Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “water heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Household energy resilience in extreme weather events: An investigation of energy service importance, HVAC usage behaviors, and willingness to pay

Household energy resilience, particularly maintaining essential energy services within an acceptable and affordable level, is critical during extreme weather events (e.g., winter storms, heat waves) with power shortages or outages. However, the research on the importance and acceptable compromise levels of energy services, HVAC usage behavior changes, and willingness to pay (WTP) for energy services during disasters is limited. Therefore, this study investigates the importance and compromise of household energy services, HVAC usage behaviors, and WTP, as three key dimensions of household energy resilience, in both normal days and disaster scenarios through surveys (n=485). First, 12 common residential end-uses are grouped into high, mid, and low-priority services using hierarchical clustering, in which high-priority services (perceived as important and un-compromisable) include food cooking and storage (refrigerator and freezer) and thermal comfort (space heating and cooling), mid-priority services involve water heating and lighting, while low-priority services are mostly related to entertainment and housework (e.g., TV, laundry). Also, HVAC use patterns demonstrate that occupants become more energy conservative during disasters, e.g., reducing durations of running HVAC and adjusting temperature setpoints to save energy. In terms of energy cost, approximately 60% of respondents are willing to pay more to maintain energy services during disasters, although only 13% are prepared to pay over double the normal energy prices. The regression models further reveal that household energy resilience varies across different sociodemographic groups (e.g., age, income, family size) and is impacted by disaster experience and beliefs in clean energy and climate. In conclusion, these research findings provide important perspectives to understand household energy resilience and inform measures for disaster adaptation of households in extreme weather events.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Heat Loss Characteristics and Energy Use of Piperazine with the Advanced Stripper (PZAS) at the UT-SRP Pilot Plant

Heat duty and heat loss were measured at the pilot plant at UT Austin. Heat loss was measured with energy balances using water. Heat loss was studied using surface temperature measurements over 68 different locations at the pilot plant. Surface temperature measurements indicated that bare metal surfaces were the primary source of heat loss from the pilot plant. Heat loss from bare metal surfaces was at least 50% controlled by natural convection and in many cases was as high as 75% natural convection controlled. Measured heat loss at the pilot plant was 20100 BTU/hr and overall heat loss did not show any dependence on the heat rate of the plant. Compared to PZAS™ at the National Carbon Capture Center, heat loss relative to heat rate was higher at 38%. The relative heat loss at the pilot plants was found to decrease by 20% per MW of added capacity. Measured net heat duty was found to be dependent on measured lean loading and cold rich bypass flow rate. Measured net heat duty was between 2.2 and 2.4 GJ/tonne at an optimum lean loading of 0.2–0.21 mol/mol. Data reconciliation by Aspen Plus® Data Fit™ underpredicted CO2 flow rate by 20% due to an overprediction of lean loading by 19%, indicating a necessary change in thermodynamic parameters in the model. This resulted in an over prediction of heat duty by 33% on average.

Amine scrubbing, stripper, energy requirement, hea↗

Commercial Building Stock Segmentation for Decarbonization Planning

This document discusses the development of a segmentation approach for the U.S. commercial building stock that is focused on identifying similarities that align with common decarbonization strategies. The resulting nine-segment approach primarily uses similarities in heating, ventilation, and air conditioning (HVAC) systems, service water heating systems, and presence of cooking equipment to separate buildings into categories.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Preliminary design package for maxi-therm heat exchanger module

Heat exchangers were developed for use in a solar heating and cooling system installed in a single family dwelling. Each of the three exchangers consisted of a heating and cooling module and a submersed electric water heating element. Information necessary to evaluate the preliminary design of the heat exchanger is presented in terms of the development and verification plans, performance specifications, installation and maintenance, and hazard analysis.

Source record↗

Passive thermosyphon solar heating and cooling module with supplementary heating

A collection of three quarterly reports from Sigma Research, Inc., covering progress and status from January through September 1977 are presented. Three heat exchangers are developed for use in a solar heating and cooling system for installation into single-family dwellings. Each exchanger consists of one heating and cooling module and one submerged electric water heating element.

Source record↗

Installation package for a solar heating and hot water system

Development and installation of two commercial solar heating and hot water systems are reported. The systems consist of the following subsystems: collector, storage, transport, hot water, auxiliary energy and controls. General guidelines are provided which may be utilized in development of detailed installation plans and specifications. In addition, operation, maintenance and repair of a solar heating and hot water system instructions are included.

Source record↗

Vapor pressures and calculated heats of vaporization of concentrated nitric acid solutions in the composition range 71 to 89 percent nitrogen dioxide, 1 to 10 percent water, and in the temperature range 10 to 60 degrees C

Total vapor pressures were measured for 16 acid mixtures of the ternary system nitric acid, nitrogen dioxide, and water within the temperature range 10 degrees to 60 degrees Celsius, and with the composition range 71 to 89 weight percent nitric acid, 7 to 20 weight percent nitrogen dioxide, and 1 to 10 weight percent water. Heats of vaporization were calculated from the vapor pressure measurements for each sample for the temperatures 25, 40, and 60 degrees Celsius. The ullage of the apparatus used for the measurements was 0.46. Ternary diagrams showing isobars as a function of composition of the system were constructed from experimental and interpolated data for the temperatures 25, 40, 45, and 60 degrees C and are presented herein.

Mckeown, A B↗

OpenStudio System-level KPI Reporting Measure v1.0

This is a OpenStudio measure that calculates and reports the system-level key performance indicators (KPIs) for evaluating building energy performance at the system level. The systems are defined by the service it provides in commercial buildings, which include (1) lighting, (2) Miscellaneous Electric Loads (MELs), (3) Heating, Ventilation and Air Conditioning (HVAC), and (4) Service Water Heating (SWH).

Li, Han↗

Design and Test Plans for a Non-Nuclear Fission Power System Technology Demonstration Unit

A joint National Aeronautics and Space Administration (NASA) and Department of Energy (DOE) team is developing concepts and technologies for affordable nuclear Fission Power Systems (FPSs) to support future exploration missions. A key deliverable is the Technology Demonstration Unit (TDU). The TDU will assemble the major elements of a notional FPS with a non-nuclear reactor simulator (Rx Sim) and demonstrate system-level performance in thermal vacuum. The Rx Sim includes an electrical resistance heat source and a liquid metal heat transport loop that simulates the reactor thermal interface and expected dynamic response. A power conversion unit (PCU) generates electric power utilizing the liquid metal heat source and rejects waste heat to a heat rejection system (HRS). The HRS includes a pumped water heat removal loop coupled to radiator panels suspended in the thermal-vacuum facility. The basic test plan is to subject the system to realistic operating conditions and gather data to evaluate performance sensitivity, control stability, and response characteristics. Upon completion of the testing, the technology is expected to satisfy the requirements for Technology Readiness Level 6 (System Demonstration in an Operational and Relevant Environment) based on the use of high-fidelity hardware and prototypic software tested under realistic conditions and correlated with analytical predictions.

Mason, Lee↗

Heat Transfer, Refrigeration and Heat Pumps

The Special Issue entitled “Heat Transfer, Refrigeration and heat Pumps” accepted papers covering a wide range of topics related to heat pumps, thermal energy storage, and low-Global Warming Potential (GWP) alternative refrigerants. Heat pumps play a vital role in providing space conditioning and water heating while utilizing the energy of the environment. Since heat pumps use renewable thermal energy from the environs to provide the desired utility, they contribute to the portfolio of technologies that mitigate carbon footprint. The heat pump may be considered a truly renewable technology if the electricity it uses comes entirely from a renewable source. More accurately, a heat pump is a “low carbon technology”. These perspectives make heat pumps an indispensable option for the future in order to reduce the nocuous human impact on the environment. More efficient heat pumping technologies are being developed for the residential, commercial, and industrial sectors of the economy. Another R&D thrust is heat pumps for cold climates. Hardware components, use of low-GWP refrigerants, and identification of systemic inefficiencies are active research areas. This article is a synopsis of the papers submitted to the Special Issue.

42 ENGINEERING↗

Optimization and Experimental Validation of Annular Finned PCM-HX for a Domestic Hot Water Heater Application

The load profile for domestic water heating is time-dependent and can result in high energy demand during peak operating times. Shifting this peak load can have significant environmental and economic impacts. Phase change material (PCM)-based thermal energy storage (TES) is a potentially useful technology for peak load shifting in domestic hot water (DHW) applications thanks to its high latent heat and energy density. In this study, an annular finned-tube PCM-HX design concept was optimized for a load-shifting TES unit to meet the Department of Energy standard for a medium-usage DHW heater using a resistance-capacitance model (RCM) integrated with a Multi-Objective Genetic Algorithm. The optimized design comprised 70 identical annular finned-tube PCM-HX units connected in parallel and utilizing RT62HC as the PCM. A single PCM-HX unit was prototyped and tested in a vertically oriented setup with upward heat transfer fluid (HTF) flow. The hot water supply time was defined based on a cutoff temperature of 51.7°C. The as-designed mass flow rate (1.5 g/s) was tested to assess the performance of the prototyped PCM-HX unit for RCM validation. For the experimental investigation, RTD sensor bundles measured HTF temperature at the PCM-HX inlet and outlet, and a Coriolis flow meter accurately measured the HTF mass flow rate. The simulated discharging power underpredicted the experimental result by about 12%, and the simulated hot water supply time underpredicted the experimental result by approximately 13% for the as-designed mass flow rate (1.5 g/s). The average deviation of the hot water supply temperature between the experimental and RCM results during the complete PCM solidification process was 1.3 K for the as-designed mass flow rate. The overall good agreement between the experimental and RCM results provides confidence that computationally efficient models such as RCM can be utilized for design optimization of PCM-HXs.

42 ENGINEERING↗

Solar-heating system-performance tests

Report describes comprehensive performance tests of complete solar powered space and hot water heating system to verify its suitability for field installation in small single family dwellings.

Source record↗

Solar heating and hot water system installed at Cherry Hill, New Jersey

The solar heating and hot water system installed in existing buildings at the Cherry Hill Inn in Cherry Hill, New Jersey is described in detail. The system is expected to furnish 31.5% of the overall heating load and 29.8% of the hot water load. The collectors are liquid evacuated tube type. The storage system is an above ground insulated steel water tank with a capacity of 7,500 gallons.

Source record↗

A study of circumferentially-heated and block-heated heat pipes. I - Experimental analysis and generalized analytical prediction of capillary limits. II - Three-dimensional numerical modeling as a conjugate problem

The wall and centerline vapor temperatures and heat output are determined experimentally for a low-temperature copper-water heat pipe under uniform circumferential heating and block heating. The time required to reach a vapor temperature of 60 C from an initial ambient temperature of 21 C is determined for both modes of heating. The experimental capillary limit of the heat pipe is compared to the generalized capillary limits for block-heated pipes over a range of vapor temperatures. A three-dimensional numerical model is then developed for determining the temperature, pressure, and velocity distributions in the entire domain of a circumferentially heated and a block-heated pipe. The problem is formulated as a conjugate problem, without the assumption of a uniform vapor temperature. The predictions of the model are found to be in good agreement with the experimental data.

Schmalhofer, Joseph↗

High Temperature Heat Pumps and Their Roles in the Decarbonization of Building and Industry

Heat pumps have been sought as a promising technology for air and water heating processes in buildings. Several OEMs have been commercializing heat pumps with varying capacities; However, the application has been limited to lower temperatures (less than 70℃). With the recently growing interest in replacing gas-fired equipment for buildings and industrial processes, a new class of heat pumps, known as high-temperature heat pumps, is gaining substantial interest where the target temperatures are higher than the conventional heat pump technology (greater than 90℃). The current study is focused on this class of heat pumps and aims to provide a holistic overview of state-of-the-art technology while highlighting major challenges and opportunities. The discussion will be focused on the availability of technology to enable higher sink temperatures, deployment-based applications, waste heat recovery, and process integration and controls.

Nawaz, Kashif↗

Motel solar-hot-water system with nonpressurized storage--Jacksonville, Florida

Modular roof-mounted copper-plated arrays collect solar energy; heated water drains from them into 1,000 gallon nonpressurized storage tank which supplies energy to existing pressurized motel hot water lines. System provides 65 percent of hot water demand. Report described systems parts and operation, maintenance, and performance and provides warranty information.

Source record↗