Single electrons on solid neon as a solid-state qubit platform

Progress towards the realization of quantum computers requires persistent advances in their constituent building blocks-qubits. Novel qubit platforms that simultaneously embody long coherence, fast operation and large scalability offer compelling advantages in the construction of quantum computers and many other quantum information systems 1-3 . Electrons, ubiquitous elementary particles of non-zero charge, spin and mass, have commonly been perceived as paradigmatic local quantum information carriers. Despite superior controllability and configurability, their practical performance as qubits through either motional or spin states depends critically on their material environment 3-5 . In this work, we report our experimental realization of a qubit platform based on isolated single electrons trapped on an ultraclean solid neon surface in vacuum 6-13 . By integrating an electron trap in a circuit quantum electrodynamics architecture 14-20 , we achieve strong coupling between the motional states of a single electron and a single microwave photon in an on-chip superconducting resonator. Qubit gate operations and dispersive readout are implemented to measure the energy relaxation time T 1 of 15 μs and phase coherence time T 2 over 200 ns. These results indicate that the electron-on-solid-neon qubit already performs near the state of the art for a charge qubit 21 .

36 MATERIALS SCIENCE↗

Electron Emission Observations from As-Grown and Vacuum-Coated Chemical Vapor Deposited Diamond

Field emission has been observed from chemical vapor deposited diamond grown on Mo and Si substrates. Emission was observed at fields as low as 20 kV/cm. The samples were tested in the as-grown form, and after coating with thin films of Au, CsI, and Ni. The emission current was typically maximum at the onset of the applied field, but was unstable, and decreased rapidly with time from the as-grown films. Thin Au layers, approximately 15 nm thick, vacuum deposited onto the diamond samples significantly improved the stability of the emission current at values approximately equal to those from uncoated samples at the onset of the applied field. Thin layers of CsI, approximately 5 nm thick, were also observed to improve the stability of the emission current but at values less than those from the uncoated samples at the onset of the applied field. While Au and CsI improved the stability of the emission, Ni was observed to have no effect.

Lamouri, A.↗

Synthesis and characterization of electron beam irradiation-induced damage in polycrystalline metal thin films

High-energy physics research, industrial sterilizing, and material processing depend extensively on electron beam accelerators. Exit windows are crucial components of such electron accelerator systems, maintaining vacuum integrity inside the machine while providing mechanical strength, thermal stability, and radiation resistance at the beam-target interface. In this study, thin metallic films of Ni, Ti, Cr, and V were explored for use in electron beam exit windows, and their properties were compared with the properties of their bulk counterparts. Simulation results of metal foils predicted Ti to exhibit less beam power dissipation compared to Ni. However, Ni possesses superior mechanical and structural properties compared to Ti. The performance of these films under electron beam irradiation was examined by depositing thin layers of these films on silicon and metallic substrates using magnetron sputtering and exposing them to e-beam irradiation in a controlled setup. The deposited films were subjected to a dose of approximately 66 kGy at a beam energy of 10 MeV and characterized prior to and postexposure to the beam using field emission scanning electron microscopy, atomic force microscopy, x-ray diffraction (XRD), and nanoindentation. Particular emphasis was given to characteristics like the grain structure, surface morphology, dislocation density, and hardness. XRD patterns revealed irradiation-induced changes in peak intensities, while the crystallinity remained largely unchanged. Nanoindentation results showed that the pristine and irradiated Ti and Ni films were twice as hard when compared to bulk Ti and Ni samples, regardless of the substrate type used (Si or bulk Ti, or Ni). These results emphasize the superior mechanical properties of thin metal films compared to their bulk counterparts. In conclusion, this study advances the optimization of thin film materials for robust and efficient e-beam applications, ensuring improved durability and operational reliability.

AFM↗

Generating Hyperthermal Atomic Oxygen

Atomic oxygen diffused through silver desorbed by low-energy electron impact. Oxygen atoms diffuse through silver foil and emerge on high-vacuum side, aided by electron-stimulated desorption. Atomic-oxygen flux levels range up to 10 to the 12th power cm to the negative 2 power S to the negative 1 power, and kinetic energies range from 1 to 10 eV. O positive and O negative ions swept aside by charged cylindrical grids.

Outlaw, Ronald A.↗

Towards the construction of the Mu2e electromagnetic calorimeter at Fermilab

Mu2e will search for the Charge Lepton Flavor Violating (CLFV) conversion of a muon into an electron in the field of a nucleus. A clean discovery signature is provided by the mono-energetic conversion electron (E e = 104.96 MeV). If no events are observed, Mu2e will set a limit on the ratio between the conversion and the nuclear capture rate below 3 × 10$^{-17}$ (at 90% C.L.). In order to confirm that the observed candidate is an electron, the calorimeter resolution requirements are to provide E res < 10%, T res < 500 ps for 100 MeV electrons while working in vacuum and in a high radiation environment and high magnetic field. The calorimeter is made of two annular aluminum disks, each one filled with 674 pure CsI crystals read out by SiPMs. A sophisticated mechanics and cooling system has been developed to support the crystals and cool the sensors. Radiation hard analog and fast digital electronics have been developed. In this paper the QC tests performed on the produced components and the construction status are reported, as well as the results obtained on the large size prototype with test beam data and at a cosmic ray test stand.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cleaning of contaminated channel electron multiplier arrays.

Polymerized organic materials found in vacuum systems frequently contaminate the individual channels (which can be as small as 15 microns) of an oil-pumped channel electron multiplier array used as a vacuum UV- to visible-radiation conversion device. It is shown that exposure to an oxygen plasma is an effective means of decontaminating the channels, thereby restoring the sensitivity of the device.

Harlow, F. E.↗

Full Technical Report: High-Rate Carbide Growth by Evaporation

Boron carbide (B 4 C) is an attractive inertial confined fusion (ICF) ablator and a unique ultra-hard material with numerous current and potential applications. What makes B 4 C attractive as an ablator is its relatively high density and the ability to form a stable glassy phase combined with excellent chemical and mechanical stability. Despite these advantages, the fabrication of B 4 C ablators has remained a challenge. Magnetron sputtering, our current frontrunner approach for B 4 C deposition, exhibits low deposition rates (< 2 μm/h) and undesirable nodular defects within the film structure that are believed to generate from the dusty plasma around the sputtering source. The goals of this project were to (1) establish alternative plasma-free, electron beam evaporation (EBE) capabilities for the deposition of thin films that are needed in mission-critical programs and; (2) demonstrate the feasibility to deposit B 4 C films at high rates by EBE in a bottom-up geometry and characterize their stoichiometry. In this feasibility study, we initially developed the capability to convert a general-use vacuum chamber into an electron beam evaporator as needed, or on demand. Then, we successfully used this setup to deposit films made of boron carbide and various other materials. By adjusting the deposition parameters and the evaporation source material, we were able to demonstrate the feasibility of reaching deposition rates as high as 8 μm/h, which is about 4 times the maximum rates obtained through sputtering methods. We predict that these values can still be further improved by implementing enhanced thermal control measures for the target source and optimizing electron beam parameters (ie. current, sweeping and frequency) since ceramic materials with similar densities to B 4 C can exhibit deposition rates of about twice this value. We anticipate that the skills and capabilities developed throughout this project will prove relevant not only to the HED and ICF campaigns but also to numerous existing and prospective applications focused on the development of ultra-hard carbide coatings. The fresh set of tools here developed will also facilitate the preparation and research on future new target materials of interest beyond B 4 C.

36 MATERIALS SCIENCE↗

Scanning Tunneling Microscopy methods for spectroscopic imaging of subsurface interfaces

A new method for spatially-resolved, spectroscopic investigation of subsurface interface structure has been developed. The method, Ballistic Electron Emission Microscopy (BEEM), is based on Scanning Tunneling Microscopy (STM) techniques. BEEM combines STM vacuum tunneling with unique ballistic electron spectroscopy capabilities. BEEM enables, for the first time, direct imaging of subsurface interface electronic properties with nanometer spatial resolution. STM topographic images of surface structure and BEEM images of subsurface properties are obtained simultaneously. BEEM capabilities are demonstrated by investigation of important metal-semiconductor interfaces.

Bell, L. D.↗

Generation of Terawatt Attosecond Pulses from Relativistic Transition Radiation

When a femtosecond duration and hundreds of kiloampere peak current electron beam traverses the vacuum and high-density plasma interface, a new process, that we call here relativistic transition radiation (RTR), generates an intense ~ 100 as pulse containing ~ 1 terawatt power of coherent vacuum ultraviolet (VUV) radiation accompanied by several smaller femtosecond duration satellite pulses. This pulse inherits the radial polarization of the incident beam field and has a ring intensity distribution. This RTR is emitted when the beam density is comparable to the plasma density and the spot size much larger than the plasma skin depth. Physically, it arises from the return current or backward relativistic motion of electrons starting just inside the plasma that Doppler up shifts the emitted photons. The number of RTR pulses is determined by the number of groups of plasma electrons that originate at different depths within the first plasma wake period and emit coherently before phase mixing.

43 PARTICLE ACCELERATORS↗

Space Environment Effects on Silicone Seal Materials

A docking system is being developed by the NASA to support future space missions. It is expected to use redundant elastomer seals to help contain cabin air during dockings between two spacecraft. The sealing surfaces are exposed to the space environment when vehicles are not docked. In space, the seals will be exposed to temperatures between 125 to -75 C, vacuum, atomic oxygen, particle and ultraviolet radiation, and micrometeoroid and orbital debris (MMOD). Silicone rubber is the only class of space flight-qualified elastomeric seal material that functions across the expected temperature range. NASA Glenn has tested three silicone elastomers for such seal applications: two provided by Parker (S0899-50 and S0383-70) and one from Esterline (ELA-SA-401). The effects of atomic oxygen (AO), UV and electron particle radiation, and vacuum on the properties of these three elastomers were examined. Critical seal properties such as leakage, adhesion, and compression set were measured before and after simulated space exposures. The S0899-50 silicone was determined to be inadequate for extended space seal applications due to high adhesion and intolerance to UV, but both S0383-70 and ELA-SA-401 seals were adequate.

deGroh, Henry C., III↗

Coatings for directional eutectics

Coatings developed to provide oxidation protection for the directionally-solidified eutectic alloy NiTaC-B (4.4 weight percent Cr) were evaluated. Of seven Co-, Fe- and Ni-base coatings that were initially investigated, best resistance to cyclic oxidation was demonstrated by duplex coatings fabricated by depositing a layer of NiCrAl(Y) by vacuum evaporation from an electron beam source followed by deposition of an Al overlayer using the pack cementation process. It was found that addition of carbon to the coating alloy substantially eliminated the problem of fiber denudation in TaC-type eutectic alloys. Burner rig cycled NiTaC-B samples coated with Ni-20Cr-5Al-0.1C-0.1Y+Al and rupture-tested at 1100 deg C performed as well as or better than uncoated, vacuum cycled and air-tested NiTaC-13; however, a slight degradation with respect to uncoated material was noted in air-stress rupture tests at 870 deg C for both cycled and uncycled samples.

Rairden, J. R.↗

Suprathermal electrons produced by beam-plasma-discharge

Experiments conducted with a low energy plasma lens, HARP, in the electron beam of the large vacuum chamber at Johnson Space Center indicate that an enhanced population of 50 to 300 volt electrons appear when the beam goes into the Beam-Plasma Discharge (BPD) mode. Below the BPD instability the electron distribution appears to be characterized as non-energized single particle scattering and energy loss. At 100 cm from the beam core in the BPD mode the fluxes parallel to the beam are reduced by a factor of 20 with respect to the fluxes at 25 cm. Some evidence for isotropy near the beam core is presented.

Sharp, W. E.↗

Ultraviolet spectroscopy of pressurized and supercritical carbon dioxide

Abstract Carbon dioxide (CO 2 ) is prevalent in planetary atmospheres and sees use in a variety of industrial applications. Despite its ubiquitous nature, its photochemistry remains poorly understood. In this work we explore the density dependence of pressurized and supercritical CO 2 electronic absorption spectra by vacuum ultraviolet spectroscopy over the wavelength range 1455-2000 Å. We show that the lowest absorption band transition energy is unaffected by a density increase up to and beyond the thermodynamic critical point (137 bar, 308 K). However, the diffuse vibrational structure inherent to the spectrum gradually decreases in magnitude. This effect cannot be explained solely by collisional broadening and/or dimerization. We suggest that at high densities close proximity of neighboring CO 2 molecules with a variety of orientations perturbs the multiple monomer electronic state potential energy surfaces, facilitating coupling between binding and dissociative states. We estimate a critical radius of ~4.1 Å necessary to cause such perturbations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The effect of high-energy electron radiation on poly(arylene ether)s

Thin films of four experimental poly(arylene ether)s of similar chemical structure were exposed to 1 MeV electrons while under high vacuum. The films received total exposures of 5 x 10 exp 7 and 1 x 10 exp 9 rads at a dose rate of 5 x 10 exp 7 rads/h and a pressure of 2 x 10 exp -7 torr. Films exposed to 5 x 10 exp 7 rads showed dramatic changes in molecular weight distribution. After exposures of 1 x 10 exp 9 rads the films were only partially soluble in chloroform and exhibited no detectable changes in the glass transition temperatures. Thin-film tensile properties were also altered by the exposure to electron radiation. The effect of the exposures as determined by various analyses is discussed.

Connell, J. W.↗

Laboratory observations of RF emission at plasma electron frequency and n + 1/2 times the electron cyclotron frequency in electron beam-plasma and beam-beam interactions

Electric field emissions at frequencies of (n + 1/2) times the electron cyclotron frequency have been generated in a large-scale electron beam experiment in a vacuum facility. These emissions arise when a contrastreaming beam configuration exists, the primary beam consisting of monoenergetic electrons (50 eV to 5 keV) and the other beam of lower-energy backscattered secondary electrons. It is suggested that the same mechanism could also be the source of the observed 3/2 times the electron cyclotron frequency emissions at auroral latitudes. In the absence of the beam-beam instability, weak oscillations were observed at the plasma frequency. In the latter case no significant modifications of the primary beam velocity distribution occurred, and the beam configuration is adequately described by single-particle motion in the ambient magnetic field.

Bernstein, W.↗

Photoelectron spectroscopy of CsK2Sb photocathode at Synchrotron Radiation Facility using vacuum transport system

As accelerators and electron microscopes become more advanced, high-performance photocathodes are required. In particular, Cesium potassium antimonide (CsK 2 Sb) photocathode is of interest because of its low emittance, excitability in visible light, and high quantum efficiency (QE). The challenge is its high susceptibility to environment that lead to low operating vacuum pressure and short lifetime/low extraction charge. To resolve these issues, it is necessary to understand the molecular structure of the cathode and its degradation mechanism. In this study, we transported CsK 2 Sb photocathode to a beamline of synchrotron radiation facility using a vacuum transport system for molecular structure analysis. Specifically, the cathode was deposited in an evaporation system at Nagoya University. We transported it to Aichi Synchrotron Radiation Center (Aichi SR) located 15 km away, and analyzed it in the depth direction by X-ray photoelectron spectroscopy (XPS) at BL7U. Based on the results, we quantitatively evaluated the composition ratios and stoichiometry of the cathode elements (Sb, K, Cs). A Cs ex-cess state of surface was observed at the surface, and it is consistent with previous studies. The intended atomic structure of CsK 2 Sb was formed only at a few nanometres of the surface on the Mo substrate. On the other hand, the CsK 2 Sb cathode structure on the graphene substrate was preserved further in the depth direction.

47 OTHER INSTRUMENTATION↗

Comparisons of NDT Methods to Inspect Cork and Cork filled Epoxy Bands

Sheet cork and cork filled epoxy provide external insulation for the Reusable Solid Rocket Motor (RSRM) on the Nation's Space Transportation System (STS). Interest in the reliability of the external insulation bonds has increased since the Columbia incident. A non-destructive test (NDT) method that will provide the best inspection for these bonds has been under evaluation. Electronic Shearography has been selected as the primary NDT method for inspection of these bond lines in the RSRM production flow. ATK Launch Systems Group has purchased an electronic shearography system that includes a vacuum chamber that is used for evaluation of test parts and custom vacuum windows for inspection of full-scale motors. Although the electronic shearography technology has been selected as the primary method for inspection of the external bonds, other technologies that exist continue to be investigated. The NASA/Marshall Space Flight Center (MSFC) NDT department has inspected several samples for comparison with electronic shearography with various inspections systems in their laboratory. The systems that were evaluated are X-ray backscatter, terahertz imaging, and microwave imaging. The samples tested have some programmed flaws as well as some flaws that occurred naturally during the sample making process. These samples provide sufficient flaw variation for the evaluation of the different inspection systems. This paper will describe and compare the basic functionality, test method and test results including dissection for each inspection technology.

Lingbloom, Mike↗

Means and method for calibrating a photon detector utilizing electron-photon coincidence

An arrangement for calibrating a photon detector particularly applicable for the ultraviolet and vacuum ultraviolet regions is based on electron photon coincidence utilizing crossed electron beam atom beam collisions. Atoms are excited by electrons which lose a known amount of energy and scatter with a known remaining energy, while the excited atoms emit photons of known radiation. Electrons of the known remaining energy are separated from other electrons and are counted. Photons emitted in a direction related to the particular direction of scattered electrons are detected to serve as a standard. Each of the electrons is used to initiate the measurements of a time interval which terminates with the arrival of a photon exciting the photon detector. Only the number of time intervals related to the coincidence correlation and of electrons scattered in the particular direction with the known remaining energy and photons of a particular radiation level emitted due to the collisions of such scattered electrons are counted. The detector calibration is related to the number of counted electrons and photons.

Srivastava, S. K.↗