Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “statistical analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Method of resource-limited device and device class identification using system and function call tracing techniques, performance, and statistical analysis

Methods for cyber physical systems device classification are provided. A method can include receiving system and function calls and parameters and a device performance index from an unknown CPS device and a device performance index of similar class of CPS devices, calculating an autocorrelation value between different realizations of the system and function calls and parameters of the known CPS device, determining whether the autocorrelation value is greater than a threshold amount, and storing the system and function calls and parameters and the device performance characteristics of the known CPS device in the database. A method can also include calculating a correlation between system and function calls and parameters of an unknown CPS device and known CPS devices classes included in the database, as well as determining whether the maximum correlation is also greater than a threshold amount.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Statistical Analysis in Support of Control Fuel Temperature for the Advanced Gas Reactor Experiments

There are four completed tests among a series of Advanced Gas Reactor (AGR) irradiation experiments that are being conducted within the Advanced Reactor Technologies (ART) Fuel Development and Qualification Program. The main objectives of the fuel experimental campaigns are to provide the necessary data on fuel performance to support fuel process development, qualify a fuel design and fabrication process for normal operation and hypothetical accident conditions, and support development and validation of fuel performance and fission product transport models and codes.1 Since this tristructural isotropic fuel is qualified to be used in high temperature gas-cooled reactors (HTGRs), it is essential that the testing conditions of fuel irradiations are designed to mimic those in the conceptual gas reactors. As a result, temperatures of the AGR test fuel have to be maintained within a specified range that is typical of the HTGRs. In each AGR capsule, the test fuel temperature is controlled independently using a variable fraction neon and helium gas mixture that fills the gap volume for each capsule. The temperature as measured by a thermocouple (TC) terminated in the graphite holder (which houses fuel compacts) is used as a feedback for the gas flow controllers. Direct temperature measurement for fuel compacts is not possible because contact between a TC head and fuel particle could lead to undesirable failures. Therefore, an ABAQUS based finite element thermal model was created to predict the daily average fuel temperatures during the entire irradiation period.2,3 It is well-known that extended exposure to neutron irradiation and high temperatures leads to changes in geometries of fuel compacts and graphite holder, which result in changes of the gas gap leading to a change in the relationship between TC and fuel temperatures. In addition, TCs are also expected to drift and sometimes fail under irradiation conditions. These facts make maintaining test fuel temperature within a specified range challenging. This paper describes how the regression analysis methods are used in conjunction of calculated fuel temperatures from early irradiation periods (when irradiation effect is relatively small) to effectively control fuel temperature for the remaining irradiation, when irradiation effect became profound. This is particularly important in the event of all TCs in a capsule fail.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Maximizing MWh: A statistical analysis of the performance of utility-scale photovoltaic projects in the United States

Despite significant cost declines utility-scale solar projects have to perform well over their lifetime in order to return profits in a low-PPA environment of under $50/MWh. Using multivariate regression analysis this paper examines the 2014 Net Capacity Factors for 128 utility-scale projects that came online before the end of 2013 and explores the impact (in decreasing order of importance) of global horizontal irradiance, tracking technology, inverter loading ratios and project vintage plus three other interactive variables on performance. The model complies with the assumptions of OLS regressions and explains 93% of the observed NCF variation.

Bolinger, M↗

Statistical Analysis in Support of Fuel Temperature Control in the Advanced Gas Reactor Experiments

There are four completed tests among a series of Advanced Gas Reactor (AGR) irradiation experiments that are being conducted within the Advanced Reactor Technologies (ART) Fuel Development and Qualification Program. The main objectives of the fuel experimental campaigns are to provide the necessary data on fuel performance to support fuel process development, qualify a fuel design and fabrication process for normal operation and hypothetical accident conditions, and support development and validation of fuel performance and fission product transport models and codes. Since this tri-structural isotropic fuel is qualified to be used in high temperature gas-cooled reactors (HTGRs), it is essential that the testing conditions of fuel irradiations are designed to mimic those in the conceptual gas reactors. As a result, temperatures of the AGR test fuel have to be maintained within a specified range that is typical of the HTGRs. In each AGR capsule, the test fuel temperature is controlled independently using a variable fraction neon and helium gas mixture that fills the gap volume for each capsule. The temperature as measured by a thermocouple (TC) terminated in the graphite holder (which houses fuel compacts) is used as a feedback for the gas flow controllers. Direct temperature measurement for fuel compacts is not possible because contact between a TC head and fuel particle could lead to undesirable failures. Therefore, an ABAQUS-based finite element thermal model was created to predict the daily average fuel temperatures during the entire irradiation period. It is well-known that extended exposure to neutron irradiation and high temperatures leads to changes in geometries of fuel compacts and graphite holder, which results in changes of the gas gap, leading to a change in the relationship between TC and fuel temperatures. In addition, TCs are expected to drift and sometimes fail under irradiation conditions. These facts make maintaining test fuel temperature within a specified range challenging. This paper describes how the regression analysis methods are used in conjunction with calculated fuel temperatures from early irradiation periods (when the irradiation effect is relatively small) to effectively control fuel temperature for the remaining irradiation (when the irradiation effect became profound). This is particularly important in the event when all TCs in a capsule fail.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

STATISTICAL ANALYSIS OF IN-SERVICE ULTRASONIC INSPECTION DATA OF WASTE TANKS AT THE SAVANNAH RIVER Site-25021

Liquid radioactive waste has been stored in large, underground carbon steel tanks of 4.92-million-liter capacity at the United States Department of Energy's Savannah River Site (SRS) in Aiken, South Carolina since the 1950s. The In-service inspection of the Savannah River Site High Level Waste tanks will be reviewed as well as Ultrasonic testing (UT) for detecting for general wall thinning, pitting and interface attack through accessible regions of the tanks. In-service inspection [1] of the Savannah River Site (SRS) High Level Waste (HLW) tanks is an essential element of a comprehensive structural integrity program. Inspection confirmed the effectiveness of chemistry and temperature controls used to preclude localized and general corrosion of the tanks. Ultrasonic testing is used to detect general wall thinning, pitting and interface attack, as well as vertically oriented cracks through inspection of a 21.59 cm (8.5-in.) wide strip extending over the accessible height of the primary tank wall.

Harris, Stephen P.↗