Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “volume visualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Role of Adaptive Radiotherapy During Concomitant Chemoradiotherapy for Lung Cancer: Analysis of Data From a Prospective Clinical Trial

Purpose: Respiratory-gated radiotherapy allows for the reduction of the toxicity associated with concomitant chemoradiotherapy, but the smaller fields used could increase the risk of missing the target. A prospective study was performed to evaluate the dosimetric consequences of time-trend changes in patients with lung cancer who were treated with concomitant chemoradiotherapy. Methods and Materials: A total of 24 lung cancer patients eligible for chemoradiotherapy and gated delivery underwent four-dimensional computed tomography (4D-CT) after 15 fractions. This scan was co-registered with the initial planning 4D-CT and a new planning target volume (PTV) was generated on the basis of the tumor visualized after 15 fractions. Coverage of the repeat PTV was evaluated by applying the original plan to the second scan and recalculating the dose. Plan modification was triggered by a 5% reduction in the PTV included within the 95% isodose volume or an unacceptable increase in the critical organ dose. Results: Of the 21 evaluable patients, 15 had an average reduction in the PTV of 8% after 30 Gy. The PTV increased in the remaining 6 patients, but the increase was >20% in only 1 patient. In the latter patient, disease progression was observed, and repeat planning was required. The plans created using the new PTV were acceptable in all the other patients. Conclusion: The role of adaptive radiotherapy appears limited when respiratory-gated radiotherapy is used to reduce the toxicity related to concomitant chemoradiotherapy. The use of more conformal treatment techniques might provide the rationale for repeat imaging as a method to identify patients at risk of dosimetric miss.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Adaptive Radiotherapy for Bladder Cancer—A Systematic Review

Radiotherapy has been offered as a multimodality treatment for bladder cancer patients. Due to the significant variation of bladder volume observed throughout the course of treatment, large margins in the range of 20–30 mm have been used, unnecessarily irradiating a large volume of normal tissue. With the capability of visualizing soft tissue in cone beam computed tomography, there is opportunity to modify or to adapt the plan based on the variation observed during the course of treatment for quality improvement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Real-time streaming tomographic reconstruction with on-demand data capturing and 3D zooming to regions of interest

Complex dynamic tomographic experiments at brilliant X-ray light sources require real-time feedback on the sample changes with respect to environmental conditions, selecting representative regions of interest for high-resolution scanning, and on-demand data saving mechanisms for storing only relevant projections acquired by fast area detectors and reducing data volumes. Here the implementation details of a 3D real-time imaging monitoring instrument, with zooming to a volume of interest with easy-to-use visualization via ImageJ , a tool familiar to most beamline users, is presented. The instrument relies on optimized data flow between the detector and processing machines and is implemented on commodity computers. The instrument has been developed at beamline 2-BM of the Advanced Photon Source, where the automatic lens changing mechanism for zooming is implemented with an Optique Peter microscope. Performance tests demonstrate the ability to process more than 3 GB of projection data per second and generate real-time 3D zooming with different magnification. These new capabilities are essential for new APS Upgrade instruments such as the projection microscope under development at beamline 32-ID. The efficacy of the proposed instrument was demonstrated during an in situ tomographic experiment on ice and gas hydrate formation in porous samples.

3D zooming↗

A Scalable Hybrid Scheme for Ray-Casting of Unstructured Volume Data

We present an algorithm for parallel volume rendering that is a hybrid between classical object order and image order techniques. The algorithm operates on unstructured grids (and structured ones), and thus can deal with block boundaries interleaving in complex ways. It also deals effectively with cases that are prone to load imbalance, i.e., cases where cell sizes differ dramatically, either because of the nature of the input data, or because of the effects of the camera transformation. The algorithm divides work over resources such that each phase of its processing is bounded in the amount of computation it can perform. We demonstrate its efficacy through a series of studies, varying over camera position, data set size, transfer function, image size, and processor count. At its biggest, our experiments scaled up to 8,192 processors and operated on data sets with more than one billion cells. In total, we find that our hybrid algorithm performs well in all cases. This is because our algorithm naturally adapts its computation based on workload, and can operate like either an object order technique or an image order technique in scenarios where those techniques are efficient.

97 MATHEMATICS AND COMPUTING↗

Analysis of Doppler Lidar Data Acquired During the Pentagon Shield Field Campaign

Observations from two coherent Doppler lidars deployed during the Pentagon Shield field campaign are analyzed in conjunction with other sensors to characterize the overall boundary-layer structure, and identify the dominant flow characteristics during the entire two-week field campaign. Convective boundary layer (CBL) heights and cloud base heights (CBH) are estimated from an analysis of the lidar signal-to-noise-ratio (SNR), and mean wind profiles are computed using a modified velocity-azimuth-display (VAD) algorithm. Three-dimensional wind field retrievals are computed from coordinated overlapping volume scans, and the results are analyzed by visualizing the flow in horizontal and vertical cross sections. The VAD winds show that southerly flows dominate during the two-week field campaign. Low-level jets (LLJ) were evident on all but two of the nights during the field campaign. The LLJs tended to form a couple hours after sunset and reach maximum strength between 03 and 07 UTC. The surface friction velocities show distinct local maxima during four nights when strong LLJs formed. Estimates of the convective boundary layer height and residual layer height are obtained through an analysis of the vertical gradient of the lidar signal-to-noise-ratio (SNR). Strong minimum in the SNR gradient often develops just above the surface after sunrise. This minimum is associated with the developing CBL, and increases rapidly during the early portion of the daytime period. On several days, this minimum continues to increase until about sunset. Secondary minima in the SNR gradient were also observed at higher altitudes, and are believed to be remnants of the CBL height from previous days, i.e. the residual layer height. The dual-Doppler analysis technique used in this study makes use of hourly averaged radial velocity data to produce three-dimensional grids of the horizontal velocity components, and the horizontal velocity variance. Visualization of horizontal and vertical cross sections of the dual-Doppler wind retrievals often indicated a jet-like flow feature over the Potomac River under southerly flow conditions. This linear flow feature is roughly aligned with the Potomac River corridor to the south of the confluence with the Anatostia River, and is most apparent at low levels (i.e. below ~150 m MSL). It is believed that this flow arises due to reduced drag over the water surface and when the large scale flow aligns with the Potomac River corridor. A so-called area-constrained VAD analysis generally confirmed the observations from the dual-Doppler analysis. When the large scale flow is southerly, wind speeds over the Potomac River are consistently larger than the at a site just to the west of the river for altitudes less than 100 m MSL. Above this level, the trend is somewhat less obvious. The data suggest that the depth of the wind speed maximum may be reduced by strong directional shear aloft.

54 ENVIRONMENTAL SCIENCES↗

Characterization of Infrequent Samples from the Concentration, Storage, and Transfer Facility: F-Area Pump Pit 3 (FPP-3) Sump Sample: December 2021 Sample

In December 2021, SRR-E sent an ~185 mL sample identified as FPP-3 from a F-Area pump pit sump to SRNL for analysis. The sample was pale yellow in color and contained a small amount of suspended solids visually estimated to be less than 1% by volume. SRNL analysis indicated that the sample contained 4.4 E+05 dpm/mL Cs-137, 6.2 E+05 dpm/mL total beta activity, 9.3 E+02 dpm/mL beta activity following cesium removal, and below detectable levels of alpha activity following cesium removal. In addition, the sample contained 0.015 M free OH- and 947 μg total organic carbon/mL.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization of Infrequent Samples from the Concentration, Storage, and Transfer Facility: H-Area Diversion Box 1 (HDB-1) Sump Sample: January 25, 2022 Sample

Savannah River Remediation Engineering (SRR-E) requested that the Savannah River National Laboratory (SRNL) analyze the Concentration, Storage, and Transfer Facility (CSTF) samples from the following Tank Farm areas: the sump encasement, catch tank, drain cell, and waste tank annulus. In general, these CSTF samples will be analyzed on an infrequent basis and analyses will include detection for total beta/gamma, total alpha activities, density, free hydroxide, and pH measurements. This report presents characterization results for the H-Area diversion box 1 sump (HDB-1) January 2022 sample. The sample was slightly brown with a small amount of suspended fine particulates visually estimated to be less than 1% by volume. The results are measurements for total gamma, total alpha, total beta, density, free hydroxide, and pH.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Monte Carlo Simulation of Electron Interactions in an MeV-STEM for Thick Frozen Biological Sample Imaging

A variety of volume electron microscopy techniques have been developed to visualize thick biological samples. However, the resolution is limited by the sliced section thickness (>30–60 nm). To preserve biological samples in a hydrated state, cryo-focused ion beam scanning electron microscopy has been developed, providing nm resolutions. However, this method is time-consuming, requiring 15–20 h to image a 10 μm thick sample with an 8 nm slice thickness. There is a pressing need for a method that allows the rapid and efficient study of thick biological samples while maintaining nanoscale resolution. The remarkable ability of mega-electron-volt (MeV) electrons to penetrate thick biological samples, even exceeding 10 μm in thickness, while maintaining nanoscale resolution, positions MeV-STEM as a suitable microscopy tool for such applications. Our research delves into understanding the interactions between MeV electrons and frozen biological specimens through Monte Carlo simulations. Single elastic scattering, plural elastic scattering, single inelastic scattering, and plural inelastic scattering events have been simulated. The electron trajectories, the beam profile, and the intensity change of electrons in each category have been investigated. Additionally, the effects of the detector collection angle and the focal position of the electron beam were investigated. As electrons penetrated deeper into the specimen, single and plural elastic scattered electrons diminished, and plural inelastic scattered electrons became dominant, and the beam profile became wider. Even after 10 μm of the specimen, 42% of the MeV electrons were collected within 10 mrad. This confirms that MeV-STEM can be employed to study thick biological samples.

electron specimen interaction↗

Sensors and sensor systems for guidance and navigation II; Proceedings of the Meeting, Orlando, FL, Apr. 22, 23, 1992

Topics discussed in this volume include aircraft guidance and navigation, optics for visual guidance of aircraft, spacecraft and missile guidance and navigation, lidar and ladar systems, microdevices, gyroscopes, cockpit displays, and automotive displays. Papers are presented on optical processing for range and attitude determination, aircraft collision avoidance using a statistical decision theory, a scanning laser aircraft surveillance system for carrier flight operations, star sensor simulation for astroinertial guidance and navigation, autonomous millimeter-wave radar guidance systems, and a 1.32-micron long-range solid state imaging ladar. Attention is also given to a microfabricated magnetometer using Young's modulus changes in magnetoelastic materials, an integrated microgyroscope, a pulsed diode ring laser gyroscope, self-scanned polysilicon active-matrix liquid-crystal displays, the history and development of coated contrast enhancement filters for cockpit displays, and the effect of the display configuration on the attentional sampling performance.

Welch, Sharon S.↗

Water Based Phase Change Material Heat Exchanger Development

In a cyclical heat load environment such as low Lunar orbit, a spacecraft’s radiators are not sized to reject the full heat load requirement. Traditionally, a supplemental heat rejection device (SHReD) such as an evaporator or sublimator is used to act as a “topper” to meet the additional heat rejection demands. Utilizing a Phase Change Material (PCM) heat exchanger (HX) as a SHReD provides an attractive alternative to evaporators and sublimators as PCM HXs do not use a consumable, thereby leading to reduced launch mass and volume requirements. Studies conducted in this paper investigate utilizing water’s high latent heat of formation as a PCM, as opposed to traditional waxes, and corresponding complications surrounding freezing water in an enclosed volume. Work highlighted in this study is primarily visual and includes understanding ice formation, freeze front propagation, and the solidification process of water/ice. Various test coupons were constructed of copper to emulate the interstitial pin configuration (to aid in conduction) of the proposed water PCM HX design. Construction of a prototypic HX was also completed in which a flexible bladder material and interstitial pin configurations were tested. Additionally, a microgravity flight was conducted where three copper test articles were frozen continuously during microgravity and 2-g periods and individual water droplets were frozen during microgravity.

Hansen, Scott W.↗

Comparison of Magnetic Resonance Imaging and Computed Tomography for Breast Target Volume Delineation in Prone and Supine Positions

Purpose: To determine whether T2-weighted MRI improves seroma cavity (SC) and whole breast (WB) interobserver conformity for radiation therapy purposes, compared with the gold standard of CT, both in the prone and supine positions. Methods and Materials: Eleven observers (2 radiologists and 9 radiation oncologists) delineated SC and WB clinical target volumes (CTVs) on T2-weighted MRI and CT supine and prone scans (4 scans per patient) for 33 patient datasets. Individual observer's volumes were compared using the Dice similarity coefficient, volume overlap index, center of mass shift, and Hausdorff distances. An average cavity visualization score was also determined. Results: Imaging modality did not affect interobserver variation for WB CTVs. Prone WB CTVs were larger in volume and more conformal than supine CTVs (on both MRI and CT). Seroma cavity volumes were larger on CT than on MRI. Seroma cavity volumes proved to be comparable in interobserver conformity in both modalities (volume overlap index of 0.57 (95% Confidence Interval (CI) 0.54-0.60) for CT supine and 0.52 (95% CI 0.48-0.56) for MRI supine, 0.56 (95% CI 0.53-0.59) for CT prone and 0.55 (95% CI 0.51-0.59) for MRI prone); however, after registering modalities together the intermodality variation (Dice similarity coefficient of 0.41 (95% CI 0.36-0.46) for supine and 0.38 (0.34-0.42) for prone) was larger than the interobserver variability for SC, despite the location typically remaining constant. Conclusions: Magnetic resonance imaging interobserver variation was comparable to CT for the WB CTV and SC delineation, in both prone and supine positions. Although the cavity visualization score and interobserver concordance was not significantly higher for MRI than for CT, the SCs were smaller on MRI, potentially owing to clearer SC definition, especially on T2-weighted MR images.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CPU Volume Rendering of Adaptive Mesh Refinement Data

Adaptive Mesh Refinement (AMR) methods are widespread in scientific computing, and visualizing the resulting data with efficient and accurate rendering methods can be vital for enabling interactive data exploration. In this work, we detail a comprehensive solution for directly volume rendering block-structured (Berger-Colella) AMR data in the OSPRay interactive CPU ray tracing framework. In particular, we contribute a general method for representing and traversing AMR data using a kd-tree structure, and four different reconstruction options, one of which in particular (the basis function approach) is novel compared to existing methods. Here, we demonstrate our system on two types of block-structured AMR data and compressed scalar field data, and show how it can be easily used in existing production-ready applications through a prototypical integration in the widely used visualization program ParaView.

97 MATHEMATICS AND COMPUTING↗

High spatial resolution brain functional MRI using submillimeter balanced steady-state free precession acquisition

Purpose: One of the technical advantages of functional magnetic resonance imaging (fMRI) is its precise localization of changes from neuronal activities. While current practice of fMRI acquisition at voxel size around 3 × 3 × 3 mm{sup 3} achieves satisfactory results in studies of basic brain functions, higher spatial resolution is required in order to resolve finer cortical structures. This study investigated spatial resolution effects on brain fMRI experiments using balanced steady-state free precession (bSSFP) imaging with 0.37 mm{sup 3} voxel volume at 3.0 T. Methods: In fMRI experiments, full and unilateral visual field 5 Hz flashing checkerboard stimulations were given to healthy subjects. The bSSFP imaging experiments were performed at three different frequency offsets to widen the coverage, with functional activations in the primary visual cortex analyzed using the general linear model. Variations of the spatial resolution were achieved by removing outerk-space data components. Results: Results show that a reduction in voxel volume from 3.44 × 3.44 × 2 mm{sup 3} to 0.43 × 0.43 × 2 mm{sup 3} has resulted in an increase of the functional activation signals from (7.7 ± 1.7)% to (20.9 ± 2.0)% at 3.0 T, despite of the threefold SNR decreases in the original images, leading to nearly invariant functional contrast-to-noise ratios (fCNR) even at high spatial resolution. Activation signals aligning nicely with gray matter sulci at high spatial resolution would, on the other hand, have possibly been mistaken as noise at low spatial resolution. Conclusions: It is concluded that the bSSFP sequence is a plausible technique for fMRI investigations at submillimeter voxel widths without compromising fCNR. The reduction of partial volume averaging with nonactivated brain tissues to retain fCNR is uniquely suitable for high spatial resolution applications such as the resolving of columnar organization in the brain.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Visualization and Analysis of Multi-scale Land Surface Products via Giovanni Portals

Large volumes of MODIS land data products at multiple spatial resolutions have been integrated into the Giovanni online analysis system to support studies on land cover and land use changes,focused on the Northern Eurasia and Monsoon Asia regions through the LCLUC program. Giovanni (Goddard Interactive Online Visualization ANd aNalysis Infrastructure) is a Web-based application developed by the NASA Goddard Earth Sciences Data and Information Services Center (GES DISC), providing a simple and intuitive way to visualize, analyze, and access Earth science remotely-sensed and modeled data.Customized Giovanni Web portals (Giovanni-NEESPI andGiovanni-MAIRS) have been created to integrate land, atmospheric,cryospheric, and societal products, enabling researchers to do quick exploration and basic analyses of land surface changes, and their relationships to climate, at global and regional scales. This presentation shows a sample Giovanni portal page, lists selected data products in the system, and illustrates potential analyses with imagesand time-series at global and regional scales, focusing on climatology and anomaly analysis. More information is available at the GES DISCMAIRS data support project portal: http:disc.sci.gsfc.nasa.govmairs.

Shen, Suhung↗

Gyrokinetic Particle Simulation of Turbulent Transport in Burning Plasmas

In this project, we have developed techniques for visualizing large-scale time-varying multivariate particle and field data produced by the GPS_TTBP team. Our basic approach to particle data visualization is to provide the user with an intuitive interactive interface for exploring the data. We have designed a multivariate filtering interface for scientists to effortlessly isolate those particles of interest for revealing structures in densely packed particles as well as the temporal behaviors of selected particles. With such a visualization system, scientists on the GPS-TTBP project can validate known relationships and temporal trends, and possibly gain new insights in their simulations. We have tested the system using over several millions of particles on a single PC. We will also need to address the scalability of the system to handle billions of particles using a cluster of PCs. To visualize the field data, we choose to use direct volume rendering. Because the data provided by PPPL is on a curvilinear mesh, several processing steps have to be taken. The mesh is curvilinear in nature, following the shape of a deformed torus. Additionally, in order to properly interpolate between the given slices we cannot use simple linear interpolation in Cartesian space but instead have to interpolate along the magnetic field lines given to us by the scientists. With these limitations, building a system that can provide an accurate visualization of the dataset is quite a challenge to overcome. In the end we use a combination of deformation methods such as deformation textures in order to fit a normal torus into their deformed torus, allowing us to store the data in toroidal coordinates in order to take advantage of modern GPUs to perform the interpolation along the field lines for us. The resulting new rendering capability produces visualizations at a quality and detail level previously not available to the scientists at the PPPL. In summary, in this project we have successfully created new capabilities for the scientists to visualize their 3D data at higher accuracy and quality, enhancing their ability to evaluate the simulations and understand the modeled phenomena.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Real-Time Visualization of Network Behaviors for Situational Awareness

Plentiful, complex, and dynamic data make understanding the state of an enterprise network difficult. Although visualization can help analysts understand baseline behaviors in network traffic and identify off-normal events, visual analysis systems often do not scale well to operational data volumes (in the hundreds of millions to billions of transactions per day) nor to analysis of emergent trends in real-time data. We present a system that combines multiple, complementary visualization techniques coupled with in-stream analytics, behavioral modeling of network actors, and a high-throughput processing platform called MeDICi. This system provides situational understanding of real-time network activity to help analysts take proactive response steps. We have developed these techniques using requirements gathered from the government users for which the tools are being developed. By linking multiple visualization tools to a streaming analytic pipeline, and designing each tool to support a particular kind of analysis (from high-level awareness to detailed investigation), analysts can understand the behavior of a network across multiple levels of abstraction.

97 MATHEMATICS AND COMPUTING↗

Exploring Time-Varying Multivariate Volume Data Using Matrix of Isosurface Similarity Maps

We present a novel visual representation and interface named the matrix of isosurface similarity maps (MISM) for effective exploration of large time-varying multivariate volumetric data sets. MISM synthesizes three types of similarity maps (i.e., self, temporal, and variable similarity maps) to capture the essential relationships among isosurfaces of different variables and time steps. Additionally, it serves as the main visual mapping and navigation tool for examining the vast number of isosurfaces and exploring the underlying time-varying multivariate data set. We present temporal clustering, variable grouping, and interactive filtering to reduce the huge exploration space of MISM. In conjunction with the isovalue and isosurface views, MISM allows users to identify important isosurfaces or isosurface pairs and compare them over space, time, and value range. More importantly, we introduce path recommendation that suggests, animates, and compares traversal paths for effectively exploring MISM under varied criteria and at different levels-of-detail. A silhouette-based method is applied to render multiple surfaces of interest in a visually succinct manner. We demonstrate the effectiveness of our approach with case studies of several time-varying multivariate data sets and an ensemble data set, and evaluate our work with two domain experts.

97 MATHEMATICS AND COMPUTING↗