Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM POSITION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

A measurement of the proton’s spin structure function g2 at low Q2

JLab E08-027, a measurement of g2p and the longitudinal-transverse (LT) spin polarizability, successfully collected data from March to May, 2012. Nucleon spin structure study has been an active research area, which has attracted a very large effort from both experimentalists and theorists. The spin structure study for the last 2 decades has provided us with many exciting and often surprising results. Recently, new precision results in the low-to-intermediate momentum transfer Q2 region from JLab have provided extensive information on the nucleon structure in the confinement region and the transition region between asymptotic free to confinement. In particular, the extensive comparisons of experimental results with Chiral Perturbation Theory (the effective theory of QCD at low energy) calculations show general good agreements, but strong disagreement in the case of the neutron LT spin polarizability. This experiment completed the measurements of gp2 and the LT spin polarizability on the proton in the low-to-intermediate Q2 region. The experiment used a polarized proton (NH3) target for the first time in Hall A. Scattered electrons were detected by a pair of Hall A high resolution spectrometer (HRS) with a pair of septum magnets. To avoid too much depolarization of the target, beam current was limited to 50-100 nA during the experiment. Since the existing beam current monitors (BCMs), beam position monitors (BPMs) and calibration methods did not work at such a low current range, new BPM and BCM receivers were designed and used for current condition. A pair of super-harps and a tungsten calorimeter were installed to calibrate the BPMs and BCMs. To compensate for the effect of the 2.5/5T transverse magnet field, two chicane dipole magnets were installed. A pair of slow rasters were installed for the first time in Hall A, combining with a pair of fast raster. The standard Hall A DAQ system and the improved high resolution DAQ system were used to record the detector information and the helicity dependent beam information, respectively. In order to achieve the required accuracy of the beam position and angle and reconstruct them event by event at the target location, the data of the BPMs and harps were carefully analyzed. The final uncertainty of BCM after the calibration using the tungsten calorimeter is below 1%, which is important for the asymmetry extraction. Before the acceptance and the dilution factor are available, the models from fitting to the world data were used instead to extract the unpolarized cross section and the dilution factor. The longitudinal and transverse physics asymmetries were extracted and compared with the model, with the study of the radiative correction. The preliminary g1 and g2 results were then extracted using the measured asymmetry and the model.

Zhu, Pengjia↗

Bragg diffraction using a 100ps 17.5 keV x-ray backlighter and the Bragg Diffraction Imager

A new diagnostic for measuring Bragg diffraction from a laser-driven crystal using a 100ps 17.5 kV x-ray backlighter source is designed and tested successfully at the Omega EP laser facility on static Mo and Ta single crystal samples using a Mo Ka backlighter. The Bragg Diffraction Imager (BDI) consists of a heavily shielded enclosure and a precisely positioned beam block, attached to the main enclosure by an Aluminum arm. Image plate is used as the x-ray detector. The diffraction lines from Mo and Ta <222> planes are clearly detected with a high signal-to-noise using the 17.5 keV and 19.6 keV characteristic lines generated by a petawatt-driven Mo foil. This technique will be applied to shock and ramp-loaded single crystals on the Omega EP laser. Pulsed x-ray diffraction of shock- and ramp-compressed materials is an exciting new technique that can give insight into the dynamic behavior of materials at ultra-high pressure not achievable by any other means to date. X-ray diffraction can be used to determine not only the phase and compression of the lattice at high pressure, but by probing the lattice compression on a timescale equal to the 3D relaxation time of the material, information about dislocation mechanics, including dislocation multiplication rate and velocity, can also be derived. Both Bragg, or reflection, and Laue, or transmission, diffraction have been developed for shock-loaded low-Z crystalline structures such as Cu, Fe, and Si using nano-second scale low-energy implosion and He-{alpha} x-ray backlighters. However, higher-Z materials require higher x-ray probe energies to penetrate the samples, such as in Laue, or probe deep enough into the target, as in the case of Bragg diffraction. Petawatt laser-generated K{alpha} x-ray backlighters have been developed for use in high-energy radiography of dense targets and other HED applications requiring picosecond-scale burst of hard x-rays. While short pulse lasers are very efficient at producing high-energy x-rays, the characteristic x-rays produced in these thin foil targets are superimposed on a broad bremsstrahlung background and can easily saturate a detector if careful diagnostic shielding and experimental geometry are not implemented. A new diagnostic has been designed to measure Bragg diffraction from laser-driven crystal targets using characteristic x-rays from a short-pulse laser backlighter on the Omega EP laser. The Bragg Diffraction Imager, or BDI, is a TIM-mounted instrument consisting of a heavily shielded enclosure made from 3/8-inch thick Heavymet (W-Fe-Ni alloy) and a precisely positioned beam bock, attached to the main enclosure by an Aluminum arm. The beam block is made of 1-inch thick, Al-coated Heavymet and serves to block the x-rays directly from the petawatt backlight, while allowing the diffraction x-rays from the crystal to pass to the enclosure. A schematic of the BDI is shown in Fig. 1a. Image plates are used as the x-ray detector and are loaded through the top of the diagnostic in an Aluminum, light-tight cartridge. The front of the enclosure can be fitted with various filters to maximize the diffraction signal-to-noise.

42 ENGINEERING↗

SU-G-TeP4-11: Implementation of a Non-Measurement-Based Patient-Specific IMRT QA Program

Purpose: To implement a comprehensive non-measurement-based verification program for patient-specific IMRT QA Methods: Based on published guidelines, a robust IMRT QA program should assess the following components: 1) accuracy of dose calculation, 2) accuracy of data transfer from the treatment planning system (TPS) to the record-and-verify (RV) system, 3) treatment plan deliverability, and 4) accuracy of plan delivery. Results: We have implemented an IMRT QA program that consist of four components: 1) an independent re-calculation of the dose distribution in the patient anatomy with a commercial secondary dose calculation program: Mobius3D (Mobius Medical Systems, Houston, TX), with dose accuracy evaluation using gamma analysis, PTV mean dose, PTV coverage to 95%, and organ-at-risk mean dose; 2) an automated in-house-developed plan comparison system that compares all relevant plan parameters such as MU, MLC position, beam iso-center position, collimator, gantry, couch, field size settings, and bolus placement, etc. between the plan and the RV system; 3) use of the RV system to check the plan deliverability and further confirm using “mode-up” function on treatment console for plans receiving warning; and 4) implementation of a comprehensive weekly MLC QA, in addition to routine accelerator monthly and daily QA. Among 1200 verifications, there were 9 cases of suspicious calculations, 5 cases of delivery failure, no data transfer errors, and no failure of weekly MLC QA. These 9 suspicious cases were due to the PTV extending to the skin or to heterogeneity correction effects, which would not have been caught using phantom measurement-based QA. The delivery failure was due to the rounding variation of MLC position between the planning system and RV system. Conclusion: A very efficient, yet comprehensive, non-measurement-based patient-specific QA program has been implemented and used clinically for about 18 months with excellent results.

60 APPLIED LIFE SCIENCES↗

Overview of recent trends and developments for BPM systems

Beam position monitoring (BPM) systems are the workhorse of beam diagnostics for almost any kind of charged particle accelerator: linear, circular or transport-lines, operating with leptons, hadrons or heavy ions. BPMs are essential for beam commissioning, accelerator fault analysis and trouble shooting, machine optics, as well as lattice measurements, and finally, for accelerator optimization, in order to achieve the ultimate beam quality. This presentation summarizes the efforts of the beam instrumentation community on recent developments and advances on BPM technologies, i.e. BPM pickup monitors and front-end electronics (analog and digital). Principles, examples, and state-of-the-art status on various BPM techniques, serving hadron and heavy ion machines, sync light synchrotron's, as well as electron linacs for FEL or HEP applications are outlined.

43 PARTICLE ACCELERATORS↗

Research and Development on the Storage Ring Vacuum System for the APS Upgrade Project

A number of research and development activities are underway at Argonne National Laboratory to build confidence in the designs for the storage ring vacuum system required for the Advanced Photon Source Up-grade project (APS-U) [1]. The predominant technical risks are: excessive residual gas pressures during operation; insufficient beam position monitor stability; excessive beam impedance; excessive heating by induced electrical surface currents; and insufficient operational reliability. Present efforts to mitigate these risks include: building and evaluating mockup assemblies; performing mechanical testing of chamber weld joints; developing computational tools; investigating design alternatives; and performing electrical bench measurements. Status of these activities and some of what has been learned to date will be shared.

APS-U, APS UPGRADE PROJECT, STORAGE RING VACUUM SY↗

High intensity proton injector for facility of antiproton and ion research

The high current ion source with the low energy beam transport (LEBT) will serve as injector into the proton LINAC to provide primary proton beam for the production of antiprotons. The pulsed ion source developed and built in CEA/Saclay operates with a frequency of 2.45 GHz based on ECR plasma production with two coils with 87.5 mT magnetic field necessary for the electron cyclotron resonance. The compact LEBT consists of two solenoids with a maximum magnetic field of 500 mT including two integrated magnetic steerers to adjust the horizontal and vertical beam positions. The total length of the compact LEBT is 2.3 m and was made as short as possible to reduced emittance growth along the beam line. To measure ion beam intensity behind the pentode extraction system, between solenoids and at the end of the beam line, two current transformers and a Faraday cup are installed. To get information about the beam quality and position, the diagnostic chamber with different equipment will be installed between the two solenoids. This article reports the current status of the proton injector for the facility of antiproton and ion research.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement and Simulation of Interpenetration and DC Accumulation of Beam in the University of Maryland Electron Ring

The University of Maryland Electron Ring (UMER) is a facility to study the long-path length physics of a highly space-charge dominated beam. Optimizing the ring characteristics to maximize beam lifetime has required an understanding of both the longitudinal and transverse dynamics of the beam and how they are coupled. A combination of experimental and numerical evidence is presented to show that front end of the injected bunch is accelerated by longitudinal space charge forces while the back of the same bunch is similarly decelerated leading to a longitudinal expansion of the injected bunch. This continues until the head overtakes the tail of the preceding turn. A significant portion of the apparent beam current decay is actually due to the merging of the head and tail, which results in a difficult-to-measure DC component of the beam. We also present a novel measurement technique to examine this longitudinal behavior that uses a voltage pulse applied between the horizontal plates at a beam position monitor. The pulse amplitude is sufficient to deflect the beam so that it intercepts the chamber wall. The resulting notch in the beam current, which can be varied in time, allows reconstruction of the DC component. Combined with simulations of the longitudinal and transverse beam characteristics this procedure provides data that can be used to understand the underlying beam dynamics.

43 PARTICLE ACCELERATORS↗

Method and system for controlling the position of a beam of light

An method and system for laser beam tracking and pointing is based on a conventional position sensing detector (PSD) or quadrant cell but with the use of amplitude-modulated light. A combination of logarithmic automatic gain control, filtering, and synchronous detection offers high angular precision with exceptional dynamic range and sensitivity, while maintaining wide bandwidth. Use of modulated light enables the tracking of multiple beams simultaneously through the use of different modulation frequencies. It also makes the system resistant to interfering light sources such as ambient light. Beam pointing is accomplished by feeding back errors in the measured beam position to a beam steering element, such as a steering mirror. Closed-loop tracking performance is superior to existing methods, especially under conditions of atmospheric scintillation.

47 OTHER INSTRUMENTATION↗

Linac Alignment Algorithm: Analysis on 1-to-1 Steering

In a linear accelerator, it is important to achieve a good alignment between all of its components (such as quadrupoles, RF cavities, beam position monitors et al.), in order to better preserve the beam quality during acceleration. After the survey of the main linac components, there are several beam-based alignment (BBA) techniques to be applied, to further optimize the beam trajectory and calculate the corresponding steering magnets strength. Among these techniques the most simple and straightforward one is the one-to-one (1-to-1) steering technique, which steers the beam from quad center to center, and removes the betatron oscillation from quad focusing. For a future linear collider such as the International Linear Collider (ILC), the initial beam emittance is very small in the vertical plane (flat beam with {gamma}{epsilon}{sub y} = 20-40nm), which means the alignment requirement is very tight. In this note, we evaluate the emittance growth with one-to-one correction algorithm employed, both analytically and numerically. Then the ILC main linac accelerator is taken as an example to compare the vertical emittance growth after 1-to-1 steering, both from analytical formulae and multi-particle tracking simulation. It is demonstrated that the estimated emittance growth from the derived formulae agrees well with the results from numerical simulation, with and without acceleration, respectively.

43 PARTICLE ACCELERATORS↗

Individual Beam Size And Length Measurements at the SLC Interaction Point Derived From the Beam Energy Loss During a Beam Beam Deflection Scan

At the Interaction Point (IP) of the SLC Final Focus, beam-beam deflection scans routinely provide a measurement of the sum in quadrature of the electron and positron transverse beam sizes, but no information on the individual beam sizes. During the 1996 SLC run, an upgrade to the Final Focus beam position monitor system allowed a first measurement of the absolute beam energy loss of both beams on each step of the deflection scan. A fit to the energy loss distributions of the two beams provides a measurement not only of the individual transverse beam sizes at the IP but also of the individual bunch lengths.

43 PARTICLE ACCELERATORS↗

An orbit fit program for localizing errors in RHIC

Many errors in an accelerator are evidenced as transverse kicks to the beam which distort the beam trajectory. Therefore, the information of the errors are imprinted in the distorted orbits, which are different from what would be predicted by the optics model. In this note, we introduce an algorithm for fitting the orbit based on an on-line optics model. By comparing the measured and fitted orbits, we first present results validating the algorithm. We then apply the algorithm and localize the location of the elusive source of vertical diurnal variations observed in RHIC. The difference of two trajectories (linear accelerator) or closed orbits (storage ring) should match exactly a betatron oscillation, which is predictable by the optics model, in an ideal machine. However, in the presence of errors, the measured trajectory deviates from prediction since the model is imperfect. Comparison of measurement to model can be used to detect such errors. To do so the initial conditions (phase space parameters at any point) must be determined which can be done by comparing the difference orbit to prediction using only a few beam position monitors (BPMs). The fitted orbit can be propagated along the beam line based on the optics model. Measurement and model will agree up to the point of an error. The error source can be better localized by additionally fitting the difference orbit using downstream BPMs and back-propagating the solution. If one dominating error source exist in the machine, the fitted orbit will deviate from the difference orbit at the same point.

43 PARTICLE ACCELERATORS↗

Vertical Instability at IPNS RCS.

The rapid cycling synchrotron (RCS) of the intense pulsed neutron source (IPNS) at ANL accelerates > 3.0 times 10{sup 12} protons from 50 MeV to 450 MeV with 30-Hz repetition frequency. During the acceleration cycle, the rf frequency varies from 2.21 MHz to 5.14 MHz. Presently, the beam current is limited by a vertical instability. By analyzing turn-by-turn beam position monitor (BPM) data, large- amplitude mode 0 and mode 1 vertical beam centroid oscillations were observed in the later part of the acceleration cycle. The oscillations start in the tail of the bunch, build up, and remain localized in the tail half of the bunch. This vertical instability was compared with a head-tail instability that was intentionally induced in the RCS by adjusting the trim sextupoles. It appears that our vertical instability is not a classical head-tail instability [1]. More data analysis and experiments were performed to characterize the instability.

43 PARTICLE ACCELERATORS↗

SU-E-T-230: Creating a Large Number of Focused Beams with Variable Patient Head Tilt to Improve Dose Fall-Off for Brain Radiosurgery

Purpose: To develop a treatment delivery and planning strategy by increasing the number of beams to minimize dose to brain tissue surrounding a target, while maximizing dose coverage to the target. Methods: We analyzed 14 different treatment plans via Leksell PFX and 4C. For standardization, single tumor cases were chosen. Original treatment plans were compared with two optimized plans. The number of beams was increased in treatment plans by varying tilt angles of the patient head, while maintaining original isocenter and the beam positions in the x-, y- and z-axes, collimator size, and beam blocking. PFX optimized plans increased beam numbers with three pre-set tilt angles, 70, 90, 110, and 4C optimized plans increased beam numbers with tilt angles increasing arbitrarily from range of 30 to 150 degrees. Optimized treatment plans were compared dosimetrically with original treatment plans. Results: Comparing total normal tissue isodose volumes between original and optimized plans, the low-level percentage isodose volumes decreased in all plans. Despite the addition of multiple beams up to a factor of 25, beam-on times for 1 tilt angle versus 3 or more tilt angles were comparable (<1 min.). In 64% (9/14) of the studied cases, the volume percentage decrease by >5%, with the highest value reaching 19%. The addition of more tilt angles correlates to a greater decrease in normal brain irradiated volume. Selectivity and coverage for original and optimized plans remained comparable. Conclusion: Adding large number of additional focused beams with variable patient head tilt shows improvement for dose fall-off for brain radiosurgery. The study demonstrates technical feasibility of adding beams to decrease target volume.

60 APPLIED LIFE SCIENCES↗

LANSCE beam instrumentation and the LANSCE refurbishment project

The heart of the LANSCE accelerator complex consists of Cockroft-Walton-type injectors, a drift-tube linac (DTL) and a side-coupled linac (CCL). These systems are approaching 40 years of age and a project to re-establish high-power capability and to extend the lifetime is underway. Many of the present beam diagnostic systems are difficult to maintain, and the original beam position monitors don't provide any data at all. These deficiencies hamper beam tuning and trouble-shooting efforts. One thrust of the refurbishment project is to restore reliable operation of the diagnostic systems. This paper describes the present diagnostics systems and their limitations and the envisaged next-generation systems. The emphasis will be on the uses and requirements for the systems rather than the solutions and engineering aspects of the refurbishment.

43 PARTICLE ACCELERATORS↗

Linear and chromatic optics measurements at RHIC

Measurements of chromatic beta-beating were carried out for the first time in the RHIC accelerator during Run 2009. The analysis package developed for the LHC was used to extract the off-momentum optics for injection and top energy. Results from the beam experiments and compassion to the optics model are presented. The primary goal of the RHIC experiments were execute an on-line measurement of the optics using the tools developed for the LHC. Turn-by-turn BPM trajectories (typically 1000 turns) acquired immediately after an external dipole kick are numerically analyzed to determine the optical parameters at the location of the beam position monitors (BPMs). For chromatic optics, a similar analysis, but on a beam with finite momentum offset(s). Each optical measurement typically is calculated from multiple data sets to capture statistical variations and ensure reproducibility. The procedure of measurement and analysis is detailed in ref [1, 2]. Two dedicated experiments were performed at RHIC with protons during Run 2009. The first at injection energy and optics and the other at 250 GeV and squeezed optics. The basic RHIC parameters relevant for the two experiments are listed in Table 1.

43 PARTICLE ACCELERATORS↗

Conditioning of BPM pickup signals for operations of the Duke storage ring with a wide range of single-bunch current

The Duke storage ring is a dedicated driver for the storage ring based oscillator free-electron lasers (FELs), and the High Intensity Gamma-ray Source (HIGS). Furthermore, it is operated with a beam current ranging from about 1 mA to 100 mA per bunch for various operations and accelerator physics studies. High performance operations of the FEL and γ-ray source require a stable electron beam orbit, which has been realized by the global orbit feedback system. As a critical part of the orbit feedback system, the electron beam position monitors (BPMs) are required to be able to precisely measure the electron beam orbit in a wide range of the single-bunch current. However, the high peak voltage of the BPM pickups associated with high single-bunch current degrades the performance of the BPM electronics, and can potentially damage the BPM electronics. A signal conditioning technique using low pass filters is developed to reduce the peak voltage to protect the BPM electronics, and to make the BPMs capable of working with a wide range of single-bunch current. Simulations and electron beam based tests are performed. The results show that the Duke storage ring BPM system is capable of providing precise orbit measurements to ensure highly stable FEL and HIGS operations.

43 PARTICLE ACCELERATORS↗