Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “tomography problems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

A Bayesian Measurment Error Model for Misaligned Radiographic Data

An understanding of the inherent variability in micro-computed tomography (micro-CT) data is essential to tasks such as statistical process control and the validation of radiographic simulation tools. The data present unique challenges to variability analysis due to the relatively low resolution of radiographs, and also due to minor variations from run to run which can result in misalignment or magnification changes between repeated measurements of a sample. Positioning changes artificially inflate the variability of the data in ways that mask true physical phenomena. We present a novel Bayesian nonparametric regression model that incorporates both additive and multiplicative measurement error in addition to heteroscedasticity to address this problem. We also use this model to assess the effects of sample thickness and sample position on measurement variability for an aluminum specimen. Supplementary materials for this article are available online.

97 MATHEMATICS AND COMPUTING↗

Imaging properties and its improvements of scanning/imaging x-ray microscope

A scanning / imaging X-ray microscope (SIXM) system has been developed at SPring-8. The SIXM consists of a scanning X-ray microscope with a one-dimensional (1D) X-ray focusing device and an imaging (full-field) X-ray microscope with a 1D X-ray objective. The motivation of the SIXM system is to realize a quantitative and highly-sensitive multimodal 3D X-ray tomography by taking advantages of both the scanning X-ray microscope using multi-pixel detector and the imaging X-ray microscope. Data acquisition process of a 2D image is completely different between in the horizontal direction and in the vertical direction; a 1D signal is obtained with the linear-scanning while the other dimensional signal is obtained with the imaging optics. Such condition have caused a serious problem on the imaging properties that the imaging quality in the vertical direction has been much worse than that in the horizontal direction. In this paper, two approaches to solve this problem will be presented. One is introducing a Fourier transform method for phase retrieval from one phase derivative image, and the other to develop and employ a 1D diffuser to produce an asymmetrical coherent illumination.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Iatrogenic Subtotal Stenosis of the Right Subclavian Artery Treated With Percutaneous Transluminal Angioplasty

This report describes a rare vascular complication of surgical placement of a marking clip and a possible approach to problem solving. A 55-year-old patient presented with loss of sensation in the fingers and loss of peripheral pulsations in the right arm 4 days after right upper lobectomy for a pT2N1 moderately differentiated adenocarcinoma of the lung. Duplex examination and computed tomography were performed the same day and showed a subtotal stenosis of the right subclavian artery, which was caused by the surgical placement of a metal clip to mark the surgical boundary. Selective angiography was subsequently performed. Percutaneous transluminal angioplasty (PTA) successfully dilated the stenosis and pushed the clip off. Flow in the right subclavian artery (RSA) was completely restored as were neurology and peripheral pulses. In conclusion, arterial stenosis by a surgical (marking) clip may be feasibly treated with PTA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ru supported on micro and mesoporous carbons as catalysts for biomass-derived molecules hydrogenation

Supported ruthenium based materials are active for the catalytic hydrogenation of biomass-derived molecules. However, such catalysts still have problems regarding deactivation coming from Ru leaching and particles aggregation. In this work we demonstrate that spatial restriction on metal nanoparticles limits aggregation and eliminates performance losses upon subsequent testing. We synthesized and compared Ru supported on activated (Ru/AC) or mesoporous carbon (Ru/MC). Electron tomography characterization showed preferential Ru location depending on the material porosity; Ru nanoparticles were located inside mesoporous carbon pores and showed narrower size distribution. In catalytic reactions, Ru/MC reached the complete conversion of levulinic acid with the 96% selectivity to γ-valerolactone while it converted 74% of glycerol compared to the 34% showed by Ru/AC. Furthermore, we find that the Ru/AC materials deactivated after 1 catalytic cycle, however the Ru/MC maintained constant activity for multiple catalytic cycles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

2D and 3D characterization of pore defects in die cast AM60

The widespread application of die castings can be hampered due to the potential of large scale porosity to act as nucleation sites for fracture and fatigue. It is therefore important to develop robust approaches to the characterization of porosity providing parameters that can be linked to the material's mechanical properties. We have tackled this problem in a study of the AM60 die cast Mg alloy, using samples extracted from a prototype shock tower. A quantitative characterization of porosity has been undertaken, analyzing porosity in both 2D (using classical metallographic methods) and in 3D (using X-ray computed tomography (XCT)). Metallographic characterization results show that shrinkage pores and small gas pores can be distinguished based on their distinct geometrical features. Shrinkage pores are irregular with multiple arms, resulting in a form factor less than 0.4. In contrast, gas pores are generally more circular in shape yielding form factors larger than 0.6. XCT provides deeper insight into the shape of pores, although this understanding is limited by the resolution obtainable by laboratory based XCT. It also shows how 2D sectioning can produce artefacts as single complex pores are sectioned into multiple small pores. - Highlights: • Mg (e.g. AM60) die castings may contain large scale porosity that act as nucleation sites for fracture and fatigue • Quantitative characterization of porosity metallography (2D) and X-ray tomography (3D) is used • Shrinkage pores and small gas pores can be distinguished based on their distinct geometrical features. • Shrinkage pores are irregular giving a form factor < 0.4; gas pores are rounder with form factors > 0.6 • XCT enables pore visualization, although limited by the resolution obtainable by laboratory based XCT.

36 MATERIALS SCIENCE↗

Bayesian soft X-ray tomography using non-stationary Gaussian Processes

In this study, a Bayesian based non-stationary Gaussian Process (GP) method for the inference of soft X-ray emissivity distribution along with its associated uncertainties has been developed. For the investigation of equilibrium condition and fast magnetohydrodynamic behaviors in nuclear fusion plasmas, it is of importance to infer, especially in the plasma center, spatially resolved soft X-ray profiles from a limited number of noisy line integral measurements. For this ill-posed inversion problem, Bayesian probability theory can provide a posterior probability distribution over all possible solutions under given model assumptions. Specifically, the use of a non-stationary GP to model the emission allows the model to adapt to the varying length scales of the underlying diffusion process. In contrast to other conventional methods, the prior regularization is realized in a probability form which enhances the capability of uncertainty analysis, in consequence, scientists who concern the reliability of their results will benefit from it. Under the assumption of normally distributed noise, the posterior distribution evaluated at a discrete number of points becomes a multivariate normal distribution whose mean and covariance are analytically available, making inversions and calculation of uncertainty fast. Additionally, the hyper-parameters embedded in the model assumption can be optimized through a Bayesian Occam's Razor formalism and thereby automatically adjust the model complexity. This method is shown to produce convincing reconstructions and good agreements with independently calculated results from the Maximum Entropy and Equilibrium-Based Iterative Tomography Algorithm methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of today’s dual energy CT and future multi energy CT in virtual non-contrast imaging and in iodine quantification: A simulation study

Purpose: To study the performance of different dual energy computed tomography (DECT) techniques, which are available today, and future multi energy CT (MECT) employing novel photon counting detectors in an image-based material decomposition task. Methods: The material decomposition performance of different energy-resolved CT acquisition techniques is assessed and compared in a simulation study of virtual non-contrast imaging and iodine quantification. The material-specific images are obtained via a statistically optimal image-based material decomposition. A projection-based maximum likelihood approach was used for comparison with the authors’ image-based method. The different dedicated dual energy CT techniques are simulated employing realistic noise models and x-ray spectra. The authors compare dual source DECT with fast kV switching DECT and the dual layer sandwich detector DECT approach. Subsequent scanning and a subtraction method are studied as well. Further, the authors benchmark future MECT with novel photon counting detectors in a dedicated DECT application against the performance of today’s DECT using a realistic model. Additionally, possible dual source concepts employing photon counting detectors are studied. Results: The DECT comparison study shows that dual source DECT has the best performance, followed by the fast kV switching technique and the sandwich detector approach. Comparing DECT with future MECT, the authors found noticeable material image quality improvements for an ideal photon counting detector; however, a realistic detector model with multiple energy bins predicts a performance on the level of dual source DECT at 100 kV/Sn 140 kV. Employing photon counting detectors in dual source concepts can improve the performance again above the level of a single realistic photon counting detector and also above the level of dual source DECT. Conclusions: Substantial differences in the performance of today’s DECT approaches were found for the application of virtual non-contrast and iodine imaging. Future MECT with realistic photon counting detectors currently can only perform comparably to dual source DECT at 100 kV/Sn 140 kV. Dual source concepts with photon counting detectors could be a solution to this problem, promising a better performance.

60 APPLIED LIFE SCIENCES↗

X-ray microtomography

In this tutorial, we describe X-ray microtomography as a technique to nondestructively characterize material microstructure in three dimensions at a micron level spatial resolution. While commercially available laboratory scale instrumentation is available, we focus our attention on synchrotron-based systems, where we can exploit a high flux, monochromatic X-ray beam to produce high fidelity three-dimensional images. A brief description of the physics and the mathematical analysis behind the technique is followed by example applications to specific materials characterization problems, with a particular focus on the utilization of three-dimensional image processing that can be used to extract a wide range of useful information.

36 MATERIALS SCIENCE↗

Probing material nonlinearity at various depths by time reversal mirrors

In this Letter, the time reversal mirror is used to focus elastic energy at a prescribed location and to analyze the amplitude dependence of the focus signal, thus providing the nonlinearity of the medium. By varying the frequency content of the focused waveforms, the technique can be used to probe the surface, by penetrating to a depth defined by the wavelength of the focused waves. The validity of this concept is shown in the presence of gradual and distributed damage in concrete by comparing actual results with a reference nonlinear measurement and X ray tomography images.

36 MATERIALS SCIENCE↗

Experimental study of A0 Lamb wave tomography

Corrosion damage in inaccessible regions presents a significant challenge to the petrochemical industry, and determining the remaining wall thickness is important to establish the remaining service life. Guided wave tomography is one solution and involves transmitting Lamb waves through the area of interest and using the received signals to reconstruct the remaining wall thickness. This avoids the need to access all points on the surface, making the technique well suited to inspection beneath supports. For this purpose a tomography system for pipe inspections is developed using low frequency A0 Lamb waves that are excited and detected with two arrays of electromagnetic acoustic transducers (EMATs). Two different defect depths are considered with different contrasts relative to the nominal wall thickness and in a first step, the repeatability of the measurements is demonstrated. Due to the limited view array configuration, the maximum depth of the reconstruction underestimates the true depth. In a second experimental study, the influence of a pipe clamp on the thickness reconstruction is considered, representing an inspection problem with restricted access. Preliminary results have shown that the maximum defect depth is further underestimated when compared to the thickness reconstructions without the clamp. However, it is possible to detect the defect underneath the clamp for all conducted experiments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Production of medical {sup 99m}Tc isotope via photonuclear reaction

{sup 99m}Tc with a 6 hour half-life is one of the most important medical isotopes used for the Single-Photon Emission Computed Tomography (SPECT) inspection in hospitals of US, Canada, Europe and Japan. {sup 99m}Tc isotopes are extracted by the milking method from parent {sup 99}Mo isotopes with a 66 hour half-life. The supply of {sup 99}Mo isotopes now encounters a serious crisis. Hospitals may not suitably receive {sup 99}Mo medical isotopes in near future, due to difficulties in production by research nuclear reactors. Many countries are now looking for alternative ways to generate {sup 99}Mo isotopes other than those with research reactors. We discuss a sustained availability of {sup 99m}Tc isotopes via the {sup nat}Mo(γ, n) photonuclear reaction, and discuss to solve technical problems for extracting pure {sup 99m}Tc isotopes from other output materials of photonuclear reactions.

07 ISOTOPE AND RADIATION SOURCES↗

Microcracking Study of Carbon Fiber Composite Materials for Starshade Petals

We have conducted materials tests of representative carbon composite materials for starshade petals. The principal goal of these tests is to assess whether the level of microcracking of the materials as the petals are stowed or deployed (or even as they are handled during assembly) is likely to cause a problem with meeting the tight dimensional tolerances required for starlight suppression. Cracking can cause unexpected deformation, and the cracks can act as reservoirs for gases. It may also lead to roughening of the optical edge whose sharpness minimizes undesirable scattering of light. We use mechanical tests, microscopy, acoustic tomography and small‐angle x‐ray scattering to characterize the microcracking. These tests have found no large cracks (>100 microns) at bending strains up to 0.005, the strain at which audible popping occurred. The stress‐strain curves did not display any anomalies until a precipitous drop in stress at a strain of ~0.012 due to the formation of a transverse crack. Analysis of SAXS data is on‐going which will quantify microcrack distributions at the sub‐micron level. We find no large cracks (>100 microns) at the design strain tolerance for non‐critical structural elements (0.005); analysis is on‐going to quantify nanoscale cracking at the strains of critical structural elements (0.0005).

36 MATERIALS SCIENCE↗

Deep-learning-based workflow for boundary and small target segmentation in digital rock images using UNet++ and IK-EBM

We report three-dimensional (3D) X-ray micro-computed tomography (μCT) has been widely used in petroleum engineering because it can provide detailed pore structural information for a reservoir rock, which can be imported into a pore-scale numerical model to simulate the transport and distribution of multiple fluids in the pore space. The partial volume blurring (PVB) problem is a major challenge in segmenting raw μCT images of rock samples, which impacts boundaries and small targets near the resolution limit. We developed a deep-learning (DL)-based workflow for accurate and fast partial volume segmentation. The DL model's performance depends primarily on the training data quality and model architecture. This study employed the entropy-based-masking indicator kriging (IK-EBM) to segment 3D Berea sandstone images as training datasets. The comparison between IK-EBM and manual segmentation using a 3D synthetic sphere pack, which had a known ground truth, showed that IK-EBM had higher accuracy on partial volume segmentation. We then trained and tested the UNet++ model, a state-of-the-art supervised encoder-decoder model, for binary (i.e., void and solid) and four-class segmentation. We compared the UNet++ with the commonly used U-Net and wide U-Net models and showed that the UNet++ had the best performance in terms of pixel-wise and physics-based evaluation metrics. Specifically, boundary-scaled accuracy demonstrated that the UNet++ architecture outperformed the regular U-Net architecture in the segmentation of pixels near boundaries and small targets, which were subjected to the PVB effect. Feature map visualization illustrated that the UNet++ bridged the semantic gaps between the feature maps extracted at different depths of the network, thereby enabling faster convergence and more accurate extraction of fine-scale features. The developed workflow significantly enhances the performance of supervised encoder-decoder models in partial volume segmentation, which has extensive applications in fundamental studies of subsurface energy, water, and environmental systems.

02 PETROLEUM↗

Equally sloped X-ray microtomography of living insects with low radiation dose and improved resolution capability

Three-dimensional X-ray imaging of living specimens is challenging due to the limited resolution of conventional absorption contrast X-ray imaging and potential irradiation damage of biological specimens. In this letter, we present microtomography of a living specimen combining phase-contrast imaging and a Fourier-based iterative algorithm termed equally sloped tomography. Non-destructive 3D imaging of an anesthetized living yellow mealworm Tenebrio molitor was demonstrated with a relatively low dose using synchrotron generated X-rays. Based on the high-quality 3D images, branching tracheoles and different tissues of the insect in a natural state were identified and analyzed, demonstrating a significant advantage of the technique over conventional X-ray radiography or histotomy. Additionally, the insect survived without problem after a 1.92-s X-ray exposure and subsequent absorbed radiation dose of ∼1.2 Gy. No notable physiological effects were observed after reviving the insect from anesthesia. The improved static tomographic method demonstrated in this letter shows advantage in the non-destructive structural investigation of living insects in three dimensions due to the low radiation dose and high resolution capability, and offers many potential applications in biological science.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Practical and reliable error bars for quantum process tomography

Current techniques in quantum process tomography typically return a single point estimate of an unknown process based on a finite albeit large amount of measurement data. Due to statistical fluctuations, however, other processes close to the point estimate can also produce the observed data with near certainty. Unless appropriate error bars can be constructed, the point estimate does not carry any sound operational interpretation. Here, we provide a solution to this problem by constructing a confidence region estimator for quantum processes. Our method enables reliable estimation of essentially any figure of merit for quantum processes on few qubits, including the diamond distance to a specific noise model, the entanglement fidelity, and the worst-case entanglement fidelity, by identifying error regions which contain the true state with high probability. We also provide a software package, QPtomographer, implementing our estimator for the diamond norm and the worst-case entanglement fidelity. We illustrate its usage and performance with several simulated examples. Furthermore, our tools can be used to reliably certify the performance of, e.g., error correction codes, implementations of unitary gates, or more generally any noise process affecting a quantum system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Iterative Reconstruction for Multimodal Neutron Tomography

Here, we describe a unified framework for model-based iterative 3-D reconstruction of multimodal neutron transmission, hydrogen-scatter, and induced-fission images from low resolution data recorded using 14.1-MeV neutrons and the associated-particle imaging (API) technique. The framework, which was developed to facilitate use in challenging field-deployment scenarios, is centered around physics-based system models and a total variation (TV) constrained implementation of the simultaneous iterative reconstruction technique (SIRT). Modified to solve a statistically weighted least squares (WLS) problem, the SIRT algorithm is accelerated using ordered subsets and Nesterov’s momentum for which we derive a near-optimal value of the governing Lipschitz constant. The approach enables the reconstruction of images that are high resolution compared to the acquired data and is robust to both limited statistics and a limited number of projection angles. Moreover, the framework is fast enough to be practical. Example images are provided that demonstrate both the ability to perform fast-neutron imaging of high-atomic-number materials with low radiation dose and the benefit of multimodal neutron imaging to identify key materials.

Hydrogen scatter↗

Graph-learning approach to combine multiresolution seismic velocity models

SUMMARY The resolution of velocity models obtained by tomography varies due to multiple factors and variables, such as the inversion approach, ray coverage, data quality, etc. Combining velocity models with different resolutions can enable more accurate ground motion simulations. Toward this goal, we present a novel methodology to fuse multiresolution seismic velocity maps with probabilistic graphical models (PGMs). The PGMs provide segmentation results, corresponding to various velocity intervals, in seismic velocity models with different resolutions. Further, by considering physical information (such as ray path density), we introduce physics-informed probabilistic graphical models (PIPGMs). These models provide data-driven relations between subdomains with low (LR) and high (HR) resolutions. Transferring (segmented) distribution information from the HR regions enhances the details in the LR regions by solving a maximum likelihood problem with prior knowledge from HR models. When updating areas bordering HR and LR regions, a patch-scanning policy is adopted to consider local patterns and avoid sharp boundaries. To evaluate the efficacy of the proposed PGM fusion method, we tested the fusion approach on both a synthetic checkerboard model and a fault zone structure imaged from the 2019 Ridgecrest, CA, earthquake sequence. The Ridgecrest fault zone image consists of a shallow (top 1 km) high-resolution shear-wave velocity model obtained from ambient noise tomography, which is embedded into the coarser Statewide California Earthquake Center Community Velocity Model version S4.26-M01. The model efficacy is underscored by the deviation between observed and calculated traveltimes along the boundaries between HR and LR regions, 38 per cent less than obtained by conventional Gaussian interpolation. The proposed PGM fusion method can merge any gridded multiresolution velocity model, a valuable tool for computational seismology and ground motion estimation.

Geochemistry & Geophysics↗