Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “wind energy generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Cryogenic aspects of a 20 MW class low-temperature superconducting generator for the renewables industry

In this paper we give a progress update on the cryogenic design for cooling a 20 MW class, partially superconducting generator with stationary field coils for offshore wind renewables industry [1-2]. This is a continuation of an earlier program on a 10 MW system dating back ten years. Whereas this new power rating increase leads to a radial diameter expansion of the superconducting field coils from 4 to > 9.5 m, it maintains the axial length. We show the design based on this scaled up with enlarged diameter. The field coil size increase asks for higher cooling power that leads to a bigger cold box size to accommodate the cryocoolers. In the design, as many as 8 cryocoolers can be accessed and serviced from the nacelle that houses the main cryogenic components. A typical thermal load balance sheet with all components is given and compared against the available cryocooler cooling power at different operating conditions. Due to the cryocoolers’ local point of contact cooling within the nacelle, the temperature gradient of the thermal shield that fully encloses the cold mass with its embedded field coils needs to be balanced out to minimize the heat burden on the field coils. This requires additional analytical efforts and implementation of further design features. The extended nacelle houses the cold box with its cryogenic infrastructure. The interface for the envisaged cryogenic pushbutton closed-loop circulating system remains invisible, requires no handling of cryogenic liquids and is hermetically closed. The field coil diameter increase also leads to a greater initial helium gas storage volume. In addition, it requires higher initial room temperature fill pressure within the toroidal helium vapor storage tanks and in cooling tubes connecting to the cryocoolers. The toroidal helium gas tanks are thermally coupled with the thermal shield so that helium convection inside the storage tank can improve heat transfer and reduce the temperature gradient of the thermal shield. Besides those heat transfer challenges, additional mechanical strain within this large structure is exerted on the torque tubes during initial cooldown and when energizing field coils. Some of those design challenges are quite unexpected, leading to novel workarounds in order to maintain the chosen cooling strategy. Finally, we assess those design limitations in view of further cryogenic scalability with emphasis on manufacturability and assembly.

cryogenics↗

Repurposing Offshore Oil and Gas Platforms to Support Wind Power Generation

B. Gibbs, J. McAvoy, S. T. Nutakki and R. Seetharam, "Repurposing Offshore Oil and Gas Platforms to Support Wind Power Generation," 2025 IEEE International Communications Energy Conference (INTELEC), Houstin, TX, USA, 2025, pp. 215-221, doi: 10.1109/INTELEC63987.2025.11214768.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Synchronous Wind: Evaluating the Grid Impact of Inverterless Grid-Forming Wind Power Plants

Grid-forming (GFM) control of Type-3 and Type-4 wind turbine generators has attracted substantial attention in power systems research; however, the limited over-current capability of power electronics converters continues to deteriorate the grid strength of the evolving power systems. This paper develops the generic model of synchronous wind power generators, also known as Type-5 wind turbines, for power system integration studies. The Type-5 wind turbine interfaces with the electric grid through a synchronous generator; hence, its operation and consequent grid impacts are similar to a conventional power plant. Based on the developed model, a Type-5 wind power plant is integrated into the IEEE 14-bus test bed to evaluate its control and operation with a bulk power system. Finally, the stability properties of Type-5 wind turbine generators are compared with Type-3 wind turbines in GFM control mode through impedance characterization.

grid strength↗

Blackstart Capability and Survivability of Wind Turbines with Fully Rated Converters

We report the blackstart capability of wind turbines is critical for the recovery of wind-dominant power systems from blackouts. If wind power plants are not able to restore a power system, the incorporation of wind resources into electric grids could be limited by blackstart capability. This paper tackles this problem by setting forth a grid-forming controller for Type 4 wind turbines which employ fully rated power converters. To this end, we engineer two-axis anti-windup proportional-integral regulators that serve to ride through restoration disturbances. We also design an active protection system to prevent wind turbines from stalling during recovery from blackouts. We demonstrate in a high-fidelity simulation environment that Type 4 wind turbines with the developed controllers and protection subsystem can: (i) re-energize a notional wind-dominant grid; (ii) ride through asymmetrical faults; and (iii) survive low wind speed events.

17 WIND ENERGY↗

Design study of wind turbines 50 kW to 3000 kW for electric utility applications. Volume 3: Supplementary design and analysis tasks

Additional design and analysis data are provided to supplement the results of the two parallel design study efforts. The key results of the three supplemental tasks investigated are: (1) The velocity duration profile has a significant effect in determining the optimum wind turbine design parameters and the energy generation cost. (2) Modest increases in capacity factor can be achieved with small increases in energy generation costs and capital costs. (3) Reinforced concrete towers that are esthetically attractive can be designed and built at a cost comparable to those for steel truss towers. The approach used, method of analysis, assumptions made, design requirements, and the results for each task are discussed in detail.

Source record↗

Synchronous Wind: Evaluating the Grid Impact of Inverterless Grid-Forming Wind Power Plants: Preprint

Grid-forming (GFM) control of Type-3 and Type-4 wind turbine generators have attracted substantial attention in power system research. However, the limited over-current capability of power electronics converters continues to deteriorate the grid strength of the evolving power systems. This paper developed the generic model of synchronous wind power generators, also known as Type-5 wind turbines, for the power system integration studies. The Type-5 wind turbine interface to the grid through a synchronous generator; hence, its operation and consequent grid impacts are similar to a conventional power plant. Based on the developed model, a Type-5 wind power plant is integrated into IEEE 14-bus testbed to evaluate its control and operation with a bulk power system. Finally, the stability properties of Type-5 wind turbine generators are compared with Type-3 wind turbines in GFM control mode through impedance characterization.

grid strength↗

Island Power Systems With High Levels of Inverter-Based Resources: Stability and Reliability Challenges

As many island power systems seek to integrate high levels of renewable energy, they face new challenges on top of the existing difficulties of operating an isolated grid. With their drastically declining cost, variable renewables, such as wind and photovoltaics (PVs), are increasingly being integrated into island grids to reduce the use of imported fuels. These deployments of renewable energy are dominated by PV and wind generators, which bring unique challenges of their own.

IBRs↗

Prototyping of a Rotary Triboelectric Nanogenerator for Power at Sea

Increasing at-sea power generation by Triboelectric Nanogenerator (TENG) energy harvesters towards the order of 1-Watt will create significant opportunities to power ocean observation buoys and distributed sensor nodes by extending mission time and increasing sensor payload. Of the many possible configurations of harvesting wave energy with TENGs, we document the rationale for choosing and developing a rotary TENG that operates by the freestanding mode. The rotary TENG prototype consists of two plates, a rotor and a stator, to take advantage of the various mechanisms of converting wave action into rotational motion. We have constructed a testing apparatus that allows us to vary several key parameters of the device: distance between rotor and stator, triboelectric material, rotational speed, number of electrodes and output load impedance. Preliminary results show that when driven at a constant 500 rpm, we can achieve a power density of 0.7 W/m3. A variable speed motor drives the rotor, which can be driven using a velocity profile informed by the equivalent to the output from a wave energy converter (WEC). The optimized rotational TENG can be stacked and driven by a single shaft, increasing the energy density of the device. The output of such a TENG could be used to power devices in the ocean at a low cost and high durability.

electrostatic generator↗

Probabilistic Zonal Reserve Requirements for Improved Energy Deliverability with Wind Power

In power systems with high penetration of renewable energy resources, uncertainty and variability of these stochastic resources introduce additional challenges for the operation of power systems. To improve the power system's reliability in the face of uncertainty, reserves are required as additional generation capacity to rebalance the power system following random disturbances. However, reserve deliverability is not guaranteed, because it may encounter potential transmission line congestion. Zonal reserve requirements can address this issue, but operators lack efficient ways to allocate reserves to zones while accounting for wind power forecast uncertainty. Herein we propose a methodology for probabilistic zonal reserve requirements to address wind power forecast uncertainties. This method estimates the probability distribution of line flows based on the system generation margin and injection shift factor. This estimate is then used to construct pre-defined and post-zonal reserve requirements. Case studies demonstrate that the proposed method efficiently schedules energy and reserves to balance energy and manage deliverability with wind power forecast uncertainty.We also discuss operational implications of the proposed method.

17 WIND ENERGY↗

A simple method for modelling fatigue spectra of small wind turbine blades

Small-scale wind turbines have market opportunities in distributed energy generation applications but face future challenges in remaining cost competitive compared with solar photovoltaic systems. High unit costs can be attributed to design conservatism when calculating fatigue loads of key structural components such as the blades. In this study, we use the aeroelastic software FAST to highlight limitations of the International Electrotechnical Commission 61400-2:2013 small wind turbine design standard for calculating fatigue life using the simplified load model. We present a modified method for calculating the fatigue spectra of small wind turbine blades. An advantage of this method is that it does not require complex aeroelastic simulations or field measurements. This modified method is intended to be implemented early in the blade design stage, such as during rotor optimization simulations, allowing for multiple rotor configurations to be rapidly compared.

17 WIND ENERGY↗

Projecting Future Energy Production from Operating Wind Farms in North America. Part I: Dynamical Downscaling

Abstract New simulations at 12-km grid spacing with the Weather and Research Forecasting (WRF) Model nested in the MPI Earth System Model (ESM) are used to quantify possible changes in wind power generation potential as a result of global warming. Annual capacity factors (CF; measures of electrical power production) computed by applying a power curve to hourly wind speeds at wind turbine hub height from this simulation are also used to illustrate the pitfalls in seeking to infer changes in wind power generation directly from low-spatial-resolution and time-averaged ESM output. WRF-derived CF are evaluated using observed daily CF from operating wind farms. The spatial correlation coefficient between modeled and observed mean CF is 0.65, and the root-mean-square error is 5.4 percentage points. Output from the MPI-WRF Model chain also captures some of the seasonal variability and the probability distribution of daily CF at operating wind farms. Projections of mean annual CF (CF A ) indicate no change to 2050 in the southern Great Plains and Northeast. Interannual variability of CF A increases in the Midwest, and CF A declines by up to 2 percentage points in the northern Great Plains. The probability of wind droughts (extended periods with anomalously low production) and wind bonus periods (high production) remains unchanged over most of the eastern United States. The probability of wind bonus periods exhibits some evidence of higher values over the Midwest in the 2040s, whereas the converse is true over the northern Great Plains. Significance Statement Wind energy is playing an increasingly important role in low-carbon-emission electricity generation. It is a “weather dependent” renewable energy source, and thus changes in the global atmosphere may cause changes in regional wind power production (PP) potential. We use PP data from operating wind farms to demonstrate that regional simulations exhibit skill in capturing actual power production. Projections to the middle of this century indicate that over most of North America east of the Rocky Mountains annual expected PP is largely unchanged, as is the probability of extended periods of anomalously high or low production. Any small declines in annual PP are of much smaller magnitude than changes due to technological innovation over the last two decades.

Meteorology & Atmospheric Sciences↗

Renewable Energy Materials Properties Database: Summary

Renewable energy is providing a growing share of electricity generation in the United States, with generation from utility scale wind and solar increasing by 12% and 29%, respectively, in 2020 (EIA 2021). Installation of new renewable energy facilities requires material inputs that range from common construction materials to specialized, high-performance materials that may have limited availability. This report summarizes the Department of Energy (DOE) Wind Energy Technologies Office (WETO) and DOE Solar Energy Technologies Office (SETO) database of materials used in domestic wind and solar installations. The Energy Act of 2020 directs WETO and SETO to deliver a "comprehensive physical property database of materials for use in [wind and solar] energy technologies, which shall identify the type, quantity, country of origin, source, significant uses, projected availability, and physical properties of materials used in [wind and solar] energy technologies" by no later than September 1, 2022. This report is the summary and directions for use of the Renewable Energy Materials Property Database (REMPD), in response to that direction. The related full text of the Energy Act of 2020 is provided in Appendix A. The focus of the REMPD and this accompanying report is on quantifying the raw and processed materials used in renewable energy technologies. The database contains information on the amount of each material that goes into wind and solar power plants, descriptions of the relevant material properties, and the primary countries of origin for each material. Some materials go through several stages of processing and/or are incorporated into subcomponents that make up the completed energy generation facilities. This report does not analyze supply chains for the production of renewable energy plant components. The Department of Energy has carried out related analysis in response to Executive Order 14017, which directed production of "America's Supply Chains" reports for Wind and Solar. The supply chain reports can be found at https://www.energy.gov/sites/default/files/2022-02/Wind%20Supply%20Chain%20Report%20-%20Final%202.25.22.pdf (Wind) and https://www.energy.gov/sites/default/files/2022-02/Solar%20Energy%20Supply%20Chain%20Report%20-%20Final.pdf (Solar). Additional reports in this series that are relevant to wind, solar and hybrid plants include: Energy Storage at https://www.energy.gov/sites/default/files/2022-02/Energy%20Storage%20Supply%20Chain%20Report%20-%20final.pdf and Neodymium Magnets at https://www.energy.gov/sites/default/files/2022-02/Neodymium%20Magnets%20Supply%20Chain%20Report%20-%20Final.pdf.

14 SOLAR ENERGY↗

Wind data for wind driven plant

Simple, averaged wind velocity data provide information on energy availability, facilitate generator site selection and enable appropriate operating ranges to be established for windpowered plants. They also provide a basis for the prediction of extreme wind speeds.

Stodhart, A. H.↗

The hidden value of large-rotor, tall-tower wind turbines in the United States

The significant upscaling of wind turbine size (nameplate capacity, rotor diameter, and tower height) has, to date, been driven primarily by a goal of minimizing the levelized cost of energy. But with wind’s levelized cost of energy now comparable with that of other generating resources, other design considerations besides cost-minimization have grown in importance—particularly as wind’s increasing market penetration begins to impose challenges on the electric grid. We find that taller towers and larger rotors (relative to nameplate capacity) can enhance the value of wind energy to the electricity system and provide other “hidden” benefits. Specifically, in regions where wind penetration has reached around 20%, we find a boost in wholesale market value of US$2–US$3/MWh. This is augmented by transmission, balancing, and financing benefits that sum to roughly US$2/MWh. The aggregate potential value enhancement of US$4–US$5/MWh is comparable with a 10%–15% reduction in levelized costs.

17 WIND ENERGY↗

High temporal resolution generation expansion planning for the clean energy transition

As power systems integrate increasing quantities of wind, solar and energy storage resources, it is important to revisit power system capacity expansion modeling methods and assumptions that have been utilized in thermal- dominated systems. We conduct a series of case study analyses using a simplified representation of the Electric Reliability Council of Texas (ERCOT) system to demonstrate how least-cost capacity expansion outcomes are impacted by changes in model resolution across two temporal dimensions: 1) the number of considered representative periods, and 2) the system dispatch interval. First, we find that the least-cost generation portfolio can differ significantly for small changes in the number of representative days, but largely converges to the 365-day result once 104 representative days are considered. Furthermore, systems with wind, solar and storage resources were more sensitive to changes in the number of representative days than a thermal-dominated system. Second, we find that considering five-minute dispatch resolution consistently results in least-cost generation portfolios with less solar capacity and more energy storage capacity than corresponding scenarios with hourly dispatch intervals. This suggests that hourly dispatch representation fails to capture the intra-hour volatility of solar generation, and therefore also overlooks opportunities for storage resources to provide system value by balancing this volatility. Collectively these results indicate that capacity expansion modelers should revisit conventional approaches to temporal representation when conducting analyses of deeply decarbonized power systems to ensure that such analyses are robust and actionable. To our knowledge, this is the first study to analyze capacity expansion outcomes with five-minute dispatch resolution in this manner.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The locational value of distributed energy resources: A parcel-level evaluation of solar and wind potential in New York state

We report distributed energy resources (DERs) are poised to play a significant role in evolving power systems because of their flexibility to be sited in areas of high value to the grid. Traditional DER compensation frameworks, specifically net energy metering (NEM), inadequately communicate differences in the locational and temporal value of DER generation to the grid. As a transition from NEM, New York State's (NYS's) Value of Distributed Energy Resources (VDER) framework provides a methodology for calculating different value components that DERs offer the grid. To study the impacts of VDER frameworks on DER deployment, we developed a model to assess the value of distributed solar and wind systems configured as either a behind-the-meter system or a front-of-the-meter system for each parcel of land in NYS. Using parcel-level granularity, we can closely evaluate DER locational value and siting availability, particularly in urban and suburban settings. Our analysis finds while most DER generators would be modestly compensated for deferred transmission and distribution infrastructure upgrades (~0.01 $\$$/kWh for solar PV), a subset of projects receive significant value from this component (0.035 to 0.089 $\$$/kWh for top 5% of parcels for solar PV). Finally, our analysis finds VDER provides less overall compensation than NEM to the average DER generator, however, it increases access to compensation for front-of-the-meter DERs - a large and emerging market.

14 SOLAR ENERGY↗