Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “state estimations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

U.S. Distribution Transformer Demand Phase III - Key Drivers and Managing Demand [Slides]

This presentation demonstrates a significant analysis, on forecasting the demand for distribution transformers. The analysis is conducted for the United States, estimating the initial in-service capacity of these assets, and forecasting demand for these assets through 2050 with several sensitivities conducted. It examines not only demand for these assets, but importantly, how utility planning practices can impact the demand for theses assets in time. Under load growth scenarios, whether utilities practice like-for-like replacement strategies as failures occur, or whether they practice proactive up-sizing, anticipating electric load growth, can have major impacts on future demand. It also examines several other growth factors, such as the increasing demand for step-up transformers, which share many of the same characteristics as distribution transformers, and the demand for specific transformers for large project growth from data centers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid Topology Discovery Algorithm Evaluation of Suitability for Utility Deployment (CRADA 606 Final Report)

This work presents the results of a field-informed demonstration aimed at evaluating the practical suitability of a topology discovery algorithm for utility environments. We demonstrated an algorithm that uses a graph-theory-informed state estimation approach for model selection. In collaboration with Survalent and Peninsula Light Co., the algorithm was applied to real feeder models and field measurements from supervisory control and data acquisition (SCADA) and advanced metering infrastructure (AMI) systems to identify the operational topology of a power distribution system. The demonstration assessed the algorithm’s performance under realistic data conditions, including sparse and noisy measurements, and examined its ability to identify the most likely network configurations. The results confirmed that the approach can effectively narrow down feasible topologies, providing operators with improved situational awareness of network status. Key lessons learned emphasize the need for systematic data validation and strategic sensor placement to enhance observability. These insights inform future deployment strategies and guide refinements for broader adoption in utility operations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dynamic Performance Enhancement for Nonlinear Stochastic Systems Using RBF Driven Nonlinear Compensation with Extended Kalman Filter

In this paper, a novel hybrid control method is proposed to enhance the control performance of the PI based control system for a class of nonlinear and non-Gaussian stochastic dynamic processes with unmeasurable states. Firstly, to enhance the tracking performance of the PI controller where the PI parameters are fixed in many actual control systems, the compensative signal is formed using the extended Kalman filter(EKF) based state estimator and driven by the radial basis function (RBF) neural network based compensator. In addition, the weights of RBF is trained to minimize the entropy criterion of tracking error as the process is subjected to non-Gaussian disturbances. Meanwhile, since the precise statistical property of noises is hard to obtain for many industrial processes, the kernel density estimation (KDE) technique is employed in this paper to estimate the entropy. The convergence of RBF network is discussed and the stability of the resulted closed-loop hybrid control system is analyzed in mean square sense. Finally, a numerical example and a practical system testing are given to illustrate the effectiveness of the proposed control method.

stochastic systems, PI Controller, Entropy, Extend↗

Digitalization of an experimental electrochemical reactor via the smart manufacturing innovation platform

The exponential increase in data produced over the last two decades has revolutionized the way we collect, store, process, analyze, model, and interpret information to improve profitability. Manufacturing is no exception. How- ever, Smart Manufacturing, the digital practice, organization, workforce, and infrastructure transformation for collection and deployment of data and models at scale and at all levels of manufacturing, is a complex, costly, and labor-intensive journey that is still seeing slow adoption. The Clean Energy Smart Manufacturing Innovation Institute (CESMII), a national Manufacturing USA public-private partnership sponsored by the Department of Energy, is addressing this scaled use of data and modeling in manufacturing. CESMII has focused on how to col- lect and use operating data for numerous applications that improve productivity, precision, and performance of manufacturing operations from factory floor to supply chain using process simulation, predictive analytics, mon- itoring and control, and real-time optimization. Because contextualized data are key, CESMII has developed the Smart Manufacturing Innovation Platform (SMIP) to lower the barriers to the data that are needed to accelerate data-based model building, improve data visualization, and more quickly gain insights. Reusable, standards-based ways of doing data collection, ingestion, and contextualization are particularly important for scaling access and use of data. The SMIP uses a standards-based definition and construct for reusable information models called an SM Profile. When an SM Profile is used in conjunction with the SMIP, the SMIP ensures the availability of contextualized, operational data for model building. The present work demonstrates Smart Manufacturing and the application of the SMIP for building several data-centered models for the operation and control of an ex- perimental electrochemical reactor that reduces carbon dioxide (CO 2 ) gas to valuable liquid and gas chemicals, such as alcohols, olefins, and syngas. We describe how the SMIP plays a central role in more effective model building and we demonstrate how the electochemical reactor can be controlled and optimized for the desired products. Use of the SMIP involves the transmission of real-time sensor measurements to a cloud resource so that the operating data are available to all model building experts. The data collection and transmission process is fully automated to greatly reduce the need for manual manipulation of the data. Data-driven machine learning models are used for advanced real-time state estimation, real-time optimization, and model-based feedback control for the reactor. The application models are implemented as a system to monitor the data flow and control the electrochemical reactor with a single visualization interface. SM Profiles are used to demonstrate reusability of the information models for the reactor and the instrumentation. The application packages, algorithms, and user interfaces developed are cast as Docker images in a library to facilitate reusability of the application models.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Model-free control for frequency response support in microgrids utilizing wind turbines

Islanded microgrids integrated with renewable energy resources bring additional challenges to the primary frequency control due to their power-electronic interfaced generations. Developing an efficient control strategy for inertia emulation and frequency response support of microgrids is becoming an important issue. Wind turbine dynamics, however, will degrade the emulated inertial and primary responses with most traditional control strategies. On the other hand, compensation methods often require the knowledge of system models at the design stage and state estimation for feedback once deployed online. To overcome these challenges, this paper explores a model-free control (MFC) strategy to emulate the desired inertia and support the frequency response of a diesel-wind microgrid system. Additionally, the proposed MFC strategy utilizes a model reference concept to obtain guaranteed inertial response and improve the frequency response of microgrids. This work considers different control strategies with different operating points. The proposed controller is implemented and verified using the modified 33-bus full nonlinear model of the three-phase diesel-wind system in Simulink. Simulation results demonstrate the improved frequency response by precisely emulating the desired inertia using the MFC strategy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Can Biogeochemical Tracer Observations Constrain Southern Ocean Diapycnal Mixing Rates?

Abstract Direct observations of background diapycnal mixing rates in the Southern Ocean (SO) are limited spatially and temporally, making the choice of an appropriate value to parameterize this mixing in Earth system models a challenge. However, the deployment of Argo floats throughout the SO has provided an extensive range of observations of both physical and biogeochemical parameters. We use an ocean state estimate run with various background diapycnal mixing coefficients to assess if biogeochemical tracer observations can be used to better constrain SO diapycnal mixing rates. We find that vertical tracer distributions in the SO are highly sensitive to the rate of background diapycnal mixing and can provide an upper limit on background mixing rates. This demonstrates the importance of biogeochemical tracer observations throughout the full depth of the water column to validate ocean models.

Ellison, Elizabeth [The Australian National Univer↗

Systematic planning of moving target defence for maximising detection effectiveness against false data injection attacks in smart grid

Abstract Moving target defence (MTD) has been gaining traction to thwart false data injection attacks against state estimation (SE) in the power grid. MTD actively perturbs the reactance of transmission lines equipped with distributed flexible AC transmission system (D‐FACTS) devices to falsify the attacker's knowledge about the system configuration. However, the existing literature has not systematically studied what influences the detection effectiveness of MTD and how it can be improved based on the topology analysis. These problems are tackled here from the perspective of an MTD plan in which the D‐FACTS placement is determined. We first exploit the relation between the rank of the composite matrix and the detecting effectiveness. Then, we rigorously derive upper and lower bounds on the attack detecting probability of MTDs with a given rank of the composite matrix. Furthermore, we analyse existing planning methods and highlight the importance of bus coverage by D‐FACTS devices. To improve the detection effectiveness, we propose a novel graph theory–based planning algorithm to retain the maximum rank of the composite matrix while covering all necessary buses. Comparative results on multiple systems show the high detecting effectiveness of the proposed algorithm in both DC‐ and AC‐SE.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Man‐in‐the‐middle attacks and defence in a power system cyber‐physical testbed

Abstract Man‐in‐The‐Middle (MiTM) attacks present numerous threats to a smart grid. In a MiTM attack, an intruder embeds itself within a conversation between two devices to either eavesdrop or impersonate one of the devices, making it appear to be a normal exchange of information. Thus, the intruder can perform false data injection (FDI) and false command injection (FCI) attacks that can compromise power system operations, such as state estimation, economic dispatch, and automatic generation control (AGC). Very few researchers have focused on MiTM methods that are difficult to detect within a smart grid. To address this, we are designing and implementing multi‐stage MiTM intrusions in an emulation‐based cyber‐physical power system testbed against a large‐scale synthetic grid model to demonstrate how such attacks can cause physical contingencies such as misguided operation and false measurements. MiTM intrusions create FCI, FDI, and replay attacks in this synthetic power grid. This work enables stakeholders to defend against these stealthy attacks, and we present detection mechanisms that are developed using multiple alerts from intrusion detection systems and network monitoring tools. Our contribution will enable other smart grid security researchers and industry to develop further detection mechanisms for inconspicuous MiTM attacks.

Wlazlo, Patrick↗

Cross-Layered Distributed Data-Driven Framework for Enhanced Smart Grid Cyber-Physical Security

Smart Grid (SG) research and development has drawn much attention from academia, industry and government due to the great impact it will have on society, economics and the environment. Securing the SG is a considerably significant challenge due the increased dependency on communication networks to assist in physical process control, exposing them to various cyber-threats. In addition to attacks that change measurement values using False Data Injection (FDI) techniques, attacks on the communication network may disrupt the power system's real-time operation by intercepting messages, or by flooding the communication channels with unnecessary data. Addressing these attacks requires a cross-layer approach. In this paper a cross-layered strategy is presented, called Cross-Layer Ensemble CorrDet with Adaptive Statistics(CECD-AS), which integrates the detection of faulty SG measurement data as well as inconsistent network inter-arrival times and transmission delays for more reliable and accurate anomaly detection and attack interpretation. Numerical results show that CECD-AS can detect multiple False Data Injections, Denial of Service (DoS) and Man In The Middle (MITM) attacks with a high F1-score compared to current approaches that only use SG measurement data for detection such as the traditional physics-based State Estimation, Ensemble CorrDet with Adaptive Statistics strategy and other machine learning classification-based detection schemes.

cyber-physical security↗

Bayesian filtering for model predictive control of stochastic gene expression in single cells

This study describes a method for controlling the production of protein in individual cells using stochastic models of gene expression. By combining modern microscopy platforms with optogenetic gene expression, experimentalists are able to accurately apply light to individual cells, which can induce protein production. Here we use a finite state projection based stochastic model of gene expression, along with Bayesian state estimation to control protein copy numbers within individual cells. We compare this method to previous methods that use population based approaches. We also demonstrate the ability of this control strategy to ameliorate discrepancies between the predictions of a deterministic model and stochastic switching system.

59 BASIC BIOLOGICAL SCIENCES↗

Cell degradation quantification—a performance metric-based approach

A safe and reliable battery operation needs effective diagnostic tools. A quantitative failure analysis (FA) to enable cell qualification and quantify its effectiveness for reliable and safe operation of rechargeable Li batteries (RLB) is shown here. The method can identify and quantify potential failure based on the state of charge (SOC) under any operating conditions. A precise and accurate electrochemical analytic diagnosis (eCAD) of 14 rechargeable Li || NMC622 cells of the same build are used as an example. The FA by eCAD can quantitatively decipher good, bad and ugly cells in cycle aging. The cell qualification is based on thermodynamic SOC, not experimental conditions. The method provides a quantitative failure mode and effect analysis (FMEA) to reveal diverse “dead Li” formation that affects the reversibility of the Li anode and charge retention in the cell. This cell qualification method highlights the potential to improve cell quality for safe operation, with strong implications for early fault detection, FA, risk mitigation, state estimation and life prediction for reliable and safe RLB operations

25 ENERGY STORAGE↗

Vibrational response and temperature of shock-compressed Pt: In situ extended x-ray absorption fine structure measurements to 325 GPa

Single pulse (~100 ps duration) extended x-ray absorption fine structure (EXAFS) measurements were obtained in laser shocked Pt to examine atomic vibrational properties and to determine temperatures for shock pressures from 72-325 GPa. Pt x-ray absorption spectra were recorded while a planar shock wave was propagating through the Pt sample. The absorption spectrum corresponding to the shocked Pt was obtained by subtracting the ambient Pt contribution from the measured absorption spectrum. Fits to the shocked state EXAFS data provided Pt lattice parameters consistent with the known Pt Hugoniot and the mean squared relative displacements (MSRDs) for nearest neighbor Pt atoms. Pt temperatures in the shocked state, estimated from the MSRDs using the correlated Debye model and correlated Einstein models, were consistent with both the Hugoniot temperatures calculated by integration along the Hugoniot and with the Hugoniot temperatures from published first-principles calculations. However, the agreement between the Hugoniot temperatures from EXAFS measurements and the calculated Hugoniot temperatures is not as good above 200 GPa, likely due to anharmonic effects. Furthermore, the present results demonstrate that single-pulse synchrotron EXAFS measurements in laser-shocked solids are useful for quantitative temperature determination and for examination of vibrational properties, including anharmonicity, at extreme pressure-temperature conditions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Proactive Stochastic Framework for Cyber-Physical Power Systems Security

This paper presents a framework for cyberphysical power systems security in which defensive action is proactive, striving to mitigate the harm from strategic cyber attacks before they occur. The prospect is formulated in a previously-studied context of state estimation via the Kalman filter under false data injection attacks. Assuming a cognitive attacker who is both advanced and persistent, the proactive defense rests upon stochastically influencing the sensors, Phasor Measurement Units, such that subsequent falsification attacks are countered. Examples are crafted to illustrate both the efficacy of the proactive approach in ideal situations and the practical challenges implied by non-ideal situations.

El Mezyani, Touria↗

A Novel Framework to Quantify Power Grid Resilience

The quantification of an operating power grid’s resilience is highly significant today, given its criticality as an enabler of other infrastructures, complexity, and the threat it faces due to a wide range of detrimental events, from extreme climate to cyber attacks. Currently, there exist no standardized definitions and metrics for measuring the resilience of an operating grid. In this paper, we introduce a novel resilience quantification framework and demonstrate a method to measure the flexibility towards topological/structural changes due to potential failures in the power grid to assess operational resilience. We start with the state estimation data from a large utility and use the graph analysis methods and power flow simulation tools to compute the identified resilience parameters.

Yoginath, Srikanth↗

Recursive Dynamic Compressive Sensing in Smart Distribution Systems

With a transition to a smarter grid, we are witnessing a significant growth in smart metering infrastructure and sensor deployment in the distribution system. The underlying communication infrastructure is stressed due to the large volume of data that is generated by the smart meters/sensors. Furthermore, real time operations such as state estimation and control are impaired due to the lack of reliable aggregation of the data. In this paper, we exploit the underlying sparsity in grid data to implement two recursive dynamic compressive sensing (CS) approaches-streaming modified weighted-`1 CS and Kalman filtered CS. These approaches aim to reconstruct the sparse signal using the current underdetermined measurements and the prior information about the sparse signal and its support set. Slow signal and support change is in distribution grid data is validated using Pecan Street data. Both the IEEE 34 node test feeder system and PecanStreet data are considered as two examples to validate the superior performance of the two recursive CS techniques relative to classic CS.

Karimi, Hazhar Sufi↗

Detection of Stealthy False Data Injection Attacks in Unobservable Distribution Networks

In this paper, a composite scheme is proposed for detecting stealthy data manipulation attacks on distribution system which is unobservable with standard least squares based state estimators. This technique has three stages where the process of data imputation, voltage phasor estimation and the bad data detection are carried out in a systematic manner. The proposed approach is then integrated with moving target defense strategies which perturbs the network parameters to reveal stealthy false data injection attacks. The proposed approach is tested is validated on a three-phase, unbalanced 37-node distribution system and its results are presented. It is shown that the proposed approach has the ability to accurately detect the presence of FDI attacks using limited measurements (i.e., the test system is unobservable).

Rajasekaran, James K.↗

A Graph Convolutional Network for Active Distribution System Anomaly Detection Considering Measurement Spatial-Temporal Correlations

The accuracy of distribution system state estimation may be significantly impacted by the existence of bad measure-ments and unexpected topology errors. This paper proposes a data-driven Graph Convolutional Network (GCN) for anomaly detection, including bad measurements and topology change events. Compared to many existing machine learning approaches, the proposed approach embeds both spatial-temporal measure-ment correlations, which allows us to detect and distinguish different anomalies. Numerical results carried out on the IEEE 37-node system demonstrate that the proposed-based method can obtain high accuracy in detecting bad data and topology changes as compared to other approaches, even in the presence of high PV penetrations.

active distribution system↗