Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Braggs scattering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

266 records · Page 15

Optical Design of $\mathrm{DEI/ABI}$ System at the $\mathrm{HEX}$ Beamline at the $\mathrm{NSLS-II}$

Diffraction Enhanced Imaging (DEI) or Analyzer Based Imaging (ABI) uses a perfect crystal monochromator and matching analyzer to achieve sensitivity to x-ray refraction and ultra small-angle scattering on the order of 0.01 micro-radians. As such, a thermal bump caused by heat-load in the order of 1 W is detrimental. The heat load at the HEX (High Energy Engineering X-ray) super-conducting wiggler (SCW) beamline, under construction at the NSLS-II, is on the order of 1 kW. How to reconcile the three orders of magnitude difference between the HEX source power and the DEI/ABI requirements? The solution involves using a double-crystal bent-Laue monochromator as pre-monochromator to prepare a beam with a large divergence and bandwidth that is matched to a flat crystal post-monochromator. We show through phase-space (x-ray energy vs. angle as viewed by a flat crystal) analysis and Dumond diagrams that there is indeed a unique bending radius that matches the double-crystal bent-Laue monochromator in phase space to the flat Bragg crystal. The matched system has a desirable feature that the phase space of the bent crystal’s output beam is much larger than that of the flat crystal, making the combined system stable. Based on these considerations, here we present our optical design for performing DEI/ABI at the HEX beamline

36 MATERIALS SCIENCE↗

Anisotropy of antiferromagnetic domains in a spin-orbit Mott insulator

The temperature-dependent behavior of magnetic domains plays an essential role in the magnetic properties of materials, leading to widespread applications. However, experimental methods to access the three-dimensional (3D) magnetic domain structures are very limited, especially for antiferromagnets. Over the past decades, the spin-orbit Mott insulator iridate Sr 2 IrO 4 has attracted particular attention because of its interesting magnetic structure and analogy to superconducting cuprates. Here, in this work, we apply resonant x-ray magnetic Bragg coherent diffraction imaging to track the real-space 3D evolution of antiferromagnetic ordering inside a Sr 2 IrO 4 single crystal as a function of temperature, finding that the antiferromagnetic domain shows anisotropic changes. The anisotropy of the domain shape reveals the underlying anisotropy of the antiferromagnetic coupling strength within Sr 2 IrO 4 . These results demonstrate the high potential significance of 3D domain imaging in magnetism research.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Scaling behavior of low-temperature orthorhombic domains in the prototypical high-temperature superconductor La 1.875 Ba 0.125 CuO 4

Structural symmetry breaking and recovery in condensed-matter systems are closely related to exotic physical properties such as superconductivity (SC), magnetism, spin density waves, and charge density waves (CDWs). The interplay between different order parameters is intricate and often subject to intense debate, as in the case of CDW order and superconductivity. In La 1.875 Ba 0.125 CuO 4 (LBCO), the low-temperature structural domain walls are hypothesized as nanometer-scale pinning sites for the CDWs. Coherent x-ray diffraction techniques have been employed here to visualize the domain structures associated with these symmetry changes directly during phase transition. We have pushed Bragg coherent diffractive imaging (BCDI) into the cryogenic regime where most phase transitions in quantum materials reside. Utilizing BCDI, we image the structural evolution of LBCO microcrystal samples during the high-temperature tetragonal to low-temperature orthorhombic (LTO) phase transition. Our results show the formation of LTO domains close to the transition temperature and how the domain size decreases with temperature. In conclusion, the number of domains follows the secondary order parameter (or orthorhombic strain) measurement with a critical exponent that is consistent with the three-dimensional universality class.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Imaging surface topography with coherent x-ray reflectivity: Theory, kinematics, and simulations

A theoretical formalism is described for understanding coherent x-ray reflectivity (CXR) from the surface of a semi-infinite crystal having a variable surface topography, described by the height profile ℎ(𝑥,𝑦). The surface topography is imaged as a complex “effective density,” obtained from the phasing and inversion of the coherent x-ray reflectivity data, measured through a rocking scan centered at a vertical momentum transfer 𝑄$^{0}_{𝑧}$ and a vertical range Δ⁢𝑄 𝑧 . The formalism predicts that the effective density has an amplitude with a maximum located at the surface height for each position within the surface plane. The phase of the effective density has a lateral variation that is controlled by the surface height and a vertical variation that reflects a combination of the interfacial structure and specific choice of measurement conditions. This understanding enables direct observation of nanometer-scale interfacial topography, i.e., ℎ⁡(𝑥,𝑦)⁢𝑐 𝑠 (where 𝑐 𝑠 is the vertical substrate lattice parameter) with Å-scale sensitivity to surface height. Numerical simulations illustrate and confirm the theoretical results. These results show how the interpretation of the interfacial density phase obtained by CXR data inversion (i.e., surface topography with respect to a flat surface) is conceptually similar to that previously known for Bragg coherent diffraction imaging (BCDI) measurements of isolated nanoparticles (i.e., lattice displacements with respect to an ideal crystal lattice). This suggests that CXR can be thought of as a form of dark field imaging with respect to the bright field BCDI approach. An implication of these results is that interfacial imaging may bypass some of the significant challenges associated with BCDI imaging of multiple particles having different orientations.

X-ray imaging↗

Gas Transfer Across Air‐Water Interfaces in Inland Waters: From Micro‐Eddies to Super‐Statistics

In inland water covering lakes, reservoirs, and ponds, the gas exchange of slightly soluble gases such as carbon dioxide, dimethyl sulfide, methane, or oxygen across a clean and nearly flat air‐water interface is routinely described using a water‐side mean gas transfer velocity $\overline{k_{L}}$, where overline indicates time or ensemble averaging. The micro‐eddy surface renewal model predicts $\overline{k_{L}}$ = α o Sc -1/2 ($v\bar{ϵ}$) 1/4 , where Sc is the molecular Schmidt number, $v$ is the water kinematic viscosity, and $\bar{ϵ}$ is the waterside mean turbulent kinetic energy dissipation rate at or near the interface. While α o = 0.39 - 0.46 has been reported across a number of data sets, others report large scatter or variability around this value range. It is shown here that this scatter can be partly explained by high temporal variability in instantaneous ϵ around $\bar{ϵ}$, a mechanism that was not previously considered. As the coefficient of variation (CV e ) in ϵ increases, α o must be adjusted by a multiplier (1 = CV e 2 ) -3/32 that was derived from a log‐normal model for the probability density function of ϵ. Reported variations in α o with a macro‐scale Reynolds number can also be partly attributed to intermittency effects in ϵ. Such intermittency is characterized by the long‐range (i.e., power‐law decay) spatial auto‐correlation function of ϵ. That α o varies with a macro‐scale Reynolds number does not necessarily violate the micro‐eddy model. Instead, it points to a coordination between the macro‐ and micro‐scales arising from the transfer of energy across scales in the energy cascade.

Batchelor scale↗

Multiplexing Focusing Analyzer for Efficient Stress-Strain Measurements

Statement of the problem or situation that is being addressed. Although thermal and cold neutron scattering is widely used and is critical for success in many areas of materials science and engineering, relatively low neutron fluxes severely limit applications of not only laboratory neutrons generators, but also large national neutron facilities. State-of-the-art thermal and cold neutron sources are large expensive national facilities, which serve diverse community of scientific and industrial users. The constant need to improve the instruments performance, stems from the fact that neutron methods are gaining in popularity, and becoming more and more powerful, while new neutron sources are not being constructed to keep pace with the developments and needs of the scientific community. Small research reactors at universities and National Labs, and laboratory-based neutron generators, are necessary not only for education and training, but also when samples cannot be transported to other facilities. However, the standard neutron techniques, which were developed for high-flux facilities, require much higher efficiencies to be used effectively with the low fluxes of small sources. Thus, the efficient use of neutron sources, such as with our proposed analyzer, is important for the progress and broader use of these neutron techniques. General statement of how this problem is being addressed. We propose to design and demonstrate novel diffractive optical device, which will enable very efficient residual stress neutron diffractometers. The proposed device will be a multi-foil analyzer, where each foil is constructed of focusing bent single crystals of Si. Such device will enable polychromatic residual stress neutron diffraction. At large national facilities, such as at Oak Ridge National Laboratory, these analyzers would enable very fast measurements for determining residual stress tensors, raster large samples or screen multiple samples. Commercial Applications and Other Benefits The outcome of this project would be the demonstration of commercial devices, novel neutron optical components, which could be utilized to improve the performance of existing instruments or build novel neutron scattering instruments at DOE neutron facilities and commercial laboratory neutron sources. These new devices will widen the scope of research conducted using neutrons and enable measurements not feasible at present. Summary for Members of Congress Thermal and cold neutron beams are a powerful materials science probe, which provide unique information about the structure of matter. The proposed innovations expand the reach of neutron-based investigations to new materials and industries by enabling new instrumentation capabilities, thereby greatly enhancing and expanding the role of small, laboratory-based neutron instrumentation, and improving education and training of neutron users.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Exploring Cosmic X-ray Source Polarization

Cosmic X-ray sources are expected to be polarized, either because of their asymmetry and the role of scattering in their emission or the role of magnetic fields. Polarization at other wavelengths has been useful. X-ray polarization will provide a new handle on black hole parameters, in particular the spin, on accretion flows and outflows, on neutron star spin orientations and emission mechanisms, on the quantum mechanical effects of super-strong magnetic fields of magnetars, and on the structure of supernovae shocks. The proposed Gravity and Extreme Magnetism SMEX (GEMS) will use high efficiency polarimeters behind thin foil mirrors. The statistical sensitivity and control of systematics will allow measurement of polarization fractions as small as 1% from many galactic and extragalactic sources. Targets which should be polarized at the level that GEMS can easily measure include stellar black holes, Seyfert galaxies and quasars, blazars, rotation-powered and accretion-powered pulsars, magnetars, shell supernova remnants and pulsar wind nebulae. The polarimeters are Time Projection Chambers that allow reconstruction of images of photoelectron tracks for 2-10 keV Xrays. They can be deep without sacrificing modulation. These polarimeters do not image the sky, but the telescope point spread function and detector collimation allow structure to be resolved at the 10 arcmin level. Rotation of the spacecraft is not needed for the signal measurement in the Time Projection Chambers, but provides for measurement and correction of systematic errors. It also allows a small Bragg reflection soft X-ray experiment to be included that can be used for isolated neutron stars and blazars.

Swank, Jean Hebb↗

Nucleation and Crystallization of Globular Proteins: What we Know and What is Missing

Recently. much progress has been made in understanding the nucleation and crystallization of globular proteins, including the formation of compositional and structural crystal defects, Insight into the interactions of (screened) protein macro-ions in solution, obtained from light scattering, small angle X-ray scattering and osmotic pressure studies. can guide the search for crystallization conditions. These studies show that the nucleation of globular proteins is governed by the same principles as that of small molecules. However, failure to account for direct and indirect (hydrodynamic) protein interactions in the solutions results in unrealistic aggregation scenarios. Microscopic studies of numerous proteins reveal that crystals grow by the attachment of growth units through the same layer-spreading mechanisms as inorganic crystals. Investigations of the growth kinetics of hen-egg-white lysozyme (HEWL) reveal non-steady behavior under steady external conditions. Long-term variations in growth rates are due to changes in step-originating dislocation groups. Fluctuations on a shorter timescale reflect the non-linear dynamics of layer growth that results from the interplay between interfacial kinetics and bulk transport. Systematic gel electrophoretic analyses suggest that most HEWL crystallization studies have been performed with material containing other proteins at percent levels. Yet, sub-percent levels of protein impurities impede growth step propagation and play a role in the formation of structural/compositional inhomogeneities. In crystal growth from highly purified HEWL solutions, however, such inhomogeneities are much weaker and form only in response to unusually large changes in growth conditions. Equally important for connecting growth conditions to crystal perfection and diffraction resolution are recent advances in structural characterization through high-resolution Bragg reflection profiling and X-ray topography.

Rosenberger, F.↗

Crystallography of low Z material at ultrahigh pressure: Case study on solid hydrogen

Diamond anvil cell techniques have been improved to allow access to the multimegabar ultrahigh-pressure region for exploring novel phenomena in condensed matter. However, the only way to determine crystal structures of materials above 100 GPa, namely, X-ray diffraction (XRD), especially for low Z materials, remains nontrivial in the ultrahigh-pressure region, even with the availability of brilliant synchrotron X-ray sources. In this work,we perform a systematic study, choosing hydrogen (the lowest X-ray scatterer) as the subject, to understand how to better perform XRD measurements of low Z materials at multimegabar pressures. The techniques that we have developed have been proved to be effective in measuring the crystal structure of solid hydrogen up to 254 GPa at room temperature [C. Ji et al.,Nature 573, 558–562 (2019)]. We present our discoveries and experiences with regard to several aspects of this work, namely, diamond anvil selection, sample configuration for ultrahigh-pressure XRD studies,XRD diagnostics for low Z materials, and related issues in data interpretation and pressure calibration.We believe that these methods can be readily extended to other low Z materials and can pave the way for studying the crystal structure of hydrogen at higher pressures, eventually testing structural models of metallic hydrogen.

36 MATERIALS SCIENCE↗

Symmetry breaking during low-temperature domain formation in micron-sized magnetite crystals

We report the results of synchrotron Bragg Coherent x-ray Diffraction Imaging (BCDI) experiments to investigate domain formation in a micron-sized magnetite crystal undergoing the Verwey transition at low temperature. A strong splitting of the measured 311 Bragg reflection was observed in the low-temperature phase, indicating the formation of domains. BCDI revealed pronounced strain distributions, characterized by a clear layered stripe domain structure in real-space. Stripes were seen only along the [001] crystallographic direction, normal to the substrate surface direction, breaking the symmetry of the cubic high-temperature phase. It is argued that other domain directions were suppressed by the sample mounting orientation. More surprisingly, only a single domain orientation was observed, suggesting an additional symmetry-breaking influence originating from the shape of the crystal. Gaining insight into how thermal effects induce the formation of layered or striped phases offers a valuable framework for understanding the development of mesoscopic domains and strain patterns in functional materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

NASA Tech Briefs, January 2012

Contents of this issue are: (1) Energy-Based Tetrahedron Sensor for High-Temperature, High-Pressure Environments (2) Handheld Universal Diagnostic Sensor (3) Large-Area Vacuum Ultraviolet Sensors (4) Fiber Bragg Grating Sensor System for Monitoring Smart Composite Aerospace Structures (5) Health-Enabled Smart Sensor Fusion Technology (6) Extended-Range Passive RFID and Sensor Tags (7) Hybrid Collaborative Learning for Classification and Clustering in Sensor Networks (8) Self-Healing, Inflatable, Rigidizable Shelter (9) Improvements in Cold-Plate Fabrication (10) Technique for Radiometer and Antenna Array Calibration - TRAAC (11) Real-Time Cognitive Computing Architecture for Data Fusion in a Dynamic Environment (12) Programmable Digital Controller (13) Use of CCSDS Packets Over SpaceWire to Control Hardware (14) Key Decision Record Creation and Approval Module (15) Enhanced Graphics for Extended Scale Range (16) Debris Examination Using Ballistic and Radar Integrated Software (17) Data Distribution System (DDS) and Solar Dynamic Observatory Ground Station (SDOGS) (18) Integration Manager (19) Eclipse-Free-Time Assessment Tool for IRIS (20) Automated and Manual Rocket Crater Measurement Software (21) MATLAB Stability and Control Toolbox Trim and Static Stability Module (22) Patched Conic Trajectory Code (23) Ring Image Analyzer (24) SureTrak Probability of Impact Display (25) Implementation of a Non-Metallic Barrier in an Electric Motor (26) Multi-Mission Radioisotope Thermoelectric Generator Heat Exchangers for the Mars Science Laboratory Rover (27) Uniform Dust Distributor for Testing Radiative Emittance of Dust-Coated Surfaces (28) MicroProbe Small Unmanned Aerial System (29) Highly Stable and Active Catalyst for Sabatier Reactions (30) Better Proton-Conducting Polymers for Fuel-Cell Membranes (31) CCD Camera Lens Interface for Real-Time Theodolite Alignment (32) Peregrine 100-km Sounding Rocket Project (33) SOFIA Closed- and Open-Door Aerodynamic Analyses (34) Sonic Thermometer for High-Altitude Balloons (35) Near-Infrared Photon-Counting Camera for High-Sensitivity Observations (36) Integrated Optics Achromatic Nuller for Stellar Interferometry (37) High-Speed Digital Interferometry (38) Ultra-Miniature Lidar Scanner for Launch Range Data Collection (39) Shape and Color Features for Object Recognition Search (40) Explanation Capabilities for Behavior-Based Robot Control (41) A DNA-Inspired Encryption Methodology for Secure, Mobile Ad Hoc Networks (42) Quality Control Method for a Micro-Nano-Channel Microfabricated Device (43) Corner-Cube Retroreflector Instrument for Advanced Lunar Laser Ranging (44) Electrospray Collection of Lunar Dust (45) Fabrication of a Kilopixel Array of Superconducting Microcalorimeters with Microstripline Wiring Spacecraft Attitude Tracking and Maneuver Using Combined Magnetic Actuators (46) Coherent Detector for Near-Angle Scattering and Polarization Characterization of Telescope Mirror Coatings

Source record↗

Low-temperature state in strontium titanate microcrystals using in situ multireflection Bragg coherent x-ray diffraction imaging

Strontium titanate is a classic quantum paraelectric oxide material that has been widely studied in bulk and thin films. It exhibits a well-known cubic-to-tetragonal antiferrodistortive phase transition at 105 K, characterized by the rotation of oxygen octahedra. A possible second phase transition at lower temperature is suppressed by quantum fluctuations, preventing the onset of ferroelectric order. However, recent studies have shown that ferroelectric order can be established at low temperatures by inducing strain and other means. Here, we used in situ multireflection Bragg coherent x-ray diffraction imaging to measure the strain and rotation tensors for two strontium titanate microcrystals at low temperature. We observe strains induced by dislocations and inclusion-like impurities in the microcrystals. Based on radial magnitude plots, these strains increase in magnitude and spread as the temperature decreases. Pearson's correlation heat maps show a structural transition at 50 K, which could possibly be the formation of a low-temperature ferroelectric phase in the presence of strain. We do not observe any change in local strains associated with the tetragonal phase transition at 105 K.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

X-ray atomic mapping of quantum dots

We report a model-independent atomic-mapping technique for quantum dots (QDs) by combining Bragg reflection x-ray standing wave (XSW) and grazing incidence diffraction (GID) measurements. In this study, we choose GaAs capped InGaAs QDs/GaAs(001) as a model system to show the locations and arrangements of indium atoms within the QDs along various [hkl] directions. This technique directly reveals the actual amount of positional anisotropy and ordering fraction of indium atoms within the QDs by probing the (1¯11), (111), (311), (1¯31), (113), and (1¯13) crystallographic planes. We find that indium atoms are outwardly shifted along the [001] direction by small fractions of the lattice constant, 0.04a GaAs and 0.06a GaAs from Ga sites for 50- and 150-Å GaAs capped InGaAs QDs, respectively. We observe that an improved coherency factor of the indium atoms within the QDs by 45–60% along the [001] and [011] directions reduces the photoluminescence linewidth by 22%, thus making the QDs efficient for QD-laser and optoelectronic device applications. Here, we also find that the position and ordering of In atoms along the (113) and (1¯13) planes are most sensitive to the thickness of the GaAs cap layer. Our XSW-based results are supported by numerical calculations using a QD-macroscopic structural model based on our GID study. We thus show that this atomic-mapping technique will be useful for studying various quantum structures and tuning their properties.

36 MATERIALS SCIENCE↗

Mechanistic Insights into Defect-Mediated Crystallization Revealed by Lattice Strain Evolution

Structural defects and lattice strain are intrinsic to many crystalline materials, yet their roles in controlling chemical reaction mechanisms and directing crystallization pathways remain poorly understood. Here, in this study, we revealed the three-dimensional evolution of strain and dislocation defects at the nanoscale during the growth of heterogeneously nucleated barite (BaSO 4 ) and calcite (CaCO 3 ) crystals by using coherent X-ray scattering, electron microscopy, and molecular simulations. Unlike barite, which formed with minimal internal strain, calcite developed dislocation defects and exhibited spatially varying strain that increased during growth. During growth in Sr-rich solutions, calcite likely incorporates Sr 2+ into the defects, which further modulates the local lattice structure and increases both the compressive and tensile strain. These findings suggest that calcite crystallization was likely dominated by attachment of precursor phases, which gave rise to defect-enriched domain structures not predicted by classical growth models. By linking defect formation to ion incorporation and growth dynamics, this work provides fundamental insight into how lattice-level strain heterogeneity governs the chemical reactivity of ionic crystals.

Bragg coherent diffractive imaging↗