Design and performance of an experimental annular turbojet combustor with high-velocity- air admission through one wall
Experimental annular turbojet combustor with high velocity air admission through one wall
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Experimental annular turbojet combustor with high velocity air admission through one wall
A short annular diffuser equipped with wall bleed (suction)capability was evaluated at inlet Mach numbers of 0.186 to 0.5. The diffuser had an area ratio of 4.0 and a length-to-inlet height ratio of 1.6. Test results show that the exit velocity profiles, typical of annular jet flow without suction, could be considerably flattened by application of wall suction. This improved performance was also reflected in diffuser effectiveness (static-pressure recovery) and total-pressure loss results. At the inlet Mach number of 0.5 diffuser static-pressure recovery is equal to or better than at lower inlet Mach numbers for comparable suction rates.
An annular jet flow of liquid surrounding a flow of gas at its core is extremely unstable. Axisymmetric oscillations arise spontaneously, and grow with such rapidity along the axial dimension that a pinch-off of the liquid and an encapsulation of the core gas occurs within as few as four jet diameters. The shells which result thereby may be described as thick-wall bubbles, for which van der Waals forces are unimportant. A description is given of the fluid dynamic processes by which the shells are formed, and of means for preserving and promoting the geometrical of the product. The forming of metallic shells is mentioned.
An experimental study of three variations of a ventral nozzle system for supersonic short-takeoff and vertical-landing (SSTOVL) aircraft was performed at the NASA LeRC Powered Lift Facility. These test results include the effects of an annular duct flow into the ventral duct, a blocked tailpipe, and a short ventral duct length. An analytical study was also performed on the short ventral duct configuration using the PARC3D computational dynamics code. Data presented include pressure losses, thrust and flow performance, internal flow visualization, and pressure distributions at the exit plane of the ventral nozzle.
An experimental study of three variations of a ventral nozzle system for supersonic short-takeoff and vertical-landing (SSTOVL) aircraft was performed at the NASA LeRC Powered Lift Facility. These test results include the effects of an annular duct flow into the ventral duct, a blocked tailpipe, and a short ventral duct length. An analytical study was also performed on the short ventral duct configuration using the PARC3D computational dynamics code. Data presented include pressure losses, thrust and flow performance, internal flow visualization, and pressure distributions at the exit plane of the ventral nozzle.
Microsecond sparks and the resulting plume of hot gas/plasma were examined against a parametric pressure-distance matrix. Schlieren imaging is used to capture the spatial and temporal location of spark discharge exhaust for two milliseconds. Low pressure and larger gap widths created the largest size and intensity signal for the spark-affected plumes. Experimental exit-plume velocities trend well with analytic predictions using a mean pressure between the chamber and atmospheric conditions. Due to the quadratic relation of the annulus area and gap width, larger gap width velocities are more accurately represented by analytic predictions using atmospheric pressure as the larger exit area restricts the flow less. The same pressure adjustment, when applied to breakdown voltages, improves data alignment with Paschen’s Curve.
This study presents steam condensation scaled experiments and semi-empirical models in presence of nitrogen (N)—a noncondensable gas (NCG), simulating air in the reactor containment—to support water-cooled small modular reactors (SMRs) passive containment cooling system (PCCS) design and analysis. Previous experimental studies on PCCS are focused on fixed and smaller tube (mostly 2-in.) geometries and specific test condition variations, bringing challenges with geometric scaling and mismatching with SMR prototypic design. To address these challenges, this study presents steam condensation test dataset obtained from three scaled test sections of 1-, 2-, and 4-in.-diameter steam condensers with an annular/jacket cooling of 2-, 3-, and 6 in.-diameter tubes, respectively. Test data were collected for steam ranges from 58 to 63 kg/hr., and NCG flow of 4.4 to 13.3 kg/hr. Annular cooling water flow was varied to obtain required testing conditions of saturated steam inlet and fully condensed outlet. Axial temperature test data of bulk cooling water, steam and condensate were collected by thermocouples for three test sections and various steam-NCG mixing/testing conditions. A standard data reduction method was adopted—utilizing iterative and nodalized mass and heat transfer calculation—to estimate axial local heat fluxes, heat transfer coefficients (HTCs), condensation rates, film thickness, and Nusselt number. Based on the obtained dataset semi-empirical model results—a ratio of experimental and Nusselt’s theoretical HTC are presented. Such results and findings are supportive of developing scaled-up testing facility, to enable model validations and accelerate next generation of reactors development and deployment
This study presents steam condensation scaled experiments and semi-empirical models in presence of nitrogen--a noncondensable gas (NCG), simulating air in the reactor containment--to support water-cooled small modular reactors (SMRs) passive containment cooling system (PCCS) design and analysis. Previous experimental studies on PCCS are focused on fixed and smaller tube (mostly 2-in.) geometries and specific test condition variations, bringing challenges with geometric scaling and mismatching with SMR prototypic design. To address these challenges, this study presents steam condensation test dataset obtained from three scaled test sections of 1-, 2-, and 4-in.-diameter steam condensers with an annular/jacket cooling of 2-, 3-, and 6 in.-diameter tubes, respectively. Test data were collected for steam ranges from 58 to 63 kg/hr., and NCG flow of 4.4 to 13.3 kg/hr. Annular cooling water flow was varied to obtain required testing conditions of saturated steam inlet and fully condensed outlet. Axial temperature test data of bulk cooling water, steam and condensate were collected by thermocouples for three test sections and various steam-NCG mixing/testing conditions. A standard data reduction method was adopted--utilizing iterative and nodalized mass and heat transfer calculation to estimate axial local heat fluxes, heat transfer coefficients (HTCs), condensation rates, film thickness, and Nusselt number. Based on the obtained dataset semi-empirical model results--a ratio of experimental and Nusselt's theoretical HTC are presented. Such results and findings are supportive of developing scaled-up testing facility, to enable model validations and accelerate next generation of reactors development and deployment.
A method has recently been developed for calculating the flow over a subsonic nacelle at zero angle of attack. The method makes use of annular wing theory and boundary-layer theory and has shown good agreement with both experimental data and more complex theoretical solutions. The method permits variation of the mass flow by changing the size of a center body.
A burner for the investigation of lean stratified premixed flames propagating in intense isotropic turbulence has been developed. Lean pre-mixtures of methane at different equivalence ratios were divided between two concentric co-flows to obtain annular stratification. Turbulence generators were used to control the level of turbulence intensity in the oncoming flow. A third annular weakly swirling airflow provided the flame stabilisation mechanism. A fundamental characteristic was that flame stabilisation did not rely on flow recirculation. The flames were maintained at a position where the local mass flux balanced the burning rate, resulting in a freely propagating turbulent flame front. The absence of physical surfaces in the vicinity of the flame provided free access for laser diagnostics. Stereoscopic Planar Image Velocimetry (SPIV) was applied to obtain the three components of the instantaneous velocity vectors on a vertical plane above the burner at the point of flame stabilisation. The instantaneous temperature fields were determined through Laser Induced Rayleigh (LIRay) scattering. Planar Laser Induced Fluorescence (PLIF) of acetone was used to calculate the average equivalence ratio distributions. Instantaneous turbulent burning velocities were extracted from SPIV results, while flame curvature and flame thermal thickness were calculated using the instantaneous temperature fields. The PDFs of these quantities were analysed to consider the separate influence of equivalence ratio stratification and turbulence. Increased levels of turbulence resulted in the expected higher turbulent burning velocities and flame front wrinkling. Flames characterised by higher fuel gradients showed higher turbulent burning velocities. Increased fuel concentration gradients gave rise to increased flame wrinkling, particularly when associated with positive small radius of curvature. (author)
Performance evaluation of annular plug and expansion-deflection nozzles including external flow effects at transonic Mach numbers
An improved electrothermal device is disclosed. An electrothermal thruster utilizes a generally cylindrical heat exchanger chamber to convert electricity to heat which raises the propellant temperature. A textured, high emissivity heat element radiatively transfers heat to the inner wall of this chamber that is ion beam morphologically controlled for high absorptivity. This, in turn, raises the temperature of a porous heat exchanger material in an annular chamber surrounding the cylindrical chamber. Propellant gas flows through the annular chamber and is heated by the heat exchanger material.
Hydraulic conductivities of volcanic and carbonate lithologic units at the Nevada Test Site were estimated from flow logs and aquifer-test data. Borehole flow and drawdown were integrated and interpreted using a radial, axisymmetric flow model, AnalyzeHOLE. This integrated approach is used because complex well completions and heterogeneous aquifers and confining units produce vertical flow in the annular space and aquifers adjacent to the wellbore. AnalyzeHOLE simulates vertical flow, in addition to horizontal flow, which accounts for converging flow toward screen ends and diverging flow toward transmissive intervals. Simulated aquifers and confining units uniformly are subdivided by depth into intervals in which the hydraulic conductivity is estimated with the Parameter ESTimation (PEST) software. Between 50 and 150 hydraulic-conductivity parameters were estimated by minimizing weighted differences between simulated and measured flow and drawdown. Transmissivity estimates from single-well or multiple-well aquifer tests were used to constrain estimates of hydraulic conductivity. The distribution of hydraulic conductivity within each lithology had a minimum variance because estimates were constrained with Tikhonov regularization. AnalyzeHOLE simulated hydraulic-conductivity estimates for lithologic units across screened and cased intervals are as much as 100 times less than those estimated using proportional flow-log analyses applied across screened intervals only. Smaller estimates of hydraulic conductivity for individual lithologic units are simulated because sections of the unit behind cased intervals of the wellbore are not assumed to be impermeable, and therefore, can contribute flow to the wellbore. Simulated hydraulic-conductivity estimates vary by more than three orders of magnitude across a lithologic unit, indicating a high degree of heterogeneity in volcanic and carbonate-rock units. The higher water transmitting potential of carbonate-rock units relative to volcanic-rock units is exemplified by the large difference in their estimated maximum hydraulic conductivity; 4,000 and 400 feet per day, respectively. Simulated minimum estimates of hydraulic conductivity are inexact and represent the lower detection limit of the method. Minimum thicknesses of lithologic intervals also were defined for comparing AnalyzeHOLE results to hydraulic properties in regional ground-water flow models.
Rayleigh-step, helium purge, annular shaft seals, studied for use in liquid oxygen turbopumps, generate a hydrodynamic force that enables the seal to follow shaft perturbations. Hence, smaller clearances can be used to reduce seal leakage. FLOWCAL, a computer code developed by Mechanical Technology Incorporated, predicts gas flow rate through an annular seal with an axial pressure gradient. Analysis of a 50-mm Rayleigh-step, helium-purge, annular seal showed the flow rate increased axial pressure gradient, downstream pressure, and eccentricity ratio. Increased inlet temperature reduced leakage. Predictions made at maximum and minimum clearances (due to centrifugal and thermal growths, machining tolerances and + or - 2 percent uncertainty in the clearance measurement) placed wide boundaries on expected flow rates. The widest boundaries were set by thermal growth conditions. Predicted flow rates for a 50-mm Rayleigh-step, helium-purge, annular seal underestimated measured flow rates by three to seven times. However, the analysis did accurately predict flow rates for choked gas flow through annular seals when compared to flow rates measured in two other independent studies.
At the end & 1940 an investigation of a guide-vane lattice for the compressor of a TL unit [NACA comment: Turbojet] was requested. The greatest possible Mach number had to be attained. The investigation was conducted with an annular lattice subjected to axial flow. A direct-current shunt motor with a useful output of 235 horsepower at en engine speed of 1800 qm was available for driving the necessary blower. In designing the blower the speed was set at 10,000 rpm. A gear box fran an armored car was used as gearing in which supplementary fresh oil lubrication was installed. The gear box was used to step up from low to high speeds. The blower that was designed is two stage. The hub-tip ratios are 0.79 to 0.82; the design pressure coefficient for each stage is 0.6 and the design flow coefficient is 0.4. The rotor dosimeter D sub a is 0.39 meters and the resulting peripheral speed is u sub a = 204 meters per second [NACA comment: Value corrected from the German]. The blower was entirely satisfactory. The construction of the test stand is shown in figure 1. The air flows in through an annular Inlet, which is used in the measurement of the quantity of air, and is deflected into an inward-pointing radial slot. A spiral motion is imparted to the air by a guide-vane installation manually adjustable as desired, which enables injection of the air, after it has been deflected from the radial direction to the axial direction, into the lattice being investigated at any desired angle.
The recirculating flow field generated by a swirling jet and a coaxial annular stream entering a pipe is investigated with the use of 2D-DPIV. Parametric change of inlet flow rates (constant tangential injection with change of annular flow and vice versa) is being considered in order to study the mean and turbulent flow field. A recirculation bubble stabilized close to the swirler exit is the dominating feature of the interaction between the inner swirling jet and the annular stream. Results are discussed in terms of bubble topology and dynamics on the basis of a modified Rossby number that appears to describe the trends of the complex flow field. (author)
Test results are described for two abrupt area change annular diffusers with provisions for maintaining suction stabilized toroidal vortices at the area discontinuity. Both diffusers had an overall area ratio of 4.0 with the prediffuser area ratio being 1.18 for diffuser A and 1.4 for diffuser B. Performance was evaluated at near atmospheric pressure and temperature for a range of inlet Mach numbers from 0.18 to 0.41 and suction rates from 0 to 18%. Static pressure recovery improved significantly as the suction rate was increased to approximately 11%. Results obtained with diffuser A were superior to that obtained with diffuser B. Flat radial profiles of exit velocity were not obtained since the flow showed preferential hub or tip attachment at moderate suction rates. At high suction rates the diffuser exit flow became circumferentially nonuniform and unstable.
An experimental study was conducted in annular combustor model to provide a better understanding of the flowfield. Combustor model configurations consisting of primary jets only, annular jets only, and a combination of annular and primary jets were investigated. The purpose of this research was to provide a better understanding of combustor flows and to provide a data base for comparison with computational models. The first part of this research used a laser Doppler velocimeter to measure mean velocity and statistically calculate root-mean-square velocity in two coordinate directions. From this data, one Reynolds shear stress component and a two-dimensional turbulent kinetic energy term was determined. Major features of the flowfield included recirculating flow, primary and annular jet interaction, and high turbulence. The most pronounced result from this data was the effect the primary jets had on the flowfield. The primary jets were seen to reduce flow asymmetries, create larger recirculation zones, and higher turbulence levels. The second part of this research used a technique called marker nephelometry to provide mean concentration values in the combustor. Results showed the flow to be very turbulent and unsteady. All configurations investigated were highly sensitive to alignment of the primary and annular jets in the model and inlet conditions. Any imbalance between primary jets or misalignment of the annular jets caused severe flow asymmetries.