Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ALIGNMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 271 records · Page 15

Nonadiabatic alignment of van der Waals--force-bound argon dimers by femtosecond laser pulses

We demonstrated that the weak van der Waals-force-bound argon dimer can be nonadiabatically aligned by nonresonant femtosecond laser pulses, showing periodic alignment and anti-alignment revivals after the extinction of the laser pulse. Based on the measured nonadiabatic alignment trace, the rotational constant of the argon dimer ground state is determined to be B{sub 0}= 0.05756 {+-} 0.00004 cm{sup -1}. Noticeable alignment dependence of frustrated tunneling ionization and bond-softening induced dissociation of the argon dimer are observed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Effect of the annealing temperature and ion-beam bombardment on the properties of solution-derived HfYGaO films as liquid crystal alignment layers

Hafnium yttrium gallium oxide (HfYGaO) films were applied to liquid crystal displays (LCDs) as liquid crystal (LC) alignment layers, replacing conventional polyimide (PI) layers. The HfYGaO alignment layers were prepared by fabricating solution-processed HfYGaO films, annealing them, and treating them with ion-beam (IB) irradiation. The authors studied the effects of annealing temperature and IB irradiation of the solution-derived HfYGaO films on the orientation of LC molecules. The LC molecules on the solution-derived HfYGaO films were homogeneously and uniformly aligned by IB irradiation, irrespective of the annealing temperature. Atomic force microscopy analyses revealed that the surface reformation of the HfYGaO films induced by IB irradiation strengthened the van der Waals force between the LC molecules and the HfYGaO films, leading to uniform LC alignment. Enhanced electro-optical characteristics were observed in the twisted-nematic (TN) LCDs based on IB-irradiated HfYGaO films compared with those of TN-LCDs based on PI layers, demonstrating the high application potential of the proposed solution-derived HfYGaO films as LC alignment layers.

42 ENGINEERING↗

Effects On Beam Alignment Due To Neutron-Irradiated CCD Images At The National Ignition Facility

The 192 laser beams in the National Ignition Facility (NIF) are automatically aligned to the target-chamber center using images obtained through charged coupled device (CCD) cameras. Several of these cameras are in and around the target chamber during an experiment. Current experiments for the National Ignition Campaign are attempting to achieve nuclear fusion. Neutron yields from these high energy fusion shots expose the alignment cameras to neutron radiation. The present work explores modeling and predicting laser alignment performance degradation due to neutron radiation effects, and demonstrates techniques to mitigate performance degradation. Camera performance models have been created based on the measured camera noise from the cumulative single-shot fluence at the camera location. We have found that the effect of the neutron-generated noise for all shots to date have been well within the alignment tolerance of half a pixel, and image processing techniques can be utilized to reduce the effect even further on the beam alignment.

42 ENGINEERING↗

TU-D-209-03: Alignment of the Patient Graphic Model Using Fluoroscopic Images for Skin Dose Mapping

Purpose: The Dose Tracking System (DTS) was developed to provide realtime feedback of skin dose and dose rate during interventional fluoroscopic procedures. A color map on a 3D graphic of the patient represents the cumulative dose distribution on the skin. Automated image correlation algorithms are described which use the fluoroscopic procedure images to align and scale the patient graphic for more accurate dose mapping. Methods: Currently, the DTS employs manual patient graphic selection and alignment. To improve the accuracy of dose mapping and automate the software, various methods are explored to extract information about the beam location and patient morphology from the procedure images. To match patient anatomy with a reference projection image, preprocessing is first used, including edge enhancement, edge detection, and contour detection. Template matching algorithms from OpenCV are then employed to find the location of the beam. Once a match is found, the reference graphic is scaled and rotated to fit the patient, using image registration correlation functions in Matlab. The algorithm runs correlation functions for all points and maps all correlation confidences to a surface map. The highest point of correlation is used for alignment and scaling. The transformation data is saved for later model scaling. Results: Anatomic recognition is used to find matching features between model and image and image registration correlation provides for alignment and scaling at any rotation angle with less than onesecond runtime, and at noise levels in excess of 150% of those found in normal procedures. Conclusion: The algorithm provides the necessary scaling and alignment tools to improve the accuracy of dose distribution mapping on the patient graphic with the DTS. Partial support from NIH Grant R01-EB002873 and Toshiba Medical Systems Corp.

60 APPLIED LIFE SCIENCES↗

Stability Measurements for Alignment of the NIF Neutron Imaging System Pinhole Array

The alignment system for the National Ignition Facility's neutron imaging system has been commissioned and measurements of the relative stability of the 90-315 DIM, the front and the back of the neutron imaging pinhole array and an exploding pusher target have been made using the 90-135 and the 90-258 opposite port alignment systems. Additionally, a laser beam shot from the neutron-imaging Annex and reflected from a mirror at the back of the pinhole array was used to monitor the pointing of the pinhole. Over a twelve hour period, the relative stability of these parts was found to be within {approx} {+-}18 {micro}m rms even when using manual methods for tracking the position of the objects. For highly visible features, use of basic particle tracking techniques found that the front of the pinhole array was stable relative to the 90-135 opposite port alignment camera to within {+-}3.4 {micro}m rms. Reregistration, however, of the opposite port alignment systems themselves using the target alignment sensor was found to change the expected position of target chamber center by up to 194 {micro}m.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Segmented Ultralight Pre-Aligned Rotor for Extreme-Scale Wind Turbines

To alleviate the mass-scaling issues associated with conventional upwind rotors of extreme-scale turbines, a downwind rotor concept is proposed which employs fixed blade curvature based on force alignment at rated conditions. For a given peak stress constraint, the reduction in downwind cantilever loads allows reduced shell and spar thickness, and thus a reduced blade mass as compared with a conventional upwind rotor, especially as rotor sizes approach extreme-scales. To quantify this mass reduction, a Finite Element Analysis was conducted for a 10 MW rated rotor based on the NREL offshore 5 MW baseline wind turbine. The results show that this 'pre-alignment' yields a net downstream deflection of 32 deg, a downward hub-pitch angle of 6 deg, a 20% increase in blade length (to maintain the same radius as the conventional blade), and a net mass savings of about 50% through decreased shell and spar thicknesses. The pre-alignment may also allow a more straightforward and efficient segmentation of the blade since shear stresses near joints are substantially reduced. Segmenting, in turn, can dramatically reduce costs associated with fabrication, transport and assembly for extreme-scale off-shore systems. The pre-aligned geometric curvature can also help alleviate tower wake effects on the blades since blade tips (where shadow effects can be most problematic) are shifted downstream where the tower wake is weaker. In addition, the portion of the tower that is upstream of the blade tips can be faired with an externally-rotating aerodynamic shroud. Furthermore, the downwind rotor can allow a floating off-shore tri-pod platform to reduce tower weight and yaw-control requirements. A simple economic analysis of the segmented ultralight pre-aligned rotor (SUPAR) concept suggests that the overall system cost savings can be as much as 25%, indicating that more detailed (numerical and experimental) investigations are warranted.

17 WIND ENERGY↗

ARE TIDAL EFFECTS RESPONSIBLE FOR EXOPLANETARY SPIN–ORBIT ALIGNMENT?

The obliquities of planet-hosting stars are clues about the formation of planetary systems. Previous observations led to the hypothesis that for close-in giant planets, spin–orbit alignment is enforced by tidal interactions. Here, we examine two problems with this hypothesis. First, Mazeh and coworkers recently used a new technique—based on the amplitude of starspot-induced photometric variability—to conclude that spin–orbit alignment is common even for relatively long-period planets, which would not be expected if tides were responsible. We re-examine the data and find a statistically significant correlation between photometric variability and planetary orbital period that is qualitatively consistent with tidal interactions. However it is still difficult to explain quantitatively, as it would require tides to be effective for periods as long as tens of days. Second, Rogers and Lin argued against a particular theory for tidal re-alignment by showing that initially retrograde systems would fail to be re-aligned, in contradiction with the observed prevalence of prograde systems. We investigate a simple model that overcomes this problem by taking into account the dissipation of inertial waves and the equilibrium tide, as well as magnetic braking. We identify a region of parameter space where re-alignment can be achieved, but it only works for close-in giant planets, and requires some fine tuning. Thus, while we find both problems to be more nuanced than they first appeared, the tidal model still has serious shortcomings.

79 ASTRONOMY AND ASTROPHYSICS↗

Improving the performance of the actinic inspection tool with an optimized alignment procedure

Extreme ultraviolet (EUV) microscopy is an important tool for the investigation of the performance of EUV masks, for detecting the presence and the characteristics of defects, and for evaluating the effectiveness of defect repair techniques. Aerial image measurement bypasses the difficulties inherent to photoresist imaging and enables high data collection speed and flexibility. It provides reliable and quick feedback for the development of masks and lithography system modeling methods. We operate the SEMATECH Berkeley Actinic Inspection Tool (AIT), a EUV microscope installed at the Advanced Light Source at Lawrence Berkeley National Laboratory. The AIT is equipped with several high-magnification Fresnel zoneplate lenses, with various numerical aperture values, that enable it image the reflective mask surface with various resolution and magnification settings. Although the AIT has undergone significant recent improvements in terms of imaging resolution and illumination uniformity, there is still room for improvement. In the AIT, an off-axis zoneplate lens collects the light coming from the sample and an image of the sample is projected onto an EUV-sensitive CCD camera. The simplicity of the optical system is particularly helpful considering that the AIT alignment has to be performed every time that a sample or a zoneplate is replaced. The alignment is sensitive to several parameters such as the lens position and orientation, the illumination direction and the sample characteristics. Since the AIT works in high vacuum, there is no direct access to the optics or to the sample during the alignment and the measurements. For all these reasons the alignment procedures and feedback can be complex, and in some cases can reduce the overall data throughput of the system. In this paper we review the main strategies and procedures that have been developed for quick and reliable alignments, and we describe the performance improvements we have achieved, in terms of aberration magnitude reduction.

36 MATERIALS SCIENCE↗

LCLS Undulator Commissioning, Alignment, and Performance

The LCLS x-ray FEL has recently achieved its 1.5-Angstrom lasing and saturation goals upon first trial. This was achieved as a result of a thorough pre-beam checkout, both traditional and beam-based component alignment techniques, and high electron beam brightness. The x-ray FEL process demands very tight tolerances on the straightness of the electron beam trajectory (<5 {micro}m) through the LCLS undulator system. Tight, but less stringent tolerances of {approx}100 {micro}m rms were met for the transverse placement of the individual undulator segments with respect to the beam axis. The tolerances for electron beam straightness can only be met through a beam-based alignment (BBA) method, which is implemented using large electron energy variations and sub-micron resolution cavity beam position monitors (BPM), with precise conventional alignment used to set the starting conditions. Precision-fiducialization of components mounted on remotely adjustable girders, and special beam-finder wires (BFW) at each girder have been used to meet these challenging alignment tolerances. Longer-term girder movement due to ground motion and temperature changes are being monitored, continuously, by a unique stretched wire and hydrostatic level Alignment Diagnostics System (ADS).

43 PARTICLE ACCELERATORS↗

Alignment of the ALICE Inner Tracking System with Cosmic-Ray Tracks

ALICE (A Large Ion Collider Experiment) is the LHC (Large Hadron Collider) experiment devoted to investigating the strongly interacting matter created in nucleus-nucleus collisions at the LHC energies. The ALICE ITS, Inner Tracking System, consists of six cylindrical layers of silicon detectors with three different technologies; in the outward direction: two layers of pixel detectors, two layers each of drift, and strip detectors. The number of parameters to be determined in the spatial alignment of the 2198 sensor modules of the ITS is about 13,000. The target alignment precision is well below 10 {micro}m in some cases (pixels). The sources of alignment information include survey measurements, and the reconstructed tracks from cosmic rays and from proton-proton collisions. The main track-based alignment method uses the Millepede global approach. An iterative local method was developed and used as well. We present the results obtained for the ITS alignment using about 10{sup 5} charged tracks from cosmic rays that have been collected during summer 2008, with the ALICE solenoidal magnet switched off.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Enhancing Molecular Alignment and Charge Transport of Solution-Sheared Semiconducting Polymer Films by the Electrical-Blade Effect

Controlling polymer chain alignment through processing is a means of tuning the charge transport of solution-based conjugated polymers. In this work, a processing strategy is proposed in which an external electric field (E-field) is applied to the coating blade (E-blade) to align polymer chain during solution-shearing, a meniscus-guided coating technique. A theoretical model based on dielectrophoresis quantitatively describes and predicts the alignment process and is used to guide the selection of the optimal conditions of the applied E-field. Using these conditions, more than two-fold increase in chain alignment is observed for E-bladed thin films of a diketopyrrolopyrrole (DPP) semiconducting polymer without affecting other morphological aspects such as film thickness, film coverage or fiber-like aggregation. Organic field effect transistors based on the E-bladed DPP polymer are fabricated at ambient conditions and over areas of a few cm2. They display a 3-fold improvement in their mobilities and a strong enhancement in charge transport anisotropy compared to films prepared without E-field. These results reveal a synergistic alignment effect from both the solution-shearing process and the applied E-field, and introduce a novel and general approach to control the morphology and the electrical properties of solutioncoated conjugated polymer thin films.

42 ENGINEERING↗

Electric-Field-Induced Alignment of Block Copolymer/Nanoparticle Blends

External electric fi elds readily align birefringent block-copolymer mesophases. In this study the effect of gold nanoparticles on the electric-fi eld-induced alignment of a lamellae-forming polystyrene- block -poly(2-vinylpyridine) copolymer is assessed. Nanoparticles are homogeneously dispersed in the styrenic phase and promote the quantitative alignment of lamellar domains by substantially lowering the critical field strength above which alignment proceeds. The results suggest that the electric-fi eldassisted alignment of nanostructured block copolymer/nanoparticle composites may offer a simple way to greatly mitigate structural and orientational defects of such fi lms under benign experimental conditions.

Liedel, Clemens↗

Growth of Crystallographically Aligned PbSe Films of Controlled Thickness on Amorphous Substrates

Lead selenide (PbSe) has extensively been investigated due to its thermoelectric and photoconductive properties. More recently, predictions of emergent properties have focused synthetic efforts on preparing ultra-smooth layers of crystallographically aligned PbSe layers with a thickness equal to an integer number of monolayers. While rough films are typically formed through Volmer-Weber growth on heated substrates, we report the data presented herein indicates that a crystallographically aligned, ultrathin layer with a defined number of PbSe layers forms on mostly amorphous Mo-Se and V-Se coated Si substrates during nominally room temperature deposition. Since the films are uniform in thickness, the number of PbSe bilayers formed depends on the amount of Pb (or Se) deposited. If the amount of Pb deposited is close to that required for an integral number of unit cells and there is sufficient Se, Laue oscillations are present in the as-deposited samples. The Laue oscillations reflect the quality and uniformity of the crystalline PbSe domains. This study demonstrates that the substrate does not need to be crystalline to form uniform, crystallographically aligned, integer monolayer thick PbSe films. These results suggest that tuning the strength of interactions be-tween substrate and growing film is necessary to form smooth, crystallographically aligned layers. The substrate does not need to be crystalline for these interactions to be strong enough to enable growth of crystallographically aligned films.

36 MATERIALS SCIENCE↗

A natural mechanism for approximate Higgs alignment in the 2HDM

The 2HDM possesses a neutral scalar interaction eigenstate whose tree-level properties coincide with the Standard Model (SM) Higgs boson. In light of the LHC Higgs data which suggests that the observed Higgs boson is SM-like, it follows that the mixing of the SM Higgs interaction eigenstate with the other neutral scalar interaction eigenstates of the 2HDM should be suppressed, corresponding to the so-called Higgs alignment limit. The exact Higgs alignment limit can arise naturally due to a global symmetry of the scalar potential. If this symmetry is softly broken, then the Higgs alignment limit becomes approximate (although still potentially consistent with the current LHC Higgs data). In this paper, we obtain the approximate Higgs alignment suggested by the LHC Higgs data as a consequence of a softly broken global symmetry of the Higgs Lagrangian. However, this can only be accomplished if the Yukawa sector of the theory is extended. We propose an extended 2HDM with vector-like top quark partners, where explicit mass terms in the top sector provide the source of the soft symmetry breaking of a generalized CP symmetry. In this way, we can realize approximate Higgs alignment without a significant fine-tuning of the model parameters. We then explore the implications of the current LHC bounds on vector-like top quark partners for the success of our proposed scenario.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of High Magnetic Pulse Iteration on Electrical Property of CNT-Polypyrrole Composite: Alignment Mechanism

In this work, a pulsed magnetic field of 10 T with a duration of 1.5 ms is produced by a resistor-inductor-capacitor (RLC) discharge system. A carbon nanotube-polypyrrole (CNT-PPy) composite (9 wt%) is prepared. The influence of the pulsed magnetic field iteration on the alignment of CNTs embedded in polymer matrix is observed (up to 60 pulses). The microstructure of the magnetically aligned composites is probed by scanning probe microscopy technique. The behavior of a CNT in a magnetic field is theoretically studied, and the equivalent magnetic susceptibility for an anisotropic CNT is calculated. The theory of CNT alignment in a magnetic field is discussed. We found that the perpendicular diamagnetism of a CNT results in its alignment in a magnetic field. We showed that the magnetic torque, which is applied to a CNT, depends on the perpendicular and parallel susceptibilities of the CNT as well as on its initial orientation with respect to the magnetic direction. After exposure to magnetic pulses, the electrical property of the composites is enhanced. The results show that there is a positive correlation between the electrical conductance of CNTs and the number of applied pulses (for 30 pulses). Fourier transform infrared spectroscopy technique is used to control the polymer structure during the experiment. Our theoretical finding reveals the limited capacity of CNT’s alignment in magnetic fields.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Low-Field Alignment of Anisotropic Bonded Magnets for Additive Manufacturing of Permanent Magnet Motors

Additive manufacturing techniques for fabricating bonded magnets have the potential to reduce manufacturing cost and time-to-market of products and address the criticality of rare-earth elements (REEs), which is a concern for economic design of dependent applications such as permanent magnet machines. We investigated the magnetic alignment of anisotropic bonded magnet material comprising 65 vol.% Nd-Fe-B in nylon-12 produced by extrusion in a 20-W brushless direct current surface permanent magnet motor for submersible water pump application using finite element analysis. The results predict that sufficient alignment for this application could be obtained at low alignment fields (μoH ≤ 1 T) with a reduction in the volume of critical materials by up to 40% compared with isotropic permanent magnets. Furthermore, this demonstrates the economic feasibility of incorporating a magnetic alignment field source into additive manufacturing systems for bonded magnets, and the potential of aligned anisotropic bonded magnets to address REE criticality.

36 MATERIALS SCIENCE↗

3D microband boundary alignments and transitions in a cold rolled commercial purity aluminum alloy

In the study of microband formation during plastic deformation of face centered cubic metals and alloys, two theories have been proposed regarding the orientations of their boundaries: (i) they are aligned parallel to crystallographic planes associated with dislocation glide (i.e. (111) planes in FCC metals), or (ii) they are aligned in accordance with the macroscopic stress state generated during deformation. In this study, high resolution 3D electron backscatter diffraction (3D EBSD) was used to investigate the morphology and crystallographic nature of microband boundaries within a 19 × 9 × 8.6 μm volume of a deformed grain in commercial purity aluminum cold rolled to 22% reduction. It was found that microband boundaries correspond to both theories of orientation. Additionally, a single surface may contain both crystallographic and non-crystallographic alignments. Misorientations across boundaries in the regions of microband triple junctions have been identified for both boundary alignments. - Highlights: ► Reconstruction of a 3D volume of crystallographic orientations from EBSD data ► Subgrain features accurately reconstructed using specially designed strategies. ► Microband boundaries contain crystallographic and non-crystallographic alignments. ► Boundaries form by crystallographic process but rotate to non-crystallographic.

36 MATERIALS SCIENCE↗

First measurement of prompt and non-prompt D* + vector meson spin alignment in pp collisions at $\sqrt{s}$ = 13 TeV

This letter reports the first measurement of spin alignment, with respect to the helicity axis, for D* + vector mesons and their charge conjugates from charm-quark hadronisation (prompt) and from beauty meson decays (non-prompt) in hadron collisions. The measurements were performed at midrapidity (|y| < 0.8) as a function of transverse momentum (p T ) in proton–proton (pp) collisions collected by ALICE at the centre-of-mass energy $\sqrt{s}$ = 13 TeV. The diagonal spin density matrix element $ρ$00 of D* + mesons was measured from the angular distribution of the D* + → D 0 (→ K - π + )π + decay products, in the D* + rest frame, with respect to the D* + momentum direction in the pp centre of mass frame. The $ρ$00 value for prompt D* + mesons is consistent with 1/3, which implies no spin alignment. However, for non prompt D* + mesons an evidence of $ρ$00 larger than 1/3 is found. The measured value of the spin density element is $ρ$00 = 0.455±0.022(stat.)±0.035(syst.) in the 5 < p T < 20 GeV/c interval, which is consistent with a Pythia 8 Monte Carlo simulation coupled with the EvtGen package, which implements the helicity conservation in the decay of D* + meson from beauty mesons. In non-central heavy-ion collisions, the spin of the D* + mesons may be globally aligned with the direction of the initial angular momentum and magnetic field. Based on the results for pp collisions reported in this letter it is shown that alignment of non-prompt D* + mesons due to the helicity conservation coupled to the collective anisotropic expansion may mimic the signal of global spin alignment in heavy-ion collisions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗