Diamond Analyzed by Secondary Electron Emission Spectroscopy

Diamond is a promising semiconductor material for novel electronic applications because of its chemical stability and inertness, heat conduction properties, and so-called negative electron affinity (NEA). When a surface has NEA, electrons generated inside the bulk of the material are able to come out into the vacuum without any potential barrier (work function). Such a material would have an extremely high secondary electron emission coefficient o, very high photoelectron (quantum) yield, and would probably be an efficient field emitter. Chemical-vapor-deposited (CVD) polycrystalline diamond films have even more advantages than diamond single crystals. Their fabrication is relatively easy and inexpensive, and they can be grown with high levels of doping--consequently, they can have relatively high conductivity. Because of these properties, diamond can be used for cold cathodes and photocathodes in high-power electronics and in high-frequency and high-temperature semiconductor devices.

Krainsky, Isay L.↗

Ultraviolet stability and contamination analysis of Spectralon diffuse reflectance material

A detailed chemical analysis was carried out on Spectralon, a highly Lambertian, diffuse reflectance material. Results of this investigation unambiguously identified the presence of an organic (hydrocarbon) impurity intrinsic to the commercial material. This impurity could be removed by a vacuum bake-out procedure and was identified as the cause of optical changes (degradation) that occur in the material when exposed to UV light. It was found that when this impurity was removed, the Spectralon material was photochemically stable and maintained its reflectance properties even after extensive solar UV exposure.

Stiegman, Albert E.↗

Gas Effluent Analysis of the Heat Melt Compactor

The Heat Melt Compactor (HMC) reduces volume, heat sterilizes, stabilizes, and manages gas and water effluent of the International Space Station (ISS) trash. Processing the trash at high temperatures produces volatile gas compounds that need to be treated before venting to cabin and/or the Vacuum Exhaust System (VES) in the ISS. The release of gases may not meet the Spacecraft Maximum Allowable Concentrations (SMAC) requirement, if vented directly into cabin, and/or gases are incompatible for venting to the VES. In order to assess the HMC gas release and venting parameters, effluent gas analysis is conducted to determine contaminant load. This paper will analyze different collection and analytical methods of the effluent gas, and report corresponding data, such that these results can be used for process design and effluent management.

Heat Melt Compactor↗

Platelet injectors for Space Shuttle orbit maneuvering engine

The Space Shuttle Orbit Maneuvering Subsystem Rocket Engine employs a platelet element injector concept. This injector has demonstrated 316-sec vacuum specific impulse performance under simulated altitude conditions when tested with a milled slot/electroformed nickel close-out regenerative chamber and a full 71 area ratio nozzle. To date, over 300 altitude engine tests and 300 stability bomb tests have demonstrated stable, erosion free operation with this concept to test durations of 150 seconds. The injector and chamber also meet the reusable requirements of the shuttle with a cycle life capability in excess of 1000 cycles. An extensive altitude restart program has also demonstrated OMS-engine operation over large variations in the burn and coast times with helium saturated propellants.

Kahl, R. C.↗

Miniaturized Mercury Ion Clock for Ultrastable Deep Space Applications

We have recently completed a prototype ion-clock physics package based on Hg ions shuttled between a quadrupole and a 16-pole rf trap. With this architecture we have demonstrated short-term stability ~2-3x10-13 at 1 second, averaging to 10-15 at 1 day. This development shows that H-maser quality stabilities can be produced in a small clock package, comparable in size to an ultra-stable quartz oscillator required for holding 1-2x10-13 at 1 second. This performance was obtained in a sealed vacuum configuration where only a getter pump was used to maintain vacuum. The vacuum tube containing the traps has now been under sealed vacuum conditions for nearly 1.5 years with no measurable degradation of ion trapping lifetimes or clock short-term performance. Because the tube is sealed, the Hg source and Neon buffer gas are held indefinitely, for the life of the tube. There is no consumption of Hg in this system unlike in a Cs beam tube where lifetime is often limited by Cs depletion.

mercury ion clocks↗

Compact Microwave Mercury Ion Clock for Deep-Space Applications

We have recently completed a breadboard ion-dock physics package based on Kg ions shuttled between a quadrupole and a 16-pole rf trap. With this architecture we have demonstrated short-term stability -1-2xl0-13 at 1 second, averaging to 10-15 at 1 day. This development shows that 8- maser quality stabilities can be produced in a small clock package, comparable in size to an oItra-stable quartz oscillator required for holding 1-2xl0-13 at 1 second. This performance was obtained in a sealed vacuum configuration where only agetter pump was used to maintain vacuum. The vacuum tube containing the traps has now been onder sealed vacuum conditions for nearly two years with no measurable degradation of ion trapping lifetimes or clock short-term performance. We have fabricated the vacuum tube, ion trap and UV windows from materials that will allow a - 400 C tube bake-out to prepare for tube sealoff. This approach to the vacuum follows the methods used in mght vacuum tube electronics, such as flight TWTA's where tube operation lifetime and shelf life of up to 15 years is achieved. We use neon as a buffer gas with 2-3 times less pressure induced frequency pulling than helium and, being heavier, negligable diffusion losses will occur over the operation lifetime.

space clock↗

Development of techniques and associated instrumentation for high temperature emissivity measurements

The progress during the sixth quarterly period is reported on construction and assembly of a test facility to determine the high temperature emittance properties of candidate thermal protection system materials for the space shuttle. This facility will provide simulation of such reentry environment parameters as temperature, pressure, and gas flow rate to permit studies of the effects of these parameters on the emittance stability of the materials. Also reported are the completed results for emittance tests on a set of eight Rene 41 samples and one anodized titanium alloy sample which were tested at temperatures up to 1600 F in vacuum. The data includes calorimetric determinations of total hemispherical emittance, radiometric determinations of total and spectral normal emittance, and pre- and post-test room temperature reflectance measurements.

Cunnington, G. R.↗

High Temperature VARTM of Phenylethynyl Terminated Imides

Fabrication of composite structures using vacuum assisted resin transfer molding (VARTM) is generally more affordable than conventional autoclave techniques. Recent efforts have focused on adapting VARTM for the fabrication of high temperature composites. Due to their low melt viscosity and long melt stability, certain phenylethynyl terminated imides (PETI) can be processed into composites using high temperature VARTM (HT-VARTM). However, one of the disadvantages of the current HT-VARTM resin systems has been the high porosity of the resultant composites. For aerospace applications, the desired void fraction of less than 2% has not yet been achieved. In the current study, two PETI resins, LaRC PETI-330 and LaRC PETI-8 have been used to make test specimens using HT-VARTM. The resins were infused into ten layers of IM7-6K carbon fiber 5-harness satin fabric at 260 C or 280 C and cured at 371 C. Initial runs yielded composites with high void content, typically greater than 7% by weight. A thermogravimetric-mass spectroscopic study was conducted to determine the source of volatiles leading to high porosity. It was determined that under the thermal cycle used for laminate fabrication, the phenylethynyl endcap was undergoing degradation leading to volatile evolution. By modifying the thermal cycle used in laminate fabrication, the void content was reduced significantly (typically approximately 3%). Densities of the composites were determined using a density gradient column and the glass transition temperatures of the cured composites were measured by dynamic mechanical analysis. Photomicrographs of the panels were taken and void contents were determined by acid digestion. The results of this work are presented herein.

Cano, Roberto J.↗

High Temperature VARTM of Phenylethynyl Terminated Imides

Depending on the part type and quantity, fabrication of composite structures using vacuum assisted resin transfer molding (VARTM) can be more affordable than conventional autoclave techniques. Recent efforts have focused on adapting VARTM for the fabrication of high temperature composites. Due to their low melt viscosity and long melt stability, certain phenylethynyl terminated imides (PETI) can be processed into composites using high temperature VARTM (HT-VARTM). However, one of the disadvantages of the current HT-VARTM resin systems has been the high porosity of the resultant composites. For aerospace applications, the desired void fraction of less than 2% has not yet been achieved. In the current study, two PETI resins, LaRC PETI-330 and LaRC PETI-8 have been used to make test specimens using HT-VARTM. The resins were infused into ten layers of IM7-6K carbon fiber 5-harness satin fabric at 260 C or 280 C and cured at temperature up to 371 C. Initial runs yielded composites with high void content, typically greater than 7% by weight. A thermogravimetric-mass spectroscopic study was conducted to determine the source of volatiles leading to high porosity. It was determined that under the thermal cycle used for laminate fabrication, the phenylethynyl endcap was undergoing degradation leading to volatile evolution. This finding was unexpected as high quality composite laminates have been fabricated under higher pressures using these resin systems. The amount of weight loss experienced during the thermal cycle was only about 1% by weight, but this leads to a significant amount of volatiles in a closed system. By modifying the thermal cycle used in laminate fabrication, the void content was significantly reduced (typically ~ 3% or less). The results of this work are presented herein.

Ghose, Sayata↗

High Temperature VARTM of Phenylethynyl Terminated Imides (PETI) Resins

Fabrication of composite structures using vacuum assisted resin transfer molding (VARTM) is generally more affordable than conventional autoclave techniques. Recent efforts have focused on adapting VARTM for the fabrication of high temperature composites. Due to their low melt viscosity and long melt stability, certain phenylethynyl terminated imides (PETI) can be processed into composites using high temperature VARTM (HT-VARTM). However, one of the disadvantages of the current HT-VARTM resin systems has been the high porosity of the resultant composites. For aerospace applications a void fraction of less than 2% is desired. In the current study, two PETI resins, LARCTM PETI-330 and LARCTM PETI-8 have been used to fabricate test specimens using HT-VARTM. The resins were infused into carbon fiber preforms at 260 C and cured between 316 C and 371 C. Modifications to the thermal cycle used in the laminate fabrication have reduced the void content significantly (typically < 3%) for carbon fiber biaxially woven fabric. Photomicrographs of the panels were taken and void contents were determined by acid digestion. For carbon fiber uniaxial fabric, void contents of less than 2% have been obtained using both PETI-8 and PETI-330. Mechanical properties of the panels were determined at both room and elevated temperatures. These include short beam shear and flexure tests. The results of this work are presented herein.

Ghose, Sayata↗

Phenylethynyl Terminated Imide (PETI) Composites Made by High Temperature VARTM

Fabrication of composite structures using vacuum assisted resin transfer molding (VARTM) is generally more affordable than conventional autoclave techniques. Recent efforts have focused on adapting VARTM for the fabrication of high temperature composites. Due to their low melt viscosity and long melt stability, certain phenylethynyl terminated imides (PETI) can be processed into composites using high temperature VARTM (HT-VARTM). However, one of the disadvantages of the current HT-VARTM resin systems has been the high porosity of the resultant composites. For aerospace applications, a void fraction of <2% is desired. In the current study, two PETI resins, LARC. PETI-330 and LARC. PETI-8 have been used to fabricate test specimens using HT-VARTM. The resins were infused into carbon fiber preforms at 260 C and cured between 316 and 371 C. Photomicrographs of the panels were taken and void contents were determined by acid digestion. Modifications to the thermal cycle used in the laminate fabrication have reduced the void content significantly; typically .3% for carbon fiber biaxially woven fabric and less than 2% for carbon fiber uniaxial fabric. Mechanical properties (short beam shear and flexure) of the panels were determined at both room and elevated temperatures. The results of this work are presented herein. This paper is declared a work of the U.S. Government and is not subject to copyright protection in the United States.

Chose, Sayata↗

Lightweight ZERODUR: Validation of Mirror Performance and Mirror Modeling Predictions

Upcoming spaceborne missions, both moderate and large in scale, require extreme dimensional stability while relying both upon established lightweight mirror materials, and also upon accurate modeling methods to predict performance under varying boundary conditions. We describe tests, recently performed at NASA's XRCF chambers and laboratories in Huntsville Alabama, during which a 1.2 m diameter, f/1.2988% lightweighted SCHOTT lightweighted ZERODUR(TradeMark) mirror was tested for thermal stability under static loads in steps down to 230K. Test results are compared to model predictions, based upon recently published data on ZERODUR(TradeMark). In addition to monitoring the mirror surface for thermal perturbations in XRCF Thermal Vacuum tests, static load gravity deformations have been measured and compared to model predictions. Also the Modal Response(dynamic disturbance) was measured and compared to model. We will discuss the fabrication approach and optomechanical design of the ZERODUR(TradeMark) mirror substrate by SCHOTT, its optical preparation for test by Arizona Optical Systems (AOS). Summarize the outcome of NASA's XRCF tests and model validations

technology↗

Investigation of Test Methods, Material Properties, and Processes for Solar Cell Encapsulents

The technical activities were directed toward the assessment of encapsulation processes for use with ethylene/vinyl acetate copolymer as the pottant. Potentially successful formulations were prepared by compounding the raw polymer with ultraviolet absorbers and crosslinking agents to give stabilized and curable compositions. The compounded resin was then converted to a more useful form with an extruder to give pottant in sheets that could be more easily used in lamination. After experimenting with various techniques, the vacuum-bag process was found to be an excellent encapsulation method. Miniature single-celled and multi-celled solar modules of both substrate and superstrate designs were prepared by this technique. The resulting modules were of good appearance, were bubble-free, and successfully passed the thermal cycle test.

Source record↗

Performance of an ablator for Space Shuttle inorbit repair in an arc-plasma airstream

An ablator patch material performed well in an arc plasma environment simulating nominal Earth entry conditions for the Space Shuttle. Ablation tests using vacuum molded cones provided data to optimize the formulation of a two part polymer system for application under space conditions. The blunt cones were made using a Teflon mold and a state of the art caulking gun. Char stability of formulations with various amounts of catalyst and diluent were investigated. The char was found to be unstable in formulations with low amounts of catalyst and high amounts of diluent. The best polymer system determined by these tests was evaluated using a half tile patch in a multiple High Temperature Reusable surface Insulation tile model. It was demonstrated that this ablator could be applied in a space environment using a state of the art caulking gun, would maintain the outer mold line of the thermal protection system during entry, and would keep the bond line temperature at the aluminum tile interface below the design limit.

Stewart, D. A.↗

Strategy for contamination control to improve Wide-Field/Planetary Camera far-ultraviolet performance

A multifaceted contamination control strategy has been developed for the second generated Wide-Field and Planetary Camera (WFPC-2) to improve the FUV stability by several orders of magnitude, compared to the first camera (WFPC-1). The strategy involves: improved on-orbit boil-off capability of the detector optics, added internal shielding and instrument venting, in-process subassembly vacuum bakeout at elevated temperatures, material substitution, sample testing in ultraclean vacuum facility, and internal instrument contamination-transport modeling. A science performance goal of 1 percent photometric accuracy at 1470 A over an extended time (of at least 30 days) has been established as a contamination control target for WFPC-2. The WFPC-2 is currently planned to be launched by the Shuttle in mid-1993 and replace the WFPC-1 which was recently launched with the HST.

Leschly, Kim↗

NPP VIIRS Geometric Performance Status

Visible Infrared Imager Radiometer Suite (VIIRS) instrument on-board the National Polar-orbiting Operational Environmental Satellite System (NPOESS) Preparatory Project (NPP) satellite is scheduled for launch in October, 2011. It is to provide satellite measured radiance/reflectance data for both weather and climate applications. Along with radiometric calibration, geometric characterization and calibration of Sensor Data Records (SDRs) are crucial to the VIIRS Environmental Data Record (EDR) algorithms and products which are used in numerical weather prediction (NWP). The instrument geometric performance includes: 1) sensor (detector) spatial response, parameterized by the dynamic field of view (DFOV) in the scan direction and instantaneous FOV (IFOV) in the track direction, modulation transfer function (MTF) for the 17 moderate resolution bands (M-bands), and horizontal spatial resolution (HSR) for the five imagery bands (I-bands); 2) matrices of band-to-band co-registration (BBR) from the corresponding detectors in all band pairs; and 3) pointing knowledge and stability characteristics that includes scan plane tilt, scan rate and scan start position variations, and thermally induced variations in pointing with respect to orbital position. They have been calibrated and characterized through ground testing under ambient and thermal vacuum conditions, numerical modeling and analysis. This paper summarizes the results, which are in general compliance with specifications, along with anomaly investigations, and describes paths forward for characterizing on-orbit BBR and spatial response, and for improving instrument on-orbit performance in pointing and geolocation.

Lin, Guoqing↗

Compact Microwave Mercury Ion Clock for Space Applications

We have recently completed a breadboard ion-clock physics package based on Hg ions shuttled between a quadrupole and a 16-pole rf trap. With this architecture we have demonstrated short-term stability approximately 1 - 2 x 10(exp -13) at 1 second, averaging to 10(exp -15) at 1 day. This development shows that H-maser quality stabilities can be produced in a small clock package, comparable in size to an ultra-stable quartz oscillator required for holding 1 - 2 x 10(exp -13) at 1 second. This performance was obtained in a sealed vacuum configuration where only a getter pump was used to maintain vacuum. The vacuum tube containing the traps has now been under sealed vacuum conditions for nearly three years with no measurable degradation of ion trapping lifetimes or clock short-term performance. We have fabricated the vacuum tube, ion trap and UV windows from materials that will allow an approximately 400 C bake-out to prepare for tube seal-off. This approach to the vacuum follows the methods used in flight vacuum tube electronics, such as flight TWTA's where tube operation lifetime and shelf life of up to 15 years is achieved.

Atomic Clock↗

Progress on Small Mercury Ion Clock for Space Applications

We have recently completed a breadboard ion-clock physics package based on Hg ions shuttled between a quadrupole and a 16-pole rf trap. With this architecture we have demonstrated short-term stability approx.1-2x10-(sup 1)(sup 3) at 1 second, averaging to 10-(sup 1)? at 1 day. This development shows that H-maser quality stabilities can be produced in a small clock package, comparable in size to an ultra-stable quartz oscillator required for holding 1-2x10-(sup 1)(sup 3) at 1 second. This performance was obtained in a sealed vacuum configuration where only a getter pump was used to maintain vacuum. The vacuum tube containing the traps has now been under sealed vacuum conditions for over three years with no measurable degradation of ion trapping lifetimes or clock short-term performance. We have fabricated the vacuum tube, ion trap and UV windows from materials that will allow approx. 400 deg C bake-out to prepare for tube seal-off. This approach to the vacuum follows the methods used in flight vacuum tube electronics, such as flight TWTA's where tube operation lifetime and shelf life of up to 15 years is achieved.

positioning↗