At least 253 records · Page 14

A first principles framework to predict the transient performance of latent heat thermal energy storage

Thermal energy storage (TES) is increasingly recognized as an essential component of efficient Combined Heat and Power (CHP), Concentrated Solar Power (CSP), Heating Ventilation and Air Conditioning (HVAC), and refrigeration as it reduces peak demand while helping to manage intermittent availability of energy (e.g., from solar or wind). Latent Heat Thermal Energy Storage (LHTES) is a viable option because of its high energy storage density. Parametric analysis of LHTES in terms of dimensionless numbers is highly desired as a tool to model LHTES systems. One approach is to develop a model equation so as to minimize the error between the model and data obtained from experiments or simulations. While this approach can produce an accurate correlation applicable within the range of data used for its creation, it does not provide physical understanding of the rate-limiting process controlling the transient behavior of the device. In this paper we present an alternative approach whereby the potential rate-limiting processes are identified from first principles and then the key process is determined as a function of time as a LHTES device is charged. For example, in a simple geometry, the melt-fraction can be expected to vary linearly in time if the heat transfer rate is limited by natural convection of the phase changing material and we show it scales with the PCM Grashof number as $Gr^1_p$ and PCM Prandtl number as $Pr_p^{(1/3)}$. On the other hand, if surface area of solid PCM limits the heat transfer rate, the melt fraction increases asymptotically to reach full melting. The existence of these linear and asymptotic regions and the $Gr^1_pP r^{1/3}_p$ shape of the melt fraction curve is verified using our database of 64 simulations. Of practical importance in designing LHTES devices is the melt fraction at which the heat transfer rate ceases to be limited by convection, after which the heat storage rate deteriorates. For our geometry, this is found to be about 90%. This test case of our methodology shows the value of our approach, that predicting heat storage rate based on the rate-limiting physical phenomenon as a function of time is an effective approach to modeling LHTES devices.

25 ENERGY STORAGE↗

Dispersion of 0.5- to 2-micron aerosol in microG and hypergravity as a probe of convective inhomogeneity in the lung

We used aerosol boluses to study convective gas mixing in the lung of four healthy subjects on the ground (1 G) and during short periods of microgravity (microG) and hypergravity ( approximately 1. 6 G). Boluses of 0.5-, 1-, and 2-micron-diameter particles were inhaled at different points in an inspiration from residual volume to 1 liter above functional residual capacity. The volume of air inhaled after the bolus [the penetration volume (Vp)] ranged from 150 to 1,500 ml. Aerosol concentration and flow rate were continuously measured at the mouth. The dispersion, deposition, and position of the bolus in the expired gas were calculated from these data. For each particle size, both bolus dispersion and deposition increased with Vp and were gravity dependent, with the largest dispersion and deposition occurring for the largest G level. Whereas intrinsic particle motions (diffusion, sedimentation, inertia) did not influence dispersion at shallow depths, we found that sedimentation significantly affected dispersion in the distal part of the lung (Vp >500 ml). For 0.5-micron-diameter particles for which sedimentation velocity is low, the differences between dispersion in microG and 1 G likely reflect the differences in gravitational convective inhomogeneity of ventilation between microG and 1 G.

NASA Discipline Cardiopulmonary↗

Microgravity Flame Spread in Exploration Atmospheres: Pressure, Oxygen, and Velocity Effects on Opposed and Concurrent Flame Spread

Microgravity tests of flammability and flame spread were performed in a low-speed flow tunnel to simulate spacecraft ventilation flows. Three thin fuels were tested for flammability (Ultem 1000 (General Electric Company), 10 mil film, Nomex (Dupont) HT90-40, and Mylar G (Dupont) and one fuel for flame spread testing (Kimwipes (Kimberly-Clark Worldwide, Inc.). The 1g Upward Limiting Oxygen Index (ULOI) and 1g Maximum Oxygen Concentration (MOC) are found to be greater than those in 0g, by up to 4% oxygen mole fraction, meaning that the fuels burned in 0g at lower oxygen concentrations than they did using the NASA Standard 6001 Test 1 protocol. Flame spread tests with Kimwipes were used to develop correlations that capture the effects of flow velocity, oxygen concentration, and pressure on flame spread rate. These correlations were used to determine that over virtually the entire range of spacecraft atmospheres and flow conditions, the opposed spread is faster, especially for normoxic atmospheres. The correlations were also compared with 1g MOC for various materials as a function of pressure and oxygen. The lines of constant opposed flow agreed best with the 1g MOC trends, which indicates that Test 1 limits are essentially dictated by the critical heat flux for ignition. Further evaluation of these and other materials is continuing to better understand the 0g flammability of materials and its effect on the oxygen margin of safety.

Olson, Sandra L.↗

Hanford Waste Treatment Plant Effluent Management Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Hanford Tank Waste Treatment and Immobilization Plant Effluent Management facility (EMF) stack monitor location was qualified using the LV-S1 scale model stack as a baseline, augmented by the LB-S1 and LV-S2 scale model stacks to address the Direct Feed Low Activity Waste Effluent Management Facility Vessel Vent Process (DVP) injection into the main Active Confinement Ventilation (ACV) system duct. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale models and its sampling locations were geometrically similar to the actual stack and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the EMF stack was performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing determines the range of stack flow rates for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. Based on the LV-S1 scale model test DV values, the corresponding stack flow rates for the EMF stack are as listed in Table S1. Table S1. Effluent Management Facility Stack Qualified Flow Range. Stack Parameter EM-1 Minimum Qualified Stack Flow (scfm) 781 Maximum Qualified Stack Flow (scfm) 53,432 The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be =20°. Second, the velocity uniformity at the full-scale stack must be =20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack test at the EMF. Flow angle results were less than 5°; all flow angle results were within the =20° criterion. The velocity uniformity results for each test condition ranged between 2.2% COV and 4.3% COV, which were all within the range of the target % COV values from the scale model tests on the LV-S1, LB-S1, and LV S2 scale models. Based on these stack verification test results, the EMF filtered exhaust stack sampling location meets the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all fan operating configurations. This includes each combination of ACV fan with the DVP exhausters. Further changes to the system configuration or operating conditions that are outside the qualified flow rates described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effects of Sustained Low-Level Elevations of Carbon Dioxide on Cerebral Blood Flow and Autoregulation of the Intracerebral Arteries in Humans

Cerebral blood flow velocity (CBFv) was measured by insonating the middle cerebral arteries of 4 subjects using a 2 Mhz transcranial Doppler. Ambient CO2 was elevated to 0.7% for 23 days in the first study and to 1.2% for 23 days in the same subjects in the second study. By non-parametric testing CBFv was elevated significantly by +35% above pre-exposure levels during the first 1-3 days at both exposure levels after which CBFv progressively readjusted to pre-exposure levels. Despite similar CBFv responses, headache was only reported during the initial phase of exposure to 1.2% CO2. Vascular reactivity to CO2 assessed by rebreathing showed a similar pattern with the CBFv increases early in the exposures being greater than those elicited later. An increase in metabolic rate of the visual cortex was evoked by having the subjects open and close their eyes during a visual stimulus. Evoked CBFv responses measured in the posterior cerebral artery were also elevated in the first 1-3 days of both studies returning to pre-exposure levels as hypercapnia continued. Cerebral vascular autoregulation assessed by raising head pressure during 10 deg head-down tilt both during the low-level exposures and during rebreathing was unaltered. There were no changes in the retinal microcirculation during serial fundoscopy studies. The time-dependent changes in CO2 vascular reactivity might be due either to retention of bicarbonate in brain extracellular fluid or to progressive increases in ventilation, or both. Cerebral vascular autoregulation appears preserved during chronic exposure to these levels of ambient CO2.

Sliwka, U.↗

Effect Of Low External Flow On Flame Spreading Over ETFE Insulated Wire Under Microgravity

Fire safety is one of the most important issues for manned space missions. A likely cause of fires in spacecraft is wire insulation combustion in electrical system. Regarding the wire insulation combustion it important to know the effect of low external flow on the combustion because of the presence of ventilation flow in spacecraft. Although, there are many researches on flame spreading over solid material at low external flows under microgravity, research dealing with wire insulation is very limited. An example of wire insulation combustion in microgravity is the Space Shuttle experiments carried out by Greenberg et al. However, the number of experiments was very limited. Therefore, the effect of low flow velocity is still not clear. The authors have reported results on flame spreading over ETFE (ethylene - tetrafluoroetylene) insulated wire in a quiescent atmosphere in microgravity by 10 seconds drop tower. The authors also performed experiments of polyethylene insulated nichrom wire combustion in low flow velocity under microgravity. The results suggested that flame spread rate had maximum value in low flow velocity condition. Another interesting issue is the effect of dilution gas, especially CO2, which is used for fire extinguisher in ISS. There are some researches working on dilution gas effect on flame spreading over solid material in quiescent atmosphere in microgravity. However the research with low external flow is limited and, of course, the research discussing a relation of the appearance of maximum wire flammability in low flow velocity region with different dilution gas cannot be found yet. The present paper, therefore, investigates the effect of opposed flow with different dilution gas on flame spreading over ETFE insulated wire and change in the presence of the maximum flammability depending on the dilution gas type is discussed within the limit of microgravity time given by ground-based facility.

Nishizawa, Katsuhiro↗

Influence of Gravity on Blood Volume and Flow Distribution

In our previous experiments during NASA Shuttle flights SLS 1 and 2 (9-15 days) and EUROMIR flights (30-90 days) we observed that pulmonary blood flow (cardiac output) was elevated initially, and surprisingly remained elevated for the duration of the flights. Stroke volume increased initially and then decreased, but was still above 1 Gz values. As venous return was constant, the changes in SV were secondary to modulation of heart rate. Mean blood pressure was at or slightly below 1 Gz levels in space, indicating a decrease in total peripheral resistance. It has been suggested that plasma volume is reduced in space, however cardiac output/venous return do not return to 1 Gz levels over the duration of flight. In spite of the increased cardiac output, central venous pressure was not elevated in space. These data suggest that there is a change in the basic relationship between cardiac output and central venous pressure, a persistent "hyperperfusion" and a re-distribution of blood flow and volume during space flight. Increased pulmonary blood flow has been reported to increase diffusing capacity in space, presumably due to the improved homogeneity of ventilation and perfusion. Other studies have suggested that ventilation may be independent of gravity, and perfusion may not be gravity- dependent. No data for the distribution of pulmonary blood volume were available for flight or simulated microgravity. Recent studies have suggested that the pulmonary vascular tree is influenced by sympathetic tone in a manner similar to that of the systemic system. This implies that the pulmonary circulation is dilated during microgravity and that the distribution of blood flow and volume may be influenced more by vascular control than by gravity. The cerebral circulation is influenced by sympathetic tone similarly to that of the systemic and pulmonary circulations; however its effects are modulated by cerebral autoregulation. Thus it is difficult to predict if cerebral perfusion is increased and if there is edema in space. Anecdotal evidence suggests there may be cerebral edema early in flight. Cerebral artery velocity has been shown to be elevated in simulated microgravity. The elevated cerebral artery velocity during simulated microgravity may reflect vasoconstriction of the arteries and not increased cerebral blood flow. The purpose of our investigations was to evaluate the effects of alterations in simulated gravity (+/-), resulting in changes in cardiac output (+/-), and on the blood flow and volume distribution in the lung and brain of human subjects. The first hypothesis of these studies was that blood flow and volume would be affected by gravity, but their distribution in the lung would be independent of gravity and due to vasoactivity changing vascular resistance in lung vessels. The vasodilitation of the lung vasculature (lower resistance) along with increased "compliance" of the heart could account for the absence of increased central venous pressure in microgravity. Secondly, we postulate that cerebral blood velocity is increased in microgravity due to large artery vasoconstriction, but that cerebral blood flow would be reduced due to autoregulation.

Pendergast, D.↗

Development of Pressure Swing Adsorption Technology for Spacesuit Carbon Dioxide and Humidity Removal

Metabolically produced carbon dioxide (CO2) removal in spacesuit applications has traditionally been accomplished utilizing non-regenerative Lithium Hydroxide (LiOH) canisters. In recent years, regenerative Metal Oxide (MetOx) has been developed to replace the Extravehicular Mobility Unity (EMU) LiOH canister for extravehicular activity (EVA) missions in micro-gravity, however, MetOx may carry a significant weight burden for potential use in future Lunar or planetary EVA exploration missions. Additionally, both of these methods of CO2 removal have a finite capacity sized for the particular mission profile. Metabolically produced water vapor removal in spacesuits has historically been accomplished by a condensing heat exchanger within the ventilation process loop of the suit life support system. Advancements in solid amine technology employed in a pressure swing adsorption system have led to the possibility of combining both the CO2 and humidity control requirements into a single, lightweight device. Because the pressure swing adsorption system is regenerated to space vacuum or by an inert purge stream, the duration of an EVA mission may be extended significantly over currently employed technologies, while markedly reducing the overall subsystem weight compared to the combined weight of the condensing heat exchanger and current regenerative CO2 removal technology. This paper will provide and overview of ongoing development efforts evaluating the subsystem size required to manage anticipated metabolic CO2 and water vapor generation rates in a spacesuit environment.

Papale, William↗

Trace Contaminant Control Test Bed for Evaluation of TCC Prototypes with Vacuum Regenerable and Non-Regenerable Sorbents

A new Space Suit Exploration Portable Life Support System (xPLSS) is being designed, built, integrated, and tested into the Extra-Vehicular Mobility Unit (xEMU). The Trace Contaminant Control (TCC) system is a component in the oxygen ventilation loop of xPLSS that removes contaminants generated by the crewmembers’ metabolic processes. The primary trace contaminants that must be removed include ammonia (NH3), carbon monoxide (CO), formaldehyde (CH2O), and methyl mercaptan (CH3SH). The current state-of-the-art TCC sorbent is non-regenerable activated carbon. As a non-regenerable sorbent, its use negatively impacts the logistics for future missions. Thus, an ideal solution can be a vacuum-regenerable sorbent integrated with the xPLSS CO2/H2O removal system. To test new designs and sorbents, XploSafe has constructed a recirculating test bed that mimics the environment within the xPLSS by providing concentrations of the trace contaminant analytes generated at the operating temperature, humidity, pressure, and flow rates of the xPLSS. This system can perform regeneration or desorption by exposing the sorbent to a pressure swing from 4.3 psia to <1 torr over approximately 2 minutes. Using this test system, XploSafe evaluated various TCC prototypes constructed using rapid prototyping techniques and identified a process that allows vacuum regenerative TCC designs to be quickly examined for flow, pressure drop, and performance. By using toluene as a segregate for volatile organics, this test system was evaluated using both vacuum regenerable and non-regenerable sorbents to demonstrate the operational effectiveness of these sorbents in maintaining the concentrations of the trace contaminant analytes below the 7-day Spacecraft Maximum Allowable Concentrations.

Nicholas Materer↗

Testing and Results of Vacuum Swing Adsorption Units for Spacesuit Carbon Dioxide and Humidity Control

A principal concern for extravehicular activity (EVA) spacesuits is the capability to control carbon dioxide (CO2) and humidity (H2O) for the crewmember. The release of CO2 in a confined or unventilated area is dangerous for human health and leads to asphyxiation; therefore, CO2 and H2O control become leading factors in the design and development of the spacesuit. An amine-based CO2 and H2O vapor sorbent for use in pressure-swing regenerable beds has been developed by Hamilton Sundstrand. The application of solidamine materials with vacuum swing adsorption technology has shown the capacity to concurrently manage CO2 and H2O levels through a fully regenerative cycle eliminating mission constraints imposed with nonregenerative technologies. Two prototype solid amine-based systems, known as rapid cycle amine (RCA), were designed to continuously remove CO2 and H2O vapor from a flowing ventilation stream through the use of a two-bed amine based, vacuum-swing adsorption system. The Engineering and Science Contract Group (ESCG) RCA implements radial flow paths, whereas the Hamilton Sundstrand RCA was designed with linear flow paths. Testing was performed in a sea-level pressure environment and a reduced-pressure environment with simulated human metabolic loads in a closed-loop configuration. This paper presents the experimental results of laboratory testing for a full-size and a sub-scale test article. The testing described here characterized and evaluated the performance of each RCA unit at the required Portable Life Support Subsystem (PLSS) operating conditions. The test points simulated a range of crewmember metabolic rates. The experimental results demonstrated the ability of each RCA unit to sufficiently remove CO2 and H2O from a closed loop ambient or sub-ambient atmosphere.

McMillin, Summer D.↗

A New Test Method for Material Flammability Assessment in Microgravity and Extraterrestrial Environments

The standard oxygen consumption (cone) calorimeter (described in ASTM E 1354 and NASA STD 6001 Test 2) is modified to provide a bench-scale test environment that simulates the low velocity buoyant or ventilation flow generated by or around a burning surface in a spacecraft or extraterrestrial gravity level. The Equivalent Low Stretch Apparatus (ELSA) uses an inverted cone geometry with the sample burning in a ceiling fire (stagnation flow) configuration. For a fixed radiant flux, ignition delay times for characterization material PMMA are shown to decrease by a factor of three at low stretch, demonstrating that ignition delay times determined from normal cone tests significantly underestimate the risk in microgravity. The critical heat flux for ignition is found to be lowered at low stretch as the convective cooling is reduced. At the limit of no stretch, any heat flux that exceeds the surface radiative loss at the surface ignition temperature is sufficient for ignition. Regression rates for PMMA increase with heat flux and stretch rate, but regression rates are much more sensitive to heat flux at the low stretch rates, where a modest increase in heat flux of 25 kW/m2 increases the burning rates by an order of magnitude. The global equivalence ratio of these flames is very fuel rich, and the quantity of CO produced in this configuration is significantly higher than standard cone tests. These results [2] demonstrate the ELSA apparatus allows us to conduct normal gravity experiments that accurately and quantifiably evaluate a material s flammability characteristics in the real-use environment of spacecraft or extra-terrestrial gravitational acceleration. These results also demonstrate that current NASA STD 6001 Test 2 (standard cone) is not conservative since it evaluates materials flammability with a much higher inherent buoyant convective flow.

Olson, S. L.↗

Testing and Results of Vacuum Swing Adsorption Units for Spacesuit Carbon Dioxide and Humidity Control

A principal concern for extravehicular activity (EVA) space suits is the capability to control carbon dioxide (CO2) and humidity (H2O) for the crewmember. The release of CO2 in a confined or unventilated area is dangerous for human health and leads to asphyxiation; therefore, CO2 and H2O become leading factors in the design and development of the spacesuit. An amine-based CO2 and H2O vapor sorbent for use in pressure-swing re-generable beds has been developed by Hamilton Sundstrand. The application of solid-amine materials with vacuum swing adsorption technology has shown the capacity to concurrently manage CO2 and H2O levels through a fully regenerative cycle eliminating mission constraints imposed with non-regenerative technologies. Two prototype solid amine-based systems, known as rapid cycle amine (RCA), were designed to continuously remove CO2 and H2O vapor from a flowing ventilation stream through the use of a two-bed amine based, vacuum-swing adsorption system. The Engineering and Science Contract Group (ESCG) RCA is the first RCA unit implementing radial flow paths, whereas the Hamilton Sundstrand RCA was designed with linear flow paths. Testing was performed in a sea-level pressure environment and a reduced-pressure environment with simulated human metabolic loads in a closed-loop configuration. This paper presents the experimental results of laboratory testing for a full-size and a sub-scale test article. The testing described here characterized and evaluated the performance of each RCA unit at the required Portable Life Support Subsystem (PLSS) operating conditions. The test points simulated a range of crewmember metabolic rates. The experimental results demonstrate the ability of each RCA unit to sufficiently remove CO2 and H2O from a closed loop ambient or subambient atmosphere.

McMillin, Summer↗

Multidimensional Effects on Ignition, Transition, and Flame Spread in Microgravity

Localized ignition is initiated by an external radiant source at the middle of a thermally thin sample under external slow flow, simulating fire initiation in a spacecraft with a slow ventilation flow. Two ignition configurations are simulated, one across the sample surface creating a line shaped flame front (two-dimensional, 2-D, configuration) and the other a small circular ignition (three-dimensional, 3-D, configuration). Ignition, subsequent transition to simultaneously upstream and downstream flame spread, and flame growth behavior are studied experimentally and theoretically. Details of our theoretical models and numerical techniques can be found in previous publications. The effects of the sample width on the transition and subsequent flame spread, and flame spread along open edges of a thermally thin paper sample are determined. Experimental observations of flame spread phenomena were conducted in the 10 s drop tower and also on the space shuttle STS-75 flight to determine the effects of oxygen concentration and external flow velocity on flame spread rate and flame growth pattern. Finally, effects of confinement in a small test chamber on the transition and subsequent flame spread are examined. The results of these studies are briefly reported.

Kashiwagi, T.↗

WIPP Safety Significant Confinement Ventilation System (SSCVS) HEPA Filtration System - 20165

Construction and major equipment fabrication are underway for a new ventilation exhaust system at the Waste Isolation Pilot Plant (WIPP). The new system will provide continuous High Efficiency Particulate Air (HEPA) filtration of the exhaust from the WIPP underground while meeting the ventilation demands for expanded waste emplacement and mining operations over the next 40 years. The integrated system design provides for reducing the salt, clay and diesel particulates from the exhaust airflow from the mine, prior to full filtration using Nuclear Safety Significant HEPA filters. The SSCVS design and equipment provides for continuous HEPA filtration over a wide range of operating and environmental conditions. The new exhaust system connects to the existing underground exhaust shaft, and the exhaust air flows from the underground through Salt Reduction Units (SRUs) to protect the final filter banks from excessive moisture and rapid salt/dust buildup. Each of the six (6) SRUs consists of a demister to remove entrained moisture, a dry salt remover unit to filter approximately 90% of the entrained salt/dust, and an automated water treatment system to periodically clean the demisters and to remove salt from the SRU filters. At the maximum expected exhaust flowrate of 540,000 Cubic Feet per Minute (CFM) / 255 Cubic Meters per Second (m{sup 3}/s), five (5) salt removal units will be in operation with one unit in standby or maintenance. An in-line variable frequency drive booster fan will offset pressure losses through each SRU and reduce the relative humidity of the air exiting the SRUs. In the event of a high radiation alarm from the underground Continuous Air Monitors (CAMs), the SRUs will be automatically bypassed, which places the SRS and building outside of the Safety Significant confinement boundary. From the SRUs, the exhaust is directed to the HEPA filter banks located in the New Filter Building. The exhaust system is designed to provide continuous HEPA filtration prior to release to the exhaust stack. There are 22 HEPA filter banks rated at 27,000 CFM / 12.75 m{sup 3}/s each. Each filter bank has two stages of pre-filters and two stages of HEPA filters. The filtered air from each of the 22 filter banks discharges into a common concrete plenum, which is maintained under a negative pressure by the main exhaust fans. Six 1,000 HP variable frequency drive exhaust fans are provided on the south side of the plenum. At the maximum expected exhaust flow of 540,000 CFM, four exhaust fans and twenty filter banks will be in operation. The fans discharge vertically to a separate concrete exhaust plenum. The filtered exhaust is routed from the exhaust plenum to a 125-foot-tall exhaust stack via a 13-foot diameter duct. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Automated fault detection and diagnosis of airflow and refrigerant charge faults in residential HVAC systems using IoT-enabled measurements

While automated fault detection and diagnosis (AFDD) in residential heating, ventilation, and air-conditioning (HVAC) using smart thermostat data is gaining increasing attention in recent times, it still requires in-depth investigation for market adoption, especially with real-life data. Furthermore, this paper proposes an Internet of Things (IoT) - based approach that adds a smart sensor to the smart thermostat data to carry out AFDD. The approach uses a model which predicts enthalpy change across the evaporator and compares the prediction to the measured enthalpy change. Deviations which exceed analytically determined thresholds then signal faults in the HVAC system. The faults detected are either installation related or degradation related. Experimental tests were carried out in four homes located in Norman, Oklahoma. From the tests, installation issues like indoor/outdoor mismatch were detected in two homes, while a 30% low charge and low indoor airflow rate were detected in one home. The results show that the proposed AFDD algorithm was able to successfully detect two prevalent faults, namely low indoor airflow and low refrigerant charge. Unlike most of the smart thermostat-based approaches, the proposed IoT-based approach can detect and diagnose both faults but only require one additional sensor which is provided by smart thermostat manufacturers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessing the performance of global thermostat adjustment in commercial buildings for load shifting demand response

Abstract Efficiently leveraging new sources of flexibility is critical to mitigating load balancing challenges posed by variable renewable resources. The thermal inertia of commercial buildings allows us to shift their power consumption on minute to hourly timescales to provide demand response to the grid while maintaining occupant comfort. Global thermostat adjustment (GTA) provides a readily available and scalable approach for implementing load shifting demand response using commercial heating, ventilation, and air conditioning (HVAC) systems, since it leverages the inherent sophistication of modern building automation systems. However, there is an incomplete understanding of GTA’s performance for this purpose and its impact on building systems and occupant comfort. In this paper, we explore the performance of GTA by analyzing results from nearly nine hundred experiments on eight university campus buildings in Michigan and North Carolina. Using GTA, we manipulate each building’s thermostat setpoints causing the building to shift its power consumption with respect to its baseline. We quantify the magnitude of HVAC power response, energy use of HVAC subsystems, and impact on occupant comfort. Finally, we connect our experimental results with power system operation using an optimization model that coordinates GTA actions across a large collection of grid-interactive efficient buildings (GEBs) to reduce high ramp rates on the grid and mitigate renewable energy curtailment. Overall, our work finds that the impacts on HVAC subsystems are often complex, and may result in additional energy being consumed by fans and terminal reheat. These effects must be considered when using GTA for load shifting. Additionally, we demonstrate that occupant comfort, as assessed by indoor temperature and humidity, can be maintained during GTA events. From a societal perspective, our modeling work finds that the additional renewable energy that can be integrated through the use of GTA strategies eclipses any additional energy consumed by buildings.

Keskar, Aditya (ORCID:0000000244617980)↗

Reliability of the Danish Aerospace Corporation Portable Pulmonary Function System

Metabolic gas analysis is a critical component of investigations that measure cardio-pulmonary exercise responses during and after long-duration spaceflight. The primary purpose of the current study was to determine the reliability and intra-subject repeatability of a metabolic gas analysis device, the Portable Pulmonary Function System (PPFS), designed for use on the International Space Station (ISS). The second objective of this study was to directly compare PPFS measurements of expired oxygen and carbon dioxide (FEO2 and FECO2) to values obtained from a well-validated clinical metabolic gas analysis system (ParvoMedics TrueOne (c) [PM]). Eight subjects performed four peak cycle tests to maximal exertion. The first test was used to prescribe work rates for the subsequent test sessions. Metabolic gas analysis for this test was performed by the PM, but samples of FEO2 and FECO2 also were simultaneously collected for analysis by the PPFS. Subjects then performed three additional peak cycle tests, consisting of three 5-min stages designed to elicit 25%, 50%, and 75% maximal oxygen consumption (VO2max) followed by stepwise increases of 25 W/min until subjects reached volitional exhaustion. Metabolic gas analysis was performed using the PPFS for these tests. Intraclass correlation coefficients (ICC), within-subject standard deviations (WS SD), and coefficients of variation (CV%) were calculated for the repeated exercise tests. Mixed model regression analysis was used to compare paired FEO2 and FECO2 values obtained from the PPFS and the PM during the initial test. The ICC values for oxygen consumption (VO2), carbon dioxide production (VCO2), and ventilation (VE) indicate that the PPFS is highly reliable (0.79 to 0.99) for all exercise levels tested; however, ICCs for respiratory exchange ratio (RER) were low ( 0.11 - 0.51), indicating poor agreement between trials during submaximal and maximal exercise. Overall, CVs ranged from 1.6% to 6.7% for all measurements, a finding consistent with reported values that were obtained using other metabolic gas analysis techniques. The PPFS and PM produced comparable FEO2 data; however, there was less agreement between measures of FECO2 obtained from the two devices, particularly at lower CO2 concentrations. The PPFS appears, in practically all respects, to yield highly reliable metabolic gas analysis data. Lower reliability of RER measurements reported in the literature and likely is not a function of the PPFS device. Further examination of PPFS CO2 data is warranted to better understand the limitations of these PPFS measurements. Overall, the PPFS when used for repeated measures of cardio-pulmonary exercise should provide accurate and reliable data for studies of human adaptation to spaceflight.

Portable Pulmonary Function System (PPFS)↗

TCCR Operational Summary and Optimization for Tank 9 Processing - 20314

Savannah River Remediation (SRR) manages and operates the liquid waste facilities at Savannah River Site (SRS) for the Department of Energy (DOE). Stored liquid waste is a complex mixture of insoluble solids (sludge) and soluble salts in an alkaline solution. SRR has deployed the Tank Closure Cesium Removal (TCCR) system, a tank-side ion exchange process, to remove radioactive cesium from salt waste and enable onsite disposal of the resulting decontaminated salt solution as low-level waste at the Saltstone facilities. The TCCR system consists of two prefilters, four ion exchange (IX) columns, one resin trap, and a ventilation system. The IX process uses a form of inorganic crystalline silicotitanate (CST), which has a high affinity for cesium and other alkali metals, strontium, and actinides. This process is currently deployed utilizing salt feed from Tank 10, with future plans to dissolve solid salt in Tank 9 and transfer the salt solution to Tank 10 for processing through TCCR. The feed for TCCR must be created from salt-cake in Tank 10 through a dissolution process. Once enough salt has been dissolved, a qualification process is entered. This process characterizes the feed and ensures the cesium loading on the columns will not cause boiling of waste within the columns during or after processing. Once the batch has been qualified, salt waste is fed to the TCCR system through a transfer pump in the center of the tank. The waste is filtered through a set of two shielded, dead-end prefilters that prevent solids buildup in the columns. The filtered salt solution then travels to the shielded IX columns, which can be operated individually or in series, where the cesium is sorbed on the CST media. The decontaminated salt solution (DSS) then travels through a resin trap and out of the module to Tank 11. TCCR has successfully processed approximately 795,000 L of Tank 10H radioactive salt waste over two batches to date. There has not yet been a system induced shutdown. The prefilters performed as expected with only minor degradation in recovery of differential pressure after a backflush sequence. The time between backflushes decreased as each batch reached the end of processing. The hydraulics in the IXCs mostly performed as expected at all flow rates, except for one IXC that will be further investigated during Batch 3 processing. The TCCR system has shown some opportunities for more efficient processing during the length of the demonstration so far. For future processing of material from Tank 9H through Tank 10H and the TCCR unit, TCCR 1A will implement changes to the prefilters and the IXCs. The prefilters will have an increased surface area and a new filter media in an effort to increase time between filter swaps and improve backwashing cleaning capability. The IXCs will have a reduced diameter to allow for increased heat transfer out of the column and increased loading of Cs-137. Additionally, a new form of CST with an increased kinetic performance is being investigated for use during TCCR 1A operation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗