Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “visualizing data variation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

240 records · Page 14

AGR-1 Compact 4-1-1 Post-Irradiation Examination Results

Destructive post-irradiation examination was performed on AGR-1 fuel Compact 4-1-1, which was irradiated to a final compact-average burnup of 19.4% FIMA (fissions per initial metal atom) and a time-average, volume-average temperature of 1072°C. The analysis of this compact focused on characterizing the extent of fission product release from the particles and examining particles to determine the condition of the kernels and coating layers. The work included deconsolidation of the compact and leach-burn-leach analysis, visual inspection and gamma counting of individual particles, metallurgical preparation of selected particles, and examination of particle cross-sections with optical microscopy, electron microscopy, and elemental analysis. Deconsolidation-leach-burn-leach (DLBL) analysis revealed no particles with failed TRISO or failed SiC layers (as indicated by very low uranium inventory in all of the leach solutions). The total fractions of the predicted compact inventories of fission products Ce-144, Cs-134, Cs-137, and Sr-90 that were present in the compact outside of the SiC layers were <2×10 -6 , based on DLBL data. The Ag-110m fraction in the compact outside the SiC layers was 3.3×10 -2 , indicating appreciable release of silver through the intact coatings and subsequent retention in the OPyC layers or matrix. The Eu-154 fraction was 2.4×10 -4 , which is equivalent to the inventory in one average particle, and indicates a small but measurable level of release from the intact coatings. Gamma counting of 61 individual particles indicated no particles with anomalously low fission product retention. The average ratio of measured inventory to calculated inventory was close to a value of 1.0 for several fission product isotopes (Ce-144, Cs-134, and Cs-137), indicating good retention and reasonably good agreement with the predicted inventories. Measured-to-calculated (M/C) activity ratios for fission products Eu-154, Eu-155, Ru-106, Sb-125, and Zr-95 were significantly less than 1.0. However, as no significant release of these fission products from compacts was noted during previous analysis of the AGR-1 capsule components, the low M/C ratios are most likely an indication of a bias in the inventories predicted by physics simulations of the AGR-1 experiment. The distribution of Ag-110m M/C ratios was centered on a value of 1.02 and was fairly broad (standard deviation of 0.18, with values as high as 1.42 and as low as 0.68). Based on all data gathered to date, it is believed that silver retention in the particles was on average relatively high, but that the broad distribution in values among the particles represents significant variation in the inventory of Ag-110m generated in the particles. Ceramographic analysis of particle cross-sections revealed many of the characteristic microstructures often observed in irradiated AGR-1 particles from other fuel compacts. Palladium-rich fission product clusters were observed in the IPyC and SiC layers near the IPyC-SiC interface of three Compact 4-1-1 particle cross-sections. In spite of the presence of fission product clusters in the SiC layer, no significant corrosion or degradation of the layer was observed in any of the particles examined.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Reliability Assessment of Remote Visual Examination

Remote visual testing (RVT) is a commonly used nondestructive examination method for inservice inspection (ISI) of reactor internals to detect cracking and gross component failures. Despite widespread use, the detection reliability of RVT and the factors that impact overall RVT performance have been unresolved issues. This report describes the results from an assessment sponsored by the U.S. Nuclear Regulatory Commission and conducted by the Pacific Northwest National Laboratory, in cooperation with the Electric Power Research Institute, for evaluating the reliability of RVT methods currently being used for [reactor] in-vessel visual inspection. The goal was to assess the performance of commercially applied RVT examination procedures implemented by qualified personnel, as well as to identify and qualitatively assess enhancements to examination procedures for detecting flaws in test specimens. The assessment was performed over three phases of research, with the results of the first phase used to identify key controllable parameters impacting RVT performance and to design the next two phases (round-robin testing). Participants in the round-robin tests included teams of inspectors from commercial nuclear power ISI vendors. Participants were asked to determine if a specimen contained a crack and its approximate location, orientation, and length. The detection and location information were used to compute estimates of the probability of detection and false call probability for various scenarios such as the placement and orientation of the flaw on the specimen, team-to-team variations in detection performance, and effects of secondary review on RVT detection. Results showed that crack opening displacement (COD) is the dominant factor in the reliability of crack detection using commercially applied RVT procedures, with crack length being weakly correlated with detection probability. The implication is that RVT detection is likely heavily dependent on the contrast produced by the crack opening, with crack detection becoming less reliable as the COD decreases. Further, the results indicated RVT will be challenged when cracks are located in the vicinity of surface features such as scratches or weld ripples, or close to the edge of welds where shadowing and/or the presence of weld undercuts may complicate the ability to detect the crack. The assessment also reinforced earlier findings on the importance of lighting in flaw detection and appeared to align with other studies that find improved reliability when using multiple inspectors or analysts. Finally, the results pointed to the importance of practice with specimens that mimic conditions likely to be found in the field. Based on the findings and limitations of the assessment, a number of recommendations are made regarding best practices for improving the reliability of RVT in a field setting and for addressing remaining informational gaps. This report describes the design and noted limitations of the three phases of research, the analysis methodology for each phase, and the results of the research. The results of this assessment provide a benchmark set of data on the reliability of RVT for detecting cracking, assuming the implementation of field-like inspection procedures. The likely impact of several uncontrolled factors on RVT detection performance are discussed, and recommendations regarding the use of these results to assess field performance are provided. Finally, recent advances in RVT technology are briefly discussed and point to the potential need for continued research to evaluate the capability and effectiveness of the technique as improvements are implemented.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Fast compressed sensing-based CBCT reconstruction using Barzilai-Borwein formulation for application to on-line IGRT

Purpose: Compressed sensing theory has enabled an accurate, low-dose cone-beam computed tomography (CBCT) reconstruction using a minimal number of noisy projections. However, the reconstruction time remains a significant challenge for practical implementation in the clinic. In this work, we propose a novel gradient projection algorithm, based on the Gradient-Projection-Barzilai-Borwein formulation (GP-BB), that handles the total variation (TV)-norm regularization-based least squares problem for the CBCT reconstruction in a highly efficient manner, with speed acceptable for routine use in the clinic. Methods: CBCT is reconstructed by minimizing an energy function consisting of a data fidelity term and a TV-norm regularization term. Both terms are simultaneously minimized by calculating the gradient projection of the energy function with the step size determined using an approximate Hessian calculation at each iteration, based on the Barzilai-Borwein formulation. To speed up the process, a multiresolution optimization is used. In addition, the entire algorithm was designed to run with a single graphics processing unit (GPU) card. To evaluate the performance, the Shepp-Logan numerical phantom, the CatPhan 600 physical phantom, and a clinically-treated head-and-neck patient were acquired from the TrueBeam system (Varian Medical Systems, Palo Alto, CA). For each scan, in total, 364 projections were acquired in a 200 deg. rotation. The imager has 1024 x 768 pixels with 0.388 x 0.388-mm resolution. This was down-sampled to 512 x 384 pixels with 0.776 x 0.776-mm resolution for reconstruction. Evenly spaced angles were subsampled and used for varying the number of projections for the image reconstruction. To assess the performance of our GP-BB algorithm, we have implemented and compared with three compressed sensing-type algorithms, the two of which are popular and published (forward-backward splitting techniques), and the other one with a basic line-search technique. In addition, the conventional Feldkamp-Davis-Kress (FDK) reconstruction of the clinical patient data is compared as well. Results: In comparison with the other compressed sensing-type algorithms, our algorithm showed convergence in {<=}30 iterations whereas other published algorithms need at least 50 iterations in order to reconstruct the Shepp-Logan phantom image. With the CatPhan phantom, the GP-BB algorithm achieved a clinically-reasonable image with 40 projections in 12 iterations, in less than 12.6 s. This is at least an order of magnitude faster in reconstruction time compared with the most recent reports utilizing GPU technology given the same input projections. For the head-and-neck clinical scan, clinically-reasonable images were obtained from 120 projections in 34-78 s converging in 12-30 iterations. In this reconstruction range (i.e., 120 projections) the image quality is visually similar to or better than the conventional FDK reconstructed images using 364 projections. This represents a dose reduction of nearly 67% (120/364 projections) while maintaining a reasonable speed in clinical implementation. Conclusions: In this paper, we proposed a novel, fast, low-dose CBCT reconstruction algorithm using the Barzilai-Borwein step-size calculation. A clinically viable head-and-neck image can be obtained within {approx}34-78 s while simultaneously cutting the dose by approximately 67%. This makes our GP-BB algorithm potentially useful in an on-line image-guided radiation therapy (IGRT).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The crystal structure of Hf{sub 1.5+{delta}}Nb{sub 1.5-{delta}}As and structure-composition relations in the section Hf{sub 3}As-Nb{sub 3}As

The title compound Hf{sub 1.5+{delta}}Nb{sub 1.5-{delta}}As was characterized by means of single crystal X-ray diffraction. It represents a new structure type of intermetallic compounds (space group Pnma; lattice parameters a=7.142(2) A, b=3.583(2) A, c=11.640(2) A) and shows a small homogeneity range corresponding to (0.1<delta<0.25) at 1400 deg. C. The crystal structure may be visualized by a combination of As-centred trigonal prisms of the metal atoms and bcc-like fragments formed by metal atoms. Structural relations with various binary arsenides are discussed. The structure of Hf{sub 1.5+{delta}}Nb{sub 1.5-{delta}}As shows significant preferred site occupation of Hf and Nb at the three independent metal positions (differential fractional site occupancy). Structure-composition relations in the section Hf{sub 3}As-Nb{sub 3}As which also contains the new phase Hf{sub 2+{delta}}Nb{sub 1-{delta}}As with Ti{sub 3}P-type structure (space group P4{sub 2}/n) are discussed. Ground state energies of various ordered compounds with Hf{sub 1.5+{delta}}Nb{sub 1.5-{delta}}As-, Ti{sub 3}P- and Ta{sub 3}As-type structures were calculated from ab initio density functional theory. These energies were used for thermodynamic calculations employing the compound energy formalism (CEF) with the aim to model the experimentally observed site fraction data for both ternary compounds as well as Gibbs energies at the temperature of equilibration (1400 deg. C). - Graphical abstract: Hf{sub 1.5+{delta}}Nb{sub 1.5-{delta}}As with a new structure type (space group Pnma; lattice parameters a=7.142(2) A, b=3.583(2) A, c=11.640(2)A) was synthesized. Phase relations, energies and partial ordering in the section Hf{sub 3}As-Nb{sub 3}As were studied by first principle DFT calculations and thermodynamic modelling.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

EXCHANGE Campaign 1: A Community-Driven Baseline Characterization of Soils, Sediments, and Water Across Coastal Gradients

The EXploration of Coastal Hydrobiogeochemistry Across a Network of Gradients and Experiments (EXCHANGE) program is a consortium of scientists working together to improve our understanding of how the two-way exchange of water between estuaries or large lake lacustuaries and the terrestrial landscape influence the state and function of ecosystems across the coastal interface. EXCHANGE Campaign 1 (EC1) focuses on the spatial variation in biogeochemical structure and function at the coastal terrestrial-aquatic interface (TAI). In the Fall of 2021, the EXCHANGE Consortium gathered samples from 52 TAIs. Samples collected from EC1 were analyzed for bulk geochemical parameters, bulk physicochemical parameters, organic matter characteristics, and redox-sensitive elements.Please download ec1_README.pdf for a complete list of available data in each .zip folder, package version history, and detailed information about the project. This README will serve as the central place for EC1 Data Package updates. Experimental setup and v1 methods are documented in Myers-Pigg and Pennington et al., 2023 (https://doi.org/10.1038/s41597-023-02548-7).EC1 Data Package Structure:ec1_README.pdfec1_methods.pdfec1_metadata_v3.zip...ec1_dd.csv...ec1_flmd.csv...ec1_sample_catalog.csv...ec1_metadata_kitlevel.csv...ec1_metadata_collectionlevel.csv...ec1_data_collectionlevel.csv...ec1_igsn_metadata.csvec1_soil_v3.zipec1_sediment_v3.zipec1_water_v3.zipec1_processingscripts_v3.zipThis data package is on v3 and was originally published May 2023 (v1). Subsequent updates will be published here with new version numbers. Please see the Change History section in ec1_README.pdf for detailed changes.---Acknowledging EXCHANGE: General Support and Data Product UseWe ask that users of EXCHANGE data add the following acknowledgement when publishing data in scholarly articles and data repositories:"This research is based on work supported by COMPASS-FME, a multi-institutional project supported by the U.S. Department of Energy, Office of Science, Biological and Environmental Research as part of the Environmental System Science Program."

54 ENVIRONMENTAL SCIENCES↗

Particle-image Velocimetry Sensitivity through Automatic Differentiation

A commonly encountered difficulty in modern experimental fluid dynamics experiments is the need for full-flow visualization and measurement; traditional techniques such as hot-wire probes and laser Doppler velocimetry cannot provide such information without difficult scanning procedures. Particle-image velocimetry (PIV) is a measurement technique which can overcome this spatial limitation to provide real-time three-dimensional fluid velocity vectors for an entire plane within the flow, as opposed to a single point that is provided by other measurement techniques. To accomplish this, a PIV system seeds the fluid flow with tracer particles; these must have nearly the same density as that of the fluid and a high drag coefficient to ensure that they follow the fluid flow without deviation. A laser is sent through optics to expand its beam into a sheet which illuminates the plane of interest in the fluid. The particles reflect more light than the fluid, and their image is recorded using a high speed camera. Due to limitations in bandwidth, video cannot be taken fast enough to be useful, and instead pairs of images are captured with a known separation in time. The illuminated particles will move between the two images taken by the camera, and their relative motion can be used to compute the fluid velocity at that point. When a single camera is used, only two-dimensional velocity vectors can be computed, but with the addition of another camera this can be improved to full three-dimensional vectors. The flow's time evolution can be measured by taking series of image pairs and processing each pair to get the velocity field at the time between each image pair. Only the two-dimensional version will be considered in this work. To compute the velocity vectors of the flow, the images are broken up into interrogation regions, usually in a uniform grid. In the most basic PIV algorithm, corresponding regions in the image pairs are cross-correlated to compute the most likely displacement from one image to the next. This is used since the cross correlation will achieve a maximum value when the two interrogation regions line up the best. The location of the peak in the correlation map and scaling information for the optical setup is used to compute the particle displacement from one image to the next. This process is similar to holding two semi-transparent images and moving one until they match as well as possible. Sub-pixel displacements between images can be obtained by fitting a Gaussian function to the correlation peak. Knowing the displacement vector for each set of interrogation regions in the image pair, it is a simple matter to divide by the time gap between the two images to compute the fluid velocity at the point in time and space. Since there are many interrogation regions in each image pair, the velocity field for a sheet is sampled according to the arrangement of the interrogation regions. The sensitivity of the final computed vector to the input images is difficult to compute, and has led most considerations of uncertainty in the PIV field to apply Monte Carlo methods and correlations to quantify the systematic and random errors which result from application of various PIV algorithms. In this work, automatic differentiation (AD) has been used to trace the dependence of velocity vectors computed using the correlation-peak PIV algorithm back to the input values given to an artificial image generator. These initial results form the foundation for continued work in the application of AD to algorithms in PIV. They demonstrate that AD methods can be successfully applied to PIV algorithms without undue complexity. The derivatives of each individual vector with regard to the coefficients of the velocity field used to create the artificial images can be computed and the statistics of them considered collectively, or correlated between each other to quantify the effectiveness of a PIV algorithm. With the initial implementation complete, adding extra algorithms is relatively simple and considerable data can be generated for analysis. It is hoped that application of these methods can lead to improved PIV algorithms which demonstrate better sensitivity to small variations in particle displacement. While these methods can be used as an analysis tool for refinement of new algorithms, computation of actual resultant vector sensitivities to input images' individual pixels is the next logical step of this work. Such information will be analyzed with experimental data to produce a better understanding of how output vectors' uncertainty relates to the actual image pairs, and lead to automatic bad vector removal. (authors)

42 ENGINEERING↗