Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “stress testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Development and evaluation of a fault-tolerant multiprocessor (FTMP) computer. Volume 4: FTMP executive summary

The FTMP architecture is a high reliability computer concept modeled after a homogeneous multiprocessor architecture. Elements of the FTMP are operated in tight synchronism with one another and hardware fault-detection and fault-masking is provided which is transparent to the software. Operating system design and user software design is thus greatly simplified. Performance of the FTMP is also comparable to that of a simplex equivalent due to the efficiency of fault handling hardware. The FTMP project constructed an engineering module of the FTMP, programmed the machine and extensively tested the architecture through fault injection and other stress testing. This testing confirmed the soundness of the FTMP concepts.

Smith, T. B., III↗

Changes in SSL Device Efficiency and Optical Performance Under Accelerated Aging Conditions

Lighting application efficiency (LAE) describes the efficient delivery of light from the light source to the lighted task and is viewed as a new frontier—increasing energy savings with solid-state lighting (SSL) technologies. The framework for LAE that is proposed by the U.S. Department of Energy (DOE) consists of four major elements: light source efficiency, optical delivery efficiency, spectral efficiency, and intensity effectiveness. This report focuses on a sampling of the available SSL products that can be broadly defined as having modified spectral output because the method of spectra modification has a significant impact on light source efficiency and long-term optical delivery and spectral efficiencies. This report focused on the changes in light source, optical delivery, and spectral efficiencies that occur during aging of SSL devices. An accelerated stress test (AST) regiment was developed for the devices under test (DUTs) examined in this report to provide insights into how the performance of SSL devices change with aging. The AST protocols demonstrate that the SSL products discussed in this report often reduce light source efficiency to achieve different spectral characteristics. In addition, aging of the optical components (e.g., lenses, solder masks) in SSL devices can produce increased light absorption, which negatively impacts optical delivery efficiency and light source efficiency. The modified spectral outputs of the selected SSL products discussed in this report come in a variety of form factors and achieve enhanced optical performance by using a variety of methods. All of the products examined in this study use mid-power light-emitting diodes (MP-LEDs), although the number, configuration, phosphor content, and light-emitting diode (LED) pump of the MP-LEDs differ. Product MS-1 is a 60-watt (W) replacement A19 lamp with a hermetically sealed glass globe, which contains an embedded optical filter to absorb green and yellow emissions, thereby creating a “sunlike” modified spectrum. Product MS-2 is a 60-W replacement A19 lamp with 30 MP-LEDs, and it uses a violet LED pump, along with green and red phosphor emissions, to produce a “healthy” spectrum. This spectrum omits blue emissions in an effort to reduce melanopic lux. Product MS-3 is an LED module consisting of 21 MP-LEDs that use a violet LED pump, along with blue, green, and red phosphors, to produce a “sunlike” spectrum. Products MS-4 and MS-5 are both 6-inch (in) downlights that use a manual switching mechanism so that users can select application-specific correlated color temperatures before installation. Products MS-4 and MS-5 both contain two LED primaries (2,700 Kelvin [K] and 5,000 K) for spectral tuning. Product MS-4 contains 12 MP-LEDs for each LED primary, and Product MS-5 contains 10 MP-LEDs for each LED primary. This report summarizes the overall findings from up to 8,000 hours (hrs) of AST on the lamp DUTs (Products MS-1 and MS-2); up to 5,000 hrs of AST on the LED light engine DUTs (Product MS-3); and up to 7,000 hrs of AST on the downlight DUTs (Products MS-4 and MS-5). The AST procedures used in this study included a room temperature operational life (RTOL) test, an operational life test conducted at 45 degrees Celsius (°C; 45OL) test, an operational life test conducted at 75°C (75OL), a wet high-temperature operational life test performed at 65°C and 90% relative humidity (6590), and a wet high-temperature operational life test performed at 75°C and 75% relative humidity (7575). The AST procedures used for Products MS-1 and MS-2 were RTOL, 45OL, and 6590. The AST procedures used for Products MS-3, MS-4, and MS-5 were RTOL, 75OL, and 7575. During the ASTs described herein, separate populations of each product (three DUTs in each population for Products MS-1, MS-2, MS-4, and MS-5; four DUTs in each population for Product MS-3) were subjected to power cycling of 1 hr on and 1 hr off. The key findings from this study include the following. Enhanced optical performance came at the cost of reduced light source efficiency for the lamps and light engines examined in this study. The optical filter used to produce a “sunlike” spectrum for Product MS-1 reduced light source efficiency by 26%, from 113 lumens per watt (lm/W) to 85 lm/W. Products MS-2 and MS-3 that used a violet-pumped LED to achieve “healthy” and “sunlike” enhanced optical performance, respectively, suffered the largest reduction in initial light source efficiency (49 lm/W for Product MS-2 and 68 lm/W for Products MS-3) perhaps because of the use of violet LED as the optical pump. Product MS-2 also had the poorest color fidelity because of undersaturation of blues and oversaturation of greens and yellows. Chromaticity maintenance of the products in this study was generally good, with parametric failure only occurring for one product at one AST condition (i.e., Product MS-3 at 7575). The chromaticity shift for Product MS-3 in 7575 test conditions resulted from reduced emissions of the broad green and red phosphors used to mimic sunlight in the 500–750 nanometer (nm) range. As a result of these phosphor emission losses, chromaticity shifted toward the more stable violet-pumped LED and blue phosphor. Although chromaticity maintenance was acceptable for most products tested, different chromaticity shift mechanisms were observed for temperature and humidity tests compared with temperature alone for Products MS-1, MS-2, and MS-3. For Product MS-1, a relative increase in green emissions was observed with humidity, which may indicate humidity-accelerated degradation of the optical filter at green wavelengths (optical delivery efficiency reduction) or degradation of the emitters in the red region (spectral efficiency reduction). The violet-pumped products (i.e., MS-2 and MS-3) exhibited different chromaticity shift behavior in the temperature-humidity environments, with Product MS-2 shifting generally yellow because of photo-induced oxidation of the plastic globe (i.e., a reduction of optical delivery efficiency) and Product MS-3 shifting toward violet and blue emitters because of faster loss of emission from green and red phosphors (i.e., a reduction in spectral efficiency). Because of an initial drop in power consumption, the light source efficiency of downlights (Products MS-4 and MS-5) increased at RTOL throughout the test duration. The light source efficiency initially increased during 75OL until a decay in luminous flux maintenance (LFM) dominated light source efficiency, whereas the light source efficiency decreased for the entire 7575 test duration. It was found that increasing the ambient environment of an SSL device from 25°C to 75°C decreases the LFM by 2.7 to 5.5, depending on design of the SSL device. Adding humidity to the system (75OL to 7575) was found to decrease LFM by another factor of approximately 3.0. A common location of failure was identified for the downlights (Products MS-4 and MS-5) operated in the 7575 environment. This failure abruptly occurred between 3,000 to 5,000 hrs of testing on the film capacitor of the electromagnetic interference (EMI) filter near the diode bridge for 11 of the 12 downlights. It is likely that this failure was caused by a combination of the high electrical voltage across the capacitor, the location of the capacitor near the heat sources (e.g., transformers, diode bridges, power resistors), and the high stress environment of 7575. Longer test times are needed to fully understand the LFM, luminous efficacy changes, and chromaticity shifts for some of the products. Because of the high reliability, light source efficiency, and spectral tuning capabilities of LEDs, the expectations of LAE for SSL products are greatly increased over traditional lighting products. The data gathered in this report begin to provide an understanding of the tradeoffs that current SSL products undergo when optimizing the different efficiency elements of LAE. As discussed in this report, the findings from the tests conducted show that the optimization of spectral efficiency can come at the cost of initial light source efficiency. Furthermore, the introduction of violet LEDs can promote long-term optical delivery efficiency degradation, and the introduction of optical filters or new phosphors can lead to unwanted spectral efficiency changes because the ratio of phosphor emitters changes with aging. The data presented in this report also identified a common failure location in 6-in downlights. The results regarding long-term behavior of the modified spectra devices studied provide valuable information about changes to the light source, spectral, and optical delivery efficiencies as the devices age. This information can be used to improve future SSL designs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Exercise response

The bicycle ergometer and a graded stress protocol were used to conduct exercise stress tests for the Apollo project. The graded exercise tests permitted a progressive evaluation of physiological control system response and provided a better understanding of safe stress limits; heart rate was used for determining stress levels. During each test, workload, heart rate, blood pressure, and respiratory gas exchange (oxygen consumption, carbon dioxide production, and minute volume) measurements were made. The results are presented and discussed.

J.A. Rummel↗

Interpretation and classification of microvolt T wave alternans tests

Measurement of microvolt-level T wave alternans (TWA) during routine exercise stress testing now is possible as a result of sophisticated noise reduction techniques and analytic methods that have become commercially available. Even though this technology is new, the available data suggest that microvolt TWA is a potent predictor of arrhythmia risk in diverse disease states. As this technology becomes more widely available, physicians will be called upon to interpret microvolt TWA tracings. This review seeks to establish uniform standards for the clinical interpretation of microvolt TWA tracings.

NASA Discipline Cardiopulmonary↗

Effect of Surge Current Testing on Reliability of Solid Tantalum Capacitors

Tantalum capacitors manufactured per military specifications are established reliability components and have less than 0.001% of failures per 1000 hours for grades D or S, thus positioning these parts among electronic components with the highest reliability characteristics. Still, failures of tantalum capacitors do happen and when it occurs it might have catastrophic consequences for the system. To reduce this risk, further development of a screening and qualification system with special attention to the possible deficiencies in the existing procedures is necessary. The purpose of this work is evaluation of the effect of surge current stress testing on reliability of the parts at both steady-state and multiple surge current stress conditions. In order to reveal possible degradation and precipitate more failures, various part types were tested and stressed in the range of voltage and temperature conditions exceeding the specified limits. A model to estimate the probability of post-surge current testing-screening failures and measures to improve the effectiveness of the screening process has been suggested.

Teverovsky, Alexander↗

Materials Characterization: A Primer for Solid Phase Processing Applications

The Pacific Northwest National Laboratory (PNNL) undertook the Materials Characterization, Prediction, and Control (MCPC) Laboratory Directed Research and Development (LDRD) Project to advance understanding of nuclear material processing and enable multifold acceleration in the development and qualification of new material systems produced via advanced manufacturing methods, such as solid phase processing, for use in national security and advanced energy applications (Smith 2021). As a two-year LDRD investment requiring focused research, the MCPC project applied only a subset of the wide range of available destructive and nondestructive characterization methods to provide data to the predictive modeling and data analytics tasks. The purpose of this report is to review a wide range of destructive and nondestructive characterization methods that are relevant in solid-phase processing (SPP) applications, but not necessarily applied in the MCPC Project as a guide to the planning of characterization activities in future research. Particular attention is given to measured characteristics that can correlate to other material characteristics, with a particular interest in nondestructive evaluation (NDE) that can be applied to samples obtained in the MCPC Project. Destructive examinations include tensile tests, optical and electron microscopy, micro-hardness, and residual stress tests. NDE tests include surface visual inspection, eddy current examination for cracks, 4-point potential drop, ultrasound, x-ray, and computed tomography.

36 MATERIALS SCIENCE↗

Dynamic EKG Study

The use of the dynamic EKG study as a part of periodic health examination is considered to be a valuable complement to other forms of stress testing with its ability to detect abnormal heart responses to stress stimuli. It is believed that statistical correlations of dynamic EKG findings with physical examination results contribute greatly to the understanding of cardiac abnormalities.

Fleck, R. L.↗

Some important considerations in the development of stress corrosion cracking test methods.

Discussion of some of the precaution needs the development of fracture-mechanics based test methods for studying stress corrosion cracking involves. Following a review of pertinent analytical fracture mechanics considerations and of basic test methods, the implications for test corrosion cracking studies of the time-to-failure determining kinetics of crack growth and life are examined. It is shown that the basic assumption of the linear-elastic fracture mechanics analyses must be clearly recognized and satisfied in experimentation and that the effects of incubation and nonsteady-state crack growth must also be properly taken into account in determining the crack growth kinetics, if valid data are to be obtained from fracture-mechanics based test methods.

Wei, R. P.↗

Mechanical and poroelastic behavior of porous tuff under drained and undrained conditions

A series of drained and undrained water-saturated constant mean-stress tests were performed to investigate the strength, elasticity, and poroelastic response of a water-saturated high porosity nonwelded tuff. Drained strengths are found to increase with increasing effective confining pressures. Elastic moduli increase with increasing mean stress. Undrained strengths are small due to development of high pore pressures that generate low effective confining pressures. Skempton’s values are pressure dependent and appear to reflect the onset of inelastic deformation. Permeabilities decrease after deformation from ~ 10 –14 to ~ 10 –16 m 2 and are a function of the applied confining pressure. Deformation is dominated by pore collapse, compaction, and intense microfracturing, with the undrained tests favoring microfracture-dominant deformation and the drained tests favoring compaction-dominant deformation. These property determinations and observations are used to develop/parameterize physics-based models for underground explosives testing.

58 GEOSCIENCES↗

Shot 3 Post-Shot Report: Fault Analysis of MK-X Data [Slides]

This presentation constitutes a post-shot report for the MK-X performance on Shot 3 (13 July 2022). It focuses primarily on the analysis of electrical faults which have been a persistent issue in MK-X performance and were a significant focus of the test. The MK-X is a helical flux compression generator (HFCG) that has been manufactured in a novel and very cost-effective way. Shot 3 was the fourth test in a series which began with a low initial-current-level HFCG test coupled to a dummy load (Shot 0) and then a high stress test (Shot 1) coupled to a primitive pulse forming network (PFN). Shot 0 performed close to expectation but Shot 1 had early time losses that could not be explained. As a result, Shots 2 and 3 had dual goals. Each shot looked at MK-X performance relative to the early time losses, and since the amount of current generated on the first two tests was a useful amount, we coupled to a fast R43S Ranchero flux compression generator for Shot 2 to ascertain Ranchero’s performance with higher-than-ever initial current and another PFN load. Then Shot 3 implemented a specific change to the MK-X and coupled to only a low inductance PFN load. The report shows that Shots 1-3 all have qualitatively similar losses and the change made for Shot 3 to explore losses led to even further losses. However, the PFN on shot 3 was low inductance and in spite of the losses, 32 MA was generated. This report discusses the losses seen specifically on Shot 3 and compares the electrical and camera data along with a careful comparison to 3 D MHD modeling.

42 ENGINEERING↗

IC Ku-band Impatt Amplifier

High efficiency GaAs low-high-low IMPATTs were investigated. Theoretical analyses were employed to establish a design window for the material parameters to maximize microwave performance. Single mesa devices yielded typically 2 to 3 W with 16 to 23% efficiency in waveguide oscillator test circuits. IMPATTs with high reliability Pt/TiW/Pt/Au metallizations were subjected to temperature stress, non-rf bias-temperature stress, and rf bias-temperature stress. Assuming that temperature is the driving force behind the dominant failure mechanism, a mean-time-to-failure considerably greater than 500,000 hours is indicated by the stress tests. A 15 GHz, 4W, 56 dB gain microstrip amplifier was realized using GaAs FETs and IMPATTs. Power combining using a 3 db Lange coupler is employed in the power output stage having an intrinsic power-added efficiency of 15.7%. Overall dc-to-rf efficiency of the amplifier is 10.8%. The amplifier has greater than a 250 MHz, 1 db bandwidth; operates over the 0 deg to 50 C (base plate) temperature range with less than 0.5 db change in the power output; weighs 444 grams; and has a volume of 220 cu cm.

Sokolov, V.↗

Positive electrode processing for Hughes NiH2 cells

The basic procedures were developed for the manufacture of nickel cadmium batteries. An electrochemical impregnation in an aqueous ethanol solution is used in this process. Several additional controls were instituted for production of flight electrodes, including a Hughes controlled MCD, a solution reserved exclusively for the impregnation of Hughes positive electrodes a system of complete traceability for individual electrodes, an electrical characterization test to provide information on weight and capacity at the plaque level, and a stress test to provide data on capacity, weight, and physical parameters at the electrode level.

Bleser, C. A.↗

Development of an accelerated reliability test schedule for terrestrial solar cells

An accelerated test schedule using a minimum amount of tests and a minimum number of cells has been developed on the basis of stress test results obtained from more than 1500 cells of seven different cell types. The proposed tests, which include bias-temperature, bias-temperature-humidity, power cycle, thermal cycle, and thermal shock tests, use as little as 10 and up to 25 cells, depending on the test type.

Lathrop, J. W.↗

Modeling of nonlinear constitutive relations of woven ceramic composites

The linear and nonlinear tensile behavior of SiC/SiC composites is examined. This analysis is based on the observed stress-strain behavior and damage evolution from a series of loading and unloading tensile tests. Stress distribution of the composite with transverse cracks in the transverse yarns is examined, and the nonlinearity of the composite stress-strain relation due to the presence of transverse cracks is predicted by application of a maximum failure strain criterion for the transverse yarn.

Kuo, Wen-Shyong↗

Percussive Augmenter of Rotary Drills (PARoD)

A percussive augmenter is being developed and it is designed to add ultrasonic hammering to a conventional commercial rotary drill through an adapter using a piezoelectric actuator. The combination of ultrasonic hammering and rotation creates a drill that requires low power and low axial load while providing faster penetration than conventional rotary-only drills. These characteristics make percussive augmentation of rotary drills ideal for not only planetary exploration but commercial applications as well. The purpose of this internship was to produce, test, and optimize an augmenter that drives a 2 inch diameter bit. This task was part of the percussive augmenter's phase II of an ongoing contract and it involved increasing the capability of the .25 inch version of the augmenter prototype that was developed in phase I. Due to fabrication delays of the augmenter, an extensive part of the test effort was conducted using previous rotary and hammer drill prototypes. These tests focused on drilling deep over long periods of time to provide for effective stress test of the drill. Modifications were made to the drill, its components, and the testing procedure to achieve desired borehole depths. These results were used to start initial testing on the 2 inch augmenter and provide preliminary data on the augmenter's ability to significantly improve penetration rate over conventional rotary-only drills.

rotraty hammer↗