Optimizing X-ray mirror thermal performance using matched profile cooling

To cover a large photon energy range, the length of an X-ray mirror is often longer than the beam footprint length for much of the applicable energy range. To limit thermal deformation of such a water-cooled X-ray mirror, a technique using side cooling with a cooled length shorter than the beam footprint length is proposed. This cooling length can be optimized by using finite-element analysis. For the Kirkpatrick–Baez (KB) mirrors at LCLS-II, the thermal deformation can be reduced by a factor of up to 30, compared with full-length cooling. Furthermore, a second, alternative technique, based on a similar principle is presented: using a long, single-length cooling block on each side of the mirror and adding electric heaters between the cooling blocks and the mirror substrate. The electric heaters consist of a number of cells, located along the mirror length. The total effective length of the electric heater can then be adjusted by choosing which cells to energize, using electric power supplies. The residual height error can be minimized to 0.02 nm RMS by using optimal heater parameters (length and power density). Compared with a case without heaters, this residual height error is reduced by a factor of up to 45. The residual height error in the LCLS-II KB mirrors, due to free-electron laser beam heat load, can be reduced by a factor of ~11 below the requirement. The proposed techniques are also effective in reducing thermal slope errors and are, therefore, applicable to white beam mirrors in synchrotron radiation beamlines.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multiscale Modeling of Silicon Carbide Cladding for Nuclear Applications: Thermal Performance Modeling

The complex multiscale and anisotropic nature of silicon carbide (SiC) ceramic matrix composite (CMC) makes it difficult to accurately model its performance in nuclear applications. The existing models for nuclear grade composite SiC do not account for the microstructural features and how these features can affect the thermal and structural behavior of the cladding and its anisotropic properties. In addition to the microstructural features, the properties of individual constituents of the composites and fiber tow architecture determine the bulk properties. Models for determining the relationship between the individual constituents’ properties and the bulk properties of SiC composites for nuclear applications are absent, although empirical relationships exist in the literature. Here, a hierarchical multiscale modeling approach was presented to address this challenge. This modular approach addressed this difficulty by dividing the various aspects of the composite material into separate models at different length scales, with the evaluated property from the lower-length-scale model serving as an input to the higher-length-scale model. The multiscale model considered the properties of various individual constituents of the composite material (fiber, matrix, and interphase), the porosity in the matrix, the fiber volume fraction, the composite architecture, the tow thickness, etc. By considering inhomogeneous and anisotropic contributions intrinsically, our bottom-up multiscale modeling strategy is naturally physics-informed, bridging constitutive law from micromechanics to meso-mechanics and structural mechanics. The effects that these various physical attributes and thermo-physical properties have on the composite’s bulk thermal properties were easily evaluated and demonstrated through the various analyses presented herein. Since silicon carbide fiber-reinforced SiC CMCs are also promising thermal–structural materials with a broad range of high-end technology applications beyond nuclear applications, we envision that the multiscale modeling method we present here may prove helpful in future efforts to develop and construct reinforced CMCs and other advanced composite nuclear materials, such as MAX phase materials, that can service under harsh environments of ultrahigh temperatures, oxidation, corrosion, and/or irradiation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Investigation of micro-gravity effects on heat pipe thermal performance and working fluid behavior, phase B

The purpose of this experiment is to develop an in-depth understanding of the behavior of heat pipes in space. Both fixed conductance heat pipes (FCHPs) with axial grooves and variable conductance heat pipes (VCHPs) with porous wicks will be investigated. This understanding will be applied to the development of improved performance heat pipes subjected to various accelerations in space, including those encountered on a lunar base or Mars mission. More efficient, reliable, and lighter weight spacecraft thermal control systems should result from these investigations.

Gier, K. D.↗

WMAP Observatory Thermal Design and On-Orbit Thermal Performance

The Wilkinson Microwave Anisotropy Probe (WMAP) observatory, launched June 30, 2001, is designed to measure the cosmic microwave background radiation with unprecedented precision and accuracy while orbiting the second Lagrange point (L2). The instrument cold stage must be cooled passively to <95K, and systematic thermal variations in selected instrument components controlled to less than 0.5 mK (rms) per spin period. This paper describes the thermal design and testing of the WMAP spacecraft and instrument. Flight thermal data for key spacecraft and instrument components are presented from launch through the first year of mission operations. Effects of solar flux variation due to the Earth's elliptical orbit about the sun, surface thermo-optical property degradations, and solar flares on instrument thermal stability are discussed.

Glazer, Stuart D.↗

The Zero Boil-Off Tank Experiment Ground Testing and Verification of Fluid and Thermal Performance

The Zero Boil-Off Technology (ZBOT) Experiment involves performing a small scale International Space Station (ISS) experiment to study tank pressurization and pressure control in microgravity. The ZBOT experiment consists of a vacuum jacketed test tank filled with an inert fluorocarbon simulant liquid. Heaters and thermo-electric coolers are used in conjunction with an axial jet mixer flow loop to study a range of thermal conditions within the tank. The objective is to provide a high quality database of low gravity fluid motions and thermal transients which will be used to validate Computational Fluid Dynamic (CFD) modeling. This CFD can then be used in turn to predict behavior in larger systems with cryogens. This paper will discuss the work that has been done to demonstrate that the ZBOT experiment is capable of performing the functions required to produce a meaningful and accurate results, prior to its launch to the International Space Station. Main systems discussed are expected to include the thermal control system, the optical imaging system, and the tank filling system.This work is sponsored by NASAs Human Exploration Mission Directorates Physical Sciences Research program.

Fluid management↗

High Efficiency Megawatt Motor Stator Thermal Performance

Enabling single aisle electric aircraft propulsion requires power dense, megawatt scale, high efficiency electric machines. To that end NASA has been developing the High Efficiency Megawatt Motor (HEMM) 1.46 MW (16kW/kg), 98% efficient electric machine. The success of this effort is highly dependent on the stator’s thermal (cooling) design. The design to date has been based upon computation fluid dynamic and finite element analysis models that have been validated with testing of stator sub sections that replicate expected thermal conditions. However, the test to validate the model can only be so accurate without fully representing the full geometry and components of the stator. A full HEMM stator has been fabricated, potted, and installed in a housing complete with vacuum tube. This apparatus was used to validate the full thermal environment of HEMM and act as a final validation of the stator design before fully fabricating the machine. This paper discusses the modeling and test results from this penultimate HEMM stator build.

electric machine↗

Thermal performance sensitivity studies in support of material modeling for extended storage of used nuclear fuel

The work reported here is an investigation of the sensitivity of component temperatures of a storage system, including fuel cladding temperatures, in response to age-related changes that could degrade the design-basis thermal behavior of the system. The purpose of these sensitivity studies is to provide a realistic example of how changes in the physical properties or configuration of the storage system components can affect temperatures and temperature distributions. The magnitudes of these sensitivities can provide guidance for identifying appropriate modeling assumptions for thermal evaluations extending long term storage out beyond 50, 100, 200, and 300 years.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SERFE Thermal Performance Results

NASA has been developing a new spacesuit, called the Exploration Extravehicular Mobility Unit (xEMU) for over a decade. This spacesuit is underdevelopment to support missions to the International Space Station (ISS) and also to the Moon. Improvements in the life and robustness of the Portable Life Support System (PLSS) has been a major objective of these efforts. The Suit Water Membrance Evaporator (SWME) was chosen as the technology to provide cooling to the xEMU and has undergone several iterations of development over this period. An ISS flight experiment centered around the SWME and other thermal loop technologies was developed and has been under test in an ISS EXpedite PRocessing of Experiments to the Space Station (EXPRESS) rack since November of 2020. In addition to the SWME, The SWME EXPRESS Rack Flight Experiment (SERFE) contains several technology demonstrations from the xEMU project and has been demonstrating their performance in micro-gravity and over an extended duration. In addition to the SWME, these include two dissimilar water pumps, custom check valves, custom bypass relieve valves, a custom thermal control valve, development pressure and temperature sensors, and the Thermal Loop Controller. This paper presents thermal and fluids testing results of the system as a whole and of key components.

SERFE↗

Thermal performance of FRSI/graphite epoxy materials for the Orbiter TPS application

Radiant tests have been conducted to evaluate the performance of the Flexible Reusable Surface Insulation (FRSI) when bonded to Graphite/Epoxy (G/E) honeycomb sandwich structures. The results from this study indicate reasonable agreement with the baseline FRSI properties that existed prior to this test program. An updated Thermal Math Model (TMM) prediction technique was developed, with the use of the well-defined boundary conditions, which appears to be valid in analyzing the complex heat transfer associated with the honeycomb structure. The updated TM analysis of flight data resulted in good agreement of predicted temperatures with flight data for bondline responses of Orbiter FRSI/GE TPS applications.

Norman, I.↗

Thermal performance evaluation of Solar Energy Products Company (SEPCO) 'Soloron' collector tested outdoors

The test article, Model EF-212, Serial Nr. 002, is a single glazed collector with a nonselective absorber plate, using flowing air as the heat transfer medium. The absorber plate and box frame are aluminum and the insulation is one inch isocyanurate foam board with thermal conductivity of 0.11 (BTU/sq ft Hr0/ft.) The tests included the following. (1) time constant test, (2) collector efficiency test, (3) collector stagnation test, (4) incident angle modifier test, (5) load test, (6) weathering test, and (7) absorber plate optical properties test. The results of these tests are tabulated, graphed, or otherwise recorded.

Chiou, J., Sr.↗