Chemical and Electronic Structure at the Interface between a Sputter-Deposited Zn(O,S) Buffer and a Cu(In,Ga)(S,Se) 2 Solar Cell Absorber

The chemical and electronic structure of the interface between a sputter-deposited Zn(O,S) buffer layer and an industrial Cu(In,Ga)(S,Se) 2 (CIGSSe) absorber for thin-film solar cells is investigated with X-ray and UV photoelectron spectroscopy, inverse photoemission spectroscopy, and X-ray emission spectroscopy. We find a CIGSSe absorber surface band gap of 1.61 (±0.14) eV, which is significantly increased as compared to the minimal value derived with bulk-sensitive methods (≈1.1 eV). We find no indication for diffusion of absorber elements into the buffer layer. Surface- and bulk-sensitive measurements of the buffer layer suggest the presence of S-Zn and S-O bonds in the Zn(O,S) layer. We find that the naturally existing downward band bending toward the CIGSSe absorber surface is increased by the formation of the interface, likely enhancing carrier separation under illumination. We also derive a flat conduction band alignment, in line with the reported high conversion efficiencies of corresponding large-area solar cells.

14 SOLAR ENERGY↗

In Vivo Feasibility of Arterial Embolization with Permanent and Absorbable Suture: The FAIR-Embo Concept

Purpose: Arterial embolization has been shown to be effective and safe for the management of bleeding, especially for postpartum and pelvic traumatic bleeding. We propose to evaluate the proof of concept of feasibility and effectiveness of arterial embolization with absorbable and non-absorbable sutures in a porcine model. Materials and Methods: In the acute setting (n = 1), several different arteries (mesenteric, splenic, pharyngeal, kidney) were embolized using non-absorbable sutures (NAS): Mersutures™ braided sutures (polyethylene terephthalate). In the chronic setting (n = 3), only lower pole renal arteries were embolized. On the right side, NAS was used, whereas on the left side embolization was realized with absorbable suture (AS): Vicryl{sup ®} braided suture (polyglactin 910). The chronic group was followed for 3 months. The pigs received contrast-enhanced CT the day before embolization (D-1), after the embolization (D0), at 1 month and 3 months after embolization (M1 and M3); digital subtraction angiography (DSA) was done at D0 and M3 and histological analysis at M3. Results: All vascular targets were effectively embolized without any pre- or postoperative complications. Both DSAs and CTs at M3 showed a 100% recanalization rate for the AS embolization and a partial reversal rate for the NAS embolization. A renal hypotrophy in the embolized region was observed during both the M1 and M3 scans for both sutures (AS and NAS) with a clear hypotrophy for the NAS embolized kidney. Conclusion: Embolization by AS and NAS (FAIR-Embo) is a feasible and effective treatment which opens up the possibility of global use of this inexpensive and widely available embolization agent.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimal absorber thickness in long-wave multiple-stage detector

The detectivity characteristics of interband cascade infrared type-II superlattice detectors for long-wave infrared detection (λ{sub cut-off} = 8 μm at room temperature) are discussed. We present comparison of two superlattices: InAs/GaSb and InAs/InAsSb, assuming the characteristic parameters—absorption coefficients α and carrier lifetimes τ published in literature. Dependence of the Johnson-noise limited detectivity on the absorber thickness for a different number of stages is reported. Higher detectivity D{sup *} value can be achieved by increasing the carrier lifetime. However, for detectors based on type-II InAs/GaSb superlattice increasing the carrier lifetime up to 25 ns leads to a situation in which one stage is preferred, i.e. for detector with a single absorber, we obtain the highest detectivity value. In the case of InAs/InAsSb material, the situation is similar for τ ≥ 80 ns. We have shown that the optimal absorber thickness at which the highest detectivity values are obtained depends not only on the absorption coefficient α and the number of stages N{sub S}, but also on the carrier diffusion length L. According to a calculations, cascade detectors based on Ga-free material should have much higher optimal absorber thicknesses than materials based on InAs/GaSb.

42 ENGINEERING↗

Moving beyond the limits of mass transport in liquid absorbent microfilms through the implementation of surface-induced vortices

The slow diffusion of an absorbate molecule into an absorbent often makes the absorption process a rate-limiting step in many applications. In cases involving an absorbate with a high heat of phase change, such as water absorption into a LiBr (lithium bromide) solution, the absorption rate is further slowed due to significant heating of the absorbent. Recently, it has been demonstrated that constraining a LiBr solution film by a hydrophobic porous structure enables manipulation of the solution flow thermohydraulic characteristics. Here, it is shown that mass transport mode in a constrained laminar solution flow can be changed from diffusive to advective. This change in mode is accomplished through stretching and folding the laminar streamlines within the solution film via the implementation of micro-scale features on the flow channel surface. The process induces vortices within the solution film, which continuously bring concentrated solution from the bottom and middle of the solution channel to its interface with the vapor phase, thus leading to a significant enhancement in the absorption rate. The detailed physics of the involved transport processes is elucidated using the LBM (Lattice Boltzmann Method). Published by Elsevier Ltd.

Bigham, S↗

Pain and Mean Absorbed Dose to the Pubic Bone After Radiotherapy Among Gynecological Cancer Survivors

Purpose: To analyze the relationship between mean absorbed dose to the pubic bone after pelvic radiotherapy for gynecological cancer and occurrence of pubic bone pain among long-term survivors. Methods and Materials: In an unselected, population-based study, we identified 823 long-term gynecological cancer survivors treated with pelvic radiotherapy during 1991-2003. For comparison, we used a non-radiation-treated control population of 478 matched women from the Swedish Population Register. Pain, intensity of pain, and functional impairment due to pain in the pubic bone were assessed with a study-specific postal questionnaire. Results: We analyzed data from 650 survivors (participation rate 79%) with median follow-up of 6.3 years (range, 2.3-15.0 years) along with 344 control women (participation rate, 72 %). Ten percent of the survivors were treated with radiotherapy; ninety percent with surgery plus radiotherapy. Brachytherapy was added in 81%. Complete treatment records were recovered for 538/650 survivors, with dose distribution data including dose-volume histograms over the pubic bone. Pubic bone pain was reported by 73 survivors (11%); 59/517 (11%) had been exposed to mean absorbed external beam doses <52.5 Gy to the pubic bone and 5/12 (42%) to mean absorbed external beam doses {>=}52.5 Gy. Thirty-three survivors reported pain affecting sleep, a 13-fold increased prevalence compared with control women. Forty-nine survivors reported functional impairment measured as pain walking indoors, a 10-fold increased prevalence. Conclusions: Mean absorbed external beam dose above 52.5 Gy to the pubic bone increases the occurrence of pain in the pubic bone and may affect daily life of long-term survivors treated with radiotherapy for gynecological cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Preparation and characterization of microwave absorbing composite materials with GSs or FeCo/GS composites

Highlights: • It is found that adding GSs or FeCo/GSs composite into the sample SiC/NR can greatly increase RL and the absorbing peak shifts to low-frequency with increasing the adding amount. • The optimum adding amount of GSs is 2%. The sample GS-200-2% possesses the lowest RL value of −31.27 dB at 7.6 GHz. • The optimum adding amount of FeCo/GSs composite is 3%. The sample AGS-450-3% possesses the lowest RL value of −20.67 dB at 7.8 GHz. - Abstract: This study mainly explored the synthesis method of graphene sheets (GSs) and FeCo/graphene sheet (FeCo/GS) composites and evaluated the microwave absorbing characteristics of composite materials containing GSs or FeCo/GS composites. First, graphite oxide (GO) was synthesized by the modified Hummers method. The synthesized GO was further used to synthesize GSs and FeCo/GS composites. Afterward, GSs or FeCo/GS composites were mixed with silicon carbide (SiC) and natural rubber (NR) to prepare microwave absorbing materials with thicknesses of 2 mm. Finally, identification and characterization of these samples were performed by XRD, FE-SEM, TEM, TGA, ESCA, RS, AFM and VNA. GSs were synthesized successfully at a low annealing temperature of 200 °C, and their thicknesses were between 0.848 nm and 2.115 nm, which corresponds to 2–6 stacked layers of graphene. FeCo/GS composites were also synthesized successfully at three different annealing temperatures. The nanoparticles of metals and metal oxides were well-dispersed on the surfaces of and the spaces between GSs. It was found that adding GSs or FeCo/GS composites into the SiC/NR sample can greatly increase reflection loss (RL) and that the absorbing peak shifts to lower frequencies as the concentration of added particles increases. The optimum concentration of added GSs was 2 wt.%. The GS-200-2% sample possessed the lowest RL value of −31.27 dB at 7.6 GHz. The optimum concentration of added FeCo/GS composites was 3 wt.%. The AGS-450-3% sample possessed the lowest RL value of −20.67 dB at 7.8 GHz.

36 MATERIALS SCIENCE↗

Multicolored microwave absorbers with dynamic frequency modulation

Microwave-absorbing materials are extensively used in intelligent electronic devices and stealth technologies where the ability to dynamically adjust microwave-absorbing capacity in response to specific requirements is vitally important. Herein, we report a new approach for constructing dynamically tunable microwave absorbers with ultrawide tunable frequency ranges that are simultaneously endowed with vibrant structural colors. Here, the methodology produces structural colors and adjusts absorption properties by constructing ZnO coatings with precisely adjustable thicknesses on a polypyrrole/melamine foam (PPy/MF) surface by atomic layer deposition (ALD) in conjunction with a pressure-driven strategy that regulates the compression ratio. The electrical conductivity, electromagnetic parameters, thickness, and pore size of the ZnO-coated PPy/MF (ZnO/PPy/MF) are effectively adjusted, and simply applying external pressure widens the tunable frequency range and the effective absorption bandwidth. As a result, the effective absorption frequency of ZnO/PPy/MF is dynamically adjustable from the S band to the Ku band, thereby covering 94.3% of the entire microwave spectrum. Moreover, the brilliant and uniform structural colors of ZnO/PPy/MF, which span various color categories, are precisely regulated by tuning the thickness of the ZnO coating by adjusting the number of ALD cycles. ZnO/PPy/MF is strongly hydrophobic, which endows it with remarkable self-cleaning properties. Therefore, ZnO/PPy/MF provides a conceptually novel platform for the development of next-generation smart microwave-absorbing materials due to its integrated dynamic frequency-regulating ability, brilliant structural coloration, and self-cleaning features.

36 MATERIALS SCIENCE↗

Absorber Clamp for Microcalorimeter Decay Energy Spectrometry

Microcalorimeter Decay Energy Spectrometry (DES) is of interest to nuclear safeguards due to its ability to provide high precision isotopic compositions of nanogram-to microgram-scale samples of Pu and U and related daughter products. The DES method is able to record decay energy of each alpha-decay event in a sample that is embedded in a metal matrix (absorber) and thermally linked to a microcalorimeter detector. This work optimizes the DES technique used to thermally link the absorber and microcalorimeter detector element to allow for more rapid assembly and to increase detector performance and operating life. Optimized attachment methods are crucial for enhancing the viability of DES in high-sample-throughput facilities, such as those that support international nuclear safeguards measurements. Here, in this study, we designed and implemented a pressure-based absorber clamp and evaluated the performance of this new attachment method relative to pressed indium bond attachment. Results using the absorber clamp demonstrate a streamlined detector assembly procedure that minimizes accidental damage to detectors, as well as increasing detector pulse speeds by 57%. Spectral comparison shows the clamp preserves detector performance relative to indium attachment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mid-infrared chiral metasurface absorbers with split-ellipse structures

Natural chiral materials usually have very weak circular dichroism (CD) responses. Here, in this study, we design and demonstrate one type of mid-infrared chiral metasurface absorber with strong chiroptical effects, which can achieve high CD in absorption above 0.57 over the wavelength range of 5 to 5.9 μm. The maximum absorption of the chiral metasurface absorber under circularly polarized light can reach 0.90 and the maximum CD in absorption is 0.63. Meanwhile, the chiral resonance wavelength and the CD value can be tuned by varying the geometric parameters of the metasurface. A thermal analysis of the metasurface absorber further shows the strong connection between CD in absorption and temperature difference. The demonstrated chiral metasurface absorbers can be used in many promising applications such as molecular sensing, thermophotovoltaics and chiral spectroscopy.

36 MATERIALS SCIENCE↗

3D Printed Absorber for Capturing Chemotherapy Drugs before They Spread through the Body

Despite efforts to develop increasingly targeted and personalized cancer therapeutics, dosing of drugs in cancer chemotherapy is limited by systemic toxic side effects. We have designed, built, and deployed porous absorbers for capturing chemotherapy drugs from the bloodstream after these drugs have had their effect on a tumor, but before they are released into the body where they can cause hazardous side effects. The support structure of the absorbers was built using 3D printing technology. This structure was coated with a nanostructured block copolymer with outer blocks that anchor the polymer chains to the 3D printed support structure and a middle block that has an affinity for the drug. The middle block is polystyrenesulfonate which binds to doxorubicin, a widely used and effective chemotherapy drug with significant toxic side effects. The absorbers are designed for deployment during chemotherapy using minimally invasive image-guided endovascular surgical procedures. We show that the introduction of the absorbers into the blood of swine models enables the capture of 64 ± 6% of the administered drug (doxorubicin) without any immediate adverse effects. Problems related to blood clots, vein wall dissection, and other biocompatibility issues were not observed. This development represents a significant step forward in minimizing toxic side effects of chemotherapy.

59 BASIC BIOLOGICAL SCIENCES↗

Ultrafast Charge Transfer between Light Absorber and Co 3 O 4 Water Oxidation Catalyst across Molecular Wires Embedded in Silica Membrane

Here, the mechanism of visible light-induced hole transfer from a molecular light absorber, in the form of a free-base porphyrin, coupled to a Co 3 O 4 nanoparticle catalyst for water oxidation by a molecular wire (p-oligo(phenylenevinylene) featuring three aryl units) is investigated by transient absorption spectroscopy. The wires are covalently anchored on the Co 3 O 4 surface and embedded in a dense, yet ultrathin (2 nm), silica layer that separates light absorber and catalyst. The porphyrin is electrostatically adsorbed on the silica surface, and aqueous colloidal solutions of the core–shell particles are used for transient optical measurements. Pulsed optical excitation of the porphyrin results in rapid injection of the photogenerated hole onto the molecular wire and concurrent formation of reduced light absorber in less than 1 picosecond (ps). Ultrafast charge separation was monitored by transient absorption of the wire radical cation, which is given by bands in the 500 to 600 nm region and at 1130 nm, while formation of reduced porphyrin was characterized by absorption at 700 nm. Forward transfer of the hole to Co 3 O 4 catalyst proceeds in 255 ± 23 ps. Ultrafast transfer of positive charge from the molecular assembly to a metal oxide nanoparticle catalyst for water oxidation is unprecedented. Holes on Co 3 O 4 recombined with electrons of the reduced sensitizer with biphasic kinetics on a much longer time scale of ten to several hundred nanoseconds. Finally, the unusually efficient hole transfer coupling of a molecular light absorber with an Earth-abundant metal oxide catalyst by silica-embedded p-oligo(phenylenevinylene) offers an approach for integrated artificial photosystems featuring product separation on the nanoscale.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Superlative mechanical energy absorbing efficiency discovered through self-driving lab-human partnership

Energy absorbing efficiency is a key determinant of a structure’s ability to provide mechanical protection and is defined by the amount of energy that can be absorbed prior to stresses increasing to a level that damages the system to be protected. Here, we explore the energy absorbing efficiency of additively manufactured polymer structures by using a self-driving lab (SDL) to perform >25,000 physical experiments on generalized cylindrical shells. We use a human-SDL collaborative approach where experiments are selected from over trillions of candidates in an 11-dimensional parameter space using Bayesian optimization and then automatically performed while the human team monitors progress to periodically modify aspects of the system. The result of this human-SDL campaign is the discovery of a structure with a 75.2% energy absorbing efficiency and a library of experimental data that reveals transferable principles for designing tough structures.

42 ENGINEERING↗

Spiers Memorial Lecture: Next generation chalcogenide-based absorbers for thin-film solar cells

Inorganic-based thin-film photovoltaics (TFPV) represents an important component of the growing low-carbon energy market and plays a vital role in the drive toward lower cost and increased penetration of solar energy. Yet, commercialized thin-film absorber technologies suffer from some non-ideal characteristics, such as toxic or non-abundant element use (e.g., CdTe and Cu(In,Ga)(S,Se) 2 , which bring into question their suitability for terawatt deployment. Numerous promising chalcogenide, halide, pnictide and oxide semiconductors are being pursued to bridge these concerns for TFPV and several promising paths have emerged, both as prospective replacements for the entrenched technologies, and to serve as partner (i.e., higher bandgap) absorbers for tandem junction devices—e.g., to be used with a lower bandgap Si bottom cell. The current perspective will primarily focus on emerging chalcogenide-based technologies and provide both an overview of absorber candidates that have been of recent interest and a deeper dive into an exemplary Cu 2 BaSnS 4 -related family. Altogether, considering the combined needs of high-performance, low-cost, and operational stability, as well as the experiences gained from existing commercialized thin-film absorber technologies, chalcogenide-based semiconductors represent a promising direction for future PV development and also serve to highlight common themes and needs among the broader TFPV materials family.

14 SOLAR ENERGY↗

Experimental evidence of an incomplete thermalization of the energy in an x-ray microcalorimeter with a Ta/Au absorber

We have conducted an experimental test at our XACT facility using an x-ray microcalorimeter with Ta/Au absorber and neutron transmutation doped germanium thermal sensor. The test was aimed at measuring the percentage of energy effectively thermalized after absorption of x-ray photons in superconducting tantalum. Moreover, in general, possible formation of long living quasiparticles implies that by using a superconducting absorber, a fraction of the deposited energy could not be thermalized on the useful time scale of the thermal sensor. To investigate this scenario, we exploited an absorber made of gold, where no energy trapping is expected, with a small piece of superconducting tantalum attached on top. We obtained evidence that the thermalization of photons absorbed in tantalum is delayed by energy trapping from quasiparticles. We compare the experimental results with numerical simulations and derive a value for the intrinsic lifetime of quasiparticles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of the Body Distribution of Absorbed Dose in the Organs of Three Species of Fish from Sepetiba Bay

The body distribution of Polonium-210 in three fishes from the Sepetiba Bay (Macrodon ancylodon, Micropogonias furnieri and Mugil curema) has been studied under the approach of the Department of Energy of the United States of America (DOE) that set the limit of absorbed dose rate in biota equal to 3.5x10{sup 3} {mu}Gy/y, and that also established the relation between dose rate (D) and radionuclide concentration (c) on a fish muscle fresh weight basis, as follows: D = 5.05 ExNxC, assuming that the radionuclide distribution is homogenous among organs. Two hypotheses were tested here, using statistical tools: 1) is the body distribution of absorbed dose homogenous among organs? and 2) is the body distribution of absorbed dose identical among studied fishes? It was concluded, as expected, that the distribution among organs is heterogeneous; but, unexpectedly, that the three fishes display identical body distribution pattern, although they belong to different trophic levels. Hence, concerning absorbed dose calculation, the statement that data distribution is homogenous must be understood merely as an approximation, at least in the case of Polonium-210.

54 ENVIRONMENTAL SCIENCES↗

Portable UV-visible spectrometer for measuring absorbance and dichroism of Langmuir monolayers at air-water interfaces.

An UV-visible spectrometer for measuring absorbance and dichroism of Langmuir monolayers under in situ conditions is described. The spectrometer utilizes a stand-alone multipass sensor, which is placed in a Langmuir trough and coupled with light source and spectrometer head via fiber optics. Implementation of the multipass scheme in the absorbance sensor makes it possible to obtain reliable quantitative spectroscopic data of the Langmuir monolayers with absorbance as low as 1 mOD. Such high sensitivity makes the developed sensor very useful for UV-visible spectral studies of a wide variety of chromophores. The new technique was applied to several model systems: fatty acid monolayers containing amphiphilic dyes DiI or BODIPY and also a monolayer of a synthetic amphiphilic porphyrin-binding peptide BBC16. Implementation of UV-visible absorbance spectroscopy measurements in situ together with x-ray scattering technique was used to confirm the bound state of the chromophore, and determine the exact position of the latter in the peptide matrix. Fiber optics design of the spectrometer provides portability and compatibility with other experimental techniques making it possible to study samples with a geometry unsuitable for conventional spectroscopic measurements and located in experimental environments with spatial limitations, such as synchrotron x-ray scattering stations.

36 MATERIALS SCIENCE↗

Scanning hard x-ray differential phase contrast imaging with a double wedge absorber

Two-directional differential phase contrast images were measured using an x-ray microbeam and a double wedge absorber. The wedge absorber converts the displacement of an x-ray beam that is refracted by an object into change of x-ray intensity. The double wedge absorber made it possible to detect values of two-directional refraction angle with {mu}rad sensitivity simultaneously. By Fourier integration of two-directional phase gradients calculated from the refraction angle instead of line integration of one-directional phase gradients, we obtained a quantitative phase map without artifacts even when only a part of the boundaries of the object were in the field of view. One of the characteristics of this technique is flexibility in a sensitivity of the phase gradient. By changing of shape or material of the wedge absorber, it is comparatively easy to control the detection limit of the refraction angle.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A super-compact metamaterial absorber cell in L-band

A super-compact metamaterial absorber (SMA) unit cell in L band (1–2 GHz) is proposed, which is composed of a pair of electric ring resonator (ERR) and its complementary ERR (CERR) with a high dielectric substrate sandwiched in between. The CERR has a cross sectional area where approximately the etched copper foil in ERR is now retained, and the remaining region is now etched. In contract with quarter-wavelength (λ/4) thickness which is required for conventional absorbers, the largest in-plane dimension and thickness of the SMA cell are only λ/33 and λ/250, respectively, leading to a super compact cell volume. While traditionally the long straight wire is introduced in electric-LC resonators for increasing inductance, the CERR achieves similar inductance with much shorter lengths. Thus, its cell dimensions can be drastically reduced without compromising its performance. In addition, simulations together with an automated phase correction algorithm show that the SMA is a type of metamaterial possessing simultaneous negative electric permittivity (NEP) and negative magnetic permeability (NMP). Further the SMA has a very large imaginary part of the NEP and NMP, resulting in significantly large imaginary part of the refractive index at resonant frequency. These properties are well suited to design excellent absorbers. In addition, numerical results demonstrate that the maximum absorption coefficient of the SMA can reach greater than 99% at resonant frequency, and the full-width half-maximum is roughly 1% of the operating frequency, and a wide incident angle of ±49° over 90% absorption. Meanwhile, it is pointed out that this type of absorber is rather sensitive to polarization characteristic of the incident electromagnetic wave.

36 MATERIALS SCIENCE↗