Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “testing statistics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Empirical investigation of nuclear correlation function distributions in lattice QCD

Two-point correlation functions of systems with baryon number 𝐵 ∈ {1,2,3,4} are investigated using lattice quantum chromodynamics (QCD). In particular, the empirical distributions of importance-sampling Monte-Carlo samples of these correlation functions are examined as a function of the spacetime separation between the two points and the baryon number. While the exact forms of these distributions are not known for QCD, recent work has determined asymptotic expressions for analogous correlation function distributions in simpler theories such as scalar field theory and the disordered phase of the 𝑂⁡(𝑁) model. The theoretical 𝑂⁡(𝑁) model distributions are found to provide an accurate description of the empirical QCD distributions at zero momentum over a wide range of temporal separations for each baryon number when assessed with a range of different statistical tests. In particular, the behavior of the baryon number 𝐵 QCD correlation function at large temporal separation is well reproduced by the 𝑂⁡(𝑁 ∼ 2/𝐵) model distribution.

Lattice field theory↗

Quantum random-number generator based on a photon-number-resolving detector

We demonstrated a high-efficiency quantum random number generator which takes inherent advantage of the photon number distribution randomness of a coherent light source. This scheme was realized by comparing the photon flux of consecutive pulses with a photon number resolving detector. The random bit generation rate could reach 2.4 MHz with a system clock of 6.0 MHz, corresponding to a random bit generation efficiency as high as 40%. The random number files passed all the stringent statistical tests.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Integer ratios of S{sub n}/E{sub n} in {sup 40}Ca+n resonances suggesting two-oscillator excitations in the target nucleus

In s-wave neutron resonances of {sup 40}Ca at E{sub n}{<=}2.5 MeV, S{sub n}/E{sub n} for many levels is found to be of the form 17(n/m) where n, m are small integers. Statistical tests show small probabilities for the observed dispositions of many levels at E{sub n}=(j/k)(1/70)G (j, k; small integers). To meet the requirement of time periodicity of the compound nucleus at resonance, a breathing model is developed, where the excitation energies E{sub x} are written as a sum of inverse integers; E{sub x}=S{sub n}+E{sub n}=G{sigma}(1/k) (k: integer). In {sup 40}Ca+n, the separation energy S{sub n}=8362 keV is written as S{sub n}=(17/70)G=(1/7+1/10)G, where G=34.4 MeV. G is almost equal to the Fermi energy of the nucleus. It is suggested that two oscillators of energy (1/7)G and (1/10)G are excited in {sup 40}Ca by neutron incidence, in which the recurrence energy (1/70)G is resonant with neutrons of energies at (j/k)(1/70)G, forming a simple compound nucleus.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Learning new physics from data: A symmetrized approach

Thousands of person years have been invested in searches for new physics (NP), the majority of them motivated by theoretical considerations. Yet, no evidence of beyond the Standard Model physics has been found. This suggests that model-agnostic searches might be an important key to explore NP, and help discover unexpected phenomena which can inspire future theoretical developments. A possible strategy for such searches is identifying asymmetries between data samples that are expected to be symmetric within the Standard Model. We propose exploiting neural networks (NNs) to quickly fit and statistically test the differences between two samples. Our method is based on an earlier work, originally designed for inferring the deviations of an observed dataset from that of a much larger reference dataset. We present a symmetric formalism, generalizing the original one, avoiding fine-tuning of the NN parameters and any constraints on the relative sizes of the samples. Our formalism could be used to detect small symmetry violations, extending the discovery potential of current and future particle physics experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Hubble expansion and structure formation in time varying vacuum models

We investigate the properties of the FLRW flat cosmological models in which the vacuum energy density evolves with time, {lambda}(t). Using different versions of the {lambda}(t) model, namely, quantum field vacuum, power series vacuum and power law vacuum, we find that the main cosmological functions such as the scale factor of the Universe, the Hubble expansion rate H, and the energy densities are defined analytically. Performing a joint likelihood analysis of the recent supernovae type Ia data, the cosmic microwave background shift parameter and the baryonic acoustic oscillations traced by the Sloan Digital Sky Survey galaxies, we put tight constraints on the main cosmological parameters of the {lambda}(t) scenarios. Furthermore, we study the linear matter fluctuation field of the above vacuum models. We find that the patterns of the power series vacuum {lambda}=n{sub 1}H+n{sub 2}H{sup 2} predict stronger small scale dynamics, which implies a faster growth rate of perturbations with respect to the other two vacuum cases (quantum field and power law), despite the fact that all the cosmological models share the same equation of state parameter. In the case of the quantum field vacuum {lambda}=n{sub 0}+n{sub 2}H{sup 2}, the corresponding matter fluctuation field resembles that of the traditional {lambda} cosmology. The power law vacuum ({lambda}{proportional_to}a{sup -n}) mimics the classical quintessence cosmology, the best fit being tilted in the phantom phase. In this framework, we compare the observed growth rate of clustering measured from the optical galaxies with those predicted by the current {lambda}(t) models. Performing a Kolmogorov-Smirnov statistical test we show that the cosmological models which contain a constant vacuum ({lambda}CDM), quantum field vacuum, and power law vacuum provide growth rates that match well with the observed growth rate. However, this is not the case for the power series vacuum models (in particular, the frequently adduced {lambda}{proportional_to}H model) in which clusters form at significantly earlier times (z{>=}4) with respect to all other models (z{approx}2). Finally, we derived the theoretically predicted dark matter halo mass function and the corresponding distribution of cluster-size halos for all the models studied. Their expected redshift distribution indicates that it will be difficult to distinguish the closely resembling models (constant vacuum, quantum field, and power law vacuum), using realistic future x-ray surveys of cluster abundances. However, cluster surveys based on the Sunayev-Zeldovich detection method give some hope to distinguish the closely resembling models at high redshifts.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Calibration, event reconstruction, data analysis, and limit calculation for the LUX dark matter experiment

Here, the LUX experiment has performed searches for dark matter particles scattering elastically on xenon nuclei, leading to stringent upper limits on the nuclear scattering cross sections for dark matter. Here, for results derived from ${1.4}\times 10^{4}\;\mathrm{kg\,days}$ of target exposure in 2013, details of the calibration, event-reconstruction, modeling, and statistical tests that underlie the results are presented. Detector performance is characterized, including measured efficiencies, stability of response, position resolution, and discrimination between electron- and nuclear-recoil populations. Models are developed for the drift field, optical properties, background populations, the electron- and nuclear-recoil responses, and the absolute rate of low-energy background events. Innovations in the analysis include in situ measurement of the photomultipliers' response to xenon scintillation photons, verification of fiducial mass with a low-energy internal calibration source, and new empirical models for low-energy signal yield based on large-sample, in situ calibrations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Kaon Photoproduction and the Λ Decay Parameter α –

The weak decay parameter $\alpha_-$ of the $\Lambda$ is an important quantity for the extraction of polarization observables in various experiments. Moreover, in combination with $\alpha_+$ from $\bar\Lambda$ decay it provides a measure for matter-antimatter asymmetry. The weak decay parameter also affects the decay parameters of the $\Xi$ and $\Omega$ baryons and, in general, any quantity in which the polarization of the $\Lambda$ is relevant. The recently reported value by the BESIII collaboration of $0.750(9)(4)$ is significantly larger than the previous PDG value of $0.642(13)$ that had been accepted and used for over 40 years. In this work we make an independent estimate of $\alpha_-$, using an extensive set of polarization data measured in kaon photoproduction in the baryon resonance region and constraints set by spin algebra. The obtained value is 0.721(6)(5). The result is corroborated by multiple statistical tests as well as a modern phenomenological model, showing that our new value yields the best description of the data in question. Furthermore, our analysis supports the new BESIII finding that $\alpha_-$ is significantly larger than the previous PDG value. Any experimental quantity relying on the value of $\alpha_-$ should therefore be re-considered.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First Leptophobic Dark Matter Search from the Coherent–CAPTAIN-Mills Liquid Argon Detector

We report the first results of a search for leptophobic dark matter (DM) from the Coherent–CAPTAIN-Mills (CCM) liquid argon (LAr) detector. An engineering run with 120 photomultiplier tubes (PMTs) and 17.9 × 10 20 protons on target (POT) was performed in fall 2019 to study the characteristics of the CCM detector. The operation of this 10-ton detector was strictly light based with a threshold of 50 keV and used coherent elastic scattering off argon nuclei to detect DM. Despite only 1.5 months of accumulated luminosity, contaminated LAr, and nonoptimized shielding, CCM’s first engineering run has already achieved sensitivity to previously unexplored parameter space of light dark matter models with a baryonic vector portal. With an expected background of 115 005 events, we observe 115 005 + 16.5 events which is compatible with background expectations. For a benchmark mediator-to-DM mass ratio of m V B =m χ = 2.1, DM masses within the range 9 MeV ≲ m χ ≲ 50 MeV are excluded at 90% C. L. in the leptophobic model after applying the Feldman-Cousins test statistic. CCM’s upgraded run with 200 PMTs, filtered LAr, improved shielding, and 10 times more POT will be able to exclude the remaining thermal relic density parameter space of this model, as well as probe new parameter space of other leptophobic DM models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Confidence intervals for fitting of atomic models into low-resolution densities

This paper describes procedures for obtaining confidence intervals for coordinate locations resulting from the fitting of atomic models into low-resolution densities. The fitting of high-resolution structures into low-resolution densities obtained from techniques such as electron microscopy or small-angle X-ray scattering can yield powerful new insights. While several algorithms for achieving optimal fits have recently been developed, relatively little effort has been devoted to developing objective measures for judging the quality of the resulting fits, in particular with regard to the danger of overfitting. Here, a general method is presented for obtaining confidence intervals for atomic coordinates resulting from fitting of atomic resolution domain structures into low-resolution densities using well established statistical tools. It is demonstrated that the resulting confidence intervals are sufficiently accurate to allow meaningful statistical tests and to provide tools for detecting potential overfitting.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Healing X-ray scattering images

X-ray scattering images contain numerous gaps and defects arising from detector limitations and experimental configuration. Here, we present a method to heal X-ray scattering images, filling gaps in the data and removing defects in a physically meaningful manner. Unlike generic inpainting methods, this method is closely tuned to the expected structure of reciprocal-space data. In particular, we exploit statistical tests and symmetry analysis to identify the structure of an image; we then copy, average and interpolate measured data into gaps in a way that respects the identified structure and symmetry. Importantly, the underlying analysis methods provide useful characterization of structures present in the image, including the identification of diffuse versus sharp features, anisotropy and symmetry. The presented method leverages known characteristics of reciprocal space, enabling physically reasonable reconstruction even with large image gaps. The method will correspondingly fail for images that violate these underlying assumptions. The method assumes point symmetry and is thus applicable to small-angle X-ray scattering (SAXS) data, but only to a subset of wide-angle data. Our method succeeds in filling gaps and healing defects in experimental images, including extending data beyond the original detector borders.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Detection of Cyber Attacks in Grid-tied PV Systems Using Dynamic Watermarking

This paper presents of an active detection scheme for detecting cyber attacks on sensors controlling a grid-tied PV systems. Several cyber vulnerabilities in Grid tied PV Systems are discussed. The defense mechanism introduces a private (secret) watermarking signal into the control inputs of the grid-tied inverter system. This will enable the detection of any malicious manipulation of sensor measurements. Based on the measured data, two statistical tests are conducted to identify anomalies in the system using the presence of the watermarking signal. It shown that when a sensor data is compromised and/or replaced by a pre-recorded healthy signal, both test 1 and 2 exhibit high values indicating a possible malicious activity. The robustness of the proposed algorithm is tested and validated with several attack scenarios on a grid tied PV system. Select results from an experimental setup are discussed.

Ibrahim, Hasan↗

Leveraging High-Fidelity Datasets for Machine Learning-based Anomaly Detection in Smart Grids

Data-driven intrusion detection systems are increasingly becoming essential for protecting critical cyber-physical infrastructure, such as the power grid, against the growing number of sophisticated cyber-attacks. The development of such tools is reliant on the availability of high-fidelity cyber-physical datasets that cover a diverse variety of potential cyber events. In this work, a high-fidelity smart grid platform is utilized to develop an extensive dataset, which is used to train and test a machine learning-based intrusion detection system. The evaluation of the developed IDS shows robust performance even when tested with statistically diverse test data not used in training.

Hyder, Burhan↗

Evaluating Synthetic Smart Meter Locations For Communication System Modeling

An important part of good communication models for smart grid applications, particularly when wireless protocols are used, is the location information of the nodes. We’ve developed metrics to assist in evaluating whether a given model with such information is representative of feeders found in the world. These metrics are applied to a set of feeder models with known good location information for the smart meter locations and compared to a set of feeder models with similar location information that is not expected to be representative of real-world feeders. The comparison reveals that the suspect models do not pass statistical tests utilizing the developed metrics, providing initial validation of the analysis technique.

smart meter, feeder model, GridLAB-D↗

Complex interactions between day length and diurnal patterns of gene expression drive photoperiodic responses in a perennial C 4 grass

Abstract Photoperiod is a key environmental cue affecting flowering and biomass traits in plants. Key components of the photoperiodic flowering pathway have been identified in many species, but surprisingly few studies have globally examined the diurnal rhythm of gene expression with changes in day length. Using a cost‐effective 3′‐Tag RNA sequencing strategy, we characterize 9,010 photoperiod responsive genes with strict statistical testing across a diurnal time series in the C 4 perennial grass, Panicum hallii . We show that the vast majority of photoperiod responses are driven by complex interactions between day length and sampling periods. A fine‐scale contrast analysis at each sampling time revealed a detailed picture of the temporal reprogramming of cis ‐regulatory elements and biological processes under short‐ and long‐day conditions. Phase shift analysis reveals quantitative variation among genes with photoperiod‐dependent diurnal patterns. In addition, we identify three photoperiod enriched transcription factor families with key genes involved in photoperiod flowering regulatory networks. Finally, coexpression networks analysis of GIGANTEA homolog predicted 1,668 potential coincidence partners, including five well‐known GI‐interacting proteins. Our results not only provide a resource for understanding the mechanisms of photoperiod regulation in perennial grasses but also lay a foundation to increase biomass yield in biofuel crops.

Weng, Xiaoyu↗

A Bayesian nonparametric analysis for zero-inflated multivariate count data with application to microbiome study

High-throughput sequencing technology has enabled researchers to profile microbial communities from a variety of environments, but analysis of multivariate taxon count data remains challenging. Here, we develop a Bayesian nonparametric (BNP) regression model with zero inflation to analyse multivariate count data from microbiome studies. A BNP approach flexibly models microbial associations with covariates, such as environmental factors and clinical characteristics. The model produces estimates for probability distributions which relate microbial diversity and differential abundance to covariates, and facilitates community comparisons beyond those provided by simple statistical tests. We compare the model to simpler models and popular alternatives in simulation studies, showing, in addition to these additional community-level insights, it yields superior parameter estimates and model fit in various settings. The model's utility is demonstrated by applying it to a chronic wound microbiome data set and a Human Microbiome Project data set, where it is used to compare microbial communities present in different environments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An analysis of tolerance levels in IMRT quality assurance procedures

Increased use of intensity modulated radiation therapy (IMRT) has resulted in increased efforts in patient quality assurance (QA). Software and detector systems intended to streamline the IMRT quality assurance process often report metrics, such as percent discrepancies between measured and computed doses, which can be compared to benchmark or threshold values. The purpose of this work is to examine the relationships between two different types of IMRT QA processes in order to define, or refine, appropriate tolerances values. For 115 IMRT plans delivered in a 3 month period, we examine the discrepancies between (a) the treatment planning system (TPS) and results from a commercial independent monitor unit (MU) calculation program; (b) TPS and results from a commercial diode-array measurement system; and (c) the independent MU calculation and the diode-array measurements. Statistical tests were performed to assess significance in the IMRT QA results for different disease site and machine models. There is no evidence that the average total dose discrepancy in the monitor unit calculation depends on the disease site. Second, the discrepancies in the two IMRT QA methods are independent: there is no evidence that a better --or worse--monitor unit validation result is related to a better--or worse--diode-array measurement result. Third, there is marginal benefit in repeating the independent MU calculation with a more suitable dose point, if the initial IMRT QA failed a certain tolerance. Based on these findings, the authors conclude at some acceptable tolerances based on disease site and IMRT QA method. Specifically, monitor unit validations are expected to have a total dose discrepancy of 3% overall, and 5% per beam, independent of disease site. Diode array measurements are expected to have a total absolute dose discrepancy of 3% overall, and 3% per beam, independent of disease site. The percent of pixels exceeding a 3% and 3 mm threshold in a gamma analysis should be greater than or equal to 95% for non-head and neck IMRT cases, and 88% for head and neck IMRT cases. The IMRT QA methodology described here is neither unique nor ubiquitous, and the ability to deliver a safe IMRT does not simply require IMRT QA tests to pass a given tolerance; however, the selection of a tolerance should be meaningful when assessing a complex plan. The methodology in defining appropriate tolerances, described in this article, is based on an interpretation of IMRT QA results from IMRT plans deemed safe to deliver.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of GEANT4 very low energy cross section models with experimental data in water

Purpose: The GEANT4 general-purpose Monte Carlo simulation toolkit is able to simulate physical interaction processes of electrons, hydrogen and helium atoms with charge states (H{sup 0}, H{sup +}) and (He{sup 0}, He{sup +}, He{sup 2+}), respectively, in liquid water, the main component of biological systems, down to the electron volt regime and the submicrometer scale, providing GEANT4 users with the so-called ''GEANT4-DNA'' physics models suitable for microdosimetry simulation applications. The corresponding software has been recently re-engineered in order to provide GEANT4 users with a coherent and unique approach to the simulation of electromagnetic interactions within the GEANT4 toolkit framework (since GEANT4 version 9.3 beta). This work presents a quantitative comparison of these physics models with a collection of experimental data in water collected from the literature. Methods: An evaluation of the closeness between the total and differential cross section models available in the GEANT4 toolkit for microdosimetry and experimental reference data is performed using a dedicated statistical toolkit that includes the Kolmogorov-Smirnov statistical test. The authors used experimental data acquired in water vapor as direct measurements in the liquid phase are not yet available in the literature. Comparisons with several recommendations are also presented. Results: The authors have assessed the compatibility of experimental data with GEANT4 microdosimetry models by means of quantitative methods. The results show that microdosimetric measurements in liquid water are necessary to assess quantitatively the validity of the software implementation for the liquid water phase. Nevertheless, a comparison with existing experimental data in water vapor provides a qualitative appreciation of the plausibility of the simulation models. The existing reference data themselves should undergo a critical interpretation and selection, as some of the series exhibit significant deviations from each other. Conclusions: The GEANT4-DNA physics models available in the GEANT4 toolkit have been compared in this article to available experimental data in the water vapor phase as well as to several published recommendations on the mass stopping power. These models represent a first step in the extension of the GEANT4 Monte Carlo toolkit to the simulation of biological effects of ionizing radiation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Tomotherapy treatment plan quality assurance: The impact of applied criteria on passing rate in gamma index method

Purpose: Pretreatment patient plan verification with gamma index (GI) metric analysis is standard procedure for intensity modulated radiation therapy (IMRT) treatment. The aim of this paper is to evaluate the variability of the local and global gamma index obtained during standard pretreatment quality assurance (QA) measurements for plans performed with Tomotherapy unit. The QA measurements were performed with a 3D diode array, using variable passing criteria: 3%/3 mm, 2%/2 mm, 1%/1 mm, each with both local and global normalization.Methods: The authors analyzed the pretreatment QA results for 73 verifications; 37 were prostate cancer plans, 16 were head and neck plans, and 20 were other clinical sites. All plans were treated using the Tomotherapy Hi-Art System. Pretreatment QA plans were performed with the commercially available 3D diode array ArcCHECK™. This device has 1386 diodes arranged in a helical geometry spaced 1 cm apart. The dose measurements were acquired on the ArcCHECK™ and then compared with the calculated dose using the standard gamma analysis method. The gamma passing rate (%GP), defined as the percentage of points satisfying the condition GI < 1, was calculated for different criteria (3%/3 mm, 2%/2 mm, 1%/1 mm) and for both global and local normalization. In the case of local normalization method, the authors set three dose difference threshold (DDT) values of 2, 3, and 5 cGy. Dose difference threshold is defined as the minimum absolute dose error considered in the analysis when using local normalization. Low-dose thresholds (TH) of 5% and 10% were also applied and analyzed.Results: Performing a paired-t-test, the authors determined that the gamma passing rate is independent of the threshold values for all of the adopted criteria (5%TH vs 10%TH, p > 0.1). Our findings showed that mean %GPs for local (or global) normalization for the entire study group were 93% (98%), 84% (92%), and 66% (61%) for 3%/3 mm, 2%/2 mm, and 1%/1 mm criteria, respectively. DDT was equal to 2 cGy for the local normalization analysis cases. The authors observed great variability in the resulting %GP. With 3%/3 mm gamma criteria, the overall passing rate with local normalization was 4.6% less on the average than with global one, as expected. The wide difference between %GP calculated with global or local approach is also confirmed by an unpaired t-test statistical analysis.Conclusions: The variability of %GP obtained confirmed the necessity to establish defined agreement criteria that could be universal and comparable between institutions. In particular, while the gamma passing rate does not depend on the choice of threshold, the choice of DDT strongly influences the gamma passing rate for local calculations. The difference between global and local %GP was statistically significant for prostate and other treatment sites when DDT was changed from 2 to 3 cGy.

61 RADIATION PROTECTION AND DOSIMETRY↗