Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “water evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Molecular dynamics simulation studies of 1,3-dimethyl imidazolium nitrate ionic liquid with water

The fundamental understanding of intermolecular interactions of ionic liquids (ILs) with water is essential in predicting IL–water thermodynamic properties. In this study, intermolecular or noncovalent interactions were studied for 1,3-dimethyl imidazolium [DMIM]+ cation and nitrate [NO 3 ] – anion with water, employing quantum mechanics and molecular dynamics simulations. Molecular dynamics simulations were performed using a revised multipolar polarizable force field. The effect of water on ionic liquids was evaluated in terms of thermodynamic and dynamic properties. Thermodynamic properties included liquid densities ρ, excess molar volumes ΔV E , and liquid structures g(r)⁠. Dynamic properties included self-diffusion coefficients D of mixture constituents as a function of water concentration. The density of ionic liquid–water mixtures monotonically decrease with increasing concentration of water. A negative excess volume was obtained for low and high water concentrations, demonstrating strong intermolecular interactions of water with ionic liquid components. Liquid structures of ionic liquid–water mixtures revealed a tendency for anions to interact with cations at shorter intermolecular distances when the water concentration is increased. Diffusion rates were found to increase for all mixture components with increase in the fraction of water. A significant change in the diffusion rate was found at ~0.3 weight fraction of water. However, the water self-diffusion coefficient was dominant at all concentrations. Furthermore, the ratio of water/anion and anion/cation self-diffusion coefficients was found to decrease linearly with increasing concentration of water molecules.

36 MATERIALS SCIENCE↗

Specific conductivity and salinity of the Parker River, PIE LTER, Plum Island Sound MA, August-November 2022

This dataset contains specific conductivity and calculated salinity data of Parker River water at a tidal brackish wetland dominated by Typha angustifolia at the upper estuary of the Plum Island Sound in Newbury, Massachusetts (MA) within the Plum Island Ecosystems Long Term Ecological Research site (PIE LTER). Measurements were taken to evaluate temporal changes in surface water salinity in high frequency to characterize boundary conditions of soil and plant responses to changes in salinity. A PVC pipe was installed in a low elevation spot in the creek bank so that the bottom of the pipe sat on the sediment surface allowing flushing with water during flooding. Raw measurements were collected using an Onset HOBO U24-002 Saltwater Conductivity/Salinity data logger. The specific conductance and salinity measurements were corrected and calculated respectively using Onset’s HOBOware software and reference specific conductivity measurements taken in tandem with the first and last points recorded by the HOBO sensor. These reference measurements were taken using a HACH HQ14D Portable Conductivity Meter. Because of the installation design, only data one hour before and after high tide are used. Metadata files Typha_ctd_salinity_dd.csv and Typha_ctd_salinity_flmd.csv contain detailed information on data variables, sampling and QA/QC methods, and site location.

54 ENVIRONMENTAL SCIENCES↗

Specific conductivity and salinity of the Parker River, PIE LTER, Plum Island Sound MA, March-November 2023

This dataset contains specific conductivity and calculated salinity data of Parker River water at a tidal brackish wetland dominated by Typha angustifolia at the upper estuary of the Plum Island Sound in Newbury, Massachusetts (MA) within the Plum Island Ecosystems Long Term Ecological Research site (PIE LTER). Measurements were taken to evaluate temporal changes in surface water salinity in high frequency to characterize boundary conditions of soil and plant responses to changes in salinity. A PVC pipe was installed in a low elevation spot in the creek bank so that the bottom of the pipe sat on the sediment surface allowing flushing with water during flooding. Raw measurements were collected using an Onset HOBO U24-002 Saltwater Conductivity/Salinity data logger. The specific conductance and salinity measurements were corrected and calculated respectively using Onset’s HOBOware software and reference specific conductivity measurements taken in tandem with the first and last points recorded by the HOBO sensor. These reference measurements were taken using a HACH HQ14D Portable Conductivity Meter. Because of the installation design, only data one hour before and after high tide are used. Metadata files Typha_ctd_salinity_dd.csv and Typha_ctd_salinity_flmd.csv contain detailed information on data variables, sampling and QA/QC methods, and site location.

54 ENVIRONMENTAL SCIENCES↗

Evaluating Enhanced Reservoir Evaporation Losses From CMIP6‐Based Future Projections in the Contiguous United States

Abstract Enhanced reservoir evaporation has become an emerging concern regarding water loss, especially when compounded with the ever‐increasing water demand. In this study, we evaluated the evaporation rates and losses for 678 major reservoirs (representing nearly 90% of total storage capacity) in the Contiguous United States over historical baseline (1980–2019), near‐term (2020–2039), and mid‐term (2040–2059) future periods. The evaporation rate was estimated using the Lake Evaporation Model (LEM), an advanced lake evaporation model that addresses both heat storage and fetch effects, driven by multi‐ensemble downscaled Coupled Model Intercomparison Projects 6 (CMIP6) projections under the SSP585 emission scenario. The results project that the evaporation loss may increase by 2.5 × 10 7 m 3 /yr through the research period (1980–2059). Among all regions, the Rio Grande is projected to have the largest increasing rate in the near‐term and mid‐term future, with values of 7.11% of 10.25%, respectively. At the seasonal scale, the most significant increase in the evaporation rate is projected during the fall. The evaporation is projected to increase faster than the streamflow over many of the regions in the southwestern US during the summer/fall, suggesting that the shortage of water will be further exacerbated. The climate models contribute the most to the variance, as compared to the other components related to the projection of evaporation losses (e.g., hydrological model, downscaling method, and historical meteorological data set). These findings demonstrate the need to consider accelerated water loss through open water evaporation in long‐term water resources planning across various spatiotemporal scales.

54 ENVIRONMENTAL SCIENCES↗

3D printing of packaging inserts from biomass-fungi composites: Environmental sustainability analysis

In this study, a comprehensive Life cycle assessment (LCA) is conducted on molded packaging inserts from expanded polystyrene (EPS) foam, molded packaging inserts from biomass-fungi composite, and 3D-printed packaging inserts from biomass-fungi composite under the low mix / high volume (LMHV) scenario and molded and machined packaging inserts from EPS foam, molded and machined packaging inserts from biomass-fungi composite, and 3D-printed packaging inserts from biomass-fungi composite under the high mix / low volume (HMLV) scenario. Six environmental impact categories—climate change, acidification, eutrophication, fossil resource scarcity, land use, and water consumption—are analyzed to evaluate the environmental trade-offs associated with each type of packaging inserts. Under the LMHV scenario, molded packaging inserts from biomass-fungi composite emerge as the best option due to their lower impact on climate change, acidification and water consumption compared to other types of packaging inserts. Conversely, molded packaging inserts from biomass-fungi composite face challenges in land use and eutrophication, primarily due to raw material production. LCA also reveals that 3D-printed packaging inserts from biomass-fungi composite are the most environmentally favorable option under the HMLV scenario, due to significantly lower contributions to climate change, eutrophication, and water consumption compared to other types of packaging inserts. Conversely, 3D-printed packaging inserts from biomass-fungi composite face challenges in acidification and land use, primarily due to raw material production. As part of the LCA, sensitivity analyses show that sourcing energy from 100% renewable sources substantially lowers climate change impacts across all packaging types, while varying transportation distances results in only minor changes, indicating the dominant role of upstream material and manufacturing processes. Additional sensitivity analysis is conducted under the HMLV scenario to assess the impact of material removal during machining on the environment. The amount of material removal is varied from 10 to 70% for the sensitivity analysis and it highlights that the amount of material removed during machining has no significant impact on climate change for packaging inserts from EPS foam. However, molded and machined packaging inserts from biomass-fungi composite show an increasing trend in climate change with higher amount of material removal, while 3D-printed packaging inserts from biomass-fungi composite exhibit a decreasing trend, driven by reduced raw material usage and energy consumption.

09 BIOMASS FUELS↗

Case Study of Integrating High-Temperature Heat Pump with LiBr-H2O Absorption Chiller for Data Center Liquid Cooling

Data centers (DCs) are physical infrastructures that support artificial intelligence workloads. The rapid growth of artificial intelligence is putting substantial pressure on the US power grid. Most of electricity consumed by IT equipment, accounting for 50%-60% of total DC power, ultimately becomes waste heat. This heat is dissipated by DC’s cooling facilities, accounting for an additional 30%-40% of total DC power. Recovering and repurposing this waste heat offers a significant opportunity to enhance energy efficiency and reduce operating costs of DCs. One potential pathway is converting heat to cold using thermal-driven absorption chillers, therefore, reducing the power consumption in DC cooling facilities. Existing studies mainly demonstrate the technical and economic feasibility of repurposing DC’s waste heat for cooling applications but provide limited technical details on how to integrate the thermal-driven absorption chillers with DC cooling systems. In addition, the low-grade waste heat available from DCs must be upgraded to higher temperatures suitable for absorption chillers. This paper presents a case study on integrating high-temperature heat pumps with a LiBr-H2O absorption chiller to use DC waste heat for cooling. A thermodynamic model of single-effect, LiBr-H2O absorption chiller and an empirical model of high-temperature heat pumps were built. The case study considers ASHRAE W17 liquid-cooled DC, with facility service water supplied at 17.0℃ and returned at 25.3℃. The thermal behaviors of absorption chiller components were predicted for the generation temperature ranging from 75.0℃ to 115.0℃. Based on the available waste heat in the integrated system, two waste heat recovery strategies were evaluated: a facility service water-based strategy and cooling water-based strategy. Results indicated that the cooling water-based strategy achieves higher Coefficient of Performance (COPs) than the facility service water-based strategy. The relatively low cooling COPs of single-effect LiBr-H2O absorption chillers could be offset by high heating COP of high temperature heat pumps. The maximum cooling COP of absorption chiller and the overall COP of integrated systems occur at lower generation temperatures, but these conditions also yield lower cooling capacities. In practice, system operation should balance the trade-off between the COP and cooling capacity

Wang, Pengtao [ORNL] (ORCID:0000000214713429)↗

De-Risking High-Recovery Brackish Water Desalination via Flow Reversal and Feed Flushing Using Techno-Economic Assessment

Novel desalination technologies have demonstrated enhanced performance and improved financial metrics over existing processes adopted by industry. Establishing quantitative performance targets is essential for achieving financial benefits over the current state of the art. Herein, we demonstrate how WaterTAP, a techno-economic assessment (TEA) tool, can be used to identify minimum performance metrics necessary to achieve financial benefit over using existing processes. This study evaluates the feasibility of increasing water recovery at the Chino Desalter I above 90 % through the addition of a third variable configuration reverse osmosis (VCRO) stage. Sensitivity analyses revealed flow reversal frequency, feed flushing volume (used as a cleaning step), and membrane lifespan are key factors influencing the financial viability of the VCRO process. The TEA analysis demonstrated that the system must achieve a recovery of 84 % and a 1-year membrane lifespan to have a breakeven LCOW, while achieving 90 % recovery can ultimately reduce the LCOW by 16 %. Notably, a trade-off between decreasing frictional losses and increased osmotic pressure across the recovery range, resulted in a stable specific energy consumption across the recovery range, enabling meaningful LCOW reductions without an energy penalty, a key finding that contrasts with conventional RO. This work demonstrates how TEA can guide system design by identifying key performance targets and exploring trade-offs, enabling data-driven decisions to de-risk innovative processes. These findings underscore the importance of leveraging TEA to evaluate scaling mitigation strategies and optimize inland desalination systems for sustainable and cost-effective operation.

14 SOLAR ENERGY↗

Effect of Block Length on the Properties of Multiblock Polysulfone-Poly(diallylpiperidinium hydroxide) Anion Exchange Membranes

Research in anion exchange membranes (AEM)s has continued with the development of materials bearing base stable cations. Designing AEMs that microphase separate into hydroxide conductive, hydrophilic domains within a hydrophobic and mechanically robust matrix has been shown to be successful for improving AEM performance. A series of multiblock polysulfone-poly(diallylpiperidinium hydroxide) copolymers (PSf-PDApipOH) of similar hydrophobic/hydrophilic composition was prepared in which the molecular weight of the hydroxide conducting PDApipOH segments was varied. The variable hydrophilic segment molecular weight was designed to assess the impact on microphase separation, hydroxide conductivity, and water management. The multiblock copolymers investigated were prepared by condensation polymerization of preformed4-fluorophenyl sulfone terminated poly(diallylpiperidinium hexafluorophosphate) (PDApipPF6) oligomers with polysulfone monomers. The structure-property relationship between the molecular weight of the conductive PDApipOH segments and AEM performance was demonstrated by evaluation of the microphase separation, water uptake, and hydroxide conductivity. Further, membranes fabricated from the polysulfone-poly(diallylpiperidinium hexafluorophosphate) (PSf-PDApipPF6) multiblock copolymers were shown to form well-connected conductive domains by SAXS and atomic force microscopy experiments. The PSf-PDApipOH membranes were highly conductive with the maximum hydroxide conductivity reaching 62.9 mS∙cm -1 at 60°C and 95% relative humidity. Furthermore, it was demonstrated that the conductivity increased with increasing PDApipOH segment molecular weight.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

MeV-scale performance of water-based and pure liquid scintillator detectors

This paper presents studies of the performance of water-based liquid scintillators (WbLS) in both 1-kt and 50-kt detectors. In this work, performance is evaluated in comparison to both pure water Cherenkov detectors and a nominal model for pure scintillator detectors. Performance metrics include energy, vertex, and angular resolution, along with a metric for the ability to separate the Cherenkov from the scintillation signal as being representative of various particle identification capabilities that depend on the Cherenkov/scintillation ratio. We also modify the time profile of scintillation light to study the same performance metrics as a function of rise and decay time. We go on to interpret these results in terms of their impact on certain physics goals, such as solar neutrinos and the search for Majorana neutrinos. This work supports and validates previous results, and the assumptions made therein, and serves as a significant stepping stone to complete detector design studies by using a more detailed detector model and full reconstruction, with a primarily data-driven optical model, and fewer model assumptions. With this model, a high-coverage 50-kt detector achieves better than 10 (1)% precision on the flux of neutrinos from the Carbon-Nitrogen-Oxygen cycle with a water-based liquid scintillator (pure LS) target in five years of data taking. A 1-kt LS detector, with a conservative 50% fiducial volume of 0.5 kt, can achieve better than 5% detection. A liquid scintillator detector has sensitivity into the normal hierarchy region for Majorana neutrinos with half-life sensitivity of $T^{0νββ}_{1/2}$ > 1.4 × 10 28 years at 90% C.L. for 10 years of data taking with a Te-loaded target.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Distribution of Antibiotic Resistance in a Mixed-Use Watershed and the Impact of Wastewater Treatment Plants on Antibiotic Resistance in Surface Water

The aquatic environment has been recognized as a source of antibiotic resistance (AR) that factors into the One Health approach to combat AR. To provide much needed data on AR in the environment, a comprehensive survey of antibiotic-resistant bacteria (ARB), antibiotic resistance genes (ARGs), and antibiotic residues was conducted in a mixed-use watershed and wastewater treatment plants (WWTPs) within the watershed to evaluate these contaminants in surface water. A culture-based approach was used to determine prevalence and diversity of ARB in surface water. Low levels of AR Salmonella (9.6%) and Escherichia coli (6.5%) were detected, while all Enterococcus were resistant to at least one tested antibiotic. Fewer than 20% of extended-spectrum β-lactamase (ESBL)-producing Enterobacteriaceae (17.3%) and carbapenem-resistant Enterobacteriaceae (CRE) (7.7%) were recovered. Six ARGs were detected using qPCR, primarily the erythromycin-resistance gene, ermB. Of the 26 antibiotics measured, almost all water samples (98.7%) had detectable levels of antibiotics. Analysis of wastewater samples from three WWTPs showed that WWTPs did not completely remove AR contaminants. ARGs and antibiotics were detected in all the WWTP effluent discharges, indicating that WWTPs are the source of AR contaminants in receiving water. However, no significant difference in ARGs and antibiotics between the upstream and downstream water suggests that there are other sources of AR contamination. The widespread occurrence and abundance of medically important antibiotics, bacteria resistant to antibiotics used for human and veterinary purposes, and the genes associated with resistance to these antibiotics, may potentially pose risks to the local populations exposed to these water sources.

60 APPLIED LIFE SCIENCES↗

Scoping Study of Integrated Geothermal CO 2 Heat Pump and Water Well System in Cold Climate Region (CRADA Final Report)

This study evaluates the feasibility of using ground-source heat pumps (GSHPs) integrated with water wells for residential heating demands in cold regions of the United States. Four different heat pump systems were evaluated and compared: a CO 2 air-source heat pump (ASHP), a R-410A ASHP, a CO 2 GSHP integrated with well water, and a R-410A GSHP integrated with well water. Simulations were conducted at both equipment and building integration levels, followed by a nationwide analysis across 10 selected cities. Results indicate that integrating GSHP technology with existing water wells (e.g., artesian, bedrock, drilled, and collector wells) is a feasible heating solution because of their high flow rates, good water quality, stable temperatures, and low environmental impact. Although R-410A systems demonstrate higher efficiency, CO 2 systems are more suitable for heating from contamination-free and energy security perspective. The CO 2 GSHPs maintain better performance in colder climates compared with that of ASHPs, providing higher coefficient of performance and environmental benefits because CO 2 refrigerant leakage would not contaminate well water. A national analysis confirms that CO 2 GSHPs outperform furnaces, especially in cold climates, making them a promising solution for residential heating.

15 GEOTHERMAL ENERGY↗

Are You Resilient? Site Energy and Water Resilience Indicators

There is growing interest among operators of individual or co-located facilities to plan for utility disruptions caused by natural hazards and threats. Energy and water resilience at the site level can be characterized as the ability to withstand, adapt, and recover from an energy and/or water supply disruption. But how can a site’s energy and water resilience posture be measured? An evaluation framework with clear performance measures or indicators can help organizations establish what it means to be energy and water resilient and assess progress towards meeting resilience goals across sites and over time. Tracking a consistent set of indicators can help organizations identify problem areas that should be addressed and ascertain if energy and water resilience has improved as a result of investments or operational or policy changes. Resilience indicators also provide a means for organizations with geographically distributed sites to identify common problem areas that may require higher-level attention. This paper outlines an approach that organizations can use to measure site energy and water resilience. This approach was developed by Pacific Northwest National Laboratory for the U.S. Department of Energy’s Federal Energy Management Program as part of an effort to help federal agencies plan for energy and water resilience in a more systematic and rigorous way. The paper defines a general structure for defining energy and water resilience indicators, and provides example indicators and potential rating methods.

resilience, metrics for resilience, site resilienc↗

Evaluation of distributed process-based hydrologic model performance using only a priori information to define model inputs

Fully distributed, integrated surface–subsurface hydrological models (ISSHMs) have seen renewed interest due to availability of better software, high performance computing facilities, and high-resolution, spatially extensive data products. ISSHMs are valuable as tools for advancing system understanding as they can resolve multiple processes defined on the plot scale including three-dimensional interaction of surface water and groundwater. Here, we evaluated the performance of an ISSHM, the Advanced Terrestrial Simulator (ATS), on seven diverse catchments across the continental US using widely available data products to define model inputs without calibration. We compare the ATS-simulated streamflow and evapotranspiration with gauge observations and MODIS-derived evapotranspiration, respectively. Using the Kling-Gupta Efficiency (KGE) as metric, ATS with default data products performed reasonably well at 6 of 7 catchments for streamflow. However, in one of those 6 catchments ATS had poor performance on baseflow and ATS’s overall performance was thus judged to be inadequate despite the acceptable KGE. ATS performance for evapotranspiration was good in all 7 catchments using default data products. In the two catchments where ATS streamflow performance using default data products was not acceptable, the performance was significantly improved by using local information on subsurface properties below the soil. We also compare the model-simulated streamflow and evapotranspiration with the Sacramento soil moisture accounting (SAC-SMA) model, a semi-distributed model that was calibrated on a catchment-by-catchment basis. Uncalibrated ATS performance is comparable to the calibrated SAC-SMA model in terms of streamflow while ATS performance is similar to or better (much better in certain catchments) in reproducing MODIS-derived evapotranspiration. Reasonably good performance of ATS without catchment-specific calibration provides new confidence in the ISSHM class of models and community data products as tools for advancing understanding of watershed function in a changing environment.

54 ENVIRONMENTAL SCIENCES↗

Photocatalytic water splitting

With the goal of achieving large-scale H 2 production from renewable resources, water splitting into H 2 and O 2 using semiconductor photocatalysts (sometimes called artificial photosynthesis) has been studied for five decades. Unfortunately, the lack of rigour and reproducibility in the data collection and analysis of experimental results has hindered progress in the field. This Primer provides a comprehensive overview of proper characterization and evaluation of photocatalysts for overall water splitting. In particular, the Primer covers various pitfalls in photocatalysis research, best practices for reproducibility and reliable methods for conducting rigorous experiments. As a result, the recommendations are intended to reduce false positives in the literature and to promote progress towards a practical technology for producing H 2 from water by using sunlight.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modeling the Water Systems of the Western US to Support Climate‐Resilient Electricity System Planning

Abstract Electricity and water systems in the Western US (WUS) are closely connected, with hydropower comprising 20% of total annual WUS generation, and electricity related to water comprising about 7% of total WUS electricity use. Because of these interdependencies, the threat of climate change to WUS resources will likely have compounding electricity impacts on the Western Interconnect grid. This study describes a WUS‐wide water system model with a particular emphasis on estimating climate impacts on hydropower generation and water‐related electricity use, which can be linked with a grid expansion model to support climate‐resilient electricity planning. The water system model combines climatically‐driven physical hydrology and management of both water supply and demand allocation, and is applied to an ensemble of 15 climate scenarios out to 2050. Model results show decreasing streamflow in key basins of the WUS under most scenarios. Annual water‐related electricity use increases up to 4%, and by up to 6% during the summer months, driven by growing agricultural demands met increasingly through a shift toward energy‐intensive groundwater to replace declining surface water. Total annual hydropower generation changes by +5% to −20% by mid‐century but declines in most scenarios, with decreases in summer generation by up to nearly −30%. Water‐related electricity use increases tend to coincide with hydropower generation declines, annually and seasonally, demonstrating the importance of concurrently evaluating the climate signal on both water‐for‐energy and energy‐for‐water to inform planning for grid reliability and decarbonization goals.

13 HYDRO ENERGY↗

Survey of Technologies to Meet PAG limits for Detection of Cesium-137 in Water

The goal of this report is to evaluate the process of adding a sorbent to the sampling process to preconcentrate Cs-137 and then analyze the sorbent to provide a rapid assessment of results to guide decisions on drinking water sources and the protection of the public. Multiple unit design variables were considered: sample configuration/geometry, sorbent efficiency, sample volume. Model simulations demonstrated through these unit design efficiencies that 10 L of sample volume processed through a sorbent provides nearly two orders of magnitude improvement in sample counting time to provide results to a decision maker than the current process. Over 60 publications and reports concerning Cs-137 and sorbents were evaluated. The key attributes were readiness of sorbent to be deployed in a mobile laboratory environment, and minimum sample preparation and conditioning. Examples of sorbents not considered further included nanomaterials, which have not been evaluated at a commercial scale and are limited in availability. The recommended sorbents for further consideration include: ferrocyanide salts, zeolite, and chemically modified granular activated carbon.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Assessment of Commercial Building Lighting as a Frequency Regulation Resource

This paper evaluates the potential for automated lighting control as a resource for frequency regulation of the electric grid system in the context of current energy policies, economic incentives, and technological trends. The growing prevalence of renewable energy has increased the need for ancillary services to maintain grid frequency and stability. While demand side resources like heating, ventilating, and air-conditioning systems, as well as water treatment plants are already evaluated as regulation service providers, the potential application to electrical lighting systems has largely been ignored. Yet, aggregations of lighting systems that are retrofitted with intelligent controls could conceivably contribute to frequency regulation services with little impact on user comfort. To further explore the feasibility of lighting potential, this paper explores (1) how lighting control systems are limited by visual comfort perception and acceptability, (2) how such limitations impact the performance of the lighting system as an frequency regulation resource, and (3) how the market potential of lighting systems as demand side resources compares in different regional transmission organizations. Finally, the impact of developing technologies on the application of lighting systems for frequency regulation is discussed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗