Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “storage performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Linear optics compensation for the HEX superconducting wiggler at NSLS-II

At the NSLS-II ring, a 1.2 m long superconducting wiggler with the maximum 4.34T magnetic field has been installed at a low-β straight section (cell 27) to drive the high energy engineering X-ray scattering (HEX) beamline. To mitigate the potential performance degradation due to the linear optics distortion, a local compensation scheme was adopted and confirmed with the online beam measurement. A feedforward control to enable a dynamic compensation of the linear optics distortion was deployed. It can maintain the storage ring lattice performance when the device main coil current ramps.

36 MATERIALS SCIENCE↗

Hydrogen Storage System Modeling: Public Access, Maintenance, and Enhancements

The overall vision of this project is to provide ownership and support for maintaining existing material-based hydrogen storage systems models. This includes making models accessible to the research community through a public web page and updating and enhancing storage systems models to support material developers in assessing their materials relative to DOE vehicle-level targets. Key elements for FY24: Continue to update and enhance existing models for broader application and user-friendliness. Develop tools to evaluate the performance of hydrogen storage materials developed under HyMARC activities or other fundamental hydrogen storage materials discovery research. Expand the application of current hydrogen storage models beyond light-duty vehicles to include medium-, heavy-duty, and mining vehicles and stationary application(s). Develop models for alternatives, such as LOHCs, to material-based systems (liquefied & gaseous H2) and compare for various mobile and stationary use cases.

ENERGY STORAGE,HYDROGEN↗

Revealing the dynamics of ultrarelativistic non-equilibrium many-electron systems with phase space tomography

The description of physical processes with many-particle systems is a key approach to the modeling of numerous physical systems. For example in storage rings, where ultrarelativistic particles are agglomerated in dense bunches, the modeling and measurement of their phase-space distribution is of paramount importance: at any time the phase-space distribution not only determines the complete space-time evolution but also provides fundamental performance characteristics for storage ring operation. Here, we demonstrate a non-destructive tomographic imaging technique for the 2D longitudinal phase-space distribution of ultrarelativistic electron bunches. For this purpose, we utilize a unique setup, which streams turn-by-turn near-field measurements of bunch profiles at MHz repetition rates. To demonstrate the feasibility of our method, we induce a non-equilibrium state and show that the phase-space distribution microstructuring as well as the phase-space distribution dynamics can be observed in great detail. Our approach offers a pathway to control ultrashort bunches and supports, as one example, the development of compact accelerators with low energy footprints.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Robust Atomic-Resolution Imaging of Lithium in Battery Materials by Center-of-Mass Scanning Transmission Electron Microscopy

The performance of energy storage materials is often governed by their structure at the atomic scale. Conventional electron microscopy can provide detailed information about materials at these length scales, but direct imaging of light elements such as lithium presents a challenge. While several recent techniques allow lithium columns to be distinguished, these typically either involve complex contrast mechanisms that make image interpretation difficult or require significant expertise to perform. In this work, we demonstrate how center-of-mass scanning transmission electron microscopy (CoM-STEM) provides an enhanced ability for simultaneous imaging of lithium and heavier element columns in lithium ion conductors. Through a combination of experiments and multislice electron scattering calculations, we show that CoM-STEM is straightforward to perform and produces directly interpretable contrast for thin samples, while being more robust to variations in experimental parameters than previously demonstrated techniques. As a result, CoM-STEM is positioned to become a reliable and facile method for directly probing all elements within energy storage materials at the atomic scale.

25 ENERGY STORAGE↗

Design and performance assessment of a dual-mode latent thermal storage integrated heat pump across multiple climate zones

The electrification of space cooling and heating systems risks overloading the existing electrical grid during peak hours. Heat pumps integrated with thermal energy storage (HP-TES) offer a promising solution by shifting peak loads to off-peak hours, reducing grid strains. This work presents the design and assessment of a dual-mode HP-TES that uses a single 22°C phase-change material (PCM) as a heat source or sink in heating and cooling modes, respectively. Performance assessment was conducted using Modelica-based transient models, and full-year simulations were conducted across eight US climate zones using typical weather data. Two HP-TES performance metrics: peak energy reduction and recharge energy increases, were defined by comparing HP-TES energy consumption with base HP peak consumptions. Annual heating demand reductions (40–65%) exceeded cooling demand reductions (15–20%) due to the elimination of peak-hour backup heating. Cooling mode recharge energy requirements (0–10%) were reduced in locations with lower summer nighttime temperatures, while heating recharge requirements were lower than the high base-peak energy demand from backup heating. Simplified rapid methods that were 10 7 times faster than annual simulations were developed to predict seasonal cooling and heating energy reductions, and recharge energy requirements, with maximum deviations of ±2.5% and ±3.5% points. These methods enabled rapid parametric studies that identified optimal location-specific PCM temperatures between 22°C and 27°C, highlighting the need to consider both discharge and recharge energy requirements to achieve sustainable, energy-efficient peak load shifting across various climate zones.

25 ENERGY STORAGE↗

Savings in Action: Lessons from Observed and Modeled Residential Solar Plus Storage Systems [Slides]

The study performed two related analyses using data from a new-construction residential community equipped with rooftop solar and storage (S+S) in Arizona. The study analyzed the factors that determine customer electricity cost savings from S+S adoption. The research compared the Arizona case study data to modeled system performance to understand how models deviate from real-world outcomes. Based on these findings, NREL explored ways to improve such models and, conversely, use modeled results to suggest improvements to S+S dispatches.

14 SOLAR ENERGY↗

Concrete Thermal Energy Storage Enabling Flexible Operation without Coal Plant Cycling

The work described in this report is responsive to the Office of Fossil Energy program “Energy Storage for Fossil Power Generation.” The pilot plant built as a result of this project demonstrated the feasibility and performance of a concrete thermal energy storage (CTES) system integrated with a supercritical coal power plant. The 10 MWh electrical (>25 MWh thermal) CTES unit, developed by Storworks Power, was designed to enable flexible operation of coal plants without cycling damage. The project's key technical achievements showcase a significant advancement in energy storage technology. A modular CTES system using 42 “Bolderblocs” units was successfully designed and constructed at Alabama Power’s Plant Gaston Unit 5, with each block containing embedded stainless-steel coils in specialized, cost-effective high-temperature concrete. The system interfaced seamlessly with the plant's 3500 psig (241 barg), 1000°F (538°C) supercritical steam, demonstrating operational flexibility. Over 86 full cycles, the CTES exhibited rapid charging and discharging capabilities, effectively mimicking steam turbine feed conditions and handling varying load profiles and storage durations. Performance validation confirmed the system's ability to consistently meet design target steam conditions of 75 bar-a and ~400°C for nominal baseline discharge. The concrete material withstood repeated thermal cycling without degradation, validating earlier lab-scale tests. Integration of balance of plant components, including a condensate management system with storage tank and air-cooled condenser, minimized plant interfaces and water consumption. A robust control scheme ensured safe, automated operation across various scenarios. Key learnings from the project were invaluable: 1. Initial concrete drying and commissioning procedures were refined for future deployments, enhancing efficiency in subsequent installations. 2. System flexibility exceeded expectations, with rapid response to changing conditions. 3. Design improvements were identified including optimized insulation and piping that will enhance overall system efficiency in future deployments 4. Full cycle thermal roundtrip efficiencies exceeded 88%. While the roundtrip electrical efficiency was somewhat limited by known challenges using input steam, such constraints may be mitigated by swapping steam for hot air as thermal input. 5. A summary of key performance parameters for the pilot test and predicted performance of a full scale commercial system with specified improvements determined from the pilot are shown in Section 8. The project faced challenges, including COVID-19 delays and host plant availability constraints. However, these were overcome through adaptive planning and execution. The successful management of these obstacles demonstrated the resilience and adaptability of the project team and the robustness of the CTES technology. This successful pilot demonstrates the potential for CTES to enhance coal plant flexibility, supporting grid stability as renewable penetration increases. The validated design and operational data provide a solid foundation for scaling up to utility-scale implementations, potentially transforming how thermal plants operate in evolving energy landscapes. The system's ability to rapidly respond to changing grid conditions while maintaining high efficiency makes it a promising solution for balancing intermittent renewable energy sources. Furthermore, the project highlighted the potential for even greater efficiencies in future iterations. The use of air as an input medium could potentially eliminate the limitations observed with steam input, opening new possibilities for energy storage applications beyond coal plant integration. In conclusion, this pilot project not only achieved its primary goals but also uncovered additional benefits and potential applications of the CTES technology. It represents a significant step forward in addressing the challenges of grid stability and flexibility in an increasingly renewable-driven energy landscape.

01 COAL, LIGNITE, AND PEAT↗

Optimization of Energy Storage System Economics and Controls by Incorporating Battery Degradation Costs in REopt

The use of stationary electrochemical energy storage systems utilizing lithium-ion batteries has increased rapidly as the production scale and price for lithium-ion batteries has decreased. These energy storage systems are crucial for maintaining grid resiliency, especially for grids operating with high penetration of renewable energy generation assets or for with a variety of distributed energy generation and storage systems. One challenging factor for the development of battery energy storage systems is estimating the proper sizing, in terms of both power and energy, that minimizes total costs over the lifetime of the systems; this calculation is difficult in simple cases, where a battery is costed independently, but is extremely challenging when building loads and electrical generation by photovoltaic resources are also considered. REopt is a techoeconomic optimization tool developed by NREL to address these challenges. Previously, battery degradation has been priced by simply assuming a 10-year replacement schedule for battery systems. However, this does not account for varying degradation trends observed across real-world batteries, or allow for batteries to be operated in a degradation-aware manner that optimizes battery dispatch based on operating costs. This work incorporates a battery life model into REopt. This battery life model is simple, so that it may be solvable within the constrains of a mixed-integer linear optimization problem, but is fit to accelerated aging data recorded in the lab. To achieve the best possible accuracy for lifetime estimates given these constraints, parameters for the battery life model in REopt are estimated by fitting 20-year simulations of battery life after identifying state-space battery degradation model from accelerated aging data. Comparisons of battery life predicted in REopt and from the state-space battery degradation model to ensure validity of lifetime estimates made by REopt. Battery life and cost is optimized by controlling three decision to minimize system life cost: battery sizing, daily state-of-charge, and daily energy-throughput. The cost of battery degradation as a function of these control variables is then estimated assuming two possible maintenance strategies: replacement, where the entire battery system is replaced if cell reach an end-of-life capacity threshold; and augmentation, which establishes a fund to pay for continual purchase of new batteries to maintain the initial energy capacity of the system. These two strategies offer conservative (for replacement) and optimistic (for augmentation) bounds for total system cost. The degradation cost incurred by these strategies is then used to control battery dispatch decisions, operating the battery in a degradation-aware manner that maximizes battery lifetime while also providing energy when favorable. Because the mixed-integer linear program has perfect foresight of future energy needs, batteries with degradation costs are always operated using 'just-in-time' charging, which is unrealistic, as no energy is left in the storage system to perform other energy services or to serve as emergency back-up power. To combat this, an inequality constraint on the average annual state-of-charge is imposed, and the sensitivity of system cost to average stored energy, e.g., the cost of system resiliency, can be quantified. Analysis of results has several conclusions, for instance, oversizing of battery storage systems is not a cost burden when battery storage is an optimal solution, as any additional battery capacity can simply be utilized to avoid costs of purchasing energy from a utility.

battery↗

Metal-Organic Frameworks (MOFs) Containing Frustrated Lewis Pairs (FLP) for H 2 Storage at Ambient Temperature

This final technical report summarizes the key accomplishments of the HyMarc Seedling project to develop new materials based on metal-organic framework (MOF) incorporated with frustrated Lewis pairs (FLP) termed as FLP@MOF, as next-generation of hydrogen storage sorbent that can meet or exceed DOE’s 2025 performance target of hydrogen storage gravimetric density of 5.5 wt.% and volumetric density of 0.040 kg H 2 /L. The project was carried out by the PI Shengqian Ma at the University of North Texas (UNT) along with Argonne National Laboratory (ANL) to develop FLP@MOF systems that exhibit high hydrogen storage capacity at ambient temperature under pressure <100 bar, as well as to obtain improved fundamental understanding of hydrogen adsorption mechanism in FLP@MOF system.

08 HYDROGEN↗

Electrical Energy Storage Data Submission Guidelines

Energy storage technologies are positioned to play a substantial role in power delivery systems. They are being touted as an effective new resource to maintain reliability and allow for increased penetration of renewable energy. However, due to their relative infancy, there is a lack of knowledge on how these resources truly operate over time. Data analysis can help ascertain the operational and performance characteristics of these emerging technologies. Rigorous testing and data analysis are important for all stakeholders to ensure a safe, reliable system that performs predictably on a macro level. Standardizing testing and analysis approaches to verifying the performance of energy storage devices, equipment, and systems when integrating them into the grid will improve the understanding and benefit of energy storage over time from technical and economic vantage points. Demonstrating the life-cycle value and capabilities of energy storage systems begins with the data the provider supplies for analysis. After review of energy storage data received from several providers, it has become clear that some of these data are inconsistent and incomplete, raising the question of their efficacy for robust analysis. This report reviews and proposes general guidelines such as sampling rates and data points that providers must supply for robust data analysis to take place. Consistent guidelines are the basis of the proper protocol and ensuing standards to (a) reduce the time it takes data to reach those who are providing analysis; (b) allow them to better understand the energy storage installations; and (c) enable them to provide high-quality analysis of the installations. This report is intended to serve as a starting point for what data points should be provided when monitoring. As battery technologies continue to advance and the industry expands, this report will be updated to remain current.

25 ENERGY STORAGE↗

Revolutionizing Porous Liquids: Stabilization and Structural Engineering Achieved by a Surface Deposition Strategy

Facile approaches capable of constructing stable and structurally diverse porous liquids (PLs) that can deliver high-performance applications are a long-standing, captivating, and challenging research area that requires significant attention. Here, in this work, a facile surface deposition strategy is demonstrated to afford diverse type III-PLs possessing ultra-stable dispersion, external structure modification, and enhanced performance in gas storage and transformation by leveraging the expeditious and uniform precipitation of selected metal salts. The Ag(I) species-modified zeolite nanosheets are deployed as the porous host to construct type III-PLs with ionic liquids (ILs) containing bromide anion , leading to stable dispersion driven by the formation of AgBr nanoparticles. The as-afforded type-III PLs display promising performance in CO 2 capture/conversion and ethylene/ethane separation. Property and performance of the as-produced PLs can be tuned by the cation structure of the ILs, which can be harnessed to achieve polarity reversal of the porous host via ionic exchange. The surface deposition procedure can be further extended to produce PLs from Ba(II)-functionalized zeolite and ILs containing [SO 4 ] 2– anion driven by the formation of BaSO 4 salts. The as-produced PLs are featured by well-maintained crystallinity of the porous host, good fluidity and stability, enhanced gas uptake capacity, and attractive performance in small gas molecule utilization.

36 MATERIALS SCIENCE↗

Topology Optimization of Curved Electrodes with Suggested Simplified Corrugated Designs

The demand for space-efficient energy storage, from grid to device scale, has soared with the rapid electrification of society. To increase energy density while maintaining high rate performance, shaping electrodes has been shown to be an effective strategy. Computational optimization can suggest designs that improve energy storage performance; however, generated designs are often complex, leading to manufacturing challenges. Additionally, most optimization is typically conducted in standard rectangular domains, whereas some applications, such as in the aerospace industry or in consumer electronics, may benefit from optimized electrodes that fit in a nonstandard form factor. Here, in this work, we use topology optimization to design capacitive full-cell electrodes in a curved domain. We propose a simplified corrugated electrode design based on the optimization results and show that the energy stored in the simplified design is only reduced by about 5–27% when compared to that in the fully optimized design, with more deviation occurring when ionic transport in the porous electrode is particularly impeded. Overall, we find that these simplified designs are promising, particularly given the more conventional manufacturing techniques required, and have a 42–369% increase in energy stored compared to monolithic electrodes.

Energy - Storage↗

Time-Lapse Gravity Monitoring of CO2 Migration Based on Numerical Modeling of a Faulted Storage Complex

In this study, the performance of both surface and borehole time-lapse gravity monitoring to detect CO2 leakage from a carbon storage site is evaluated. Several hypothetical scenarios of CO2 migration in a leaky fault, and thief zones at different depths at the Kimberlina site (California, USA) constitute the basis of the approach. The CO2 displacement is simulated using the TOUGH2 simulator applied to a detailed geological model of the site. The gravity responses to these CO2 plumes are simulated using forward modeling with sensors at ground surface and in vertical boreholes. Results of inversion on one scenario are also presented. The surface-based gravity responses obtained for the different leakage scenarios demonstrate that leakage can be detected at the surface in all the scenarios but the time to detection is highly variable (10 to 40 years) and dependent on the detection threshold considered. Borehole measurements of the vertical component of gravity provide excellent constrains in depth when they are located in proximity of the density anomaly associated with the presence of CO2, thus discriminating multiple leaks in different thief zones. Joint inversion of surface and borehole data can bring valuable information of the occurrence of leakages and their importance by providing a reasonable estimate of mass of displaced fluids. This study demonstrates the importance of combining multiphase flow simulations with gravity modeling in order to define if and when gravity monitoring would be applicable at a given storage site.

Time-lapse gravity monitoring, leak detection, CCS↗