Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “transmissive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

National Transmission Planning Study - Long-Term Modeling Results

The National Transmission Planning Study (NTP Study) analyzed the transformation needed to ensure the U.S. transmission system continues to reliably meet electricity demand as the power sector evolves. The study linked several long- and short-term power systems models to test numerous interregional and regional transmission buildout scenarios. The results included in this dataset are from the long-term capacity expansion modeling, completed with NREL's ReEDS model. This includes nearly 100 future transmission scenarios with a wide range of economic, reliability, and resilience conditions. The dataset includes all the results visualized in the Tableau Public site, as linked below.

Array↗

Updated Parameters and a New Transmission Spectrum of HD 97658b

Recent years have seen increasing interest in the characterization of sub-Neptune-sized planets because of their prevalence in the Galaxy, contrasted with their absence in our solar system. HD 97658 is one of the brightest stars hosting a planet of this kind, and we present the transmission spectrum of this planet by combining four Hubble Space Telescope transits, 12 Spitzer/IRAC transits, and eight MOST transits of this system. Our transmission spectrum has a higher signal-to-noise ratio than those from previous works, and the result suggests that the slight increase in transit depth from wavelength 1.1–1.7 μm reported in previous works on the transmission spectrum of this planet is likely systematic. Nonetheless, our atmospheric modeling results are inconclusive, as no model provides an excellent match to our data. Nonetheless, we find that atmospheres with high C/O ratios (C/O ≳ 0.8) and metallicities of ≳100× solar metallicity are favored. We combine the mid-transit times from all of the new Spitzer and MOST observations and obtain an updated orbital period of P = 9.489295 ± 0.000005, with a best-fit transit time center at T {sub 0} = 2456361.80690 ± 0.00038 (BJD). No transit timing variations are found in this system. We also present new measurements of the stellar rotation period (34 ± 2 days) and stellar activity cycle (9.6 yr) of the host star HD 97658. Finally, we calculate and rank the Transmission Spectroscopy Metric of all confirmed planets cooler than 1000 K and with sizes between 1 R {sub ⊕} and 4 R {sub ⊕}. We find that at least a third of small planets cooler than 1000 K can be well characterized using James Webb Space Telescope, and of those, HD 97658b is ranked fifth, meaning that it remains a high-priority target for atmospheric characterization.

79 ASTRONOMY AND ASTROPHYSICS↗

Two-Speed Rotorcraft Research Transmission Power-Loss Associated with the Lubrication and Hydraulic Rotating Feed-Through Design Feature

An investigation was completed into the power loss associated with a rotating feed-through (RFT) design feature used to transfer lubrication and a hydraulic control signal from the static reference frame to a rotating reference frame in the NASA GRC two-speed transmission tests conducted in the Variable-Speed Drive Test Rig. The RFT feature, not commercially available, was created specifically for this research project and is integral to all two-speed transmission configurations tested, as well as a variant concept design for a geared variable-speed transmission presented at AHS Forum 71 in 2015. The experimental set-up and results from measurements in the isolated rotating-feed-through (RFT) experiments are presented. Results were used in an overall power loss assessment for a scaled conceptual 1,000 horsepower inline concentric two-speed transmission to support a NASA Revolutionary Vertical Lift Technologies (RVLT) Technical Challenge, demonstrating 50% speed change with less than 2% power loss while maintaining current power-to-weight ratios.

Rotorcraft↗

Two-Speed Rotorcraft Research Transmission Power-Loss Associated with the Lubrication and Hydraulic Rotating Feed-Through Design Feature

An investigation was completed into the power loss associated with a rotating feed-through (RFT) design feature used to transfer lubrication and a hydraulic control signal from the static reference frame to a rotating reference frame in the NASA GRC two-speed transmission tests conducted in the Variable-Speed Drive Test Rig. The RFT feature, not commercially available, was created specifically for this research project and is integral to all two-speed transmission configurations tested, as well as a variant concept design for a geared variable-speed transmission presented at AHS Forum 71 in 2015. The experimental set-up and results from measurements in the isolated rotating-feed-through (RFT) experiments are presented. Results were used in an overall power loss assessment for a scaled conceptual 1,000 horsepower inline concentric two-speed transmission to support a NASA Revolutionary Vertical Lift Technologies (RVLT) Technical Challenge, demonstrating 50% speed change with less than 2% power loss while maintaining current power-to-weight ratios.

Rotorcraft↗

Alternating Direct Current (ADC) - A New Form of Efficient Energy Transmission for Renewable Sources

The prevailing means of electricity transmission through Direct Current (DC) and Alternating Current (AC) have limitations with the ongoing transition to renewable energy sources. In this paper, we discuss a new form of energy transmission, known as alternating direct current (ADC) that would provide significant savings in energy consumption and simultaneously allow efficient utilization of generated energy from renewable sources. This has become possible due to substantial advances in electronics and optoelectronics technologies since the days of Nicholas Tesla and Thomas Edison. Recent efforts of implementing the proposed ADC technology in relevant environments have demonstrated significant energy savings and opened a new paradigm that has the potential to provide an efficient and cost-effective pathway for transition to renewable energy sources even with the existing grid infrastructure. The DC power utilization initiated by Thomas Edison can be stored in battery arrangement but suffers from line loss and hence is not efficient for long-distance transmission. However, AC power developed by Nicholas Tesla cannot be stored efficiently but can be transmitted over long distances due to significantly lower line losses. Currently, AC power is the global foundational energy transmission methodology used because of events that took place over 135 years ago involving Edison, Tesla, and Westinghouse, and since AC power can transmit long distances from power plants to end users efficiently and economically. Approximately 50 years ago, the introduction of semiconductors in commercialized electronic devices and products changed the way people consume electricity. Also, over the years, the expanding adaptation of nonlinear loads has adversely affected the grid stability and hence the utility infrastructures worldwide.

AC↗

Combining Spectroscopic Ellipsometry with Transmission Spectroscopy to Derive Accurate Optical Constants for Organic Materials

A method for deriving the optical constants of organic powdered materials in the mid-infrared spectral range is introduced using variable angle spectroscopic ellipsometry and transmission spectroscopy. The approach uses pressed pellets of the powder and is applied to organic solids, which have both strong and weak infrared absorption features. Many powders have significant voids and do not press into smooth, homogenous pellets. To account for pellet non-idealities and to accurately measure both n and k, three different forms of pellets were pressed and measured: A pure analyte pellet, a mixed analyte/KBr pellet with a large analyte percentage, and a KBr transmission pellet with only a small analyte percentage. Using all three pellets in a multi-sample analysis involving both ellipsometric and transmission data, the complex refractive index (n/k) values can be derived for many organic compounds. This method is illustrated to calculate the optical constants for anhydrous lactose from 6000-400 cm-1. The transmission measurements improve the spectral fitting of weak absorption features, and the multi-sample analysis enables a better determination of the significant void space that is present in the pure pellet, leading to lower values for both n and k if not properly accounted for in the multi-oscillator model used to fit the ellipsometric data.

Optical constants, refractive index, extinction co↗

The oversized role of transmission in renewable integration and national security

This is a presentation for the June 1 Road to Resilience Week webinar focused on "Transmission: A National Security and Energy Resilience Imperative." Today’s electric grid cannot adequately address the national security threats it faces. Interregional HVDC transmission is a core solution to address these vulnerabilities. This webinar will focus on why we need to think about transmission as not only key for the clean energy transformation but as essential to strengthening the resilience of our electric grid. Emma Stewart, in her first speaking engagement as Chief Power Grid Scientist and Research Strategist for Idaho National Laboratory, will provide her perspective on how transmission plays an oversized role in enhancing national security and unlocking clean energy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced Transmission Technologies (ATTs) Supplier Cohort Workshops Cohort Summary [Slides]

This Summary slide deck summarizes the key outcomes of the Advanced Transmission Technologies (ATTs) supplier cohort, part of Idaho National Laboratory’s (INL) Technical Assistance for Digital Assurance (TADA) program. The program aimed to strengthen grid resilience through cybersecurity controls, supply-chain security, and Cyber-Informed Engineering (CIE) for advanced transmission technologies. The cohort brought together vendors representing the full range of Grid-Enhancing Technologies (GETs), including providers of Dynamic Line Ratings (DLR), Advanced Power Flow Control (APFC), Transmission Topology Optimization (TTO), and High-Performance Conductors (HPCs). Discussions focused on institutional, integration, and operational barriers limiting GET adoption; cybersecurity risks at EMS/SCADA, cloud, and network integration points; and supply-chain transparency issues such as semiconductor dependence and SBOM/HBOM expectations. Participants also addressed operator trust, human-in-the-loop requirements, and challenges with utility adoption, while exploring how CIE can support secure deployment of GETs. This deck represents a consolidated summary of challenges and risks identified by vendors, cross-cutting themes and technology-specific insights from three cohort workshops, and actionable mitigations to guide utilities, vendors, and the Department of Energy in advancing secure, trusted deployment of GETs.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

A Multi-Region SEIR Model Incorporating Inter-County Mobility and Time-Dependent Transmission Dynamics: Application to COVID-19 Disease Outbreak Data in North Carolina.

Classical infectious disease compartmental models typically do not incorporate spatial heterogeneity or mobility. We develop a multi-region susceptible-exposed-infected-recovered (SEIR) model in which disease dynamics are coupled via inter-region mobility and the transmission rate is both region and time dependent. We calibrate the model using rolling averages of daily COVID-19 data in all 100 North Carolina counties. Mobility parameters are prescribed using daily inter-county commuter data. The number of transmission rate parameters is substantially reduced by hypothesizing that the dynamics correlate with county-level population density. Parameter estimation is carried out using several objective functions with error terms at different scales. An additive combination of least squares error at the county-level and the state-level, along with a quadratic transmission rate polynomial, yields the lowest overall error at both spatial scales. The calibrated model is used to simulate regional effects of perturbing disease transmission rates in adjacent counties and to illustrate effects of the state’s mobility infrastructure on disease dynamics and spread for a new disease outbreak.

COVID-19 modeling↗

Transmission-distribution long-term volt-var planning considering reactive power support capability of distributed PV

High penetration of grid-edge, inverter-based photovoltaic (PV) can cause significant voltage fluctuations not only at the distribution but also at the sub-transmission levels due to PV output intermittency. Traditional reactive power planning approaches do not consider intermittency, nor the possibility of coordinating the control of existing and future volt-ampere reactive resources. This paper proposes a reactive power planning tool for sub-transmission systems to mitigate voltage violations and fluctuations caused by high PV penetration and intermittency with a minimum investment cost. The planning tool coordinates with an optimization-based volt-var operational tool for: a) modeling the coordination of all existing var assets in both sub-transmission and distribution systems to reduce the need of new equipment, and b)selecting a set of scenarios with voltage violations, derived from PV intermittency c) testing the final investment decision. The tool obtains an investment need for each intermittency scenario with a proposed optimal power-flow framework with efficient techniques to handle a high number of discrete variables. Two options are provided for final planning decision: i) a conservative direct combination of investment need solutions and ii) a machine learning-based selection of representative investment needs at most time steps. The final investment decision options are verified using a realistic large-scale sub-transmission system and 5-minute PV and load data. The results show a significant voltage performance improvement with a lower investment cost for additional var equipment compared to conventional approaches.

14 SOLAR ENERGY↗

Joint scheduling of energy, fast and primary frequency response reserves in integrated transmission–distribution networks

Inverter-based distributed energy resources (DERs) connected to distribution networks (DNs) can provide fast frequency support, but their reserve deliverability depends on feeder constraints and differs from synchronous primary frequency response (PFR). Existing transmission–distribution coordination studies usually treat reserve generically or neglect feeder-level feasibility, while frequency-security scheduling studies rarely represent distribution feeders explicitly. This paper develops a bi-level day-ahead scheduling framework for integrated transmission–distribution networks that jointly clears energy, transmission-side PFR, and distribution-side fast frequency response (FFR) under exogenous hourly inertia and largest-loss inputs from an external unit commitment (UC) schedule. The transmission problem is modeled with DC-optimal power flow (OPF) and closed-form second-order cone (SOC) frequency-security constraints, whereas each DN is represented by a reserve-aware branch-flow AC-OPF so that scheduled fast reserves remain deliverable during activation. The bi-level problem is reformulated through Karush–Kuhn–Tucker (KKT) conditions into a mixed-integer SOC program, and a penalty term is used to tighten the distribution-network relaxation. In the reduced test system, lower exogenous inertia increased the required primary response from 179.64 MW to 191.08 MW, distribution-side fast response reduced total frequency-response procurement by up to 4.9%, and neglecting distribution constraints overstated the combined distribution-side energy and reserve award by up to 18%. In the expanded study, the largest case was solved in 2.02 s with a 0.00% optimality gap. Time-domain simulations kept the frequency nadir above 59.0 Hz in all tested hours. These results demonstrate the value of fast-response modeling and distribution-feasible reserve delivery in coordinated market clearing.

Noh, Seung-Gil↗

The effect of microstructure on the relationship between grain boundary sliding and slip transmission in high purity aluminum

The relationship between grain boundary sliding (GBS) and slip transmission is investigated experimentally at grain boundaries in 99.99% aluminum with a through-thickness, coarse grained microstructure deformed in tension at 190 °C. Using scanning electron microscope enabled digital image correlation (SEM-DIC) and electron backscatter diffraction (EBSD), high resolution strain fields and microstructural information were measured to examine the influence of microstructural neighborhoods on interactions between GBS and slip transmission and strain localization. Several distinct cases are presented that highlight important microstructural factors that govern deformation near grain boundaries. The findings include (1) direct transmission and GBS were anti-compatible and facilitated by opposing boundary types (low misorientation and high energy grain boundaries respectively); (2) increased GBS activity was correlated with decreased indirect transmission behavior; (3) GBS accommodation at triple junctions was enabled by intragranular plasticity; and (4) the local intragranular plastic strain discontinuity between grains determined the magnitude of GBS gradients. Finally, this work provides insight into the nature of these mechanisms and can be used to identify strain transfer criteria that can lead to improved GBS-sensitive crystal plasticity models.

36 MATERIALS SCIENCE↗

A New Simultaneous Membrane Thickness and Catalyst Loading Measurement for Fuel Cell Proton-Exchange Assemblies by $\mathrm{IR}$ Transmission

Here, we present a study of mid-infrared (mid-IR) transmission through typical proton-exchange fuel cell and water electrolyzer catalyst-coated membrane materials, and the determination of membrane layer thickness, and catalyst layer loading, from the power of the transmitted beam. Measured membrane thicknesses lay in the range of 25-125 um, and catalyst areal loadings range from 0.05 to 0.35 mg/cm 2 . We show that the transmission spectrum correlated to membrane thickness and catalyst loading values separately, and also used a mathematical model to calculate both quantities simultaneously, from a single measurement of transmission. Measurements were carried out using a Fourier-transform infrared (FTIR) spectrometer, in specular transmission mode, in the wavelength range of 3-13 um (3333-770 cm -1 ). We discuss the potential application of this method to the development of roll-to-roll manufacturing full-area-scanning quality inspection of catalyst-coated membrane (CCM) materials.

30 DIRECT ENERGY CONVERSION↗

Scanning transmission election microscopy observations of twisted epitaxial gold nanodiscs in twisted molybdenum disulfide bilayers

Atomic scale, scanning transmission electron microscopy (STEM) analysis of the moiré structures in twisted epitaxial gold nanodiscs encapsulated in twisted bilayer molybdenum disulfide is presented. High angle annular dark field STEM imaging reveals that the period of the moiré patterns between gold and molybdenum disulfide varies with different twist angles of the bilayer molybdenum disulfide, ranging from 1.80 nm (epitaxial alignment of gold) to 1.53 nm (twisted epitaxial alignment of gold). Additionally, bright field STEM imaging reveals a faint, larger "moiré of moiré" structure in cases where the bilayer molybdenum disulfide twist angle is small (~6°), arising from the overlapping three-layers, which is not visible in conventional transmission electron microscopy images. In conclusion, our experiments indicate that scanning transmission electron microscopy as a suitable tool for moiré analysis of twisted multilayer planar heterostructures, complementary to information provided by conventional transmission electron microscopy and diffraction.

Au↗

Electric transmission value and its drivers in United States power markets

Electric transmission infrastructure plays a vital role during extreme weather and supply disruptions and can enable low-cost electricity systems. This paper contributes to a more complete understanding of the value and cost-effectiveness of transmission, as well as barriers to its development. By studying wholesale energy market prices in the United States between 2012 and 2022, we find that additional transfer capacity between regions would have been especially valuable, with a median value of $116 million per GW per year. This capacity would often have provided balanced benefits to each region. The market value of transmission was highly influenced by a small fraction of time: 5% of hours typically captured at least 45% of the total value. These peak periods were primarily driven by unforeseen changes in conditions within one day of operations. Annualized transmission infrastructure cost estimates were lower than the average market value for most locations, including all links crossing regional seams, where the value-to-cost ratio was often greater than 4. This suggests that there are barriers to developing valuable grid infrastructure. These results complement forward-looking modeling studies and support efforts to improve modeling practices.

Energy economics↗

A potent and durable malaria transmission-blocking vaccine designed from a single-component 60-copy Pfs230D1 nanoparticle

Malaria transmission-blocking vaccines (TBVs) reduce disease transmission by breaking the continuous cycle of infection between the human host and the mosquito vector. Domain 1 (D1) of Pfs230 is a leading TBV candidate and comprises the majority of transmission-reducing activity (TRA) elicited by Pfs230. Here we show that the fusion of Pfs230D1 to a 60-copy multimer of the catalytic domain of dihydrolipoyl acetyltransferase protein (E2p) results in a single-component nanoparticle composed of 60 copies of the fusion protein with high stability, homogeneity, and production yields. The nanoparticle presents a potent human transmission-blocking epitope within Pfs230D1, indicating the antigen is correctly oriented on the surface of the nanoparticle. Two vaccinations of New Zealand White rabbits with the Pfs230D1 nanoparticle elicited a potent and durable antibody response with high TRA when formulated in two distinct adjuvants suitable for translation to human use. This single-component nanoparticle vaccine may play a key role in malaria control and has the potential to improve production pipelines and the cost of manufacturing of a potent and durable TBV.

60 APPLIED LIFE SCIENCES↗

A combined designed CSP and Pfs48/45 infection and transmission blocking vaccine for malaria

Abstract The multiple stages of the malaria parasite life cycle hampers vaccine development. Combining a pre-erythrocytic antigen with a transmission-blocking antigen would target two independent stages of the life cycle for disease control, resulting in a multistage vaccine that can prevent infection and disease transmission simultaneously. Here, we generated a self-assembled ferritin nanoparticle vaccine that simultaneously presents designed immunogens CSPj5c and 17-4 from the infection-blocking circumsporozoite and the transmission-blocking Pfs48/45 antigens. These immunogens were designed, through structure-based approaches, to retain protective epitopes and confer protection upon vaccination. Immunization with CSPj5c-17-4-ferritin nanoparticles conferred protection against challenge with transgenic sporozoites expressingPlasmodium falciparumCSP in mice, and purified IgGs from immunized rabbits elicited potent transmission-reducing activity. Addition of the engineered 17-4 improved the immune responses to CSPj5c and protection from sporozoite challenge. CSPj5c-17-4-ferritin is therefore a promising multistage malaria vaccine with a potential role in malaria control.

Immunology↗

Determining the Minimum Phase‐to‐Phase Gap Distance for Unconventional Transmission Lines Using Numerical Method

With the increasing demand for power transmission, compact, high surge impedance loading (HSIL) high-voltage transmission lines have emerged as a viable solution due to their reduced land acquisition costs and higher power delivery capability. The compactness of a transmission line depends on effective insulation coordination, particularly in determining the phase-to-phase clearance, which is governed by the critical flashover voltage under switching and lightning overvoltage conditions. Traditional methods for phase-to-phase clearance rely on empirical formulas derived from experimental data, which are convenient for conventional high-voltage lines. However, unconventional HSIL lines require a faster and more adaptable evaluation method, as they involve optimized conductor positioning to reduce right-of-way requirements while enhancing natural power loadability. This study presents a simplified numerical approach to determine the minimum phase-to-phase gap, utilizing arc propagation viability curves, and offers an efficient alternative to conventional empirical methods. The proposed method was successfully applied to a 500 kV conventional line as well as 500 and 735 kV unconventional line designs, demonstrating its capability in accurately assessing insulation requirements. Results reveal that the method can support reduced gap clearances while still maintaining reliability, thereby validating its usefulness in optimizing compact transmission line configurations.

Arafat, Easir [The University of Texas at Dallas, ↗