Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Steps to achieving high-resolution NMR spectroscopy on solutions at GPa pressure

Recent theoretical advances and molecular-dynamic estimates of the dielectric constant of water have extended the HKF model for aqueous solution chemistry up to 6.0 gigapascals (GPa), which are conditions well beyond the capabilities of conventional NMR spectroscopy (Pan et al., 2013; Sverjensky et al., 2014, see also Wasserman and others, 1995). These developments provide strong motivation to design a simple NMR probe that allows experiments on solutions, at high resolution, to pressures of a few GPa (Pautler et al., 2014; Ochoa et al., 2015; 2016). Here we describe the performance of a compact NMR probe that can reach several GPa pressures. The probe is made by placing a solenoid microcoil inside of a standard piston-cylinder device used in solid-state physics. High pressures are achieved in the sample by applying force to a coaxial piston. Early designs of the probe, although useful, were limited in sample size to ~10-15μL. Here we describe modifications that allow greatly improved resolution and sensitivity, including 1H-1H NMR correlation spectroscopy, on solutions at 2.8 GPa pressure. Sample sizes can be expanded if, instead of a standard NMR spectrometer that is built around a superconducting magnet, one employs a magnetic-resonance imaging (MRI) system that is built around a permanent magnet. The MRI systems can apply larger magnetic field gradients than conventional spectrometers, and thus have more robust shimming capability, which is needed because of the juxtaposition of different alloys in the pressure cell. More importantly, these systems can have magnetic fields that are oriented perpendicular to the magnet bore, which allows rotation of the coil within the axis of the pressure cell to increase sample volumes and pressure. Sensitivity is improved by replacing the traditional, but reduced-volume, closed sample container mounted in the center of the NMR detection coil with an open NMR coil that dangles freely in solution, thus making the sample solution itself the pressure-transmission fluid. The efficacy of these modifications are demonstrated by measuring 1 H NMR spectra for ethyl alcohol and ethyl alcohol/methyl alcohol mixtures at pressures up to 2.8 GPa. As a result, further developments are discussed that will allow geochemists to acquire aqueous solution NMR spectra at higher 3-4 GPa pressures.

58 GEOSCIENCES↗

Gemini Planet Imager Spectroscopy of the Dusty Substellar Companion HD 206893 B

We present new near-infrared Gemini Planet Imager (GPI) spectroscopy of HD 206893 B, a substellar companion orbiting within the debris disk of its F5V star. The J, H, K1, and K2 spectra from GPI demonstrate the extraordinarily red colors of the object, confirming it as the reddest substellar object observed to date. The significant flux increase throughout the infrared presents a challenging atmosphere to model with existing grids. Best-fit values vary from 1200 to 1800 K for effective temperature and from 3.0 to 5.0 for log(g), depending on which individual wavelength band is fit and which model suite is applied. The extreme redness of the companion can be partially reconciled by invoking a high-altitude layer of submicron dust particles, similar to dereddening approaches applied to the peculiar red field L dwarf population. However, reconciling the HD 206893 B spectra with even those of the reddest low-gravity L dwarf spectra still requires the contribution of additional atmospheric dust, potentially due to the debris disk environment in which the companion resides. Orbit fitting from 4 yr of astrometric monitoring is consistent with a ∼30 yr period, an orbital inclination of 147°, and a semimajor axis of 10 au, well within the estimated disk inner radius of ∼50 au. As one of a very few substellar companions imaged interior to a circumstellar disk, the properties of this system offer important dynamical constraints on companion–disk interaction and provide a benchmark for substellar and planetary atmospheric study.

47 OTHER INSTRUMENTATION↗

Femtosecond Coherent Anti-Stokes Raman Spectroscopy (CARS) As Next Generation Nonlinear LIDAR Spectroscopy and Microscopy

Nonlinear spectroscopy using coherent anti-Stokes Raman scattering and femtosecond laser pulses has been successfully developed as powerful tools for chemical analysis and biological imaging. Recent developments show promising possibilities of incorporating CARS into LIDAR system for remote detection of molecular species in airborne particles. The corresponding theory is being developed to describe nonlinear scattering of a mesoscopic particle composed of complex molecules by laser pulses with arbitrary shape and spectral content. Microscopic many-body transform theory is used to compute the third order susceptibility for CARS in molecules with known absorption spectrum and vibrational modes. The theory is combined with an integral scattering formula and Mie-Lorentz formulae, giving a rigorous formalism which provides powerful numerical experimentation of CARS spectra, particularly on the variations with the laser parameters and the direction of detection.

74 ATOMIC AND MOLECULAR PHYSICS↗

Measurement of the Ionization State and Electron Temperature of Plasma during the Ablation Stage of a Wire-Array Z Pinch Using Absorption Spectroscopy

Wire-array plasmas were investigated in the nonradiative ablation stage via x-ray absorption spectroscopy. A laser-produced Sm plasma was used to backlight Al wire arrays. The Sm spectrum was simultaneously observed by two spectrometers: one recorded the unattenuated spectrum and the other the transmission spectrum with 1.45-1.55 keV K-shell absorption lines. Analysis of absorption spectra revealed electron temperature in the range of 10-30 eV and the presence of F-, O-, N- and C-like Al ions in the absorbing plasma. A comparison of this electron temperature with the postprocessed absorption spectra of a 2D MHD simulation yields results in general agreement with the data analysis.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Identification and Suppression of Point Defects in Bromide Perovskite Single Crystals Enabling Gamma‐Ray Spectroscopy

Abstract Methylammonium lead tribromide (MAPbBr 3 ) stands out as the most easily grown wide‐band‐gap metal halide perovskite. It is a promising semiconductor for room‐temperature gamma‐ray ( γ ‐ray) spectroscopic detectors, but no operational devices are realized. This can be largely attributed to a lack of understanding of point defects and their influence on detector performance. Here, through a combination of crystal growth design and defect characterization, including positron annihilation and impedance spectroscopy, the presence of specific point defects are identified and correlated to detector performance. Methylammonium (MA) vacancies, MA interstitials, and Pb vacancies are identified as the dominant charge‐trapping defects in MAPbBr 3 crystals, while Br vacancies caused doping. The addition of excess MABr reduces the MA and Br defects and so enables the detection of energy‐resolved γ ‐ray spectra using a MAPbBr 3 single‐crystal device. Interestingly, the addition of formamidinium (FA) cations, which converted to methylformamidinium (MFA) cations by reaction with MA + during crystal growth further reduced MA defects. This enabled an energy resolution of 3.9% for the 662 keV 137 Cs line using a low bias of 100 V. The work provides direction toward enabling further improvements in wide‐bandgap perovskite‐based device performance by reducing detrimental defects.

Ni, Zhenyi↗

The Stoichiometry of Synthetic Alunite as a Function of Hydrothermal Aging Investigated by Solid-State NMR Spectroscopy, Powder X-ray Diffraction and Infrared Spectroscopy

The stoichiometry of a series of synthetic alunite [nominally KAl3(SO4)2(OH)6] samples prepared by hydrothermal methods as a function of reaction time (1–31 days) has been investigated by powder X-ray diffraction, Fourier transform infrared spectroscopy as well as solid-state 1H and 27Al magic angle spinning (MAS) nuclear magnetic resonance (NMR) spectroscopy. The 1H MAS NMR spectra recorded at high magnetic field (21.1 T, 900 MHz) allowed for a clear separation of the different proton environments and for quantitative determination of the aluminum vacancy concentration as a function of time. The concentration of structural defects determined from, i.e., aluminum vacancies was reduced from 4 to 1 %, as the reaction time was extended from one to 31 days based on 1H MAS NMR. This was further supported by an increase of the unit cell parameter c, which is indicative of the relative concentration of potassium defects present, from 17.261(1) to 17.324(5) Å. Solid-state 27Al MAS NMR revealed a decrease in the defect concentration as a function of time and showed the presence of 7–10 % impurities in the samples.

Environmental Molecular Sciences Laboratory↗

On the relation between Marcus theory and ultrafast spectroscopy of solvation kinetics

The phenomena of solvent exchange control the process of solvating ions, protons, and charged molecules. Building upon our extension of Marcus’ philosophy of electron transfer, we provide a new perspective of ultrafast solvent exchange mechanism around ions measurable by two-dimensional infrared (2DIR) spectroscopy. In this theory, solvent rearrangement drives an ion-bound water to an activated state of higher coordination number, triggering ion-water separation that leads to the solvent-bound state of the water molecule. This ion-bound to solvent-bound transition rate for a BF4- water system is computed using ab initio molecular dynamics and Marcus theory, and is found to be in excellent agreement with the 2DIR measurement.

2DIR↗

Investigation of Sampling-Probe Distorted Temperature Fields with X-Ray Fluorescence Spectroscopy

Flame-sampling experiments, especially in conjunction with laminar low-pressure premixed flames, are routinely used in combustion chemistry studies to unravel the identities and quantities of key intermediates and their pathways. In many instances, however, an unambiguous interpretation of the experimental and modeling results is hampered by the uncertainties about the probe-induced, perturbed temperature profile. To overcome this limitation, two-dimensional perturbations of the temperature field caused by sampling probes with different geometries have been investigated using synchrotron-based X-ray fluorescence spectroscopy. In these experiments, which were performed at the 7-BM beamline of the Advanced Photon Source (APS) at the Argonne National Laboratory, a continuous beam of hard X-rays at 15 keV was used to excite krypton atoms that were added in a concentration of 5 vol.-% to the unburnt gas mixture and the resulting krypton fluorescence at 12.65 keV was subsequently collected. The highly spatially resolved signal was converted into the local flame temperature to obtain temperature fields at various burner-probe separations as functions of the distance to the burner surface and the radial distance from the centerline. Multiple measurements were performed with different probe geometries and because of the observed impact on the temperature profiles the results clearly revealed the need to specify the sampling probe design to enable quantitative and meaningful comparisons of modeling results with flame-sampled mole fraction data. (C) 2018 The Combustion Institute. Published by Elsevier Inc. All rights reserved.

Hansen, N.↗

Degradation-related defect level in weathered silicon heterojunction modules characterized by deep level transient spectroscopy

Commercial silicon heterojunction photovoltaic modules, known as amorphous-silicon-based heterojunction with intrinsic thin-film layer (HIT) modules, show average degradation after 10 years in the field. HIT modules weathered outdoors in Colorado and Florida display mostly uniform decreases in intensity when mapped with photoluminescence (PL) imaging compared to a control module. Flash-table-based current-voltage curves show that degradation is dominated by voltage loss. Samples are cored from each of the modules, and deep level transient spectroscopy (DLTS) detects three electron-trap defect states in all modules with activation energies of electron emission from the defects of 0.07, 0.16, and 0.50 eV. DLTS measurements on the weathered modules show an additional deep-level, electron-trap defect state with an activation energy of 0.51 eV and a trap density of approximately 10 12 cm –3 . The capture rate is measured using varying short filling pulse times, and the resulting capture cross section is estimated to be 1.1x10 –16 cm 2 . The development of the weathering-related defect level correlates to decreases in carrier lifetime, PL intensity, and module voltage. Various depths of the space charge region are probed with increments in applied reverse bias and filling-pulse bias. Furthermore, this DLTS depth profiling shows a trend of trap density increasing with less applied reverse bias, suggesting that the weathering-related defect increases carrier recombination toward the interface between the bulk silicon wafer and the junction-forming amorphous-silicon passivation layers.

14 SOLAR ENERGY↗

Measurement Error in Atomic-Scale Scanning Transmission Electron Microscopy—Energy-Dispersive X-Ray Spectroscopy (STEM-EDS) Mapping of a Model Oxide Interface

Abstract With the development of affordable aberration correctors, analytical scanning transmission electron microscopy (STEM) studies of complex interfaces can now be conducted at high spatial resolution at laboratories worldwide. Energy-dispersive X-ray spectroscopy (EDS) in particular has grown in popularity, as it enables elemental mapping over a wide range of ionization energies. However, the interpretation of atomically resolved data is greatly complicated by beam–sample interactions that are often overlooked by novice users. Here we describe the practical factors—namely, sample thickness and the choice of ionization edge—that affect the quantification of a model perovskite oxide interface. Our measurements of the same sample, in regions of different thickness, indicate that interface profiles can vary by as much as 2–5 unit cells, depending on the spectral feature. This finding is supported by multislice simulations, which reveal that on-axis maps of even perfectly abrupt interfaces exhibit significant delocalization. Quantification of thicker samples is further complicated by channeling to heavier sites across the interface, as well as an increased signal background. We show that extreme care must be taken to prepare samples to minimize channeling effects and argue that it may not be possible to extract atomically resolved information from many chemical maps.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗