Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “systematic errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Accuracy of Ultrasound-Based Image Guidance for Daily Positioning of the Upper Abdomen: An Online Comparison With Cone Beam CT

Purpose: Image-guided intensity-modulated radiotherapy can improve protection of organs at risk when large abdominal target volumes are irradiated. We estimated the daily positioning accuracy of ultrasound-based image guidance for abdominal target volumes by a direct comparison of daily imaging obtained with cone beam computed tomography (CBCT). Methods and Materials: Daily positioning (n = 83 positionings) of 15 patients was completed by using ultrasound guidance after an initial CBCT was obtained. Residual error after ultrasound was estimated by comparison with a second CBCT. Ultrasound image quality was visually rated using a scale of 1 to 4. Results: Of 15 patients, 7 patients had good sonographic imaging quality, 5 patients had satisfactory sonographic quality, and 3 patients were excluded because of unsatisfactory sonographic quality. When image quality was good, residual errors after ultrasound were -0.1 {+-} 3.11 mm in the x direction (left-right; group systematic error M = -0.09 mm; standard deviation [SD] of systematic error, {sigma} = 1.37 mm; SD of the random error, {sigma} = 2.99 mm), 0.93 {+-} 4.31 mm in the y direction (superior-inferior, M = 1.12 mm; {sigma} = 2.96 mm; {sigma} = 3.39 mm), and 0.71 {+-} 3.15 mm in the z direction (anteroposterior; M = 1.01 mm; {sigma} = 2.46 mm; {sigma} = 2.24 mm). For patients with satisfactory image quality, residual error after ultrasound was -0.6 {+-} 5.26 mm in the x (M = 0.07 mm; {sigma} = 5.67 mm; {sigma} = 4.86 mm), 1.76 {+-} 4.92 mm in the y (M = 3.54 mm; {sigma} = 4.1 mm; {sigma} = 5.29 mm), and 1.19 {+-} 4.75 mm in the z (M = 0.82 mm; {sigma} = 2.86 mm; {sigma} = 3.05 mm) directions. Conclusions: In patients from whom good sonographic image quality could be obtained, ultrasound improved daily positioning accuracy. In the case of satisfactory image quality, ultrasound guidance improved accuracy compared to that of skin marks only minimally. If sonographic image quality was unsatisfactory, daily CBCT scanning improved treatment accuracy distinctly over that of ultrasound. Use of daily ultrasound or CBCT imaging can help to reduce PTV margins and protect organs at risk compared to the use of skin mark-based positioning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Error Distribution of BATSE GRB Location

We develop empirical probability models for BATSE GRB location errors by a Bayesian analysis of the separations between BATSE GRB locations and locations obtained with the InterPlanetary Network (IPN). Models are compared and their parameters estimated using 394 GRBs with single IPN annuli and 20 GRBs with intersecting IPN annuli. Most of the analysis is for the 4B (rev) BATSE catalog; earlier catalogs are also analyzed. The simplest model that provides a good representation of the error distribution has 78% of the locations in a 'core' term with a systematic error of 1.85 degrees and the remainder in an extended tail with a systematic error of 5.36 degrees, implying a 68% confidence region for bursts with negligible statistical errors of 2.3 degrees. There is some evidence for a more complicated model in which the error distribution depends on the BATSE datatype that was used to obtain the location. Bright bursts are typically located using the CONT datatype, and according to the more complicated model, the 68% confidence region for CONT-located bursts with negligible statistical errors is 2.0 degrees.

Briggs, Michael S.↗

The Error Distribution of BATSE Gamma-Ray Burst Locations

Empirical probability models for BATSE gamma-ray burst (GRB) location errors are developed via a Bayesian analysis of the separations between BATSE GRB locations and locations obtained with the Interplanetary Network (IPN). Models are compared and their parameters estimated using 392 GRBs with single IPN annuli and 19 GRBs with intersecting IPN annuli. Most of the analysis is for the 4Br BATSE catalog; earlier catalogs are also analyzed. The simplest model that provides a good representation of the error distribution has 78% of the probability in a "core" term with a systematic error of 1.85 deg and the remainder in an extended tail with a systematic error of 5.1 deg, which implies a 68% confidence radius for bursts with negligible statistical uncertainties of 2.2 deg. There is evidence for a more complicated model in which the error distribution depends on the BATSE data type that was used to obtain the location. Bright bursts are typically located using the CONT data type, and according to the more complicated model, the 68% confidence radius for CONT-located bursts with negligible statistical uncertainties is 2.0 deg.

Briggs, Michael S.↗

Simple model to investigate jet quenching and correlated errors for centrality-dependent nuclear modification factors in relativistic heavy-ion collisions

Here, we apply Bayesian techniques to compare a simple, empirical model for jet quenching in heavy-ion collisions to centrality-dependent jet R AA measured by ATLAS for Pb + Pb collisions at $\sqrt{s_{NN}}$ = 5.02 TeV. We find that the R AA values for central collisions are adequately described with a model for the mean p T -dependent jet energy loss using only two parameters. This model is extended by incorporating two-dimensional initial geometry information from TRENTo and compared to centrality-dependent R AA values. We find that the results are sensitive to the value of the jet-quenching formation time, τ ƒ , and that the optimal value of τ ƒ varies with the assumed path-length dependence of the energy loss. We construct a covariance error matrix for the data from the p T -dependent contributions to the ATLAS systematic errors and perform Bayesian calibrations for several different assumptions for the systematic error correlations. We show that the most-probable functions and $χ^2_d$ values are sensitive to assumptions made when fitting to correlated errors. This work demonstrates the utility of a simple model that can quickly demonstrate the constraining power of jet-quenching observables with corresponding uncertainties and guide future studies using more sophisticated models.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

THE ARAUCARIA PROJECT: FIRST CEPHEID DISTANCE TO THE SCULPTOR GROUP GALAXY NGC 7793 FROM VARIABLES DISCOVERED IN A WIDE-FIELD IMAGING SURVEY

For the first time, we have detected Cepheid variables in the Sculptor Group spiral galaxy NGC 7793. From wide-field images obtained in the optical V and I bands on 56 nights in 2003-2005, we have discovered 17 long-period (24-62 days) Cepheids whose periods and mean magnitudes define tight period-luminosity relations. We use the (V - I) Wesenheit index to determine a reddening-free true distance modulus to NGC 7793 of 27.68 {+-} 0.05 mag (internal error) {+-} 0.08 mag (systematic error). The comparison of the reddened distance moduli in V and I with the one derived from the Wesenheit magnitude indicates that the Cepheids in NGC 7793 are affected by an average total reddening of E(B - V) = 0.08 mag, 0.06 of which is produced inside the host galaxy. As in the earlier Cepheid studies of the Araucaria Project, the reported distance is tied to an assumed LMC distance modulus of 18.50. The quoted systematic uncertainty takes into account effects like blending and possible inhomogeneous filling of the Cepheid instability strip on the derived distance. The reported distance value does not depend on the (unknown) metallicity of the Cepheids according to recent theoretical and empirical results. Our Cepheid distance is shorter, but within the errors consistent with the distance to NGC 7793 determined earlier with the TRGB and Tully-Fisher methods. The NGC 7793 distance of 3.4 Mpc is almost identical to the one our project had found for NGC 247, another spiral member of the Sculptor Group located close to NGC 7793 on the sky. Two other conspicuous spiral galaxies in the Sculptor Group, NGC 55 and NGC 300, are much nearer (1.9 Mpc), confirming the picture of a very elongated structure of the Sculptor Group in the line of sight put forward by Jerjen et al. and others.

79 ASTRONOMY AND ASTROPHYSICS↗

Effect of Image-Guidance Frequency on Geometric Accuracy and Setup Margins in Radiotherapy for Locally Advanced Lung Cancer

Purpose: To assess the relative effectiveness of five image-guidance (IG) frequencies on reducing patient positioning inaccuracies and setup margins for locally advanced lung cancer patients. Methods and Materials: Daily cone-beam computed tomography data for 100 patients (4,237 scans) were analyzed. Subsequently, four less-than-daily IG protocols were simulated using these data (no IG, first 5-day IG, weekly IG, and alternate-day IG). The frequency and magnitude of residual setup error were determined. The less-than-daily IG protocols were compared against the daily IG, the assumed reference standard. Finally, the population-based setup margins were calculated. Results: With the less-than-daily IG protocols, 20-43% of fractions incurred residual setup errors {>=}5 mm; daily IG reduced this to 6%. With the exception of the first 5-day IG, reductions in systematic error ({Sigma}) occurred as the imaging frequency increased and only daily IG provided notable random error ({sigma}) reductions ({Sigma} = 1.5-2.2 mm, {sigma} = 2.5-3.7 mm; {Sigma} = 1.8-2.6 mm, {sigma} = 2.5-3.7 mm; and {Sigma} = 0.7-1.0 mm, {sigma} = 1.7-2.0 mm for no IG, first 5-day IG, and daily IG, respectively. An overall significant difference in the mean setup error was present between the first 5-day IG and daily IG (p < .0001). The derived setup margins were 5-9 mm for less-than-daily IG and were 3-4 mm with daily IG. Conclusion: Daily cone-beam computed tomography substantially reduced the setup error and could permit setup margin reduction and lead to a reduction in normal tissue toxicity for patients undergoing conventionally fractionated lung radiotherapy. Using first 5-day cone-beam computed tomography was suboptimal for lung patients, given the inability to reduce the random error and the potential for the systematic error to increase throughout the treatment course.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dark Energy Survey Year 1 results: weak lensing mass calibration of redMaPPer galaxy clusters

We constrain the mass-richness scaling relation of redMaPPer galaxy clusters identified in the Dark Energy Survey Year 1 data using weak gravitational lensing. We split clusters into 4 x 3 bins of richness lambda and redshift z for lambda >= 20 and 0.2 <= z <= 0.65 and measure the mean masses of these bins using their stacked weak lensing signal. By modelling the scaling relation as M-200m|lambda, M-0(lambda/40)(F)((1 + /1.35)(G), we constrain the normalization of the scaling relation at the 5.0 per cent level, finding M-0 = [3.081 +/- 0.075(stat) +/- 0.133(sys)] center dot 10(14) M-aS (TM) at lambda = 40 and = 0.35. The recovered richness scaling index is F = 1.356 +/- 0.051 (stat) +/- 0.008 (sys) and the redshift scaling index G = -0.30 +/- 0.30 (stat) +/- 0.06 (sys). These are the tightest measurements of the normalization and richness scaling index made to date from a weak lensing experiment. We use a semi-analytic covariance matrix to characterize the statistical errors in the recovered weak lensing profiles. Our analysis accounts for the following sources of systematic error: shear and photometric redshift errors, cluster miscentring, cluster member dilution of the source sample, systematic uncertainties in the modelling of the halo-mass correlation function, halo triaxiality, and projection effects. We discuss prospects for reducing our systematic error budget, which dominates the uncertainty on M-0. Our result is in excellent agreement with, but has significantly smaller uncertainties than, previous measurements in the literature, and augurs well for the power of the DES cluster survey as a tool for precision cosmology and upcoming galaxy surveys such as LSST, Euclid, and WFIRST

clusters↗

The Experimental Probe of Inflationary Cosmology: A Mission Concept Study for NASA's Einstein Inflation Probe

When we began our study we sought to answer five fundamental implementation questions: 1) can foregrounds be measured and subtracted to a sufficiently low level?; 2) can systematic errors be controlled?; 3) can we develop optics with sufficiently large throughput, low polarization, and frequency coverage from 30 to 300 GHz?; 4) is there a technical path to realizing the sensitivity and systematic error requirements?; and 5) what are the specific mission architecture parameters, including cost? Detailed answers to these questions are contained in this report.

Experimental Probe of Inflationary Cosmology (EPIC↗

A SURVEY OF ALKALI LINE ABSORPTION IN EXOPLANETARY ATMOSPHERES

We obtained over 90 hr of spectroscopic observations of four exoplanetary systems with the Hobby-Eberly Telescope. Observations were taken in transit and out of transit, and we analyzed the differenced spectra-i.e., the transmission spectra-to inspect it for absorption at the wavelengths of the neutral sodium (Na I) doublet at {lambda}{lambda}5889, 5895 and neutral potassium (K I) at {lambda}7698. We used the transmission spectrum at Ca I {lambda}6122-which shows strong stellar absorption but is not an alkali metal resonance line that we expect to show significant absorption in these atmospheres-as a control line to examine our measurements for systematic errors. We use an empirical Monte Carlo method to quantify these systematic errors. In a reanalysis of the same data set using a reduction and analysis pipeline that was derived independently, we confirm the previously seen Na I absorption in HD 189733b at a level of (- 5.26 {+-} 1.69) Multiplication-Sign 10{sup -4} (the average value over a 12 A integration band to be consistent with previous authors). Additionally, we tentatively confirm the Na I absorption seen in HD 209458b (independently by multiple authors) at a level of (- 2.63 {+-} 0.81) Multiplication-Sign 10{sup -4}, though the interpretation is less clear. Furthermore, we find Na I absorption of (- 3.16 {+-} 2.06) Multiplication-Sign 10{sup -4} at <3{sigma} in HD 149026b; features apparent in the transmission spectrum are consistent with real absorption and indicate this may be a good target for future observations to confirm. No other results (Na I in HD 147506b and Ca I and K I in all four targets) are significant to {>=}3{sigma}, although we observe some features that we argue are primarily artifacts.

79 ASTRONOMY AND ASTROPHYSICS↗

Postlaunch calibration of spacecraft attitude instruments

The accuracy of both onboard and ground attitude determination can be significantly enhanced by calibrating spacecraft attitude instruments (sensors) after launch. Although attitude sensors are accurately calibrated before launch, the stresses of launch and the space environment inevitably cause changes in sensor parameters. During the mission, these parameters may continue to drift requiring repeated on-orbit calibrations. The goal of attitude sensor calibration is to reduce the systematic errors in the measurement models. There are two stages at which systematic errors may enter. The first occurs in the conversion of sensor output into an observation vector in the sensor frame. The second occurs in the transformation of the vector from the sensor frame to the spacecraft attitude reference frame. This paper presents postlaunch alignment and transfer function calibration of the attitude sensors for the Compton Gamma Ray Observatory (GRO), the Upper Atmosphere Research Satellite (UARS), and the Extreme Ultraviolet Explorer (EUVE).

Davis, W.↗

SU-F-T-288: Impact of Trajectory Log Files for Clarkson-Based Independent Dose Verification of IMRT and VMAT

Purpose: To investigate the effect of the trajectory files from linear accelerator for Clarkson-based independent dose verification in IMRT and VMAT plans. Methods: A CT-based independent dose verification software (Simple MU Analysis: SMU, Triangle Products, Japan) with a Clarksonbased algorithm was modified to calculate dose using the trajectory log files. Eclipse with the three techniques of step and shoot (SS), sliding window (SW) and Rapid Arc (RA) was used as treatment planning system (TPS). In this study, clinically approved IMRT and VMAT plans for prostate and head and neck (HN) at two institutions were retrospectively analyzed to assess the dose deviation between DICOM-RT plan (PL) and trajectory log file (TJ). An additional analysis was performed to evaluate MLC error detection capability of SMU when the trajectory log files was modified by adding systematic errors (0.2, 0.5, 1.0 mm) and random errors (5, 10, 30 mm) to actual MLC position. Results: The dose deviations for prostate and HN in the two sites were 0.0% and 0.0% in SS, 0.1±0.0%, 0.1±0.1% in SW and 0.6±0.5%, 0.7±0.9% in RA, respectively. The MLC error detection capability shows the plans for HN IMRT were the most sensitive and 0.2 mm of systematic error affected 0.7% dose deviation on average. Effect of the MLC random error did not affect dose error. Conclusion: The use of trajectory log files including actual information of MLC location, gantry angle, etc should be more effective for an independent verification. The tolerance level for the secondary check using the trajectory file may be similar to that of the verification using DICOM-RT plan file. From the view of the resolution of MLC positional error detection, the secondary check could detect the MLC position error corresponding to the treatment sites and techniques. This research is partially supported by Japan Agency for Medical Research and Development (AMED)

60 APPLIED LIFE SCIENCES↗

Improved uncertainty quantification in nondestructive assay for nonproliferation

This paper illustrates methods to improve uncertainty quantification (UQ) for non-destructive assay (NDA) measurements used in nuclear nonproliferation. First, it is shown that current bottom-up UQ applied to calibration data is not always adequate, for three main reasons: (1) Because there are errors in both the predictors and the response, calibration involves a ratio of random quantities, and calibration data sets in NDA usually consist of only a modest number of samples (3–10); therefore, asymptotic approximations involving quantities needed for UQ such as means and variances are often not sufficiently accurate; (2) Common practice overlooks that calibration implies a partitioning of total error into random and systematic error, and (3) In many NDA applications, test items exhibit non-negligible departures in physical properties from calibration items, so model-based adjustments are used, but item-specific bias remains in some data. Therefore, improved bottom-up UQ using calibration data should predict the typical magnitude of item-specific bias, and the suggestion is to do so by including sources of item-specific bias in synthetic calibration data that is generated using a combination of modeling and real calibration data. Second, for measurements of the same nuclear material item by both the facility operator and international inspectors, current empirical (top-down) UQ is described for estimating operator and inspector systematic and random error variance components. A Bayesian alternative is introduced that easily accommodates constraints on variance components, and is more robust than current top-down methods to the underlying measurement error distributions.

97 MATHEMATICS AND COMPUTING↗

Two-pion contribution to hadronic vacuum polarization

We present a detailed analysis of e + e - → π + π - data up to \( \sqrt{s}=1 \) GeV in the framework of dispersion relations. Starting from a family of ππ P -wave phase shifts, as derived from a previous Roy-equation analysis of ππ scattering, we write down an extended Omnès representation of the pion vector form factor in terms of a few free parameters and study to which extent the modern high-statistics data sets can be described by the resulting fit function that follows from general principles of QCD. We find that statistically acceptable fits do become possible as soon as potential uncertainties in the energy calibration are taken into account, providing a strong cross check on the internal consistency of the data sets, but preferring a mass of the ω meson significantly lower than the current PDG average. In addition to a complete treatment of statistical and systematic errors propagated from the data, we perform a comprehensive analysis of the systematic errors in the dispersive representation and derive the consequences for the two-pion contribution to hadronic vacuum polarization. In a global fit to both time- and space-like data sets we find a ππ μ | ≤ 1 GeV = 495.0(1.5)(2.1) × 10 -10 and a ππ μ | ≤ 0.63 GeV = 132.8(0.4)(1.0) × 10 -10 . While the constraints are thus most stringent for low energies, we obtain uncertainty estimates throughout the whole energy range that should prove valuable in corroborating the corresponding contribution to the anomalous magnetic moment of the muon. As side products, we obtain improved constraints on the ππ P -wave, valuable input for future global analyses of low-energy ππ scattering, as well as a determination of the pion charge radius, $\langle$$r^{2}_{π}$$\rangle$ = 0 . 429(1)(4) fm 2 .

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analytical error bars and RSD for neutron multiplicity counting

This article derives the standard deviation of the moments of neutron multiplicity distributions for both random and (shift register) triggered counting gates by propagating the multinomial distribution of errors in the counting distribution. Exact and approximate analytical formulas for the singles, doubles, and triples error bars are given along with the corresponding RSD (relative standard deviation). These analytical formulas provide a simple way to analyze and predict error bars without needing empirical data or simulations. The comparison of these analytical error bars to actual measurement errors can reveal systematic errors that are not being accounted for in the modeling of the data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

BEYONDPLANCK II. CMB mapmaking through Gibbs sampling

We present a Gibbs sampling solution to the mapmaking problem for cosmic microwave background (CMB) measurements that builds on existing destriping methodology. Gibbs sampling breaks the computationally heavy destriping problem into two separate steps: noise filtering and map binning. Considered as two separate steps, both are computationally much cheaper than solving the combined problem. This provides a huge performance benefit as compared to traditional methods and it allows us, for the first time, to bring the destriping baseline length to a single sample. Here, we applied the Gibbs procedure to simulated Planck 30 GHz data. We find that gaps in the time-ordered data are handled efficiently by filling them in with simulated noise as part of the Gibbs process. The Gibbs procedure yields a chain of map samples, from which we are able to compute the posterior mean as a best-estimate map. The variation in the chain provides information on the correlated residual noise, without the need to construct a full noise covariance matrix. However, if only a single maximum-likelihood frequency map estimate is required, we find that traditional conjugate gradient solvers converge much faster than a Gibbs sampler in terms of the total number of iterations. The conceptual advantages of the Gibbs sampling approach lies in statistically well-defined error propagation and systematic error correction. This methodology thus forms the conceptual basis for the mapmaking algorithm employed in the BEYONDPLANCK framework, which implements the first end-to-end Bayesian analysis pipeline for CMB observations.

79 ASTRONOMY AND ASTROPHYSICS↗

WAVELENGTH CALIBRATION OF THE VLT-UVES SPECTROGRAPH

We attempt to measure possible miscalibration of the wavelength scale of the VLT-UVES spectrograph. We take spectra of QSO HE0515-4414 through the UVES iodine cell which contains thousands of well-calibrated iodine lines and compare these lines to the wavelength scale from the standard thorium-argon pipeline calibration. Analyzing three exposures of this z = 1.71 QSO, we find two distinct types of calibration shifts needed to correct the Th/Ar wavelength scale. First, there is an overall average velocity shift of between 100 m s{sup -1} and 500 m s{sup -1} depending upon the exposure. Second, within a given exposure, we find intra-order velocity distortions of 100 m s{sup -1} up to more than 200 m s{sup -1}. These calibration errors are similar to, but smaller than, those found earlier in the Keck HIRES spectrometer. We discuss the possible origins of these two types of miscalibration. We also explore the implications of these calibration errors on the systematic error in measurements of {Delta}{alpha}/{alpha}, the change in the fine-structure constant derived from measurement of the relative redshifts of absorption lines in QSO absorption systems. The overall average, exposure-dependent shifts should be less relevant for fine-structure work, but the intra-order shifts have the potential to affect these results. Using either our measured calibration offsets or a Gaussian model with sigma of around 90 m s{sup -1}, Monte Carlo mock experiments find errors in {Delta}{alpha}/{alpha} of between 1 x 10{sup -6} N {sup -1/2}{sub sys} and 3 x 10{sup -6} N {sup -1/2}{sub sys}, where N{sub sys} is the number of systems used and the range is due to dependence on how many metallic absorption lines in each system are compared.

79 ASTRONOMY AND ASTROPHYSICS↗

Lattice study of N=2 Landau-Ginzburg model using a Nicolai map

It has been conjectured that the two-dimensional N=2 Wess-Zumino model with a quasihomogeneous superpotential provides the Landau-Ginzburg description of the N=2 superconformal minimal models. For the cubic superpotential W={lambda}{Phi}{sup 3}/3, it is expected that the Wess-Zumino model describes A{sub 2} model and the chiral superfield {Phi} shows the conformal weight (h,h)=(1/6,1/6) at the IR fixed point. We study this conjecture by a lattice simulation, extracting the weight from the finite volume scaling of the susceptibility of the scalar component in {Phi}. We adopt a lattice model with the overlap fermion, which possesses a Nicolai map and a discrete R-symmetry. We set a{lambda}=0.3 and generate the scalar field configurations by solving the Nicolai map on LxL lattices in the range L=18-32. To solve the map, we use the Newton-Raphson algorithm with various initial configurations. The result is 1-h-h=0.660{+-}0.011, which is consistent with the conjecture within the statistical error, while a systematic error is estimated as less than 0.5%.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗