Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Building Energy Efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

United States cool surfaces deployment plan

Solar-reflective building envelope surfaces, such as cool roofs and walls, can be especially helpful in disadvantaged communities that often have poorly insulated older homes, aging or absent air conditioning units, steep utility bills, polluted air, and high vulnerability and exposure to extreme heat. With support from the U.S. Department of Energy, our project seeks to dramatically increase the climate-appropriate deployment of cool surfaces across the United States with an emphasis on their application to disadvantaged communities. First, we sought to identify cool-surface deployment barriers, opportunities, and models by (a) reviewing the history of cool-surface deployment activities, (b) interviewing cool-surface stakeholders, (c) researching successful energy-efficiency/green building deployment models; and (d) interviewing the actors who have implemented these models. Second, we conducted a workshop to engage stakeholders in development of a deployment plan. Third, we asked several U.S. federal agencies (a) how cool surfaces and cool surface stakeholders could support their missions and (b) how agency activities could support cool-surface deployment. Fourth, we identified a set of transformative ideas that form the core of the deployment plan. Transformative ideas include but are not limited to initiatives to (a) launch an educational campaign to make the general public and building professionals aware of how cool roofs and walls exclude unwanted solar heat; (b) create a “Cool Roof Prize” stimulating the development of affordable, high-performance cool asphalt roofing shingles; (c) conduct high-profile, large-scale demonstration programs that bring cool surfaces to disadvantaged heat-vulnerable communities; and (d) support local, regional, and state climate action (heat mitigation) plans with cool surfaces.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Accelerating the Adoption of the Solid Panel Structural System

This report, "Accelerating the Adoption of the Solid Panel Structural System", explores the structural properties, capabilities, and applications for an innovative “studless” building system that uses a plate-like approach and “Perfect Wall” principles for an efficient, durable, and robust wall system. A comprehensive testing regime was completed to fully characterize the structural behavior of the Solid Panel Structural system. These results were used to develop an engineering guide that can be used by architects and engineers for design and code approval.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Highly Insulated Wall Systems with Exterior Insulation of Polyisocyanurate under Different Facer Materials: Material Characterization and Long-Term Hygrothermal Performance Assessment

The application of exterior insulation in both new construction and retrofits is a common practice to enhance the energy efficiency of buildings. In addition to increased thermal performance, the rigid insulation can serve to keep the sheathing board warm and serve as a water-resistive barrier to keep moisture-related problems due to condensation and wind-driven rain. Polyisocyanurate (PIR) rigid boards have a higher thermal resistance in comparison to other commonly used exterior insulation boards. However, because of its perceived lower permeance, its use as exterior insulation is not very common. In this study, the hygrothermal property of PIR boards with different facer types and thicknesses is characterized. The material data obtained through experimental test and extrapolation is used in a long term hygrothermal performance assessment of a wood frame wall with PIR boards as exterior insulation. Results show that PIR with no facer has the smallest accumulated moisture on the sheathing board in comparison to other insulation boards. Walls with a bigger thickness of exterior insulation perform better when no vapor barrier is used. The PIR exterior insulation supports the moisture control strategy well in colder climates in perfect wall scenarios, where there is no air leakage and moisture intrusion. In cases where there is trapped moisture, the sheathing board has a higher moisture content with PIR boards with both aluminum or fiberglass type facers. An innovative facer material development for PIR boards can help efforts targeting improved energy-efficient and durable wall systems.

36 MATERIALS SCIENCE↗

University of Hawai‘i, Shallow Geothermal Resources: Energy Technology Innovation Partnership Project (Final Report)

Scientists at Lawrence Berkeley National Laboratory (Berkeley Lab) have teamed up with the University of Hawai‘i at Manoa (UH Manoa) through the U.S. Department of Energy’s Energy Technology Innovation Partnership Project to evaluate the technological and market feasibility of shallow geothermal heat exchanger (GHE) technology. UH requested this analysis to evaluate opportunities in building cooling, energy efficiency, and emissions reduction applications in Hawai‘i. UH has an abundance of geologic and geothermal data and is looking to the national labs’ expertise to execute this analysis. UH is also interested in investigating policy, regulatory, and business conditions advantageous for implementation of a pilot project and more broad deployment of this technology in Hawai‘i. In many locations around the world, the demands for heating and cooling are roughly balanced over the course of the year, so GHEs do not cause significant long-term changes in subsurface temperature. This is not the case in Hawai’i, where the demand for heating is very small, meaning that, over time, GHEs will add heat to the subsurface. If temperatures increase significantly, GHE systems will not work as designed. Regional groundwater flow has the potential to sweep heated water away from boreholes, thereby maintaining the functionality of the GHE system. Significant regional groundwater flow requires two things: a sufficiently large driving hydraulic head gradient (usually closely related to surface topography), and sufficient porosity and permeability to enable groundwater to flow in large enough quantities to enable near-borehole temperatures to be maintained at ambient values. Hawai‘i’s volcanic terrain offers ample surface topographic variation. The lava itself shows an extremely large range of porosity and permeability, so sites with large enough values of these properties must be selected. Numerical modeling of coupled groundwater and heat flow can be used to determine how large is large enough. Primarily, closed-loop systems have been investigated. Other options considered are open-loop systems and using cool seawater as the chilling source. Project work investigated the feasibility of GHE technology at two scales. At the island scale, GIS layers of various attributes relevant for GHE were combined to develop an overall favorability map for employing GHE in Hawai‘i. At the local scale, a hydrogeologic model for the subsurface component of a closed-loop system was developed for the Stan Sheriff Center at the UH Manoa campus. This site is considered promising because the rock below and immediately downgradient of the borefield is highly permeable, consisting of a subsurface karst system (limestone containing high-permeability open channels), which is underlain by a thick, high-permeability fractured basalt. Moreover, the site is near the base of the Ko‘olau Range, providing a large hydraulic head gradient. Thus, groundwater flow through the site is expected to be large, enabling efficient removal of heated groundwater. A full-GHE-system model of the site was also developed, with a simplified representation of the subsurface, in which groundwater flow is not considered and heat transfer is purely by conduction. Using the building cooling load data provided by UH, simulation results show that with groundwater flow present, a GHE can operate successfully for at least 10 years, but with no groundwater flow, the subsurface begins to heat up after only one year of operation, making the GHE unviable within 2-6 years. The team also developed a techno-economic model for this site to compare the cost of cooling using a GHE system with the costs of operating the current air-conditioning system. The GHE system is advantageous economically if favorable tax incentives and interest rates can be obtained.

15 GEOTHERMAL ENERGY↗

pnnl/CPACE

C-PACE Market Assessment Tool This tool was developed for the U.S. Department of Energy’s Commercial Property Assessed Clean Energy (C-PACE) Working Group to support state and local governments creating, joining, and implementing C-PACE programs. This tool allows users to input a jurisdiction (city, county, or state) and automate a report with building characteristics, energy use, and energy efficiency savings opportunities for commercial buildings in that jurisdiction. The report generated by the tool identifies jurisdiction-specific energy end uses, building use types, and building technologies that a local C-PACE program should consider focusing on to more effectively allocate limited resources and maximize energy savings and investment.

Keene, Kevin↗

Radiative cooling and thermoregulation in the earth’s glow

Efficient passive radiative cooling of buildings requires an unimpeded view of the sky. However, vertical facades of buildings mostly see terrestrial features that become broadband-radiative heat sources in the summer and heat sinks in the winter. The resulting summertime terrestrial heat gain by buildings negates or overwhelms their narrowband longwave infrared (LWIR) radiative cooling to space, while the wintertime terrestrial heat loss causes overcooling. We show that selective LWIR emitters on vertical building facades can exploit the differential transmittance of the atmosphere toward the sky and between terrestrial objects to achieve higher summertime cooling and wintertime heating than conventionally used broadband emitters. The impact of this novel and passive thermoregulation is comparable to that of painting dark roofs white and is achievable with both novel and commonplace materials. Our findings represent new and remarkable opportunities for materials design and untapped thermoregulation of entities ranging from buildings to human bodies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Origin of high optical contrast in zinc-zinc oxide electrodeposits for dynamic windows

The control of solar light and heat emission through windows is an important strategy for increasing the energy efficiency of buildings. Reversible Zn electrodeposition has recently emerged as a promising method for constructing electronically tintable robust dynamic windows. In Zn electrodeposits formed from dimethyl sulfoxide (DMSO) electrolytes during device tinting, we observe extraordinary absorption that is in excess of what is predicted by the Beer-Lambert law for a uniform Zn thin film. Here, the charge required to electroplate these films is abnormally low, significantly less than previously reported dynamic windows based on reversible metal electrodeposition, which facilitates the construction of large-area devices that switch uniformly. Finite-difference time-domain (FDTD) simulations are used to investigate the origin of this enhanced absorption, which arises from plasmonic effects among the Zn nanoparticles and ZnO dendrites in the film. The dielectric ZnO dendrites promote absorption via slit-like Zn-dielectric-Zn structures that from hybrid surface plasmon resonance at metal walls. Through these investigations, we provide design principles to construct low-charge and high-contrast metal and metal oxide-based dynamic windows.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Dual-Band Electrochromism in Hydrous Tungsten Oxide

The independent modulation of visible and near-infrared light by a single material, termed dualband electrochromism, is highly desirable for smart windows to enhance the energy efficiency of buildings. Tungsten oxides are commercially important electrochromic materials, exhibiting reversible visible and near-infrared absorption when electrochemically reduced in an electrolyte containing small cations or protons. The presence of structural water in tungsten oxides has been associated with faster electrochromic switching speeds. Here, we find that WO 3 ·H 2 O, a crystalline hydrate, exhibits dual-band electrochromism unlike the anhydrous WO 3 providing a heretofore unexplored route to tune the electrochromic response of tungsten oxides. Absorption of near-infrared light is achieved at low Li + /e - injection, followed by the absorption of visible light at higher Li + /e - injection as a result of an electrochemically-induced phase transition. We propose that this dual-band modulation is possible due to the more open structure of WO 3 ·H 2 O as compared to WO 3 . This facilitates a more extended solid solution Li + insertion regime that benefits the modulation of near-infrared radiation via plasmon absorption. Higher degrees of Li + /e - insertion lead to polaronic absorption associated with localized charge storage. Furthermore, these results inform how structural factors influence the electrochemically induced spectral response of transition metal oxides and the important role of structural water beyond optical switching speed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building a Diverse and Inclusive STEM Workforce: The JUMP into STEM Program: Preprint

The JUMP into STEM program is a DOE-funded initiative jointly run by the National Renewable Energy Laboratory and Oak Ridge National La-boratory. Through this program, students from historically underrepresented backgrounds are engaged in the science of building energy-efficient infrastruc-ture. Through program stages, students have opportunity to compete in chal-lenges, competitions, and internship opportunities. We have conducted a study of past participants in the program. We find that 1) the program has been effec-tive at engaging a diverse array of participants from a variety of backgrounds, including historically underrepresented backgrounds, and 2) the program has been effective at promoting career paths in STEM, and more specifically, in en-ergy efficiency.

DEI↗

Natural fibers as promising core materials of vacuum insulation panels

To reduce energy consumption in buildings, this paper investigates the feasibility of using natural fibers as cost-effective, environmentally sustainable core materials for vacuum insulation panels (VIPs). First, a comprehensive experimental study was conducted for 10 potential natural fiber candidates. The thermal conductivities of the 10 natural fiber mats at various vacuum pressures were measured; their compression and morphology properties were quantified. In addition, an analytical model was used to explore the major factors that influence the thermal conductivity of natural fibers as a function of internal air pressure. Results show that recycled cotton, kapok, and bamboo fibers are ideal candidates for VIP core materials; at <0.05 Pa, their thermal conductivities varied between 2 and 4 mW/(m∙K). Furthermore, for some fibers, thermal conductivity was inversely proportional to fiber density. For the selection of fiber materials for VIP cores, the ideal fiber candidate has a small fiber diameter and a low fiber mat density. Based on thermal measurements, even though the internal air pressure of 5 Pa was enough to attain the minimum thermal conductivity, obtaining internal air pressure below 5 Pa is recommended for prolonged service life, considering small leaks of VIP package barrier films and potential off-gassing from fibers. The simulation results predicting the effective thermal conductivities matched the experimental results well. These findings indicate that natural fiber–based VIPs have the potential to be a sustainable, inexpensive alternative to the current technologies in building insulation materials.

36 MATERIALS SCIENCE↗

Field validation of data-driven BSDF and peak extraction models for light-scattering fabric shades

Shading and daylighting systems affect cooling, heating, and lighting energy use by modulating solar radiation through the building façade. Characterizing shading systems holistically and accurately helps designers and engineers evaluate shading systems to achieve energy and non-energy performance goals. These complex fenestration systems can be modeled using Bidirectional Scattering Distribution Functions (BSDF), which map incident radiation to hemispherical distributions of outgoing radiation. Data-driven, tabulated BSDFs are derived from interpolated goniophotometer measured data, then sampled during the raytracing calculation. A peak extraction (PE) algorithm was developed to circumvent limits in BSDF angular resolution, where the specular peak is extracted during simulation by evaluating the BSDF in the through direction and surrounding region. The objective of this study was to validate this measurement and modeling workflow using field monitored data from a full scale testbed with eleven installed fabrics of different weaves, openness factors, and colors and assess the accuracy of the workflow under different adaptation and contrast conditions. Test conditions were limited to clear sky conditions with the sun in the field of view. Results showed that, for tensor tree datasets, vertical illuminance, solar luminance (2.5° apex), and daylight glare probability (DGP) were predicted to within a mean bias error (MBE) error of -456 lx (-12.3%), -3.46e5 (-38.4%), and -0.042 (-7.8%) when full PE occurred. With a binary classification of glare/ no glare, DGP was predicted accurately with a true positive rate of 0.98 and true negative rate of 1.0 using tensor tree data and less accurately with Klems BSDF data, particularly for cases of no glare. The workflow may be of insufficient accuracy to distinguish borderline performance between fabrics using the four-point glare scale, particularly under low adaptation, high contrast daylit conditions. Errors were due to reductions in peak shape and intensity across the BSDF interpolation and data reduction workflow. Future work is needed to better preserve measurement fidelity during interpolation and sampling, which in turn will improve PE performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

What, why and when to go virtual: An international analysis of early adopters of virtual building energy codes inspections

To meet greenhouse gas reduction targets, several countries are pursuing more ambitious policies in their buildings and construction sectors, such as introducing zero net energy/carbon building codes. Countries often report not having enough qualified staff for performing building energy code inspections and many are exploring faster, easier, and more reliable methods to check the compliance of buildings with their codes. Building inspections are a critical element for ensuring code compliance and they have traditionally been performed in person. However, in-person inspections can be labor and travel intensive, costly, and prone to human error. In this paper, the authors explore how virtual inspections, particularly in light of the recent COVID-19 pandemic, have impacted processes for building code compliance checks in jurisdictions and communities around the world. Here, the authors collected data on four key parameters (time and financial savings, scope of inspections, changing practices and technological innovation, and benefits to consumers) from six jurisdictions and communities in five countries (Australia, Canada, Singapore, United Arab Emirates, and the United States) to analyze the impacts of virtual inspections on code compliance checks. The analysis found the greatest value from virtual inspections in geographically dispersed regions and for cities experiencing rapid building construction. The study also explored emerging technologies that are being piloted for virtual inspections. Although many of these technologies hold promise, more resources and capacity are needed to make them viable for use in building energy code inspections.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The electric vehicles-solar photovoltaics Nexus: Driving cross-sectoral adoption of sustainable technologies

Residential and transportation energy consumption account for more than one-half of the overall energy consumption in the United States. Adoption of electric vehicles (EVs) can play a key role in decarbonizing the transportation sector, while the adoption of renewable energy sources (e.g., solar photovoltaics [PVs]) could bring similar benefits to the residential energy sector and in turn support transport electrification. Although the market shares for both EVs and PVs continue to grow, both of these emerging technologies are deployed rather disjointly, without considering the existence of potential similarities among users who own (or aspire to own) these technologies. This might be due to lack of understanding of the behavioral interdependence in consumer preferences toward these technologies. To fill this gap in knowledge, this study utilizes data from the 2018 WholeTraveler Transportation Behavior Study to develop an integrated model system that explores interactive EV and PV adoption behaviors. A structural equation model is employed that incorporates direct effects as well as error correlations among the adoption behaviors for EVs and PVs. Model results indicate that the adoption behavior for both these technologies is indeed interconnected and significantly influenced by attitudes, values, and personality traits. Findings from this research suggest that incentives (e.g., subsidies) that drive bundled adoption of EV-PV systems could accelerate the adoption of both of these sustainable technologies. In conclusion, this study highlights the need to consider transport and building energy-efficient technology adoption behavior in a single integrated structure.

14 SOLAR ENERGY↗

A labeled dataset for building HVAC systems operating in faulted and fault-free states

Abstract Open data is fueling innovation across many fields. In the domain of building science, datasets that can be used to inform the development of operational applications - for example new control algorithms and performance analysis methods - are extremely difficult to come by. This article summarizes the development and content of the largest known public dataset of building system operations in faulted and fault free states. It covers the most common HVAC systems and configurations in commercial buildings, across a range of climates, fault types, and fault severities. The time series points that are contained in the dataset include measurements that are commonly encountered in existing buildings as well as some that are less typical. Simulation tools, experimental test facilities, and in-situ field operation were used to generate the data. To inform more data-hungry algorithms, most of the simulated data cover a year of operation for each fault-severity combination. The data set is a significant expansion of that first published by the lead authors in 2020.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of the Passive Cooling Potential of Thermal Mass Inherent in Medium to Large Commercial Buildings

Typical commercial construction inherently contains large surface areas of relatively thin mass located in the floor slabs. This research asks how effective this mass could be for passive cooling, relative to other mass depths, if it were to be exposed and used as thermal mass. Although much of the rich literature on thermal mass has been conducted with far greater mass depths, a more limited amount of research suggests that because the surface heat transfer rate is limited, the focus should be on the surface area of exposed mass, not its depth. This presents an opportunity for more buildings to behave more thermally massively, if the mass inherent in typical floor slabs contains utility, particularly over diurnal cycles. In all climates analyzed, it was found that there is a pronounced shoulder where energy savings from passive cooling of increasing mass depths was steep until roughly 7.5–10 cm, and beyond this point the achieved energy savings diminished rapidly. When considering the embodied energy of concrete, the incremental benefit of added mass beyond a typical topping slab of 10 cm does not justify the incremental embodied energy cost from a total energy standpoint alone.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pre-Commercial Scale-Up of a Gas-Fired Absorption Heat Pump

The project sought to advance the maturity of SMTI’s 80 kBTU/hr residential space and water heating GAHP from the engineering prototype stage (TRL-7) to pre-production readiness by addressing manufacturing, balance of system design and installation, cost, reliability, and field application questions. As part of this project, the project team has: (1) Matured the design package for a commercially ready product (2) Demonstrated compliance with relevant ANSI standards (3) Completed manufacturing and assembly process specifications (4) Completed total production cost estimates and capital equipment requirements (5) Initiated component and system level reliability assessments (6) Completed a small field demonstration including measured performance, installation requirements and expected costs, and customer/key stakeholder feedback. (7) Completed a Techno-economic analysis for representative applications and climate zones, including justification for utility incentive programs. (8) Completed a market intelligence report. Scope of Work: A multi-faceted project was completed that included: (a) design for manufacturing tasks for both the sealed system and balance of system, (b) development and trial of key manufacturing processes and techniques, (c) evaluation of component and system level reliability, (d) exploration of make/buy decisions including impact on cost and required capital. Additionally, (e) installation and monitoring of a small number of field test units was completed to demonstrate energy savings and collect customer/installer feedback, and (f) a focused market research task was completed to explore potential barriers and improve market introduction plans. These tasks addressed many of the remaining technical risks regarding long-term reliability, verification of manufacturing cost estimates and identification of cost concerns, identify installation and balance of system design criteria necessary to achieve energy savings and installed cost goals, and identify market barriers and strategies prior to product market introduction.

03 NATURAL GAS↗