Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “vertical axis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Effects of experimental hypogravity on peroxidase and cell wall constituents in the dwarf marigold

Dwarf Marigolds grown from seed under experimental hypogravity are modified in lignin content, hemicellulose composition, and peroxidase activity. The two conditions used, clinostats and flotation, induced changes differing in magnitude but qualitatively similar. Most responses on clinostats required corrections for vertical axis rotational effects, thus limiting the value of these instruments in free-fall simulation. These findings extend earlier observations suggesting that increased peroxidase and decreased lignin are characteristic of growth under experimental hypogravity.

Cell Wall/metabolism↗

Transient Torque Method: A Fast and Nonintrusive Technique to Simultaneously Determine Viscosity and Electrical Conductivity of Semiconducting and Metallic Melts

A transient torque method was developed to rapidly and simultaneously determine the viscosity and electrical conductivity of liquid metals and molten semiconductors. The experimental setup of the transient torque method is similar to that of the oscillation cup method. The melt sample is sealed inside a fused silica ampoule, and the ampoule is suspended by a long quartz fiber to form a torsional oscillation system. A rotating magnetic field is used to induce a rotating flow in the conductive melt, which causes the ampoule to rotate around its vertical axis. A sensitive angular detector is used to measure the deflection angle of the ampoule. Based on the transient behavior of the deflection angle as the rotating magnetic field is applied, the electrical conductivity and viscosity of the melt can be obtained simultaneously by numerically fitting the data to a set of governing equations. The transient torque viscometer was applied successfully to measure the viscosity and electrical conductivity of high purity mercury at 53.4 C. The results were in excellent agreement with published data. The method is nonintrusive; capable of rapid measurement of the viscosity of toxic, high vapor pressure melts at elevated temperatures. In addition, the transient torque viscometer can also be operated as an oscillation cup viscometer to measure just the viscosity of the melt or as a rotating magnetic field method to determine the electrical conductivity of a melt or a solid if desired.

Li, C.↗

Human heart rate variability relation is unchanged during motion sickness

In a study of 18 human subjects, we applied a new technique, estimation of the transfer function between instantaneous lung volume (ILV) and instantaneous heart rate (HR), to assess autonomic activity during motion sickness. Two control recordings of ILV and electrocardiogram (ECG) were made prior to the development of motion sickness. During the first, subjects were seated motionless, and during the second they were seated rotating sinusoidally about an earth vertical axis. Subjects then wore prism goggles that reverse the left-right visual field and performed manual tasks until they developed moderate motion sickness. Finally, ILV and ECG were recorded while subjects maintained a relatively constant level of sickness by intermittent eye closure during rotation with the goggles. Based on analyses of ILV to HR transfer functions from the three conditions, we were unable to demonstrate a change in autonomic control of heart rate due to rotation alone or due to motion sickness. These findings do not support the notion that moderate motion sickness is manifested as a generalized autonomic response.

NASA Discipline Neuroscience↗

Interaction of semicircular canal stimulation with carotid baroreceptor reflex control of heart rate

The carotid-cardiac baroreflex contributes to the prediction of orthostatic tolerance; experimental attenuation of the reflex response leads to orthostatic hypotension in humans and animals. Anecdotal observations indicate that rotational head movements about the vertical axis of the body can also induce orthostatic bradycardia and hypotension through increased parasympathetic activity. We therefore measured the chronotropic response to carotid baroreceptor stimulation in 12 men during varying conditions of vestibulo-oculomotor stimulation to test the hypothesis that stimulation of the semicircular canals associated with head movements in the yaw plane inhibits cardioacceleration through a vagally mediated baroreflex. Carotid-cardiac baroreflex response was assessed by plotting R-R intervals (ms) at each of 8 neck pressure steps with their respective carotid distending pressures (mmHg). Calculated baroreflex gain (maximal slope of the stimulus-response relationship) was measured under 4 experimental conditions: 1) sinusoidal whole-body yaw rotation of the subject in the dark without visual fixation (combined vestibular-oculomotor stimulation); 2) yaw oscillation of the subject while tracking a small head-fixed light moving with the subject (vestibular stimulation without eye movements); 3) subject stationary while fixating on a small light oscillating in yaw at the same frequency, peak acceleration, and velocity as the chair (eye movements without vestibular stimulation); and 4) subject stationary in the dark (no eye or head motion). Head motion alone and with eye movement reduced baseline baroreflex responsiveness to the same stimulus by 30%. Inhibition of cardioacceleration during rotational head movements may have significant impact on functional performance in aerospace environments, particularly in high-performance aircraft pilots during high angular acceleration in aerial combat maneuvers or in astronauts upon return from spaceflight who already have attenuated baroreflex functions.

Review, Tutorial↗

Spatial orientation of semicircular canals and afferent sensitivity vectors in pigeons

Rotational head motion in vertebrates is detected by the semicircular canal system, whose innervating primary afferent fibers carry information about movement in specific head planes. The semicircular canals have been qualitatively examined over a number of years, and the canal planes have been quantitatively characterized in several animal species. The present study first determined the geometric relationship between individual semicircular canals and between the canals and the stereotactic head planes in pigeons. Stereotactic measurements of multiple points along the circumference of the bony canals were taken, and the measured points fitted with a three-dimensional planar surface. Direction normals to the plane's surface were calculated and used to define angles between semicircular canal pairs. Because of the unusual shape of the anterior semicircular canals in pigeons, two planes, a major and a minor, were fitted to the canal's course. Calculated angle values for all canals indicated that the horizontal and posterior semicircular canals are nearly orthogonal, but the anterior canals have substantial deviations from orthogonality with other canal planes. Next, the responses of the afferent fibers that innervate each of the semicircular canals to 0.5 Hz sinusoidal rotation about an earth-vertical axis were obtained. The head orientation relative to the rotation axis was systematically varied so that directions of maximum sensitivity for each canal afferent could be determined. These sensitivity vectors were then compared with the canal plane direction normals. The afferents that innervated specific semicircular canals formed homogeneous clusters of sensitivity vectors in different head planes. The horizontal and posterior afferents had average sensitivity vectors that were largely co-incident with the innervated canal plane direction normals. Anterior canal afferents, however, appeared to synthesize contributions from the major and minor plane components of the bony canal structure to produce a resultant sensitivity vector that was positioned between the canal planes. Calculated angles between the average canal afferent sensitivity vectors revealed that direction orthogonality is preserved at the afferent signal level, even though deviations from canal plane orthogonality exist.

NASA Discipline Neuroscience↗

Habituation and adaptation of the vestibuloocular reflex: a model of differential control by the vestibulocerebellum

We habituated the dominant time constant of the horizontal vestibuloocular reflex (VOR) of rhesus and cynomolgus monkeys by repeated testing with steps of velocity about a vertical axis and adapted the gain of the VOR by altering visual input with magnifying and reducing lenses. After baseline values were established, the nodulus and ventral uvula of the vestibulocerebellum were ablated in two monkeys, and the effects of nodulouvulectomy and flocculectomy on VOR gain adaptation and habituation were compared. The VOR time constant decreased with repeated testing, rapidly at first and more slowly thereafter. The gain of the VOR was unaffected. Massed trials were more effective than distributed trials in producing habituation. Regardless of the schedule of testing, the VOR time constant never fell below the time constant of the semicircular canals (approximately 5 s). This finding indicates that only the slow component of the vestibular response, the component produced by velocity storage, was habituated. In agreement with this, the time constant of optokinetic after-nystagmus (OKAN) was habituated concurrently with the VOR. Average values for VOR habituation were obtained on a per session basis for six animals. The VOR gain was adapted by natural head movements in partially habituated monkeys while they wore x 2.2 magnifying or x 0.5 reducing lenses. Adaptation occurred rapidly and reached about +/- 30%, similar to values obtained using forced rotation. VOR gain adaptation did not cause additional habituation of the time constant. When the VOR gain was reduced in animals with a long VOR time constant, there were overshoots in eye velocity that peaked at about 6-8 s after the onset or end of constant-velocity rotation. These overshoots occurred at times when the velocity storage integrator would have been maximally activated by semicircular canal input. Since the activity generated in the canals is not altered by visual adaptation, this finding indicates that the gain element that controls rapid changes in eye velocity in the VOR is separate from that which couples afferent input to velocity storage. Nodulouvulectomy caused a prompt and permanent loss of habituation, returning VOR time constants to initial values. VOR gain adaptation, which is lost after flocculectomy, was unaffected by nodulouvulectomy. Flocculectomy did not alter habituation of the VOR or of OKAN. Using a simplified model of the VOR, the decrease in the duration of vestibular nystagmus due to habituation was related to a decrement in the dominant time constant of the velocity storage integrator (1/h0).(ABSTRACT TRUNCATED AT 400 WORDS).

NASA Discipline Neuroscience↗

Multiwavelength Pyrometer Developed for Use at Elevated Temperatures in Aerospace Applications

Researchers at the NASA Glenn Research Center have developed a unique multiwavelength pyrometer for aerospace applications. It has been shown to be a useful and versatile instrument for measuring the surface temperatures of ceramic zirconia thermal barrier coatings (TBCs) and alumina, even when their emissivity is unknown. The introduction of fiber optics into the pyrometer has greatly increased the ease of using this instrument. Direct comparison of measurements obtained using the pyrometer and thin film thermocouples on a sample provided independent verification of pyrometry temperature measurement. Application of the pyrometer has also included simultaneous surface and bulk temperature measurement in a transparent material, the measurement of combustion gas temperatures in the flames of an atmospheric burner, the measurement of the temperature distribution appearing on a large surface from the recording of just a single radiation spectrum emitted from this nonuniform temperature surface, and the measurement of some optical properties for special aeronautical materials-such as nanostructured layers. The multiwavelength pyrometer temperature is obtained from a radiation spectrum recorded over a broad wavelength region by transforming it into a straight line segment(s) in part or all of the spectral region. The intercept of the line segment(s) with the vertical axis at zero wavelength gives the inverse of the temperature. In a two-color pyrometer, the two data points are also amenable to this analysis to determine the unknown temperature. Implicit in a two-color pyrometer is the assumption of wavelength-independent emissivity. Its two (and minimum) pieces of data are sufficient to determine this straight line. However, a multiwavelength pyrometer not only has improved accuracy but also confirms that the wavelength-independent emissivity assumption is valid when a multitude of data points are shown to lie on a simple straight line.

Ng, Daniel L.↗

On the Antenna Pattern of Orbitting Interferometer

We consider the response of an interferometer moving with respect to a fixed reference frame, and derive a simple expression for the beam-pattern factors and the polarization-averaged antenna power pattern...Then, we consider a class of motions where the detector's plane is constrained to move on the surface of a cone of constant aperture; at the same time, the two arms are rotating around a vertical axis...In addition, we consider the case of an Earth-based interferometer...Finally, we discuss LISA's response to circularly polarized sinusoidal waves, coming from a few known binary systems in our Galaxy.

interferometer interferometry antenna motions LISA↗

(abstract) Microwave Induced Combustion Synthesis of Ceramic and Ceramic-Metal Composites

We have used microwaves to induce self-propagating high temperature synthesis (SHS) in the reaction 3TiO(sub 2)+3C+(4+x)Al ---> 3TiC+2Al(sub 2)O(sub 3)+xAl. The SHS process was studied for x = 0 and 4, with and without the application of uniaxial pressure. A TE102 microwave cavity mode internally ignited the samples using less than 50 watts. The resultant microstructure of the microwave processed samples were compared to SHS products obtained using a conventional hot wire ignition technique. Uniaxial stresses along the vertical axis of approximately 1400 and 200 psi were applied simultaneously as the SHS reactions were initiated in some of the conventional and microwave processed samples, respectively. SEM photomicrographs will be presented that show the different microstructural features of the products using the microwave and hot wire techniques.

ceramic microwave ceramic-metal composites microwa↗

Pharmacotherapeutics of Intranasal Scopolamine: FDA Regulations and Procedures for Clinical Applications

Space Motion Sickness (SMS) is commonly experienced by astronauts and often requires treatment with medications during the early flight days of a space mission. Bioavailability of oral (PO) SMS medications is often low and highly variable; additionally, physiological changes in a microgravity environment exacerbate variability and decrease bioavailability. These factors prompted NASA to develop an intranasal dosage form of scopolamine (INSCOP) suitable for the treatment of SMS. However, to assure safety and efficacy of treatment in space, NASA physicians prescribe commercially available pharmaceutical products only. Development of a pharmaceutical preparation for clinical use must follow distinct clinical phases of testing, phase I through IV to be exact, before it can be approved by the FDA for approval for clinical use. After a physician sponsored Investigative New Drug (IND) application was approved by the FDA, a phase I clinical trial of INSCOP formulation was completed in normal human subjects and results published. The current project includes three phase II clinical protocols for the assessment of pharmacokinetics and pharmacodynamics (PK/PD), efficacy, and safety of INSCOP. Three clinical protocols that were submitted to FDA to accomplish the project objectives: 1) 002-A, a FDA Phase II dose ranging study with four dose levels between 0.1 and 0.4 mg in 12 subjects to assess PK/PD, 2) 002-B, a phase II clinical efficacy study in eighteen healthy subjects to compare efficacy of 0.2 (low dose) and 0.4 mg (high dose) INSCOP for prophylactic treatment of motion-induces (off-axis vertical rotation) symptoms, and (3) 002-C, a phase II clinical study with twelve subjects to determine bioavailability and pharmacodynamics of two doses (0.2 and 0.4 mg) of INSCOP in simulated microgravity, antiorthostatic bedrest. All regulatory procedures were competed that include certification for Good laboratory Procedures by Theradex , clinical documentation, personnel training, selection of clinical research operations contractor, data capturing and management, and annual reporting of results to FDA were successfully completed. Protocol 002-A was completed and sample and data analysis is currently in progress. Protocol 002-B is currently in progress at Dartmouth Hitchcock Medical Center and Protocol 002-C has been submitted to the FDA and will be implemented at the same contractor site as 002-A. An annual report was filed as required by FDA on the results of Protocol 002-A. Once all the three Phase II protocols are completed, a New Drug Administration application will be filed with FDA for Phase III clinical assessment and approval for marketing of the formulation. A commercial vendor will be identified for this phase. This is critical for making this available for treatment of SMS in astronauts and military personnel on duty. Once approved by FDA, INSCOP can be also used by civilian population for motion sickness associated with recreational travel and other ailments that require treatment with anticholinergic drugs.

Das, H.↗

Neurovestibular and Sensorimotor Studies in Space and Earth Benefits

This review summarizes what has been learned from studies of human neurovestibular system in weightless conditions, including balance and locomotion, gaze control, vestibular-autonomic function and spatial orientation, and gives some examples of the potential Earth benefits of this research. Results show that when astronauts and cosmonauts return from space flight, both the peripheral and central neural processes are physiologically and functionally altered. There are clear distinctions between the virtually immediate adaptive compensations to weightlessness and those that require longer periods of time to adapt. However, little is known to date about the adaptation of sensory-motor functions to long-duration space missions in weightlessness and to the transitions between various reduced gravitational levels, such as on the Moon and Mars. Results from neurovestibular research in space have substantially enhanced our understanding of the mechanisms and characteristics of postural, gaze, and spatial orientation deficits, analogous to clinical cases of labyrinthine-defective function. Also, space neurosciences research has participated in the development and application of significant new technologies, such as video recording and processing of three-dimensional eye movements and posture, hardware for the unencumbered measurement of head and body movement, and procedures for investigating otolith function on Earth. In particular, devices such as centrifugation or off-vertical axis rotation could enhance clinical neurological testing because it provides linear acceleration which specifically stimulates the otolith organs in a frequency range close to natural head and body movement.

Clement, Gilles↗

Exploring and Visualizing A-Train Instrument Data

The succession of US and international satellites that follow each other in close succession, known as the A-Train, affords an opportunity to atmospheric researchers that no single platform could provide: Increasing the number of observations at any given geographic location.. . a more complete "virtual science platform". However, vertically and horizontally, co-registering and regridding datasets from independently developed missions, Aqua, Calipso, Cloudsat, Parasol, and Aura, so that they can be inter-compared can be daunting to some, and may be repeated by many. Scientists will individually spend much of their time and resources acquiring A-Train datasets of interest residing at various locations, developing algorithms to match up and graph datasets along the A-Train track, and search through large amounts of data for areas and/or phenomena of interest. The aggregate amount of effort that can be expended on repeating pre-science tasks could climb into the tens of millions of dollars. The goal of the A-Train Data Depot (ATDD) is to enable free movement of remotely located A-Train data so that they are combined to create a consolidated vertical view of the Earth's Atmosphere along the A-Train tracks. The innovative approach of analyzing and visualizing atmospheric profiles along the platforms track (i.e., time) is accomplished by through the ATDDs Giovanni data analysis and visualization tool. Giovanni brings together data from Aqua (MODIS, AIRS, AMSR-E), Cloudsat (cloud profiling radar) and Calipso (CALIOP, IIR), as well as the Aura (OMI, MLS, HIRDLS, TES) to create a consolidated vertical view of the Earth's Atmosphere along the A-Train tracks. This easy to learn and use exploration tool will allow users to create vertical profiles of any desired A-Train dataset, for any given time of choice. This presentation shows the power of Giovanni by describing and illustrating how this tool facilitates and aids A-Train science and research. A web based display system Giovanni provides users with the capability of creating co-located profile images of temperature and humidity data from the MODIS, MLS and AIRS instruments for a user specified time and spatial area. In addition, Cloud and Aerosol profiles may also be displayed for the Cloudsat and Caliop instruments. The ability to modify horizontal and vertical axis range, data range and dynamic color range is also provided. Two dimensional strip plots of MODIS, AIRS, OM1 and POLDER parameters, co-located along the Cloudsat reference track, can also be plotted along with the Cloudsat cloud profiling data. Center swath pixels for the same parameters can also be shown as line plots overlaying the Cloudsat or Calipso profile images. Images and subsetted data produced in each analysis run may be downloaded. Users truly can explore and discover data specific to their needs prior to ever transferring data to their analysis tools.

Kempler, S.↗

Effects of Frequency and Motion Paradigm on Perception of Tilt and Translation During Periodic Linear Acceleration

Previous studies have demonstrated an effect of frequency on the gain of tilt and translation perception. Results from different motion paradigms are often combined to extend the stimulus frequency range. For example, Off-Vertical Axis Rotation (OVAR) and Variable Radius Centrifugation (VRC) are useful to test low frequencies of linear acceleration at amplitudes that would require impractical sled lengths. The purpose of this study was to compare roll-tilt and lateral translation motion perception in 12 healthy subjects across four paradigms: OVAR, VRC, sled translation and rotation about an earth-horizontal axis. Subjects were oscillated in darkness at six frequencies from 0.01875 to 0.6 Hz (peak acceleration equivalent to 10 deg, less for sled motion below 0.15 Hz). Subjects verbally described the amplitude of perceived tilt and translation, and used a joystick to indicate the direction of motion. Consistent with previous reports, tilt perception gain decreased as a function of stimulus frequency in the motion paradigms without concordant canal tilt cues (OVAR, VRC and Sled). Translation perception gain was negligible at low stimulus frequencies and increased at higher frequencies. There were no significant differences between the phase of tilt and translation, nor did the phase significantly vary across stimulus frequency. There were differences in perception gain across the different paradigms. Paradigms that included actual tilt stimuli had the larger tilt gains, and paradigms that included actual translation stimuli had larger translation gains. In addition, the frequency at which there was a crossover of tilt and translation gains appeared to vary across motion paradigm between 0.15 and 0.3 Hz. Since the linear acceleration in the head lateral plane was equivalent across paradigms, differences in gain may be attributable to the presence of linear accelerations in orthogonal directions and/or cognitive aspects based on the expected motion paths.

Beaton, K. H.↗

Translational Vestibulo-Ocular Reflex and Motion Perception During Interaural Linear Acceleration: Comparison of Different Motion Paradigms

The neural mechanisms to resolve ambiguous tilt-translation motion have been hypothesized to be different for motion perception and eye movements. Previous studies have demonstrated differences in ocular and perceptual responses using a variety of motion paradigms, including Off-Vertical Axis Rotation (OVAR), Variable Radius Centrifugation (VRC), translation along a linear track, and tilt about an Earth-horizontal axis. While the linear acceleration across these motion paradigms is presumably equivalent, there are important differences in semicircular canal cues. The purpose of this study was to compare translation motion perception and horizontal slow phase velocity to quantify consistencies, or lack thereof, across four different motion paradigms. Twelve healthy subjects were exposed to sinusoidal interaural linear acceleration between 0.01 and 0.6 Hz at 1.7 m/s/s (equivalent to 10 tilt) using OVAR, VRC, roll tilt, and lateral translation. During each trial, subjects verbally reported the amount of perceived peak-to-peak lateral translation and indicated the direction of motion with a joystick. Binocular eye movements were recorded using video-oculography. In general, the gain of translation perception (ratio of reported linear displacement to equivalent linear stimulus displacement) increased with stimulus frequency, while the phase did not significantly vary. However, translation perception was more pronounced during both VRC and lateral translation involving actual translation, whereas perceptions were less consistent and more variable during OVAR and roll tilt which did not involve actual translation. For each motion paradigm, horizontal eye movements were negligible at low frequencies and showed phase lead relative to the linear stimulus. At higher frequencies, the gain of the eye movements increased and became more inphase with the acceleration stimulus. While these results are consistent with the hypothesis that the neural computational strategies for motion perception and eye movements differ, they also indicate that the specific motion platform employed can have a significant effect on both the amplitude and phase of each.

Beaton, K. H.↗

3D Reconstruction of a Rotating Erupting Prominence

A bright prominence associated with a coronal mass ejection (CME) was seen erupting from the Sun on 9 April 2008. This prominence was tracked by both the Solar Terrestrial Relations Observatory (STEREO) EUVI and COR1 telescopes, and was seen to rotate about the line of sight as it erupted; therefore, the event has been nicknamed the "Cartwheel CME." The threads of the prominence in the core of the CME quite clearly indicate the structure of a weakly to moderately twisted flux rope throughout the field of view, up to heliocentric heights of 4 solar radii. Although the STEREO separation was 48 deg, it was possible to match some sharp features in the later part of the eruption as seen in the 304 Angstrom line in EUVI and in the H alpha-sensitive bandpass of COR1 by both STEREO Ahead and Behind. These features could then be traced out in three dimensional space, and reprojected into a view in which the eruption is directed towards the observer. The reconstructed view shows that the alignment of the prominence to the vertical axis rotates as it rises up to a leading-edge height of approximately equals 2.5 solar radii, and then remains approximately constant. The alignment at 2.5 solar radii differs by about 115 deg. from the original filament orientation inferred from H alpha and EUV data, and the height profile of the rotation, obtained here for the first time, shows that two thirds of the total rotation is reached within approximately equals 0.5 solar radii above the photosphere. These features are well reproduced by numerical simulations of an unstable moderately twisted flux rope embedded in external flux with a relatively strong shear field component.

Thompson, W. T.↗

Simulator for Testing Spacecraft Separation Devices

A report describes the main features of a system for testing pyrotechnic and mechanical devices used to separate spacecraft and modules of spacecraft during flight. The system includes a spacecraft simulator [also denoted a large mobility base (LMB)] equipped with air thrusters, sensors, and data-acquisition equipment. The spacecraft simulator floats on air bearings over an epoxy-covered concrete floor. This free-flotation arrangement enables simulation of motion in outer space in three degrees of freedom: translation along two orthogonal horizontal axes and rotation about a vertical axis. The system also includes a static stand. In one application, the system was used to test a bolt-retraction system (BRS) intended for separation of the lifting-body and deorbit-propulsion stages of the X- 38 spacecraft. The LMB was connected via the BRS to the static stand, then pyrotechnic devices that actuate the BRS were fired. The separation distance and acceleration were measured. The report cites a document, not yet published at the time of reporting the information for this article, that is said to present additional detailed information.

Johnston, Nick↗

Modification of the Passive Vestibulo-Ocular Reflex During and After Short-Duration Spaceflight

The vestibulo-ocular reflex (VOR) is mediated by integration of canal and otolith inputs to generate compensatory eye movements during head movements. We hypothesized that adaptive change in vestibular processing of gravitoinertial cues would be reflected by plane specific modification of the VOR during passive whole-body rotation during and after spaceflight. Using a repeated measures design, the VOR was assessed in four payload crewmembers in yaw, pitch and roll planes during multiple sessions before, during and after an 8 day orbital mission (STS-42). Rotation was about an earth-vertical axis during ground tests, with the head located off-axis by up to 45cm during pitch and roll rotation (peak acceleration less than 0.2g). The motion profiles included sum-of-sinusoids between 0.02 - 1.39 Hz (yaw), single sinusoids between 0.05-1.25 Hz (yaw and pitch) and velocity steps (yaw, pitch and roll). Eye movements were recorded with both video and electro-oculographic techniques. As expected, VOR gain changes were greater in pitch than in yaw. During pitch rotation, there was a progressive shift in the axis of eye movements during the flight, which was also present during the early post-flight period. This increased horizontal component during pitch, most prevalent at 0.2 Hz, was interpreted as an increase in a translational vergence response elicited during eccentric rotation as subjects imagined a wall fixed target. There was also an increased horizontal component during the eccentric roll step runs performed on flight day 7. These results are consistent with a frequency-dependent increase in otolith-mediated translational VOR responses following adaptation to microgravity. We conclude that the adaptive changes in the VOR are likely to be greatest in the frequency range where there is a cross-over of otolith-mediated tilt and translation responses.

Wood, S. J.↗

Improved Position Sensor for Feedback Control of Levitation

An improved optoelectronic apparatus has been developed to provide the position feedback needed for controlling the levitation subsystem of a containerless-processing system. As explained, the advantage of this apparatus over prior optoelectronic apparatuses that have served this purpose stems from the use of an incandescent lamp, instead of a laser, to illuminate the levitated object. In containerless processing, a small object to be processed is levitated (e.g., by use of a microwave, low-frequency electromagnetic, electrostatic, or acoustic field) so that it is not in contact with the wall of the processing chamber or with any other solid object during processing. In the case of electrostatic or low-frequency electromagnetic levitation, real-time measurement of the displacement of the levitated object from its nominal levitation position along the vertical axis (and, in some cases, along one or two horizontal axes) is needed for feedback control of the levitating field.

Hyers, Robert↗