Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “time shift”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Time-Distance Helioseismology Data-Analysis Pipeline for Helioseismic and Magnetic Imager Onboard Solar Dynamics Observatory (SDO-HMI) and Its Initial Results

The Helioseismic and Magnetic Imager onboard the Solar Dynamics Observatory (SDO/HMI) provides continuous full-disk observations of solar oscillations. We develop a data-analysis pipeline based on the time-distance helioseismology method to measure acoustic travel times using HMI Doppler-shift observations, and infer solar interior properties by inverting these measurements. The pipeline is used for routine production of near-real-time full-disk maps of subsurface wave-speed perturbations and horizontal flow velocities for depths ranging from 0 to 20 Mm, every eight hours. In addition, Carrington synoptic maps for the subsurface properties are made from these full-disk maps. The pipeline can also be used for selected target areas and time periods. We explain details of the pipeline organization and procedures, including processing of the HMI Doppler observations, measurements of the travel times, inversions, and constructions of the full-disk and synoptic maps. Some initial results from the pipeline, including full-disk flow maps, sunspot subsurface flow fields, and the interior rotation and meridional flow speeds, are presented.

Sun: helioseismology↗

Scattering of p-modes by a sunspot

The acoustic scattering properties of a large sunspot are determined from a Fourier-Hankel decomposition of p-mode amplitudes as measured from a 68-hr subset of a larger set of observations made at the South Pole in 1988. It is shown that significant improvement in the measurement of p-mode scattering amplitudes results from the increased temporal frequency resolution provided by these data. Scattering phase shifts are unambiguously determined for the first time, and the dependence of the p-mode phase shift and absorption with wavenumber and frequency is presented.

Braun, D. C.↗

Magnetic Compensation for Second-Order Doppler Shift in LITS

The uncertainty in the frequency of a linear-ion-trap frequency standard (LITS) can be reduced substantially by use of a very small magnetic inhomogeneity tailored to compensate for the residual second-order Doppler shift. An effect associated with the relativistic time dilatation, one cause of the second-order Doppler shift, is ion motion that is attributable to the trapping radio-frequency (RF)electromagnetic field used to trap ions. The second-order Doppler shift is reduced by using a multi-pole trap; however it is still the largest source of systematic frequency shift in the latest generation of LITSs, which are among the most stable clocks in the world. The present compensation scheme reduces the frequency instability of the affected LITS to about a tenth of its previous value. The basic principles of prior generation LITSs were discussed in several prior NASA Tech Briefs articles. Below are recapitulated only those items of basic information necessary to place the present development in context. A LITS includes a microwave local oscillator, the frequency of which is stabilized by comparison with the frequency of the ground state hyperfine transition of 199Hg+ ions. The comparison involves a combination of optical and microwave excitation and interrogation of the ions in a linear ion trap in the presence of a nominally uniform magnetic field. In the current version of the LITS, there are two connected traps (see figure): (1) a quadrupole trap wherein the optical excitation and measurement take place and (2) a 12-pole trap (denoted the resonance trap), wherein the microwave interrogation takes place. The ions are initially loaded into the quadrupole trap and are thereafter shuttled between the two traps. Shuttling ions into the resonance trap allows sensitive microwave interrogation to take place well away from loading interference. The axial magnetic field for the resonance trap is generated by an electric current in a finely wound wire coil surrounded by magnetic shields. In the quadrupole and 12-pole traps, the potentials are produced by RF voltages applied to even numbers (4 and 12, respectively) of parallel rods equally spaced around a circle. The polarity of the voltage on each rod is opposite that of the voltage on the adjacent rod. As a result, the amplitude of the RF trapping field is zero along the centerline and increases, with radius, to a maximum value near the rods.

Burt, Eric↗

Utilization of FSK communications for time

The method of time control at a radio station for time signal transmission using frequency shift keying, is discussed. Methods for extracting a recovered clock at the receiver are described. Results of a test involving the methods of processing time signals are presented. The requirements for adapting Precise Time and Time Interval control to a communications system are analyzed. A method for reducing the time required for synchronization or identification of messages and the fallout from the communication system to passive timekeeping users are reported.

Stone, R. R., Jr.↗

On the location of the oscillations in AE Aquarii

There is much recent interest on the nature of the oscillations in the cataclysmic variable AE Aquarii. Detected in the optical, UV, X-ray, and possibly gamma-ray bands, the origin of these 33-sec oscillations remains poorly understood; the oscillation time-delay curve is phase shifted by about 60 deg with respect to the emission-line radial velocity curve, although both should track the orbital motion of the white dwarf. We present simultaneous absorption and emission-line radial velocities, and from the absorption lines we derive an improved ephemeris. Our emission-line velocities are phase shifted by about 75 deg, and hence are unreliable tracers of the orbital motion of the white dwarf. However, the oscillation orbit is shifted by only 5 deg +/- 3 deg percent confirming that the oscillations arise from a region concentric with the white dwarf. Thus the arrival times of the oscillations yield a measure of the white dwarfs apparent orbital velocity, independent of emission-line radial velocity measurements.

Welsh, William F.↗

Upper limits on the isotropic gravitational radiation background from pulsar timing analysis

A pulsar and the earth may be thought of as end masses of a free-mass gravitational wave antenna in which the relative motion of the masses is monitored by observing the Doppler shift of the pulse arrival times. Using timing residuals from PSR 1133 + 16, 1237 + 25, 1604-00, and 2045-16, an upper limit to the spectrum of the isotropic gravitational radiation background has been derived in the frequency band 4 x 10 to the -9th to 10 to the -7th Hz. This limit is found to be S(E) = 10 to the 21st f-cubed ergs/cu cm Hz, where S(E) is the energy density spectrum and f is the frequency in Hz. This would limit the energy density at frequencies below 10 to the -8th Hz to be 0.00014 times the critical density.

Hellings, R. W.↗

Local time distribution of the SSC-associated HF-Doppler frequency shifts

The HF-Doppler frequency shift observed at the storm's sudden commencement is composed of a frequency increase (+) and decrease (-), and classified into four types, SCF(+ -), SCF(- +), SCF(+) and SCF(-). Since the latter two types are special cases of the former two types, two different kinds of electrical field exist in the F region and cause the ExB drift motion of plasma. HUANG (1976) interpreted the frequency increase of SCF(+ -) as due to the westward induction electric field proportional to delta H/ delta t and the succeeding frequency decrease due to the eastward conduction electric field which produces ionospheric currents responsible for the magnetic increase on the ground. In spite of his success in interpreting the SCF(+ -), some other interpretations are needed for the explanation of the whole set of SCF's, particularly SCF(- +). Local time distributions of the SCF's are derived from 41 SCF's which are observed on the HF standard signal (JJY) as received in Okinawa (path length =1600 km) and Kokubunji (60 km). It is shown that the SCF(+ -) appears mainly during the day, whereas the SCF(- +) is observed during the night. The results indicate that the preliminary frequency shift (+) of SCF(+ -) and (-) of SCF(- +) is caused by a westward electric field in the dayside hemisphere, while by an eastward electric field in the nightside hemisphere. The main frequency shift (-) of SCF(+ -) and (+) of SCF(- +) is caused by the reversed electric field. Consequently, the preliminary frequency shift is caused by the dusk-to-dawn electric field, while the main frequency shift by the dawn-to-dusk electric field.

Kikuchi, T.↗

A physical model for earthquakes. I - Fluctuations and interactions. II - Application to southern California

The idea that earthquakes represent a fluctuation about the long-term motion of plates is expressed mathematically through the fluctuation hypothesis, under which all physical quantities which pertain to the occurance of earthquakes are required to depend on the difference between the present state of slip on the fault and its long-term average. It is shown that under certain circumstances the model fault dynamics undergo a sudden transition from a spatially ordered, temporally disordered state to a spatially disordered, temporally ordered state, and that the latter stages are stable for long intervals of time. For long enough faults, the dynamics are evidently chaotic. The methods developed are then used to construct a detailed model for earthquake dynamics in southern California. The result is a set of slip-time histories for all the major faults, which are similar to data obtained by geological trenching studies. Although there is an element of periodicity to the events, the patterns shift, change and evolve with time. Time scales for pattern evolution seem to be of the order of a thousand years for average recurring intervals of about a hundred years.

Rundle, John B.↗

Evidence from masers for a rapidly rotating disk at the nucleus of NGC 4258

We demonstrate how maser emission from a rapidly rotating, thin Keplerian disk viewed edge-on can reproduce the general features of the observed 22 GHz radiation from the nucleus of NGC 4258, including the high-velocity satellites that are Doppler shifted by nearly +/- 1000 km/s from the central emission. Newly reported data about variations in time and space for the Doppler shifts of the central emission features fit especially well into a disk interpretation. We point out that their ratio gives a velocity of 700 km/s for the rotation at the outer edge of the masing ring -- a value that is essentially the same as the rotational velocity inferred from the Doppler shifts of the high-velocity satellites. The radius of the masing ring is 0.1 pc and the central mass at the nucleus of NGC 4258 about which the disk rotates is then 10(exp 7) solar mass.

Watson, William D.↗

Shift measurements of the stark-broadened ionized helium lines at 1640 and 1215 angstrom

Time-resolved measurements were made of the shifts of the ionized helium lines at 1,640 A (n = 3 approaches 2) and 1,215 A (n = 4 approaches 2), and of the Stark profile of the 1,215 A wavelength line. An electromagnetic shock tube was used as a light source. The plasma conditions corresponded to electron temperatures of approximately 3.5 eV and electron densities of 0.8 to 1.8 x 10 to the 17th power/cubic cm. The measured shifts fell between two previous estimates of plasma polarization shifts. The measured Stark width of the 1,215 A wavelength line was up to 30% greater than the theoretical width.

Vanzandt, J. R.↗

High-sensitivity cryogenic temperature sensors using pressurized fiber Bragg gratings

Cryogenic temperature sensing was studied using a pressurized fiber Bragg grating (PFBG). The PFBG was obtained by simply applying a small diametric load to a regular fiber Bragg grating (FBG), which was coated with polyimide of a thickness of 11 micrometers. The Bragg wavelength of the PFBG was measured at temperatures from 295 to 4.2 K. A pressure-induced transition occurred at 200 K during the cooling cycle. As a result the temperature sensitivity of the PFBG was found to be nonlinear but reach 24 pm/K below 200 K, more than three times the regular FBG. For the temperature change from 80 K to 10 K, the PFBG has a total Bragg wavelength shift of about 470 pm, 10 times more than the regular FBG. From room temperature to liquid helium temperature the PFBG gives a total wavelength shift of 3.78 nm, compared to the FBG of 1.51 nm. The effect of the coating thickness on the temperature sensitivity of the gratings is also discussed.

Wu, Meng-Chou↗

High-sensitivity Cryogenic Temperature Sensors using Pressurized Fiber Bragg Gratings

Cryogenic temperature sensing was studied using a pressurized fiber Bragg grating (PFBG). The PFBG was obtained by simply applying a small diametric load to a regular fiber Bragg grating (FBG), which was coated with polyimide of a thickness of 11 micrometers. The Bragg wavelength of the PFBG was measured at temperatures from 295 to 4.2 K. A pressure-induced transition occurred at 200 K during the cooling cycle. As a result the temperature sensitivity of the PFBG was found to be nonlinear but reach 24 pm/K below 200 K, more than three times the regular FBG. For the temperature change from 80 K to 10 K, the PFBG has a total Bragg wavelength shift of about 470 pm, 10 times more than the regular FBG. From room temperature to liquid helium temperature the PFBG gives a total wavelength shift of 3.78 nm, compared to the FBG of 1.51 nm. The effect of the coating thickness on the temperature sensitivity of the gratings is also discussed.

Wu, Meng-Chou↗

Gravitational waves and red shifts - A space experiment for testing relativistic gravity using multiple time-correlated radio signals

A two-step satellite mission for improving the accuracy of gravitational wave detection and for observing actual gravity waveforms is proposed. The spacecraft would carry both a highly stable hydrogen maser, which would control a transmitter sending signals to earth, and a Doppler transponder operating in the two-way mode. The use of simultaneous one- and two-way Doppler transmissions offers four time records of frequency pulsations, which can reveal gravitational radiation at 1-10 MHz with an amplitude accuracy of a factor of six. The first mission phase would consist of a Shuttle launch into a highly eccentric orbit to obtain measurements of the gravitational redshift using gravitational potentials of different earth regions to establish that gravity is describable by a metric theory. Then, after a boost into a heliocentric orbit at 6 AU, the earth-satellite system could detect gravitational waves in the solar system, as well as bursts emitted by the collisions of supermassive black holes.

Smarr, L. L.↗

Applied Time Domain Stability Margin Assessment for Nonlinear Time-Varying Systems

The baseline stability margins for NASA's Space Launch System (SLS) launch vehicle were generated via the classical approach of linearizing the system equations of motion and determining the gain and phase margins from the resulting frequency domain model. To improve the fidelity of the classical methods, the linear frequency domain approach can be extended by replacing static, memoryless nonlinearities with describing functions. This technique, however, does not address the time varying nature of the dynamics of a launch vehicle in flight. An alternative technique for the evaluation of the stability of the nonlinear launch vehicle dynamics along its trajectory is to incrementally adjust the gain and/or time delay in the time domain simulation until the system exhibits unstable behavior. This technique has the added benefit of providing a direct comparison between the time domain and frequency domain tools in support of simulation validation. This technique was implemented by using the Stability Aerospace Vehicle Analysis Tool (SAVANT) computer simulation to evaluate the stability of the SLS system with the Adaptive Augmenting Control (AAC) active and inactive along its ascent trajectory. The gains for which the vehicle maintains apparent time-domain stability defines the gain margins, and the time delay similarly defines the phase margin. This method of extracting the control stability margins from the time-domain simulation is relatively straightforward and the resultant margins can be compared to the linearized system results. The sections herein describe the techniques employed to extract the time-domain margins, compare the results between these nonlinear and the linear methods, and provide explanations for observed discrepancies. The SLS ascent trajectory was simulated with SAVANT and the classical linear stability margins were evaluated at one second intervals. The linear analysis was performed with the AAC algorithm disabled to attain baseline stability margins. At each time point, the system was linearized about the current operating point using Simulink's built-in solver. Each linearized system in time was evaluated for its rigid-body gain margin (high frequency gain margin), rigid-body phase margin, and aero gain margin (low frequency gain margin) for each control axis. Using the stability margins derived from the baseline linearization approach, the time domain derived stability margins were determined by executing time domain simulations in which axis-specific incremental gain and phase adjustments were made to the nominal system about the expected neutral stability point at specific flight times. The baseline stability margin time histories were used to shift the system gain to various values around the zero margin point such that a precise amount of expected gain margin was maintained throughout flight. When assessing the gain margins, the gain was applied starting at the time point under consideration, thereafter following the variation in the margin found in the linear analysis. When assessing the rigid-body phase margin, a constant time delay was applied to the system starting at the time point under consideration. If the baseline stability margins were correctly determined via the linear analysis, the time domain simulation results should contain unstable behavior at certain gain and phase values. Examples will be shown from repeated simulations with variable added gain and phase lag. Faithfulness of margins calculated from the linear analysis to the nonlinear system will be demonstrated.

Kiefer, J. M.↗

Time-intensity relations in binaural unmasking.

Variations in binaural-masked threshold of 500-cps tone masked by random noise as function of simultaneous shifts in interaural amplitude ratio and time delay of tone

AUDITORY SENSATION AREA↗

Method for neural network control of motion using real-time environmental feedback

A method of motion control for robotics and other automatically controlled machinery using a neural network controller with real-time environmental feedback. The method is illustrated with a two-finger robotic hand having proximity sensors and force sensors that provide environmental feedback signals. The neural network controller is taught to control the robotic hand through training sets using back- propagation methods. The training sets are created by recording the control signals and the feedback signal as the robotic hand or a simulation of the robotic hand is moved through a representative grasping motion. The data recorded is divided into discrete increments of time and the feedback data is shifted out of phase with the control signal data so that the feedback signal data lag one time increment behind the control signal data. The modified data is presented to the neural network controller as a training set. The time lag introduced into the data allows the neural network controller to account for the temporal component of the robotic motion. Thus trained, the neural network controlled robotic hand is able to grasp a wide variety of different objects by generalizing from the training sets.

Buckley, Theresa M.↗

Differential imaging using charge-coupled device (CCD) imagers with on-chip charge storage

A CCD technique is described which allows long integration periods between readouts together with moderate chopping rates. During each phase of a differential chopping cycle, one set of charge images is shifted to the center of the chip, which is light sensitive. At the same time, the other set of charge images is shifted under one of two masked areas which serve as charge-storage sites. Since the vertical shifting between phases can be accomplished in much less time than the typical exposure per phase, there is negligible image smearing. For a given light level and chopping rate the performance of this technique is limited primarily by the readout noise and the vertical charge transfer inefficiency. If many transfer cycles are required between readouts, the charge transfer inefficiency will diffuse the accumulated charge images along the vertical columns. Laboratory and astronomical data obtained with this technique using a CCD camera and the 2.3 m telescope on Kitt Peak are presented.

Stockman, H. S.↗