Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system value”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

PV Inverter Availability from the U.S. PV Fleet

In the PV Fleet Performance Data Initiative, we partner with photovoltaic (PV) fleet owners to collect time-series PV production data, and publish aggregated, anonymized results. An assessment of system availability is conducted on 1128 systems which passed our data quality checks, and include cumulative energy meter data. Overall inverter availability is low in the first 6 months of system performance before reaching steady-state by the end of the first year. System-level aggregated data shows a median (P50) system availability of 0.99, and a lower P90 value of 0.95. A dependence on system size is also identified, with better inverter availability results for smaller PV systems. Potential causes of this effect may include the selection of inverter itself: smaller inverters 6kW-250kW showed better average availability than inverters 300kW-5MW. The elimination of string combiner boxes and lower energy impact when one particular inverter goes off-line are potential benefits of a string inverter-based PV system architecture. DNV also analyzed availability data from over 1100 operating systems and found similar trends. DNV's P50 industry guidance on expected availability has been updated to reflect the data and the following observations: utility scale systems have lower availability than DG systems, availability is lower in first year compared to subsequent years, and that actual availability is lower than expected.

fleet↗

Real-time Optimal Dispatch of Behind-the-Meter DERs for Secondary Frequency Regulation

Active distribution networks (ADNs) can provide grid services such as peak load shaving, loss reduction, VoltNar control, congestion management, and frequency regulation. The fast response of inverter-based distributed energy resources (DERs) and battery storage systems enables them to provide ramping support and frequency control. This paper proposes a real-time optimization approach for behind-the-meter DERs to participate in the secondary frequency regulation. The proposed approach determines optimal set-points of output power of DERs to respond to requests from system operators (SOs) in realtime to maintain the frequency of the system at the nominal value. To satisfy the real-time requirement for the secondary frequency control, the nonlinear AC power flow model is linearized considering power losses in the system to achieve both high computational speed and acceptable accuracy. The optimization problem is rerun in a closed loop manner until the mismatch between the requested power by the system operators and actual delivered power at the substation reaches an acceptable tolerance. Furthermore, the proposed approach is validated using modified versions of the IEEE 33-bus and IEEE 69-bus distribution systems. Although the contribution of a single distribution system in the frequency regulation may not be significant, stacked and coordinated contributions from several distribution systems can provide frequency regulation and other grid services at scale.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Solar PV Curtailment in Changing Grid and Technological Contexts: Preprint

Solar photovoltaic (PV) systems generate electricity with no marginal costs or emissions. As a result, PV output is almost always prioritized over other fuel sources and delivered to the electric grid. At increasing levels of PV penetration situations arise where PV is curtailed, either because of local supply/demand imbalances or to maintain system flexibility. In 2018, we estimate that about 6.5 million MWh of PV output was curtailed in four key countries: Chile, China, Germany, and the United States. We find that PV curtailment peaks in the spring and fall, when PV output is relatively high but electricity demand is relatively low. Similar to the case of wind, some PV curtailment is attributable to limited transmission capacity connecting sparsely populated solar-heavy regions to load centers.Grid policies generally seek to minimize curtailment because it is viewed as an economic and environmental loss. However, we argue that changing grid and technological contexts warrant new thinking on PV curtailment. In the grid context, as grids integrate more PV and other renewable energy generation, seeking an optimal level of accepted curtailment becomes more efficient than preventing it. In the technological context, emerging technologies such as advanced inverters and low-cost battery storage are making PV systems more flexible. With flexible PV, grid operators can use withheld PV output to provide various non-generation grid services. This withheld PV output is a form of curtailment under prevailing definitions of the term. Hence, policies that aim to minimize curtailment may undercut the ability of grid operators to fully use the emerging capabilities of flexible PV systems. We argue that the changing grid and technological contexts require a re-examination of the curtailment paradigm. We argue that PV output that is withheld to provide grid services is fundamentally different from output that goes unused in response to system constraints. As a result, we propose a more exclusive definition of curtailment as unused PV output rather than the more expansive conventional definition as any reduction in system output from its technical potential. The terminological distinction is more than a question of semantics. Facilitating grid services by withholding PV output may increase the potential value of flexible PV systems to the grid. This shift in thinking may allow grid operators and policymakers to think in terms of PV curtailment management rather than minimization. Effective curtailment management may include policies that increase PV system dispatchability, alternative PV compensation schemes that decouple generator revenue from system output, and policies to increase grid flexibility.

Chile↗

A Guide for Improved Resource Adequacy Assessments in Evolving Power Systems: Institutional and Technical Dimensions

This paper identifies and evaluates issues in traditional resource adequacy (RA) assessment practices, and how adjusting these practices may affect and depend on existing institutional arrangements for planning and procurement. The paper proposes a technical-institutional roadmap that would allow regulators in vertically-integrated jurisdictions and system planners and operators in restructured jurisdictions to revise RA practices across a range of components. First, we compile a critical review of current RA assessment practices based on (1) interviews with RA practitioners and (2) a review of recent technical literature. We find that (i) RA may need to expand beyond capacity adequacy to ensure energy adequacy – relevant for energy-limited resources such as storage – and potentially some form of ancillary service adequacy (e.g. enough ramping-up and ramping-down capability in the system); (ii) chronological hourly simulations for all hours in the year are the current best practice; (iii) metrics and models used do not reflect economic criteria in system operation and loss of load; and (iv) there is a need to improve representation of weather dependencies and weather data. Second, we review planning and RA reports for several private and public entities that plan generation and/or transmission infrastructure in the continental U.S. to look for existing practices involving resilience assessments. We find no systematic treatment of the costs of extreme weather and other hazards, the benefits of resilience, and resilience metrics in planning analyses and no systematic treatment of resilience metrics, methods, and outcomes for resource adequacy purposes. Third, we create a technical framework for probabilistic RA assessment and use it to study how key choices about how to model power system operations affect the values that are obtained for RA metrics. We find that (i) non-economic dispatch schemes that ignore economic objectives can lead to accurate RA assessments when coordinated with detailed operational strategies; (ii) multi-year data is critical to capture a wide variety of system conditions; (iii) not incorporating transmission limits into RA assessment could lead to substantial underestimation of traditional “expected value” RA metrics; and (iv) new RA metrics that capture event-specific shortfall characteristics should be used as supplements to traditional metrics. Finally, we examine RA assessments and use this information to propose a guide of evolving industry standards for resource adequacy assessments in resource planning and transmission planning. We report minimum, best, and frontier practices for temporal resolution of assessments, metrics and targets, weather data, load forecasting, characterization of variable renewable resources, characterization of transmission and market transactions, RA modeling and integration with planning processes, and capacity accreditation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Defining Electrode-Level Metrics for Enabling Earth-Abundant, Mn-Rich Cathodes: A Technoeconomic Analysis of Experimental Materials

Manganese-rich oxides are attractive options as next-generation, earth-abundant cathodes and significant efforts are being directed toward commercial implementation. We report here an updated techno-economic analysis of the lithium- and manganese-rich (LMR) class of earth-abundant cathodes for electric vehicle applications. BatPaC modeling was used to define the cell-level metrics that must be met for these materials to be cost and energy competitive with the current commercial earth-abundant benchmark, LiFePO 4 , as well as anticipated variations such as LiMn 0.8 Fe 0.2 PO 4 . The model was used to evaluate a high-performance material from the literature and subsequently define R&D targets as the likely limits of practical performance for similar LMR systems. Experimental validation and BatPaC evaluation of an advanced, cobalt-free LMR cell system was also conducted. Results show that the advanced LMR cells come within ∼5% of the defined limits and exceed the energy of LiFe(Mn)PO 4 cells at a similar cost. Excellent cycle-life, low impedance, and low impedance rise were also achieved under the conditions tested and reveal that cobalt is not necessary to achieve high-performance LMR oxides. Although the analysis conducted herein reports on LMR cell systems, the methodology and target values defined for performance metrics easily extend to the evaluation of other systems under consideration as earth-abundant options.

Chen, Jiajun [Argonne National Laboratory (ANL), A↗

Exploring Multidimensional Spatial-Temporal Hydropower Operational Flexibilities by Modeling and Optimizing Water-Constrained Cascading Hydroelectric Systems

Because of unique characteristics such as clean and cost-competitive electricity as well as fast-ramping and storage abilities, the power industry continues to evolve its operation strategies for cascading hydroelectric (CHE) systems for providing enhanced values to the grid, especially under the deeper renewable resource integration. However, existing operation practices of CHEs predate the integration of renewables, which could prohibit the effective utilization of their inherent flexibilities in delivering maximum financial benefits and providing valuable grid services to the power system and electricity market operations. Indeed, modeling and optimizing these resource-limited while flexible CHE assets with uncertainties and imperfect information across multiple spatial-temporal dimensions present significant challenges. To facilitate CHE facility operators in effectively coordinating water usage and hydropower plant operations across multiple timescales, this project aims to fill the existing gaps by developing a suite of accurate water inflow (WI) forecast models as well as enhanced CHE modeling and optimization approaches with proper consideration of their unique characteristics, which would help explore their multidimensional spatial-temporal operational flexibility potentials. The developed approaches could better align reservoir operation strategies with variability and uncertainty of future water availability. They can also promote more effective utilization of multidimensional spatial-temporal hydropower operational flexibility potentials by designing long-term evacuation plans of reservoirs and short-term operation of CHEs, along with their coordination with other types of renewables. The project leverages various resources to facilitate the research and development activities, including actual characteristics data of CHE systems and a library of current and future cases of Portland General Electric (PGE). These realistic data enable the project team to study how to maximize the value of CHEs under current and future portfolios and evaluate opportunities to improve operation practices.

13 HYDRO ENERGY↗

Application of step-response lambda tuning to proportional-integral controllers in water resource recovery facilities

Proportional-integral-derivative (PID) controllers in water resource recovery facilities (WRRFs) feedback control loops are commonplace. While simple to implement, such control loops are rarely tuned optimally or systematically. Heuristic tuning approaches are commonly applied with varying degrees of success using trial-and-error, ad hoc tuning rules, or duplication of tuning values from a similar system. However, there are effective methods, such as lambda tuning, produce acceptable tuning with limited effort. These are based on the step-response method, where a manual process perturbation is used to define the relationship between the manipulated and controlled variables. Based on such an experiment, a simple process model is constructed and used to determine the controller tuning values. In this work, we used the step-response method and lambda tuning for two control systems in full-scale WRRFs. This led to responsive and stable behavior of the controlled system as defined by the absolute average error of the controlled variable to setpoint and standard deviation of the manipulated variable. Tuning of feedback control loops can be completed successfully through a systematic approach, and this work suggests that tuning tools, like lambda, should be part of all wastewater treatment control engineers' toolbox.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Case Study Investigating the Low Summertime CAPE Behavior in the Global Forecast System

Convective available potential energy (CAPE) is an important index for storm forecasting. Recent versions (v15.2 and v16) of the Global Forecast System (GFS) predict lower values of CAPE during summertime in the continental United States than analysis and observation. We conducted an evaluation of the GFS in simulating summertime CAPE using an example from the Unified Forecast System Case Study collection to investigate the factors that lead to the low CAPE bias in GFS. Specifically, we investigated the surface energy budget, soil properties, and near-surface and upper-level meteorological fields. Results show that the GFS simulates smaller surface latent heat flux and larger surface sensible heat flux than the observations. This can be attributed to the slightly drier-than-observed soil moisture in the GFS that comes from an offline global land data assimilation system. The lower simulated CAPE in GFS v16 is related to the early drop of surface net radiation with excessive boundary layer cloud after midday when compared with GFS v15.2. A moisture-budget analysis indicates that errors in the large-scale advection of water vapor does not contribute to the dry bias in the GFS at low levels. Common Community Physics Package single-column model (SCM) experiments suggest that with realistic initial vertical profiles, SCM simulations generate a larger CAPE than runs with GFS IC. SCM runs with an active LSM tend to produce smaller CAPE than that with prescribed surface fluxes. Note that the findings are only applicable to this case study. Including more warm-season cases would enhance the generalizability of our findings.

54 ENVIRONMENTAL SCIENCES↗

Applications of Thermochemical Modeling in Molten Salt Reactors

The extensively evaluated and consistent thermodynamic database, the Molten Salt Thermal Properties Database—Thermochemical (MSTDB-TC), was used along with additional thermodynamic values from other sources as examples of ways to examine molten salt reactor (MSR) fuel behavior. Relative stability with respect to halide potential and temperature for likely fuel and fission product components were mapped in Ellingham diagrams for the chloride and fluoride systems. The Ellingham diagrams provide a rich, visual means for identifying halide-forming components in proposed fuel/solvent salt systems. Thermochemical models and values from MSTDB-TC and ancillary sources were used in global equilibrium calculations to provide compositions for a close analysis of the behavior of a possible Molten Chloride Salt Fast Reactor and a Molten Salt Reactor Experiment-type system at high burnup (100 GWd/t). The results illustrated the oxidative nature of burnup in MSRs and provided information about redox behavior and possible control.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Demand Response in Bangalore: Implications for Electricity System Operations

Recent Greening the Grid studies for India highlight the benefits of flexible resources for integrating variable renewable energy onto India’s electricity system. India’s ambitious renewable energy targets, which are particularly focused on renewable resource states such as Karnataka, will face fewer challenges when combined with new planning and operational strategies and technologies. This report explores one such strategy - demand response - by which the system operator shifts load throughout a day to minimize system wide production costs. To explore this strategy, we added demand response resources to Karnataka’s electricity system in a production cost model of India, using load shifting potential analyzed by Lawrence Berkeley National Labs. We then investigated the impacts of increasing demand response capacity under several renewable resource scenarios. Our results show the addition of demand response enables fuel shifting from high-marginal-cost and emissions-intensive subcritical coal and diesel generation to zero-marginal-cost and emissions-free renewable generation. Accordingly, the value that demand response provides to the system increases as the renewable penetration increases. In addition to reducing production costs and emissions, demand response reduces the time that thermal generators spend at their minimum output levels, which typically represents a less efficient and costlier operational state. Agricultural load shifting provides greater value to the system than residential, commercial, or industrial loads. Agricultural demand response is more flexible than other sectors because it is not exposed to subdaily operational constraints and it can operate for more hours per day without impacting customer satisfaction. Further, the first increment of demand response that is added to a system provides the greatest value; further additions provide additional benefits but have a decreasing impact. The insights we discuss could be leveraged by system planners and operators in other jurisdictions, particularly those facing significant renewable energy penetrations, to develop their own demand response programs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Global techno-economic and life cycle greenhouse gas emissions assessment of solar and wind based renewable hydrogen production

This study conducts a global assessment of renewable hydrogen production pathways, focusing on techno-economic performance and life cycle greenhouse gas (GHG) emissions. It evaluates standalone solar photovoltaic (PV), wind, and hybrid PV/wind systems, integrated with proton exchange membrane (PEM) electrolyzers, through multi-objective optimization and considering embodied emissions in manufacturing PV, wind and electrolyzers. Results identify optimal configurations to minimize levelized cost of hydrogen (LCOH) and carbon intensity (CI) of hydrogen, showing potential reductions of cost and CI by 2030. Standalone PV systems can achieve LCOH values smaller than 6.5 USD/kg H 2 and CI less than 2.5 kg CO 2 eq/kg H 2 in regions with high solar irradiance, such as North Africa, the Middle East and Chile. Wind systems in regions such as Middle East, North Africa, Australia and Central United States achieve LCOH below 5 USD/kg H 2 and CI under 1.5 kg CO 2 eq/kg H 2 . Hybrid systems emerge as the optimal solution for minimizing both the LCOH and CI by maximizing the use of renewable energy. Moreover, the results also indicate that, with the technological advancements, future reduction in the capital cost of renewable energy systems and the PEM electrolyzer as well as the trade of coproduct O 2 could drive the LCOH of all the RES-based hydrogen systems below 1 USD/kg H 2 and the CI below zero in different regions as Middle East, North Africa and Central United State

08 HYDROGEN↗

Clearing a Path to Commercialization of Marine Renewable Energy Technologies Through Public–Private Collaboration

Governments are increasingly turning toward public–private partnerships to bring industry support to improving public assets or services. Here, we describe a unique public–private collaboration where a government entity has developed mechanisms to support public and private sector advancement and commercialization of monitoring technologies for marine renewable energy. These support mechanisms include access to a range of skilled personnel and test facilities that promote rapid innovation, prove reliability, and inspire creativity in technology development as innovations move from concept to practice. The ability to iteratively test hardware and software components, sensors, and systems can accelerate adoption of new methods and instrumentation designs. As a case study, we present the development of passive acoustic monitoring technologies customized for operation in energetic waves and currents. We discuss the value of testing different systems together, under the same conditions, as well as the progression through different test locations. The outcome is multiple, complementary monitoring technologies that are well suited to addressing an area of high environmental uncertainty and reducing barriers to responsible deployment of low-carbon energy conversion systems, creating solutions for the future.

16 TIDAL AND WAVE POWER↗

Renewable-battery hybrid power plants in congested electricity markets: Implications for plant configuration

Examining coupled renewable-battery power plants (“hybrids”) in congested areas provides insights into a future of increased wind and solar penetration. Our study focuses on two types of congested regions, Variable Renewable Energy (VRE)-rich Areas and Load Centers, and explores likely plant configuration choices for developers and transmission network planners. Here, this paper examines how hybrid value, comprising energy and capacity value, varies by plant configuration and congested region type considering factors such as storage duration, battery degradation, and ability to charge from the grid. We select plant locations from across the seven main U.S. independent system operators (ISOs). Hybrid value for each configuration is computed based on profit-maximizing plant operation given perfect foresight, according to observed wholesale power market real time prices from 2018 to 2021. In VRE-rich Areas, the median increase in energy value from extending storage duration from one to 4h is 29.4% for solar and 26.8% for wind, assuming low battery degradation costs and storage sized to 100% of the plant's nameplate generation capacity. Increasing storage duration beyond 4h does not substantially increase its value from energy markets, even in VRE-rich Areas. We find that solar hybrids reach a 90% capacity credit with 4h of storage, while wind hybrids require 8h of storage, based on the capacity factor of each hybrid during the top 100 net load hours.

24 POWER TRANSMISSION AND DISTRIBUTION↗

On the operational characteristics and economic value of pumped thermal energy storage

Pumped thermal energy storage (PTES) systems use an electrically-driven heat pump to store electricity in the form of thermal energy, and subsequently dispatch the stored thermal energy to generate electricity using a thermodynamic heat engine. Optimal day-ahead operational scheduling and annual value of a PTES system based on Joule-Brayton thermodynamic cycles and two-tank molten salt hot thermal storage is evaluated in this work. Production cost models, which simultaneously optimize commitment and dispatch schedules for an entire set of generators to minimize the cost of satisfying electricity demand, are employed to determine system-optimal operation and day-ahead energy value of the PTES system within each of six hypothetical near-future grid scenarios intended to approximately represent the U.S. Western Interconnection or the Texas Interconnection. Sensitivity to grid scenario (including the contribution of variable renewable energy sources), thermal storage capacity, relative heat pump and heat engine capacities, and startup/shutdown cycling costs are evaluated. PTES energy value and heat engine annual capacity factor increase strongly as the contribution of variable renewable resources increases, heat pump capacity increases relative to heat engine capacity, or PTES cycling costs decrease. Grid scenarios in which the contribution of variable renewable energy is dominated by solar photovoltaics (PV) vs. wind produce inherently different PTES operational patterns. Annual PTES energy value within PV-dominated scenarios increased with storage capacity only up to approximately seven hours of full-load discharge capacity, whereas that within wind-dominated scenarios exhibited a continual increase with storage duration up to at least 16 hours.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Role and Value of Interregional Transmission in a Decarbonized U.S. Electricity System

Decarbonizing the U.S. energy system entails a significant expansion of wind and solar power and electrification of end-use applications. Achieving both is more efficient and less costly when interregional transmission capacity is expanded, but the fractured nature of grid planning in the United States is often a barrier to such expansion. Here, we explore the role of interregional transmission under a variety of decarbonization scenarios, using a capacity-expansion model to generate co-optimized portfolios of generation, storage, and transmission that meet decarbonization targets and electrification-driven demand. We explore portfolio and cost differences across 92 scenarios, from scenarios with limited transmission expansion to those that include a meshed high-voltage direct current (HVDC) network. In the core decarbonization scenarios, wind capacity expands by ~10x and solar by ~20x compared to 2020, hundreds of gigawatts of battery storage are deployed, and interregional transmission expands by 3-6x. Transmission expansion occurs nationwide but is concentrated between the central "wind belt" and eastern load centers. The HVDC scenarios result in hundreds of billions of dollars of savings in total system cost, demonstrating the economic benefits of interregional transmission in support of rapid decarbonization.

capacity expansion↗

RFA-17-14597, Methodology for Meeting Containment System Principal Design Criteria to Maximize the Passive Safety Value in Advanced Nuclear Energy Economic Competitiveness

Advanced (Non-Light Water) Reactors are being designed with Passive Safety as an essential and integral feature. To help streamline the licensing of advanced reactors, the DOE and the NRC have drafted Principal Design Criteria (PDCs) for advanced reactors. A question that remains to be answered is: how an Advanced Reactor take credit for passive safety features inherent in certain advanced reactors while at the same time complying the evolving PDC.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Review of Value of Solar Studies In Theory and In Practice

This brief summarizes a collection of state- and utility-commissioned value-of-solar (VoS) studies and related literature, with a focus on who commissioned the study, which value and cost categories were discussed and/or quantified, and the methods used. Our objective is to compile information on prior VoS studies to inform state regulators and other stakeholders that may pursue related studies or integrate findings into rate design. The brief is organized into three parts: 1) an introduction to distributed solar photovoltaic (DPV) compensation; 2) a review of theoretical research on VoS; and 3) a review of VoS studies. The vast majority of VoS studies have served an informational role of quantifying the net benefits of PV. Three studies were commissioned in states or utility service territories that subsequently implemented VoS tariffs in California, New York, and Austin, Texas. When applied as a tariff, VoS aims to compensate PV output as efficiently as possible by doing so at rates that reflect the marginal benefits and costs of PV through value and cost categories that may vary temporally and/or geographically. This could lead to higher compensation in locations and times where more PV output is more valuable and consequently drive adoption in those locations to provide more societal benefits. Value and cost factors can be broadly grouped into five categories: generation, transmission, distribution, other utility, and other social categories. Those conducting VoS studies must weigh various tradeoffs when deciding which categories to include and quantify. Tradeoffs include prioritizing values based on their magnitude of value or cost impact, as well as taking into account the feasibility of data collection and accurate quantification. Values of higher magnitude and estimation feasibility are quantified in the majority of studies, including the earliest of studies conducted in the 2000s and 2010s. Additionally, some values of higher magnitude but low feasibility in the earliest of studies have become quantifiable in recent years. There are some values with low average system-wide levels but very high magnitude in specific locations or hours. The value magnitude in some cases can be tied to DPV penetration with low value in areas with little congestion and/or low penetration and vice versa. In these cases, values that are easier to quantify are often incorporated, while those that are more difficult are often addressed via a placeholder value. The placeholder value is paired with a discussion around data needs and methods to improve future estimates, as well as a conversation about when these value categories may increase in magnitude and necessitate more rigorous quantification. This brief summarizes findings from two meta-analyses of VoS studies that took place between 2005 and 2018, as well as findings from four additional studies published from 2018 to 2023. Table ES-1 summarizes the various value and cost categories included in each respective study and whether they were quantified, discussed, or omitted. Values such as avoided energy, capacity, transmission capacity, line losses, and avoided environmental costs are quantified in every study. Some categories were deemed harder to quantify and less impactful at the time of the study, so they were discussed but not quantified (e.g., ancillary services). Other categories, including many at the distribution level, were very locationally and/or temporally specific and dependent on high DPV penetration. These were sometimes quantified and at other times discussed. Notably, when it came to utility costs, integration costs were discussed in all cases, though they were deemed to have a small impact. Other utility costs were omitted for the most part; however, the utility-commissioned study (by NorthWestern Energy in Montana) included both lost utility revenue and programmatic/administrative cost categories. While there are some similarities across studies, each had fairly unique methods that are detailed in the body of this brief.

14 SOLAR ENERGY↗

Measurement of the longitudinal flow-plane decorrelation using multiplane cumulants in $\sqrt{s_{NN}}$ = 200 GeV Au+Au, Ru+Ru, and Zr+Zr collisions

Measurements of the variation of anisotropic flow-plane angles (𝛹 𝑛 ) with rapidity, commonly known as the flow-plane decorrelation, provide important insights into the initial conditions of the matter produced in heavy-ion collisions. Here, in this paper, using data collected by the STAR experiment, we report the first measurement of the four-plane correlator observable 𝑇 𝑛 ⁡{𝑏⁢𝑎;𝑑⁢𝑐}=⟨⟨sin⁡[𝑛⁢(𝛹$^𝑏_𝑛$ − 𝛹$^𝑎_𝑛$)]⁢sin⁡[𝑛⁢(𝛹$^𝑑_𝑛$ − 𝛹$^𝑐_𝑛$)]⟩⟩, where superscripts 𝑎, 𝑏, 𝑐, and 𝑑 denote sequential pseudorapidity (𝜂) regions with 𝑎 corresponding to the most backward region, 𝑏 and 𝑐 close to mid-rapidity with 𝜂 𝑏 < 0 and 𝜂 𝑐 > 0, and 𝑑 being the most forward. The measurement is performed for the elliptic and triangular flow (i.e.~𝑛 = 2 and 3) in Au+Au and isobar (Ru+Ru, Zr+Zr) collisions at $\sqrt{s_{NN}}$=200~GeV. The goal of calculating the correlation of the flow-plane angle variations from backward to mid-central, and from mid-central to forward regions, is to probe the systematic variation of flow angle over a wide 𝜂 range. In mid-central collisions (10−30% centrality), we find 𝑇 2 ⁡{𝑏⁢𝑎;𝑑⁢𝑐} =−0.004 ±0.001⁢(s⁢t⁢a⁢t) ±0.002⁢(s⁢y⁢s⁢t) independent of the collision system. Such a small value of 𝑇 2 favors a random-walk'' variation of the flow-plane angles, where the rapidity correlation length is smaller than the entire region under study. These measurements provide new information on the decorrelation patterns in the system and offer a quantitative estimate of possible systematic variations in anisotropic flow angles such astwist’’ between forward and backward regions. This opens new opportunities for understanding the three-dimensional structure and the time evolution of the quark-gluon plasma created in heavy-ion collisions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗