Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM BUNCHING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Two design of the S4.BEN01 magnet for the CBETA splitter/merger

The splitter/merger section of the CBETA project [1] consists of 4 beam lines as shown in Fig. 1. Two of the functions of the splitter’s/merger’s lines is to match the beam parameters at the exit of the Energy Recovery Linac (ERL) to the beam parameters at the entrance of the Fixed Field Alternating Gradient (FFAG) arc, and also place the reference particles of the beam bunches at the entrance of the FFAG arc on specified trajectories according to their energies. In this technical note we are presenting results from the 2D and 3D electromagnetic analysis of the S4.BEN01 magnet which is one of the dipole magnets of the 150 MeV line of the splitter/merger. In particular we present results from two designs of the S4.BEN01 magnet, one based on iron dominated current-excited magnet, and the other design based on Halbach-type permanent magnet. An evaluation of the two designs will be given in the section under “conclusion”.

43 PARTICLE ACCELERATORS↗

Electric Field Effects on the Muon Anomalous Precession Frequency in the Fermilab Muon g -2 Experiment [Slides]

The muon anomalous magnetic moment ( g -2) has played an important role in constraining physics beyond the Standard Model for many years. The Fermilab Muon g -2 Experiment has a goal to measure it to unprecedented precision: 0.14 ppm. To achieve this goal, we need to understand the systematic uncertainties associated with beam dynamics. We will present a study of the electric field correction to the muon anomalous precession frequency based on fast rotation analysis, which uses the evolution of beam bunch structure to determine the muon momentum distribution.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design of a Linear-Quadratic-Gaussian Controller for a Single-Cavity Rigid-Bunch RF-System

Linear quadratic Gaussian (LQG) controllers have the potential to reduce rf-system noise in synchrotron storage rings below what is ordinarily achieved with conventional proportional-integral (PI) controllers. But realizing this possibility requires careful design of the controller to match the characteristics of the machine (which is simplified by top-off operation) and is computationally demanding. This study develops computational methods for the construction of LQG controllers for discrete-time models of single-cavity rf systems coupled to rigid-bunch beams, and driven by rf amplifier noise. Matlab’s control-systems toolbox (CST) is the primary computational tool, particularly for the steady-state Kalman estimator, the LQR feedback, and the LQG controller. Of the rf signals available to the controller, a subset is chosen that results in a stable, effective, and economical controller. This floating-point LQG controller is then analyzed to establish resolutions of state variables, ADCs, DACs, and matrix coefficients that, in a fixed-point controller, provided essentially undiminished performance. A Simulink model computes beam noise in linear and nonlinear rf-system models with floating-point, fixed-point, and proportional-integral controllers. This machinery is applied to NSLS-II, CLS, and NSLS VUV rings showing bandwidth and amplifier noise suppression beyond what a PI controller can do. Required signal resolutions are surprisingly moderate. Testing and tuning with response functions computed by Vlasov simulations are performed. Thoughts are given on the further validation and tuning of the linearized model by machine measurements, DSP implementations, and future work.

36 MATERIALS SCIENCE↗

Investigation of electron dynamics in the magnetosphere with electron beams injected from sounding rockets

The Electron Echo experiments are described which were conducted with three sounding rockets to study the basic mechanisms by which electrons precipitate from the geomagnetic field to produce auroral X-rays during periods of geomagnetic activity. Echo I (1970) injected electron pulses at low latitude and successfully measured the returning pulses from the conjugate region. Echo II (1972) was launched from high latitude, studied the interaction of electron beams with background radiation as well as beam motion near the rocket, and obtained evidence for a beam plasma instability. Echo III (1974) detected a series of conjugate echoes during the presence of a strong convective field in the magnetosphere and conducted an unsuccessful search for beam bunching at the local plasma frequency. It is shown that the electric field measurement in the ionosphere, using incoherent backscatter radar and detectors on the rocket, was transferred to the equatorial plane as though field lines were equipotentials.

Winckler, J. R.↗

The EMMA Accelerator, a Diagnostic Systems Overview

The 'EMMA' Non-Scaling Fixed Field Alternating Gradient (ns-FFAG) international project is currently being commissioned at Daresbury Laboratory, UK. This accelerator has been equipped with a number of diagnostic systems to facilitate this. These systems include a novel time-domain-multiplexing BPM system, moveable screen systems, a time-of-flight instrument, Faraday cups, and injection/extraction tomography sections to analyze the single bunch beams. An upgrade still to implement includes the installation of wall current monitors. This paper gives an overview of these systems and shows some data and results from the diagnostics that have contributed to the successful demonstration of a serpentine acceleration by this novel accelerator.

43 PARTICLE ACCELERATORS↗

Precision Magnet Measurements for X-Band Accelerator Quadrupole Triplets

An X-band test station is being developed at LLNL to investigate accelerator optimization for future upgrades to mono-energetic gamma-ray (MEGa-Ray) technology at LLNL. Beamline magnets will include an emittance compensation solenoid, windowpane steering dipoles, and quadrupole magnets. Demanding tolerances have been placed on the alignment of these magnets, which directly affects the electron bunch beam quality. A magnet mapping system has been established at LLNL in order to ensure the delivered magnets match their field specification, and the mountings are aligned and capable of reaching the specified alignment tolerances. The magnet measurement system will be described which uses a 3-axis Lakeshore gauss probe mounted on a 3-axis translation stage. Alignment accuracy and precision will be discussed, as well as centering measurements and analysis. The dependence on data analysis over direct multi-pole measurement allows a significant improvement in useful alignment information. Detailed analysis of measurements on the beamline quadrupoles will be discussed, including multi-pole content both from alignment of the magnets, and the intrinsic level of multi-pole magnetic field.

42 ENGINEERING↗

Microbunching phenomena in LCLS-II

The microbunching instability has long been recognized as a potential limiting factor to the performance of X-ray FELs. It is of particular relevance in LCLS-II due, in part, to a layout that includes a long bypass beamline between the Linac and the undulators. Here we focus on two aspects of the instability that highlight the importance of 3D effects.

43 PARTICLE ACCELERATORS↗

CSR Impedance for Non-Ultrarelativistic Beams

For the analysis of the coherent synchrotron radiation (CSR)-induced microbunching gain in the low energy regime, such as when a high-brightness electron beam is transported through a low-energy merger in an energy-recovery linac (ERL) design, it is necessary to extend the CSR impedance expression in the ultrarelativistic limit to the non-ultrarelativistic regime. This paper presents our analysis of CSR impedance for general beam energies.

43 PARTICLE ACCELERATORS↗

CSR induced microbunching gain estimation including transient effects in transport and recirculation arcs

The coherent synchrotron radiation (CSR) of a high brightness electron beam traversing a series of dipoles, such as transport or recirculation arcs, may result in the microbunching instability (μBI). To accurately quantify the direct consequence of this effect, we further extend our previously developed semi-analytical Vlasov solver to include more relevant coherent radiation models than the steady-state free-space CSR impedance, such as the entrance and exit transient effects derived from upstream beam entering to and exiting from individual dipoles. The resultant microbunching gain functions and spectra for our example lattices are presented and compared with particle tracking simulation. Some underlying physics with inclusion of these effects are also discussed.

43 PARTICLE ACCELERATORS↗

Dielectric-plate-implanted Higher Order Mode (HOM) Waveguide for High Intensity Multi-beam Device Application

A mode-selective oversized RF-beam channel has been investigated for high intensity multi-beam devices. Implanting the equi-spaced dielectric plates at the transverse positions where longitudinal electric fields of a HOM are minimal in the mic ro-metallic structure strongly suppresses all lower energy modes and other wakefield modes. The dielectric lattice captures only a single HOM of the wavelengths that correspond to the plate spacing. Electromagnetic simulations have shown that the lower en ergy modes, TE10 and TE20 modes, are suppressed down to < ~ -60 dB by two plate loads, while TE310-mode prominently propagates through the 2 mm long waveguide only with 4 dB (= -2dB/mm) at 1 THz. The numerical calculation indicated that the TE30 mode has ~ a few times higher Q than the lower energy modes. The strong single mode selectivity has been extensively looked into with a more highly overmoded structure. Feasibility analysis of the HOM structure for multi-beam device application is under investiga tion. Particle-in-cell (PIC) simulation has shown coherent beam bunching and energy gain from THz driving signal.

43 PARTICLE ACCELERATORS↗

Using a TE011 Cavity as a Magnetic Momentum Monitor

The Jefferson Lab Electron-Ion Collider (JLEIC) design relies on cooling of the ion beam with bunched electron beam constrained in a pair of long solenoids. The high current cooling electron beam needs to be generated in a magnetized electron source, and the beam's magnetization needs to be maintained during the acceleration and transport to the cooling channel. A non-invasive real time monitoring system is highly desired to quantify electron beam magnetization. The authors propose to use a passive copper RF cavity in TE011 mode as such a monitor. In this paper, we present the mechanism and scaling law of this device, as well as the design and preliminary test results of the prototype cavity.

Guo, Jiquan↗

Feedback Techniques and Ecloud Instabilites - Design Estimates

The SPS at high intensities exhibits transverse single-bunch instabilities with signatures consistent with an Ecloud driven instability. While the SPS has a coupled-bunch transverse feedback system, control of Ecloud-driven motion requires a much wider control bandwidth capable of sensing and controlling motion within each bunched beam. This paper draws beam dynamics data from the measurements and simulations of this SPS instability, and estimates system requirements for a feedback system with 2-4 GS/sec. sampling rates to damp Ecloud-driven transverse motion in the SPS at intensities desired for high-current LHC operation.

43 PARTICLE ACCELERATORS↗

Resonant Kicker System Development at SLAC

The design and installation of the Linear Coherent Light Source [1] at SLAC National Accelerator Laboratory has included the development of a kicker system for selective beam bunch dumping. The kicker is based on an LC resonant topology formed by the 50 uF energy storage capacitor and the 64 uH air core magnet load which has a sinusoidal pulse period of 400us. The maximum magnet current is 500 A. The circuit is weakly damped, allowing most of the magnet energy to be recovered in the energy storage capacitor. The kicker runs at a repetition rate of 120Hz. A PLC-based control system provides remote control and monitoring of the kicker via EPICS protocol. Fast timing and interlock signals are converted by discrete peak-detect and sample-hold circuits into DC signals that can be processed by the PLC. The design and experimental characterization of the system are presented.

43 PARTICLE ACCELERATORS↗

Cyclotron Resonances in Electron Cloud Dynamics

A new set of resonances for electron cloud dynamics in the presence of a magnetic field has been found. For short beam bunch lengths and low magnetic fields where l{sub b} << 2{pi}{omega}{sub c}, (l{sub b} = bunch duration, {omega}{sub c} = non-relativistic cyclotron frequency) resonances between the bunch frequency and harmonics of the cyclotron frequency cause an increase in the electron cloud density in narrow ranges of magnetic field near the resonances. For ILC parameters the increase in the density is up to a factor {approx} 3, and the spatial distribution of the electrons is broader near resonances, lacking the well-defined density 'stripes' of multipactoring found for non-resonant cases. Simulations with the 2D computer code POSINST, as well as a single-particle tracking code, were used to elucidate the physics of the dynamics. The resonances are expected to affect the electron cloud dynamics in the fringe fields of conventional lattice magnets and in wigglers, where the magnetic fields are low. Results of the simulations, the reason for the bunch-length dependence, and details of the dynamics will be discussed.

43 PARTICLE ACCELERATORS↗

Cyclotron Resonances in Electron Cloud Dynamics

A new set of resonances for electron cloud dynamics in the presence of a magnetic field has been found. For short beam bunch lengths and low magnetic fields where lb<< 2pi c/omega c (with lb = bunch length, omega c = non-relativistic cyclotron frequency) resonances between the bunch frequency and harmonics of the electron cyclotron frequency cause an increase in the electron cloud density in narrow ranges of magnetic field near the resonances. For ILC parameters the increase in the density is up to a factor ~;;3, and the spatial distribution of the electrons is broader near resonances, lacking the well-defined vertical density"stripes" found for non-resonant cases. Simulations with the 2D computer code POSINST, as well as a single-particle tracking code, were used to elucidate the physics of the dynamics. The existence of the resonances has been confirmed in experiments at PEP-II. The resonances are expected to affect the electron cloud dynamics in the fringe fields of conventional lattice magnets and in wigglers, where the magnetic fields are low. Results of the simulations and experimental observations, the reason for the bunch-length dependence, and details of the dynamics are discussed here.

43 PARTICLE ACCELERATORS↗

Feedback techniques and SPS Ecloud instabilities - design estimates

The SPS at high intensities exhibits transverse single-bunch instabilities with signatures consistent with an Ecloud driven instability. While the SPS has a coupled-bunch transverse feedback system, control of Ecloud driven motion requires a much wider control bandwidth capable of sensing and controlling motion within each bunched beam. This paper draws beam dynamics data from the measurements and simulations of this SPS instability, and estimates system requirements for a feedback system with 2-4 GS/sec. sampling rates to damp Ecloud-driven transverse motion in the SPS at intensities desired for high-current LHC operation.

43 PARTICLE ACCELERATORS↗

RHIC PERFORMANCE DURING THE FY10 200 GeV Au+Au HEAVY ION RUN

Since the last successful RHIC Au+Au run in 2007 (Run-7), the RHIC experiments have made numerous detector improvements and upgrades. In order to benefit from the enhanced detector capabilities and to increase the yield of rare events in the acquired heavy ion data a significant increase in luminosity is essential. In Run-7 RHIC achieved an average store luminosity of <L> = 12 x 10{sup 26} cm{sup -2} s{sup -1} by operating with 103 bunches (out of 111 possible), and by squeezing to {beta}* = 0.85 m. This year, Run-10, we achieved <L> = 20 x 10{sup 26} cm{sup -2} s{sup -1}, which put us an order of magnitude above the RHIC design luminosity. To reach these luminosity levels we decreased {beta}* to 0.75 m, operated with 111 bunches per ring, and reduced longitudinal and transverse emittances by means of bunched-beam stochastic cooling. In addition we introduced a lattice to suppress intra-beam scattering (IBS) in both RHIC rings, upgraded the RF control system, and separated transition crossing times in the two rings. We present an overview of the changes and the results of Run-10 performance.

43 PARTICLE ACCELERATORS↗