Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “steam flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Implementing a control application on an FPGA Platform - 356

Today, many I and C system suppliers propose FPGA-based I and C platforms. In that context, EDF has set up a project to assess the use of such platforms for safety-related systems and to enhance EDF's ability to manage this technology for the upgrade of existing I and C systems or for new constructions. One aim of the project is to assess the adequacy of these platforms for the development of control functions. This paper presents the development of a case study on a Radiy FPGA-based platform in a Hardware-In-the-Loop configuration, and the comparison with a Dymola Model-In-the-Loop and a Siemens T2000 S7 Hardware-In-the-Loop approach. The case study is a part of the level control of steam generators of French PWR NPP. The control flow diagram uses complex analog elementary blocks coded with fixed point format for the analog values. The use of IP cores of the FPGA supplier was avoided to enable a complete mastership of the VHDL code, to provide evidence of compliance with safety-related requirements, and to allow porting this code to another FPGA platform. The case study has highlighted the specificity of using a FPGA, and has shown that a complex control application in a FPGA-based PLC presents no major differences in precision and response time with a processor-based PLC. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Method of thermally-stabilizing an oxygen transport membrane-based reforming system

A method of operating an oxygen transport membrane based reforming system employing one or more packs of thermally coupled panels of reformer tubes and oxygen transport membrane ("OTM") reactors close to thermo-neutral point is provided. The method produces syngas by converting a hydrocarbon-containing feed, such as natural gas in the reformer tubes of a pack by endothermic steam reforming reactions. The heat required for endothermic reforming reactions is provided by exothermic oxidizing reactions occurring inside the OTM reactors of the pack. At a thermo-neutral point the heat released by exothermic reactions matches the heat required to support endothermic reactions and heat losses in the pack. The method modulates the flow rate of hydrocarbon-containing feed and/or steam-to-carbon ratio of the combined feed to the pack to maintain the surface temperature of oxygen transport membrane reactors below a target maximum temperature. The syngas product oxygen-to-carbon ratio is maintained within a desired target range such that the OTM based reforming system is operated close to thermo-neutral point.

42 ENGINEERING↗

Treatment of Irradiated Graphite from French Bugey Reactor - 13424

Beginning in 2009, in order to determine an alternative to direct disposal for decommissioned irradiated graphite from EDF's Bugey NPP, Studsvik and EDF began a test program to determine if graphite decontamination and destruction were practicable using Studsvik's thermal organic reduction (THOR) technology. The testing program focused primarily on the release of C-14, H-3, and Cl-36 and also monitored graphite mass loss. For said testing, a bench-scale steam reformer (BSSR) was constructed with the capability of flowing various compositions of gases at temperatures up to 1300 deg. C over uniformly sized particles of graphite for fixed amounts of time. The BSSR was followed by a condenser, thermal oxidizer, and NaOH bubbler system designed to capture H-3 and C-14. Also, in a separate series of testing, high concentration acid and peroxide solutions were used to soak the graphite and leach out and measure Cl-36. A series of gasification tests were performed to scope gas compositions and temperatures for graphite gasification using steam and oxygen. Results suggested higher temperature steam (1100 deg. C vs. 900 deg. C) yielded a practicable gasification rate but that lower temperature (900 deg. C) gasification was also a practicable treatment alternative if oxygen is fed into the process. A series of decontamination tests were performed to determine the release behavior of and extent to which C-14 and H-3 were released from graphite in a high temperature (900-1300 deg. C), low flow roasting gas environment. In general, testing determined that higher temperatures and longer roasting times were efficacious for releasing H-3 completely and the majority (80%) of C-14. Manipulating oxidizing and reducing gas environments was also found to limit graphite mass loss. A series of soaking tests was performed to measure the amount of Cl-36 in the samples of graphite before and after roasting in the BSSR. Similar to C-14 release, these soaking tests revealed that 70-80% Cl-36 is released during roasting tests. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Design Evolution and Verification of the A-3 Chemical Steam Generator

Following is an overview of the Chemical Steam Generator system selected to provide vacuum conditions for a new altitude test facility, the A-3 Test Stand at Stennis Space Center (SSC) in Bay St. Louis, MS. A-3 will serve as NASA s primary facility for altitude testing of the J-2X rocket engine, to be used as the primary propulsion device for the upper stages of the Ares launch vehicles. The Chemical Steam Generators (CSGs) will produce vacuum conditions in the test cell through the production and subsequent supersonic ejection of steam into a diffuser downstream of the J-2X engine nozzle exit. The Chemical Steam Generators chosen have a rich heritage of operation at rocket engine altitude test facilities since the days of the Apollo program and are still in use at NASA White Sands Test Facility (WSTF) in New Mexico. The generators at WSTF have been modified to a degree, but are still very close to the heritage design. The intent for the A-3 implementation is to maintain this heritage design as much as possible, making minimal updates only where necessary to substitute for obsolete parts and to increase reliability. Reliability improvements are especially desired because the proposed system will require 27 generators, which is nine times the largest system installed in the 1960s. Improvements were suggested by the original design firm, Reaction Motors, by NASA SSC and NASA WSTF engineers, and by the A-3 test stand design contractor, Jacobs Technology, Inc. (JTI). This paper describes the range of improvements made to the design to date, starting with the heritage generator and the minor modifications made over time at WSTF, to the modernized configuration which will be used at A-3. The paper will discuss NASA s investment in modifications to SSC s E-2 test facility fire a full-scale Chemical Steam Generator in advance of the larger steam system installation at A-3. Risk mitigation testing will be performed in early 2009 at this test facility to verify that the CSGs operate as expected. The generator which will undergo this testing is of the most recent A-3 configuration, and will be instrumented far in excess of what is normally required for operation. The extra data will allow for easier troubleshooting and more complete knowledge of expected generator performance. In addition, the early testing will give SSC personnel experience in operating the CSG systems, which will expedite the process of installation and activation at A-3. Each Chemical Steam Generator is supported by a complement of valves, instruments, and flow control devices, with the entire assembly called a "module." The generators will be installed in groups of three, historically called "units". A module is so called because of its modular ability to be replaced or serviced without disturbing the other two modules installed on the same unit. A module is pictured in Figure 1, shown with its generator secured by white bands in its shipping (vs. installed) configuration. The heritage system at WSTF is composed of a single unit (three generator modules), pictured in Figure 2 as it was installed in 1965. In contrast, A-3 will have nine units operating in parallel to achieve vacuum conditions appropriate for testing the J-2X engine. Each of the combustors operates in two modes and achieves the so-called "full-steam" mode after all three of its stages ignite. Ignition of the first stage is achieved by exciting a spark plug; the second stage and main stage are lit by the flame front of the previous stage. The main stage burns approximately 97% of the total propellant flow and uses the heat energy to vaporize water into superheated steam. While the main stage remains unlit, the combustor is in so-called "idle" mode. In the WSTF system, this idle mode is not optimized for water usage, and does not need to be, as the water is pumped from a large reservoir. The water supply at A-3 will be contained in tanks with finite volume, so water optimization is preferred for the modnized configuration. Multiple solutions for this issue have been proposed, with the leading concept being a change to the operational definition of "idle mode," with the generator running in a lower heat flux condition.

Kirchner, Casey K.↗

Comparison of Simultaneous PIV and Hydroxyl Tagging Velocimetry in Low Velocity Flows

Hydroxyl tagging velocimetry (HTV) is a molecular tagging velocimetry (MTV) technique that relies on the photo- dissociation of water vapor into OH radicals and their subsequent tracking using laser-induced fluorescence. At ambient temperature in air, the OH species lifetime is about 50 micro-s. The feasibility of using HTV for probing low- speed flows (a few m/s) is investigated by using an inert, heated gas as a means to increase the OH species lifetime. Unlike particle-based techniques, MTV does not suffer from tracer settling, which is particularly problematic at low speeds. Furthermore, the flow needs to be seeded with only a small mole fraction of water vapor, making it safer for both the user and facilities than other MTV techniques based on corrosive or toxic chemical tracers. HTV is demonstrated on a steam-seeded nitrogen jet at approximately 75 C in the laminar (Umean=3.31 m/s, Re=1,540), transitional (Umean=4.48 m/s, Re=2,039), and turbulent (Umean=6.91 m/s, Re=3,016) regimes at atmospheric pressure. The measured velocity profiles are compared with particle image velocimetry (PIV) measurements performed simultaneously with a second imager. Seeding for the PIV is achieved by introducing micron-sized water droplets into the flow with the steam; the same laser sheet is used for PIV and HTV to guarantee spatial and temporal overlap of the data. Optimizing each of these methods, however, requires conflicting operating conditions: higher temperatures benefit the HTV signals but reduce the available seed density for the PIV through evaporation. Nevertheless, data are found to agree within 10% for the instantaneous velocity profiles and within 5% for the mean profiles and demonstrate the feasibility of HTV for low-speed flows at moderate to high temperatures.

Andre, Matthieu A.↗

CFD Predictions of Severe Accident Natural Circulation Flows in a Combustion Engineering PWR

Computational fluid dynamics (CFD) is used to predict natural circulation flows between a reactor vessel upper plenum and a steam generator during specific severe accidents in a pressurized-water reactor (PWR). The predictions are based on a model for a simplified Combustion Engineering (CE) design. This work is part of a larger study to investigate the potential for severe accident induced steam generator (SG) tube failures in PWRs being conducted by the U.S. Nuclear Regulatory Commission Office of Nuclear Regulatory Research. The CFD model builds upon the lessons learned from previous studies of a generic Westinghouse PWR under similar conditions. The CE SG is significantly larger than the Westinghouse design and geometric differences are expected to reduce the mixing and increase the potential thermal challenge to the SG tubes. The CFD predictions are utilized to improve the basis for simplified flow and mixing models applied in one-dimensional severe accident codes. Parameters are determined to support system code modeling of hot leg and SG inlet plenum mixing, hot leg and SG tube bundle flow rates, and tube inlet temperatures. This updated modeling uses boundary conditions obtained from system analysis code predictions of severe accident behavior in a CE PWR. Model refinements include an improved tube bundle representation and improvements to the thermal boundary conditions. Results indicate less mixing and higher tube inlet temperatures for the CE design compared to previous Westinghouse studies. (author)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Rocket Engine Altitude Simulation Technologies

John C. Stennis Space Center is embarking on a very ambitious era in its rocket engine propulsion test history. The first new large rocket engine test stand to be built at Stennis Space Center in over 40 years is under construction. The new A3 Test Stand is designed to test very large (294,000 Ibf thrust) cryogenic propellant rocket engines at a simulated altitude of 100,000 feet. A3 Test Stand will have an engine testing chamber where the engine will be fired after the air in the chamber has been evacuated to a pressure at the simulated altitude of less than 0.16 PSIA. This will result in a very unique environment with extremely low pressures inside a very large chamber and ambient pressures outside this chamber. The test chamber is evacuated of air using a 2-stage diffuser / ejector system powered by 5000 lb/sec of steam produced by 27 chemical steam generators. This large amount of power and flow during an engine test will result in a significant acoustic and vibrational environment in and around A3 Test Stand.

Woods, Jody L.↗

Influence of pre-hydriding and quench on embrittlement of E110 alloy under LOCA conditions

The aims of present work were to investigate the corrosion behavior and residual ductility of pre-hydrided E110 alloy under LOCA conditions including the influence of cooling rate. The fragments of unirradiated and pre-hydrided cladding (9,5*8,33 mm with a 10 mm length) were used as samples. The claddings were made from an E110 sponge based alloy (finish polishing). The hydrogen concentration varied from 5 (as received) to 800 wppm. As a result of pre-hydriding δ- hydrides of zirconium have been formed into cladding material. Corrosion tests were carried out at temperatures 1100 and 1200 C. degrees in a steam (80 mg/s) and argon (25 ml/s) mixture flow. The samples were cooled by 2 regimes: the first one is cooling in the cold zone of test facility with rate about 20 C. degrees/s, the second is cooling in the cold zone of test facility with rate about 20 C. degrees/s from test temperature to 800 C. degrees and quench by dropping in to the water. The change of a sample mass was determined as a difference between initial sample mass and its mass after oxidation. The mechanical tests of oxidized claddings in a diametrical direction were carried out with the use of a universal tension testing machine at a steady deformation rate of 1 mm/min at 135 C. degrees. The investigations have established the following. The initial concentration of hydrogen has no effects on the oxidation kinetics, while the oxidation kinetics are parabolic and the breakaway oxidation is not observed. The oxide films on cladding surfaces are black and shining. There are no cracks, visual spots and peelings. The residual ductility of oxidized samples decreases with the increase of hydrogen concentration. The residual ductility of slow cooled claddings is higher than residual ductility of quenched claddings. The limiting value of ECR (Equivalent Cladding Reacted) corresponding to ductile-brittle transition as function of initial hydrogen content was evaluated. The value of residual ductility 2% was used as a ductile-brittle threshold. The limiting value of ECR for as-received E110 alloy is 18% and it decreases slowly to 15% with hydrogen content rising to 350 wppm. At hydrogen content of about 350 - 400 wppm there is a rapid change of limiting value of ECR from 15% to 8 %. At hydrogen content from 400 to 800 wppm the limiting value of ECR decreases from 8% to 3%. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Influence of the Length of a Torch Tongue on Heat Flow in a Burner Device

Results of mathematical modeling of the burner torch of the furnaces of steam boilers with radiating cylindrical gas volumes are presented. As a result of modeling it is established that with a short torch tongue, the heat flows to the burner device can be significant and the service life of the burners reduced. By means of calculations it is established that with a 1.5 – 2-fold increase in the length of the torch tongue at constant power, heat flow decreases 2 – 3-fold in the burner device and the useful life of the latter increases to 10 years and more.

42 ENGINEERING↗

Fluid characterization using acoustics

A measurement system and a method for determining steam quality (i.e. vapor mass fraction) measurements of multiphase fluid flowing through pipes are described. An acoustic sensor device consists of an acoustic transmitter and an acoustic receiver that are designed to be attached to a pipe. The acoustic transmitter and the acoustic receiver are exposed to an interior space of the pipe through openings in a wall of the pipe. Acoustic waves generated by the transmitter and captured by the receiver traverse the multiphase fluid flowing into the pipe. Swept-frequency acoustic interferometry (SFAI) technique is used to measure ultrasonic acoustic properties of a fluid. Machine-learning techniques based on principal component analysis, support vector machine regression and support vector machine classification are used for determining steam quality.

47 OTHER INSTRUMENTATION↗

Simulation of water vapor condensation on LOX droplet surface using liquid nitrogen

The formation of ice or water layers on liquid oxygen (LOX) droplets in the Space Shuttle Main Engine (SSME) environment was investigated. Formulation of such ice/water layers is indicated by phase-equilibrium considerations under conditions of high partial pressure of water vapor (steam) and low LOX droplet temperature prevailing in the SSME preburner or main chamber. An experimental investigation was begun using liquid nitrogen as a LOX simulant. A monodisperse liquid nitrogen droplet generator was developed which uses an acoustic driver to force the stream of liquid emerging from a capillary tube to break up into a stream of regularly space uniformly sized spherical droplets. The atmospheric pressure liquid nitrogen in the droplet generator reservoir was cooled below its boiling point to prevent two phase flow from occurring in the capillary tube. An existing steam chamber was modified for injection of liquid nitrogen droplets into atmospheric pressure superheated steam. The droplets were imaged using a stroboscopic video system and a laser shadowgraphy system. Several tests were conducted in which liquid nitrogen droplets were injected into the steam chamber. Under conditions of periodic droplet formation, images of 600 micron diameter liquid nitrogen droplets were obtained with the stroboscopic video systems.

Powell, Eugene A.↗

Exergy and Economic Analysis of Catalytic Coal Gasifiers Coupled With Solid Oxide Fuel Cells

The National Energy Technology Laboratory (NETL) has undertaken a review of coal gasification technologies that integrate with solid oxide fuel cells (SOFC) to achieve system efficiencies near 60% while capturing and sequestering >90% of the carbon dioxide. One way to achieve an overall system efficiency of greater than 60% is in a power plant in which a catalytic coal gasifier produces a syngas with a methane composition of roughly 25% on a dry volume basis and this is sent to a SOFC, with CO{sub 2} capture occurring either before or after the SOFC. Integration of a catalytic gasifier with a SOFC, as opposed to a conventional entrained flow gasifier, is improved due to (a) decreased exergy destruction inside a catalytic, steam-coal gasifier producing a high-methane content syngas, and (b) decreased exergy destruction in the SOFC due to the ability to operate at lower air stoichiometric flow ratios. For example, thermal management of the SOFC is greatly improved due to the steam-methane reforming in the anode of the fuel cell. This paper has two main goals. First, we converted the levelized cost of electricity (LCOE) estimates of various research groups into an average internal rate of return on investment (IRR) in order to make comparisons between their results, and to underscore the increased rate of return on investment for advanced integrated gasification fuel cell systems with carbon capture & sequestration (IGFC-CCS) compared with conventional integrated gasification combined cycle (IGCC-CCS) systems and pulverized coal combustion (PCC-CCS) systems. Using capital, labor, and fuel costs from previous researchers and using an average price of baseload electricity generation of $61.50 / MW-hr, we calculated inflation-adjusted IRR values of up to 13%/yr for catalytic gasification with pressurized fuel cell and carbon dioxide capture and storage (CCS), whereas we calculate an IRR of ~4%/yr and ~2%/yr for new, conventional IGCC-CCS and PCC-CCS, respectively. If the carbon dioxide is used for enhanced oil recovery rather than for saline aquifer storage, then the IRR values improve to 16%/yr, 10%/yr, and 8%/yr, respectively. For comparison, the IRR of a new conventional IGCC or PCC power plant without CO{sub 2} capture are estimated to be 11%/yr and 15.0%/yr, respectively. Second, we conducted an exergy analysis of two different configurations in which syngas from a catalytic gasifier fuels a SOFC. In the first case, the CO{sub 2} is captured before the SOFC, and the anode tail gas is sent back to the catalytic gasifier. In the second case, the anode tail gas is oxy-combusted using oxygen ion ceramic membranes and then CO{sub 2} is captured for sequestration. In both cases, we find that the system efficiency is greater than 60%. These values compare well with previous system analysis. In future work, we plan to calculate the IRR of these two cases and compare with previous economic analyses conducted at NETL.

01 COAL, LIGNITE, AND PEAT↗

Comparing Velocity Profiles Along the Rod Length of a Helical Coil Steam Generator Model

A model of a specific type of tube and shell heat exchanger, the helical coil steam generator (HCSG), was designed and constructed to study multiple fluidic properties that attribute to the efficiency of the heat transfer it provides. Tube and shell heat exchangers are currently used throughout industry in chemical, power and petroleum engineering. Most commonly, a primary flow is circulated through a shell, while the secondary flow is run through several small tubes that are bundled together. Methods to increase the heat transfer between the two flows include adding baffles to force shell side flow over more tubes, fins added in-between layers of tubes and passing tubes multiple times through the shell to increase heat exchanger effectiveness. The HCSG incorporates many of the proposed methods but also relies on a complex geometry to increase the heat transfer between tube and shell side flow. In an area where cost effectiveness is favorable, such as inside a nuclear reactor, helically banked steam generators makes extensive use of the room with no sharp tube bends. This increases the pressure loss on the secondary flow and can solve potential temperature manufacturing issues at the welds of junctions. Additionally, they have exhibited pure cross flow behaviors with high heat transfer coefficients and axial temperature profiles that correspond to pure counter-flow with high mean temperature differences. Early work showed that helical banks can have a significant increase of 16 to 43% higher heat transfer coefficient than straight pipe heat exchangers. While many previous studies have looked at the heat transfer, pressure drop and flow fields of a tube and shell heat exchanger, they all focus on tube bundles that are either in-line or staggered. The early flow visualization studies on these types of bundle arrangements reported that attached eddies were formed alternatively behind each of the rods and were occasionally dragged into the main stream of shell side flow. Later studies suggested that observable periodic vortex shedding was dependent on geometry. Experimental data taken using techniques such as laser Doppler anemometry (LDV) by Simonin and Barcouda (1986) as mentioned in Hassan (2002), hot-wire anemometry with Tsuchida (1982) and particle image velocimetry (PIV) conducted by researchers as late as 2007 have been used to characterize turbulent flow and distinguish flow field structures within in-line and staggered tube bundles. By studying these flow field structures, their contribution to fluidic properties such as heat transfer efficiency and pressure drop can be characterized effectively. Literature review lead to a design that incorporated five layers of coils wrapped around one another. The outermost and middle layers of tubes coiled at a specific pitch in a clockwise direction while the other two layers coiled counterclockwise. The proposed design incorporates a constantly changing lateral pitch ratio, a, between adjacent rods. The constructed test section isolates a single interface between two adjacent coiling rod bundles of twelve rods. Three distinct cross sectional planes along the rod bundles were looked at to study the effect of the local geometry to flow fields, Section A, B and C. Particle Image Velocimetry (PIV) frames of 896 x 848 pixels were captured at each section across a specific height. Profiles of mean velocity fields for each section are compared and discussed as possible features of the changing lateral pitch ratio.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Large Eddy Simulations for a Helical Coil Steam Generator

The desire for scalable power plants in remote locations and specialized applications has brought forth the small modular reactor (SMR). Now, smaller light water reactors are seen as viable means for meeting global energy requirements. Generally, straight or U-shape tubes are used to exchange heat from the primary to secondary coolant; however this is not ideal when size is a criterion. Helical coil steam generators (HCSGs) are advantageous for SMRs due to their enhanced heat transfer in compact spaces. Still, there is the concern of safety as steam generator tubes could rupture due to vibrations and fatigue on the material. Understanding flow characteristics and quantifying pressures for these tubes are important components for the design of safety and efficiency in these steam generators. The current study uses the spectral element computational fluid dynamic (CFD) code, Nek5000, to develop large eddy simulations (LES) for validation against experiments that will be conducted at Texas A and M University. Time-averaged pressure data will be compared with pressure tap readings, and velocity profile with particle image velocimetry (PIV) measurements. The presented preliminary results investigate the differences between 5.-, 7.-, and 9.-order polynomial simulations. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Integrating catalytic coal gasifiers with solid oxide fuel cells

A review was conducted for coal gasification technologies that integrate with solid oxide fuel cells (SOFC) to achieve system efficiencies near 60% while capturing and sequestering >90% of the carbon dioxide [1-2]. The overall system efficiency can reach 60% when a) the coal gasifier produces a syngas with a methane composition of roughly 25% on a dry volume basis, b) the carbon dioxide is separated from the methane-rich synthesis gas, c) the methane-rich syngas is sent to a SOFC, and d) the off-gases from the SOFC are recycled back to coal gasifier. The thermodynamics of this process will be reviewed and compared to conventional processes in order to highlight where available work (i.e. exergy) is lost in entrained-flow, high-temperature gasification, and where exergy is lost in hydrogen oxidation within the SOFC. The main advantage of steam gasification of coal to methane and carbon dioxide is that the amount of exergy consumed in the gasifier is small compared to conventional, high temperature, oxygen-blown gasifiers. However, the goal of limiting the amount of exergy destruction in the gasifier has the effect of limiting the rates of chemical reactions. Thus, one of the main advantages of steam gasification leads to one of its main problems: slow reaction kinetics. While conventional entrained-flow, high-temperature gasifiers consume a sizable portion of the available work in the coal oxidation, the consumed exergy speeds up the rates of reactions. And while the rates of steam gasification reactions can be increased through the use of catalysts, only a few catalysts can meet cost requirements because there is often significant deactivation due to chemical reactions between the inorganic species in the coal and the catalyst. Previous research into increasing the kinetics of steam gasification will be reviewed. The goal of this paper is to highlight both the challenges and advantages of integrating catalytic coal gasifiers with SOFCs.

01 COAL, LIGNITE, AND PEAT↗

Performance of the Fluidized Bed Steam Reforming Product Under Hydraulically Unsaturated Conditions

Currently, several candidates for secondary waste immobilization at the Hanford site in the State of Washington, USA are being considered. To demonstrate the durability of the product in the unsaturated Integrated Disposal Facility (IDF) at the site, a series of tests have been performed one of the candidate materials using the Pressurized Unsaturated Flow (PUF) system. The material that was tested was the Fluidized Bed Steam Reformer (FBSR) granular product and the granular product encapsulated in a geopolymer matrix. The FBSR product is composed primarily of an insoluble sodium aluminosilicate matrix with the dominant phases being feldspathoid minerals mostly nepheline, sodalite, and nosean. The PUF test method allows for the accelerated weathering of materials, including radioactive waste forms, under hydraulically unsaturated conditions, thus mimicking the open-flow and transport properties that most likely will be present at the IDF. The experiments show a trend of decreasing tracer release as a function of time for several of the elements released from the material including Na, Si, Al, and Cs. However, some of the elements, notably I and Re, show a steady release throughout the yearlong test. This result suggests that the release of these minerals from the sodalite cage occurs at a different rate compared with the dissolution of the predominant nepheline phase.

Durability testing↗

Solid oxide fuel cell power plant having a bootstrap start-up system

The bootstrap start-up system (42) achieves an efficient start-up of the power plant (10) that minimizes formation of soot within a reformed hydrogen rich fuel. A burner (48) receives un-reformed fuel directly from the fuel supply (30) and combusts the fuel to heat cathode air which then heats an electrolyte (24) within the fuel cell (12). A dilute hydrogen forming gas (68) cycles through a sealed heat-cycling loop (66) to transfer heat and generated steam from an anode side (32) of the electrolyte (24) through fuel processing system (36) components (38, 40) and back to an anode flow field (26) until fuel processing system components (38, 40) achieve predetermined optimal temperatures and steam content. Then, the heat-cycling loop (66) is unsealed and the un-reformed fuel is admitted into the fuel processing system (36) and anode flow (26) field to commence ordinary operation of the power plant (10).

30 DIRECT ENERGY CONVERSION↗

Report on Year-4 of Water NSTF Matrix Testing: Facility Maintenance and Accident Testing

Under support from the Department of Energy (DOE) and the Office of Advanced Reactor Technologies (ART), a large-scale test facility has been constructed at Argonne National Laboratory to generate NQA-1 qualified validation data for passive decay heat removal systems in advanced reactors. The Natural convection Shutdown heat removal Test Facility (NSTF) reflects key features of a ½ scale, water-based, Reactor Cavity Cooling System (RCCS) and is intended to study the behavior, bound performance, and ultimately guide design decisions for passive decay heat removal systems for advanced reactors. In addition to the experimental activities detailed in this report, a supportive computational modeling effort is on-going which has been demonstrated to significantly strengthen the experimental program while also improving accuracy of the computer models. Together these create a mutually beneficial relationship integral to meeting the overall program objective of examining the heat removal performance of the RCCS concept. This report serves as a summary of maintenance and experimental activities during the program’s fourth year of water-based operation. A planned six-month maintenance period began in August 2021, during which major inspections, repairs, cleaning, and installation of new instrumentation and data acquisition hardware were conducted. Most significantly, two heaters that faulted during Year-3 were repaired, allowing the facility to resume use of the full heated section area and full range of available electric power. The remainder of the year consisted of eight months of test operations, during which the facility logged 211 hours of active heating across one bake-out (following the maintenance period) and seven matrix tests; five classifieds as Accepted per NQA-1, one as Trending, and one as Failed. Testing began by performing two repeat cases to confirm expected facility response and behavior during both single- and two-phase flow conditions, ensuring no changes were introduced during the maintenance period that might have altered the thermal-hydraulic characteristics of the facility. In continuation of the power parametric series initiated in previous years, a high-power test case was then performed examining heat removal performance at a decay heat load equivalent to 2.4 MWt, full-scale, a level exceeding maximum design targets. Additional testing then introduced various blockage scenarios along the network piping, examining the effects of partial and complete blockages of the flow paths on the system behavior and heat removal performance. A study of static boiling tests directed at understanding the geysering two-phase instability was also conducted. The loop was filled only to the bottom of the tank outlet, creating an open loop configuration that prevents any natural circulation flow from occurring, and the heaters were powered on until the facility reached saturation conditions. Following, a series of quasi-steady-state conditions were introduced by adjusting the inventory level in the adiabatic chimney piping at decreasingly lower elevations above the heated region. A strong correlation of geysering characteristics and loop level was observed, with flow and temperature excursions decreasing in intensity, but increasing in frequency, as the fill were reduced to lower elevations along the chimney piping. Once the level fell very low in the chimney, at points near the top of the heated section, the system reached a stable state of continuous boiling without any occurrence of geysering eruptions. A final significant testing accomplishment this year was successful completion of an “accident scenario” test, whose operating conditions were based on a prototypic decay heat curve provided by Framatome and scaled for the NSTF. This test began by establishing steady-state, single-phase “normal operation” conditions, before simulating an accident trip where the availability of active cooling systems was lost. Loop temperatures gradually increased until reaching saturation and subsequent two-phase boiling flow. Over the course of an extended operational period along the defined decay heat curve, steam boil-off caused gradual but continued depletion of liquid inventory until reaching a critically low level causing flow stagnation and cessation of natural circulation heat removal. At this point, after nearly 72 hours of continuous operation, a cold refill was performed to replenish the system inventory and allow the facility to re-establish closed loop natural circulation flow and return to a safe operational state.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗