRA, the workflow can optimize other major STS components, such as the spallation target, neutron beamlines, radiation shielding, and various accelerator components. Importantly, the new workflow opens the door to the advanced multi-physics multi-parameter optimization and has the potential for use in other nuclear physics and accelerator applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗