Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BERT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Observation-Based Evaluation of Flood Estimation Techniques for a Small Snow-Dominated Basin in the Washington Cascade Mountains

Here, this study examines the application of the recently developed next-generation intensity-duration-frequency (NG-IDF) curves in hydrological design, focusing on a small snow-dominated basin in Washington state. Four methods are used to assess the NG-IDF performance: (1) basin outlet flood frequency analysis, (2) use of standard precipitation-based intensity-duration-frequency (PREC-IDF) curves following surface water design manuals typically used in the basin, (3) utilization of locally constructed PREC-IDF curves, and (4) use of locally constructed NG-IDF curves. The standard PREC-IDF design method assumes precipitation as rainfall and neglecting snowmelt or rain-on-snow (ROS) events that can lead to significant flood underestimations in the test basin. In contrast, the NG-IDF method incorporates snow processes and shows promising improvements in accurately estimating design floods. The validation analysis demonstrates the superiority of NG-IDF over standard and local PREC-IDF in this test basin. The study highlights the necessity for adjustments in current design manuals to ensure sufficient flood protection, particularly in light of the planned substantial investments in US infrastructure.

13 HYDRO ENERGY↗

Steady-state and transient photoconductivity in c-axis GaN nanowires grown by nitrogen-plasma-assisted molecular beam epitaxy

Analysis of steady-state and transient photoconductivity measurements at room temperature performed on c-axis oriented GaN nanowires yielded estimates of free carrier concentration, drift mobility, surface band bending, and surface capture coefficient for electrons. Samples grown (unintentionally n-type) by nitrogen-plasma-assisted molecular beam epitaxy primarily from two separate growth runs were examined. The results revealed carrier concentration in the range of (3-6)x10{sup 16} cm{sup -3} for one growth run, roughly 5x10{sup 14}-1x10{sup 15} cm{sup -3} for the second, and drift mobility in the range of 500-700 cm{sup 2}/(V s) for both. Nanowires were dispersed onto insulating substrates and contacted forming single-wire, two-terminal structures with typical electrode gaps of {approx_equal}3-5 {mu}m. When biased at 1 V bias and illuminated at 360 nm (3.6 mW/cm{sup 2}) the thinner ({approx_equal}100 nm diameter) nanowires with the higher background doping showed an abrupt increase in photocurrent from 5 pA (noise level) to 0.1-1 {mu}A. Under the same conditions, thicker (151-320 nm) nanowires showed roughly ten times more photocurrent, with dark currents ranging from 2 nA to 1 {mu}A. With the light blocked, the dark current was restored in a few minutes for the thinner samples and an hour or more for the thicker ones. The samples with lower carrier concentration showed similar trends. Excitation in the 360-550 nm range produced substantially weaker photocurrent with comparable decay rates. Nanowire photoconductivity arises from a reduction in the depletion layer via photogenerated holes drifting to the surface and compensating ionized surface acceptors. Simulations yielded (dark) surface band bending in the vicinity of 0.2-0.3 V and capture coefficient in the range of 10{sup -23}-10{sup -19} cm{sup 2}. Atomic layer deposition (ALD) was used to conformally deposit {approx_equal}10 nm of Al{sub 2}O{sub 3} on several devices. Photoconductivity, persistent photoconductivity, and subgap photoconductivity of the coated nanowires were increased in all cases. TaN ALD coatings showed a reduced effect compared to the Al{sub 2}O{sub 3} coated samples.

36 MATERIALS SCIENCE↗

Three-Dimensional Imaging Using Microcomputed Tomography For Studying Gaharu Morphology

To demonstrates the potential application of the high resolution X-ray micro-CT technique in the analysis of internal structure in Gaharu wood. Gaharu or internationally, Agar wood, is known for its fragrant resinous wood. The hardware device used in this study was an X-ray micro-CT scanner at Center of Tomography (UGCT), CT facility in Ghent University, Belgium. This technique allows the 3D investigation of the internal structure of the wood in a non-destructive way. Most of the data analysis was done with the software VG Studio Max and MATLAB. Here we present some preliminary results from three-dimensional images from a piece of high grade Gaharu. Micro-CT images of the specimens were obtained at 7 mum resolution. Besides a clear distinction between pores and material, some bright white areas occur in the reconstruction images. Not only the volume visualization is helpful, morphological parameters of open-pores and dark resins are calculated from these 3D data set. The micro-CT technique is a valid support for evaluating the pores structure and resin distribution in Gaharu.

36 MATERIALS SCIENCE↗

Effect of AlN buffer layer properties on the morphology and polarity of GaN nanowires grown by molecular beam epitaxy

Low-temperature AlN buffer layers grown via plasma-assisted molecular beam epitaxy on Si (111) were found to significantly affect the subsequent growth morphology of GaN nanowires. The AlN buffer layers exhibited nanowire-like columnar protrusions, with their size, shape, and tilt determined by the AlN V/III flux ratio. GaN nanowires were frequently observed to adopt the structural characteristics of the underlying AlN columns, including the size and the degree of tilt. Piezoresponse force microscopy and polarity-sensitive etching indicate that the AlN films and the protruding columns have a mixed crystallographic polarity. Convergent beam electron diffraction indicates that GaN nanowires are Ga-polar, suggesting that Al-polar columns are nanowire nucleation sites for Ga-polar nanowires. GaN nanowires of low density could be grown on AlN buffers that were predominantly N-polar with isolated Al-polar columns, indicating a high growth rate for Ga-polar nanowires and suppressed growth of N-polar nanowires under typical growth conditions. AlN buffer layers grown under slightly N-rich conditions (V/III flux ratio = 1.0 to 1.3) were found to provide a favorable growth surface for low-density, coalescence-free nanowires.

36 MATERIALS SCIENCE↗

Studies of photoconductivity and field effect transistor behavior in examining drift mobility, surface depletion, and transient effects in Si-doped GaN nanowires in vacuum and air

Variable intensity photoconductivity (PC) performed under vacuum at 325 nm was used to estimate drift mobility ({mu}) and density ({sigma}{sub s}) of negative surface charge for c-axis oriented Si-doped GaN nanowires (NWs). In this approach, we assumed that {sigma}{sub s} was responsible for the equilibrium surface band bending ( Empty-Set ) and surface depletion in the absence of illumination. The NWs were grown by molecular beam epitaxy to a length of approximately 10 {mu}m and exhibited negligible taper. The free carrier concentration (N) was separately measured using Raman scattering which yielded N = (2.5 {+-} 0.3) Multiplication-Sign 10{sup 17} cm{sup -3} for the growth batch studied under 325 nm excitation. Saturation of the PC was interpreted as a flatband condition whereby Empty-Set was eliminated via the injection of photogenerated holes. Measurements of dark and saturated photocurrents, N, NW dimensions, and dimensional uncertainties, were used as input to a temperature-dependent cylindrical Poisson equation based model, yielding {sigma}{sub s} in the range of (3.5 to 7.5) Multiplication-Sign 10{sup 11} cm{sup -2} and {mu} in the range of (850 to 2100) cm{sup 2}/(V s) across the (75 to 194) nm span of individual NW diameters examined. Data illustrating the spectral dependence and polarization dependence of the PC are also presented. Back-gating these devices, and devices from other growth batches, as field effect transistors (FETs) was found to not be a reliable means to estimate transport parameters (e.g., {mu} and {sigma}{sub s}) due to long-term current drift. The current drift was ascribed to screening of the FET back gate by injected positive charge. We describe how these gate charging effects can be exploited as a means to hasten the otherwise long recovery time of NW devices used as photoconductive detectors. Additionally, we present data illustrating comparative drift effects under vacuum, room air, and dry air for both back-gated NW FETs and top-gated NW MESFETs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Development of the gas-puff imaging diagnostic in the TEXTOR tokamak

Gas puff imaging (GPI) [S. J. Zweben, D. P. Stotler et al., Phys. Plasmas 9, 1981 (2002); R. J. Maqueda, G. A. Wurden et al., Rev. Sci. Instrum. 74, 2020 (2003)] is a powerful diagnostic that permits a two-dimensional measurement of turbulence in the edge region of a fusion plasma and is based on the observation of the local emission of a neutral gas, actively puffed into the periphery of the plasma. The developed in-vessel GPI telescope observes the emission from the puffed gas along local (at the puff) magnetic field lines. The GPI telescope is specially designed to operate in severe TEXTOR conditions and can be treated as a prototype for the GPI systems on next generation machines. Also, the gas puff nozzle is designed to have a lower divergence of the gas flow than previous GPI diagnostics. The resulting images show poloidally and radially propagating structures, which are associated with plasma blobs. We demonstrate that the local gas puff does not disturb plasma properties. Our results indicate also that the neutral gas emission intensity is more sensitive to the electron density than the electron temperature. Here, we present implementation details of the GPI system on TEXTOR and discuss some design and diagnostic issues related to the development of GPI systems in general.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Atom probe tomography evaporation behavior of C-axis GaN nanowires: Crystallographic, stoichiometric, and detection efficiency aspects

The field evaporation behavior of c-axis GaN nanowires was explored in two different laser-pulsed atom probe tomography (APT) instruments. Transmission electron microscopy imaging before and after atom probe tomography analysis was used to assist in reconstructing the data and assess the observed evaporation behavior. It was found that the ionic species exhibited preferential locations for evaporation related to the underlying crystal structure of the GaN and that the species which evaporated from these locations was dependent on the pulsed laser energy. Additionally, the overall stoichiometry measured by APT was significantly correlated with the energy of the laser pulses. At the lowest laser energies, the apparent composition was nitrogen-rich, while higher laser energies resulted in measurements of predominantly gallium compositions. The percent of ions detected (detection efficiency) for these specimens was found to be considerably below that shown for other materials, even for laser energies which produced the expected Ga:N ratio. The apparent stoichiometry variation and low detection efficiency appear to be a result of evaporation of Ga ions between laser pulses at the lowest laser energies and evaporation of neutral N{sub 2} species at higher laser energies. All of these behaviors are tied to the formation of nitrogen-nitrogen bonds on the tip surface, which occurred under all analysis conditions. Similar field evaporation behaviors are therefore expected for other materials where the anionic species readily form a strong diatomic bond.

36 MATERIALS SCIENCE↗

Imaging the p-n junction in a gallium nitride nanowire with a scanning microwave microscope

We used a broadband, atomic-force-microscope-based, scanning microwave microscope (SMM) to probe the axial dependence of the charge depletion in a p-n junction within a gallium nitride nanowire (NW). SMM enables the visualization of the p-n junction location without the need to make patterned electrical contacts to the NW. Spatially resolved measurements of S{sub 11}{sup ′}, which is the derivative of the RF reflection coefficient S{sub 11} with respect to voltage, varied strongly when probing axially along the NW and across the p-n junction. The axial variation in S{sub 11}{sup ′} effectively mapped the asymmetric depletion arising from the doping concentrations on either side of the junction. Furthermore, variation of the probe tip voltage altered the apparent extent of features associated with the p-n junction in S{sub 11}{sup ′} images.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Extracting the emitter orientation in organic light-emitting diodes from external quantum efficiency measurements

Emitter orientation will play a major role in future applications of organic light-emitting diodes due to its strong impact on the efficiency of the devices. Up to now, determining the orientation of transition dipole moments required elaborate angular-dependent measurements of the light emission pattern. In this paper, we present a simplified and straightforward method to extract the emitter orientation from external quantum efficiency measurements. We demonstrate the validity of the method on three different dye-doped emitting systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measurement of the electrostatic edge effect in wurtzite GaN nanowires

The electrostatic effect of the hexagonal corner on the electronic structure in wurtzite GaN nanowires (NWs) was directly measured using Kelvin probe force microscopy (KPFM). By correlating electrostatic simulations with the measured potential difference between the nanowire face and the hexagonal vertices, the surface state concentration and band bending of GaN NWs were estimated. The surface band bending is important for an efficient design of high electron mobility transistors and for opto-electronic devices based on GaN NWs. This methodology provides a way to extract NW parameters without making assumptions concerning the electron affinity. We are taking advantage of electrostatic modeling and the high precision that KPFM offers to circumvent a major source of uncertainty in determining the surface band bending.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Micro- and nanostructured electro-active polymer actuators as smart muscles for incontinence treatment

Treatments of severe incontinence are currently based on purely mechanical systems that generally result in revision after three to five years. Our goal is to develop a prototype acting in a natural-analogue manner as artificial muscle, which is based on electro-active polymers. Dielectric actuators have outstanding performances including millisecond response times, mechanical strains of more than 10 % and power to mass densities similar to natural muscles. They basically consist of polymer films sandwiched between two compliant electrodes. The incompressible but elastic polymer film transduces the electrical energy into mechanical work according to the Maxwell pressure. Available polymer films are micrometers thick and voltages as large as kV are necessary to obtain 10 % strain. For medical implants, polymer films should be nanometer thin to realize actuation below 48 V. The metallic electrodes have to be stretchable to follow the strain of 10 % and remain conductive. Recent results on the stress/strain behavior of anisotropic EAP-cantilevers have shown dependencies on metal electrode preparation. We have investigated tunable anisotropic micro- and nanostructures for metallic electrodes. They show a preferred actuation direction with improved stress-strain behavior. The bending of the cantilever has been characterized by the laser beam deflection method. The impact of the electrode on the effective Young's Modulus is measured using an Ultra Nanoindentation Tester with an integrated reference system for soft polymer surfaces. Once ten thousand layers of nanometer-thin EAP actuators are available, devices beyond the envisioned application will flood the market.

36 MATERIALS SCIENCE↗

Robustness of plasmonic angular momentum confinement in cross resonant optical antennas

Using a combination of photoemission electron microscopy and numerical simulations, we investigated the angular moment transfer in strongly enhanced optical near-fields of artificially fabricated optical antennas. The polarization dependence of the optical near-field enhancement has been measured in a maximum symmetric geometry, i.e., excitation by a normal incident planar wave. Finite-difference time-domain simulations for the realistic antenna geometries as determined by high-resolution electron microscopy reveal a very good agreement with experimental data. The agreement confirms that the geometrical asymmetries and inhomogeneities due to the nanoscale fabrication process preserve the circular polarization in the gap regions with strong near-field enhancement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Research Update: Stoichiometry controlled oxide thin film growth by pulsed laser deposition

The oxidation of species in the plasma plume during pulsed laser deposition controls both the stoichiometry as well as the growth kinetics of the deposited SrTiO{sub 3} thin films, instead of the commonly assumed mass distribution in the plasma plume and the kinetic energy of the arriving species. It was observed by X-ray diffraction that SrTiO{sub 3} stoichiometry depends on the composition of the background gas during deposition, where in a relative small pressure range between 10{sup −2} mbars and 10{sup −1} mbars oxygen partial pressure, the resulting film becomes fully stoichiometric. Furthermore, upon increasing the oxygen (partial) pressure, the growth mode changes from 3D island growth to a 2D layer-by-layer growth mode as observed by reflection high energy electron diffraction.

36 MATERIALS SCIENCE↗

A miniaturized, high frequency mechanical scanner for high speed atomic force microscope using suspension on dynamically determined points

One of the major limitations in the speed of the atomic force microscope (AFM) is the bandwidth of the mechanical scanning stage, especially in the vertical (z) direction. According to the design principles of “light and stiff” and “static determinacy,” the bandwidth of the mechanical scanner is limited by the first eigenfrequency of the AFM head in case of tip scanning and by the sample stage in terms of sample scanning. Due to stringent requirements of the system, simply pushing the first eigenfrequency to an ever higher value has reached its limitation. We have developed a miniaturized, high speed AFM scanner in which the dynamics of the z-scanning stage are made insensitive to its surrounding dynamics via suspension of it on specific dynamically determined points. This resulted in a mechanical bandwidth as high as that of the z-actuator (50 kHz) while remaining insensitive to the dynamics of its base and surroundings. The scanner allows a practical z scan range of 2.1 μm. We have demonstrated the applicability of the scanner to the high speed scanning of nanostructures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Combined frequency modulated atomic force microscopy and scanning tunneling microscopy detection for multi-tip scanning probe microscopy applications

A method which allows scanning tunneling microscopy (STM) tip biasing independent of the sample bias during frequency modulated atomic force microscopy (AFM) operation is presented. The AFM sensor is supplied by an electronic circuit combining both a frequency shift signal and a tunneling current signal by means of an inductive coupling. This solution enables a control of the tip potential independent of the sample potential. Individual tip biasing is specifically important in order to implement multi-tip STM/AFM applications. An extensional quartz sensor (needle sensor) with a conductive tip is applied to record simultaneously topography and conductivity of the sample. The high resonance frequency of the needle sensor (1 MHz) allows scanning of a large area of the surface being investigated in a reasonably short time. A recipe for the amplitude calibration which is based only on the frequency shift signal and does not require the tip being in contact is presented. Additionally, we show spectral measurements of the mechanical vibration noise of the scanning system used in the investigations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray microscopy of soft and hard human tissues

The simultaneous post mortem visualization of soft and hard tissues using absorption-based CT remains a challenge. If the photon energy is optimized for the visualization of hard tissue, the surrounding soft tissue components are almost X-ray transparent. Therefore, the combination with other modalities such as phase-contrast CT, magnetic resonance microscopy, and histology is essential to detect the anatomical features. The combination of the 2D and 3D data sets using sophisticated segmentation and registration tools allows for conclusions about otherwise inaccessible anatomical features essential for improved patient treatments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Stress measurements of planar dielectric elastomer actuators

Dielectric elastomer actuator (DEA) micro- and nano-structures are referred to artificial muscles because of their specific continuous power and adequate time response. The bending measurement of an asymmetric, planar DEA is described. The asymmetric cantilevers consist of 1 or 5 μm-thin DEAs deposited on polyethylene naphthalate (PEN) substrates 16, 25, 38, or 50 μm thick. The application of a voltage to the DEA electrodes generates an electrostatic pressure in the sandwiched silicone elastomer layer, which causes the underlying PEN substrate to bend. Optical beam deflection enables the detection of the bending angle vs. applied voltage. Bending radii as large as 850 m were reproducibly detected. DEA tests with electric fields of up to 80 V/μm showed limitations in electrode’s conductivity and structure failures. The actuation measurement is essential for the quantitative characterization of nanometer-thin, low-voltage, single- and multi-layer DEAs, as foreseen for artificial sphincters to efficiently treat severe urinary and fecal incontinence.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗