Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spectral”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

An improved spectral calibration requirement for AVIRIS

The Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) measures spectra from 400 to 2500 nm through 224 contiguous spectral channels. These spectra are used to identify and determine the abundances of constituents of the earth's surface and atmosphere through the analysis of spectral molecular absorptions and scattering properties of materials. Spectral calibration of the AVIRIS is required to pursue these determinations, which are based on these fundamental spectral characteristics. The spectral calibration of AVIRIS consists of a description of the spectral response function for each of the 224 spectral channels. The spectral response function of AVIRIS channels was measured in the laboratory and shown to be Gaussian in shape. A subset of nine AVIRIS spectral channels is shown with channel centers at 10 nm intervals and channel shapes of Gaussian form with 10 nm full width and half maximum (FWHM). For AVIRIS the spectral calibration is described by the spectral center and FWHM of a Gaussian function for each channel. Uncertainty in the determination of the spectral center and FWHM for each channel are also reported. This paper presents results from an investigation of the sensitivity of AVIRIS-measured upwelling radiance to errors in spectral calibration. Based on this sensitivity analysis in conjunction with earlier work, an improved spectral calibration requirement for AVIRIS is proposed.

Green, Robert O.↗

Planck 2013 results. IX. HFI spectral response

The Planck High Frequency Instrument (HFI) spectral response was determined through a series of ground based tests conducted with the HFI focal plane in a cryogenic environment prior to launch. The main goal of the spectral transmission tests was to measure the relative spectral response (includingthe level of out-of-band signal rejection) of all HFI detectors to a known source of electromagnetic radiation individually. This was determined by measuring the interferometric output of a continuously scanned Fourier transform spectrometer with all HFI detectors. As there is no on-board spectrometer within HFI, the ground-based spectral response experiments provide the definitive data set for the relative spectral calibration of the HFI. Knowledge of the relative variations in the spectral response between HFI detectors allows for a more thorough analysis of the HFI data. The spectral response of the HFI is used in Planck data analysis and component separation, this includes extraction of CO emission observed within Planck bands, dust emission, Sunyaev-Zeldovich sources, and intensity to polarization leakage. The HFI spectral response data have also been used to provide unit conversion and colour correction analysis tools. While previous papers describe the pre-flight experiments conducted on the Planck HFI, this paper focusses on the analysis of the pre-flight spectral response measurements and the derivation of data products, e.g. band-average spectra, unit conversion coefficients, and colour correction coefficients, all with related uncertainties. Verifications of the HFI spectral response data are provided through comparisons with photometric HFI flight data. This validation includes use of HFI zodiacal emission observations to demonstrate out-of-band spectral signal rejection better than 10 8 . The accuracy of the HFI relative spectral response data is verified through comparison with complementary flight-data based unit conversion coefficients and colour correction coefficients. Furthermore, these coefficients include those based upon HFI observations of CO, dust, and Sunyaev-Zeldovich emission. General agreement is observed between the ground-based spectral characterization of HFI and corresponding in-flight observations, within the quoted uncertainty of each; explanations are provided for any discrepancies.

79 ASTRONOMY AND ASTROPHYSICS↗

Extension of the Time-Spectral Approach to Overset Solvers for Arbitrary Motion

Forced periodic flows arise in a broad range of aerodynamic applications such as rotorcraft, turbomachinery, and flapping wing configurations. Standard practice involves solving the unsteady flow equations forward in time until the initial transient exits the domain and a statistically stationary flow is achieved. It is often required to simulate through several periods to remove the initial transient making unsteady design optimization prohibitively expensive for most realistic problems. An effort to reduce the computational cost of these calculations led to the development of the Harmonic Balance method [1, 2] which capitalizes on the periodic nature of the solution. The approach exploits the fact that forced temporally periodic flow, while varying in the time domain, is invariant in the frequency domain. Expanding the temporal variation at each spatial node into a Fourier series transforms the unsteady governing equations into a steady set of equations in integer harmonics that can be tackled with the acceleration techniques afforded to steady-state flow solvers. Other similar approaches, such as the Nonlinear Frequency Domain [3,4,5], Reduced Frequency [6] and Time-Spectral [7, 8, 9] methods, were developed shortly thereafter. Additionally, adjoint-based optimization techniques can be applied [10, 11] as well as frequency-adaptive methods [12, 13, 14] to provide even more flexibility to the method. The Fourier temporal basis functions imply spectral convergence as the number of harmonic modes, and correspondingly number of time samples, N, is increased. Some elect to solve the equations in the frequency domain directly, while others choose to transform the equations back into the time domain to simplify the process of adding this capability to existing solvers, but each harnesses the underlying steady solution in the frequency domain. These temporal projection methods will herein be collectively referred to as Time-Spectral methods. Time-Spectral methods have demonstrated marked success in reducing the computational costs associated with simulating periodic forced flows, but have yet to be fully applied to overset or Cartesian solvers for arbitrary motion with dynamic hole-cutting. Overset and Cartesian grid methodologies are versatile techniques capable of handling complex geometry configurations in practical engineering applications, and the combination of the Time-Spectral approach with this general capability potentially provides an enabling new design and analysis tool. In an arbitrary moving-body scenario for these approaches, a Lagrangian body moves through a fixed Eulerian mesh and mesh points in the Eulerian mesh interior to the solid body are removed (cut or blanked), leaving a hole in the Eulerian mesh. During the dynamic motion some gridpoints in the domain are blanked and do not have a complete set of time-samples preventing a direct implementation of the Time-Spectral method. Murman[6] demonstrated the Time-Spectral approach for a Cartesian solver with a rigid domain motion, wherein the hole cutting remains constant. Similarly, Custer et al. [15, 16] used the NASA overset OVERFLOW solver and limited the amount of relative motion to ensure static hole-cutting and interpolation. Recently, Mavriplis and Mundis[17] demonstrated a qualitative method for applying the Time-Spectral approach to an unstructured overset solver for arbitrary motion. The goal of the current work is to develop a robust and general method for handling arbitrary motion with the Time-Spectral approach within an overset or Cartesian mesh method, while still approaching the spectral convergence rate of the original Time-Spectral approach. The viscous OVERFLOW solver will be augmented with the new Time-Spectral algorithm and the capability of the method for benchmark problems in rotorcraft and turbomachinery will be demonstrated. This abstract begins with a brief synopsis of the Time-Spectral approach for overset grids and provides details of e current approach to allow for arbitrary motion. Model problem results in one and two dimensions are included to demonstrate the viability of the method and the convergence properties. Section IV briefly outlines the implementation into the OVERFLOW solver, and the abstract closes with a description of the benchmark test cases which will be included in the final paper.

Leffell, Joshua Isaac↗

Initial On-Orbit Spectral Calibration of the PACE Ocean Color Instrument

The NASA Plankton, Aerosol, Cloud, and ocean Ecosystem (PACE) mission Project Science Team has used Ocean Color Instrument (OCI) measurements of Fraunhofer lines in spectra of sunlight reflected by the solar diffuser and measurements of atmospheric absorption bands in cloudtop and ocean spectra to characterize the spectral calibration of OCI on orbit. Multiple lines have been analyzed for both the ultraviolet to visible (UVVIS, 340−607 nm) and visible to near-infrared (VISNIR, 597−897 nm) grating spectrographs. The spectrographs yield hyperspectral observations with 5 nm bandwidths and 0.625 nm sampling intervals. The on-orbit observations have been compared with the prelaunch spectral calibration of OCI performed by the Goddard Laser for Absolute Measurement of Radiance (GLAMR) during thermal vacuum testing to track any changes in the calibration since launch. The calibration analyzed the line positions and strengths for the Fraunhofer lines for each spectrograph by comparing the solar spectra measured by OCI with predicted solar spectra derived from the solar reference spectrum and the BRDF of the solar diffuser, convolved with the OCI relative spectral responses. The calibration also compared the line positions of the atmospheric absorption bands with the model transmissions used by the PACE Project. The line position comparisons show that the root mean square (RMS) spectral difference between the measured and predicted spectra is 0.15 nm, the average spectral shift is 0.062 nm, and the residual spectral dispersion over the wavelength range of the Fraunhofer lines is 0.17 nm. All three estimates of the spectral accuracy of OCI meet the instrument functional requirement of a spectral accuracy of 0.5 nm and are well within the 0.625 nm sampling interval of the data. The line strength comparisons between measured and predicted spectra are essentially the same. These results show that the spectral calibration of OCI on orbit has not drifted since the prelaunch calibration of OCI by GLAMR and that the on-orbit spectral calibration of OCI is stable over time. These results also provide a baseline for monitoring the future spectral performance of OCI on orbit.

Radiometric Calibration↗

The influence of the spectral emissivity of flat-plate calibrators on the calibration of IR thermometers

Flat Calibrators (FC) are an option for calibration of infrared thermometers (IT) with a fixed large target. FCs are neither blackbodies, nor gray-bodies; their spectral emissivity is lower than one and depends on wavelength. Nevertheless they are used as gray-bodies with a nominal emissivity value. FCs can be calibrated radiometrically using as reference a calibrated IR thermometer (RT). If an FC will be used to calibrate ITs that work in the same spectral range as the RT then its calibration is straightforward: the actual FC spectral emissivity is not required. This result is valid for any given fixed emissivity assessed to the FC. On the other hand, when the RT working spectral range does not match with that of the ITs to be calibrated with the FC then it is required to know the FC spectral emissivity as part of the calibration process. For this purpose, at CENAM, we developed an experimental setup to measure spectral emissivity in the infrared spectral range, based on a Fourier transform infrared spectrometer. Not all laboratories have emissivity measurement capability in the appropriate wavelength and temperature ranges to obtain the spectral emissivity. Thus, we present an estimation of the error introduced when the spectral range of the RT used to calibrate an FC and the spectral ranges of the ITs to be calibrated with the FC do not match. Some examples are developed for the cases when RT and IT spectral ranges are [8,13] μm and [8,14] μm respectively.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An Accurate Method for Correcting Spectral Convolution Errors in Intercalibration of Broadband and Hyperspectral Sensors

The intercalibration between a broadband and a hyperspectral satellite Earth observation system requires the convolution of the hyperspectral data with the spectral response functions (SRFs) of the corresponding broadband channels. There are two potential issues associated with the convolution procedure. First, the finite resolution of a hyperspectral spectrum, that is, the deviation from the highly accurate line-by-line monochromatic radiances, will contribute to convolution errors. The magnitude of the errors depends on the spectral resolution and the SRF shape of the hyperspectral instrument. This type of the convolution error has not been well recognized, and there is a lack of corresponding discussion in most published papers. Although it is small as compared with the instrument accuracy of existing hyperspectral sounders, the error is deemed to be signicant when it is compared with the stringent calibration requirement imposed by future climate missions like the Climate Absolute Radiance and Refractivity Observatory (CLARREO). Second, some broadband channels are insufficiently covered by the hyperspectral data, causing spectral gaps that lead to convolution errors. Although several methods have been developed to fill the spectral gaps and hence compensate for the second type of convolution error, the correction accuracy may still need improvement especially when a large spectral gap needs to be lled. This paper presents a methodology to accurately quantify and compensate for both types of convolution errors. This methodology utilizes the available hyperspectral information to correct the scene-dependent convolution errors due to either the limited spectral resolution or spectral gaps. We use simulations to characterize the intercalibration errors between the Moderate resolution Imaging Spectroradiometer (MODIS) and current operational infrared sounders. We demonstrate that convolution errors can be effectively removed to meet the highly accurate intersatellite calibration requirement proposed by the Climate Absolute Radiance and Refractivity Observatory. Our methodology is also validated using real satellite data for the intercalibration between Aqua MODIS and Aqua Atmospheric Infrared Sounders (AIRS). Our study demonstrates that the accurate characterization and correction for the convolution errors greatly reduces the scene-dependent and spectrally dependent errors, being critical to the consistency check between Infrared Atmospheric Sounding Interferometer (IASI) and AIRS using the double-difference method. The convolution correction also facilitates the evaluation for other intercalibration errors (e.g., the drift of MODIS SRFs). Our derived SRF shift values from MODIS-AIRS (after convolution error corrections) and from MODIS-IASI intercalibration are consistent with each other. We further extend the methodology to study the calibration of a broadband channel which is either completely or largely uncovered bya hyperspectral measurement.The large spectral gap-filling methodology is validated by demonstrating the accurate prediction of the MODIS radiance of band 29 using the Cross-track Infrared Sounder spectra, with the real IASI spectral data being used as the reference.

Correction Method↗

Quantifying the influences of spectral resolution on uncertainty in leaf trait estimates through a Bayesian approach to RTM inversion

The remote monitoring of plant canopies is critically needed for understanding of terrestrial ecosystem mechanics and biodiversity as well as capturing the short- to long-term responses of vegetation to disturbance and climate change. A variety of orbital, sub-orbital, and field instruments have been used to retrieve optical spectral signals and to study different vegetation properties such as plant biochemistry, nutrient cycling, physiology, water status, and stress. Radiative transfer models (RTMs) provide a mechanistic link between vegetation properties and observed spectral features, and RTM spectral inversion is a useful framework for estimating these properties from spectral data. However, existing approaches to RTM spectral inversion are typically limited by the inability to characterize uncertainty in parameter estimates. Here, we introduce a Bayesian algorithm for the spectral inversion of the PROSPECT 5 leaf RTM that is distinct from past approaches in two important ways: First, the algorithm only uses reflectance and does not require transmittance observations, which have been plagued by a variety of measurement and equipment challenges. Second, the output is not a point estimate for each parameter but rather the joint probability distribution that includes estimates of parameter uncertainties and covariance structure. We validated our inversion approach using a database of leaf spectra together with measurements of equivalent water thickness (EWT) and leaf dry mass per unit area (LMA). The parameters estimated by our inversion were able to accurately reproduce the observed reflectance (RMSE VIS = 0.0063, RMSE NIR-SWIR = 0.0098) and transmittance (RMSE VIS = 0.0404, RMSE NIR-SWIR = 0.0551) for both broadleaved and conifer species. Inversion estimates of EWT and LMA for broadleaved species agreed well with direct measurements (CV EWT = 18.8%, CV LMA = 24.5%), while estimates for conifer species were less accurate (CV EWT = 53.2%, CV LMA = 63.3%). To examine the influence of spectral resolution on parameter uncertainty, we simulated leaf reflectance as observed by ten common remote sensing platforms with varying spectral configurations and performed a Bayesian inversion on the resulting spectra. We found that full-range hyperspectral platforms were able to retrieve all parameters accurately and precisely, while the parameter estimates of multispectral platforms were much less precise and prone to bias at high and low values. We also observed that variations in the width and location of spectral bands influenced the shape of the covariance structure of parameter estimates. Lastly, our Bayesian spectral inversion provides a powerful and versatile framework for future RTM development and single- and multi-instrumental remote sensing of vegetation.

54 ENVIRONMENTAL SCIENCES↗

High dynamic range measurement of spectral responsivity and linearity of a radiation thermometer using a super-continuum laser and LEDs

To realize the temperature scale above the freezing point of silver according to the definition of ITS-90, the dynamic range of the spectral responsivity is one of the most important factors which limit its uncertainty. When the residual spectral response at both side bands of a spectral band is not negligible, a significant uncertainty can be caused by a low dynamic range of the spectral responsivity measurement. In general, incandescent lamps are used to measure the spectral responsivity and the linearity. The dynamic range of the spectral responsivity measurement is often limited by a trade-off with the desired spectral resolution, which is less than 6 decades. Nonlinearity is another limiting fact of uncertainties of the temperature scale. Tungsten lamps have disadvantage in the nonlinearity measurements in terms of adjustability of radiance level and spectral selectivity. We report spectral responsivity measurements of which the measurable dynamic range is enhanced 50 times after replacing a QTH lamp with a super continuum laser. We also present a spectrally selected linearity measurement over a wide dynamic range using high-brightness light emitting diode arrays to observe a slight saturation of linearity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of the Clear-Sky Spectral Error for Radiometer Classification in ISO 9060: Preprint

A recent update of the ISO 9060 standard for the classification of solar radiometers introduces the use of the clear sky spectral error. The spectral error is the change in responsivity that may occur when the spectral distribution of the incident solar radiation differs from the spectral distribution present at the time of calibration. Spectral errors may occur if the radiometer does not have a completely uniform spectral responsivity. This use of the clear sky spectral error is a significant change compared to the previous version of the 9060 standard as now not only thermopile radiometers, but also photodiode radiometers are covered by the standard. We explain the method used to derive the spectral error and present spectral errors for several radiometers of different technologies. The results demonstrate that the new method is helpful to classify radiometers, distinguishing between different radiometer types and excluding inappropriate instruments from the classification as pyranometers and pyrheliometers. We recommend that the method is also used for WMO's radiometer classification which up to our knowledge is currently not fulfilled by any field pyrheliometer and many pyranometers on the market due to its demanding requirements for the spectral responsivity.

14 SOLAR ENERGY↗

Coso Geothermal Spectral Library for Rocks and Minerals

An integrated open mineral spectral library designed to enhance the utility and precision of mineral spectral data for geothermal exploration, developed from a reliable and comprehensive digital dataset for seamless sharing by integrating field data, the USGS spectral library, and pertinent information obtained from Coso geothermal field (Coso) in California. The ASD FieldSpec portable spectrometer was utilized for collecting spectral data, which was subsequently analyzed using the THOR Material Identification tool in ENVI, The Spectral Geologist (TSG) software by CSIRO, and the Fully Constrained Linear Spectral Unmixing algorithm (FCLSU) in MATLAB. Scanning Electron Microscopy (SEM) with a mineralogy-analyzing function was employed to assess the mineral composition of samples, ensuring precise mineralogical analysis. A portable X-ray fluorescence (pXRF) spectrometer was also utilized to gather information on elemental enrichment. A framework for developing spectra data and establishing spectral libraries for various geological cases was proposed within this study. The characteristic spectra of six alteration minerals - alunite, chalcedony, epidote, hematite, kaolinite, and opal - were acquired from Coso samples. The spectral library for the Coso alteration minerals was introduced for further application in academic study or industrial exploration. To browse the Coso Geothermal Spectral data and related figures from spreadsheets: #1 Unzip and store the following items in the same folder. 'Contact Probe Data.zip', 'Sample Photos.zip', and 'Coso spectra of higher-certainity minerals.xlsx'. #2 Open 'Coso spectra of higher-certainity minerals.xlsx'. The hyperlinks in the spreadsheet lead to the folders or figures of: spectra .asd file, spectra ASC II file, spectra plots, and sample photos. The spectra data is raw data without splice correction. Spectra .asd files require particular software to open. (These cannot be opened in GIS software such as ArcGIS.) Spectra ASC II files can be opened in a text editor or spread sheet program.

15 GEOTHERMAL ENERGY↗

The eROSITA Final Equatorial-Depth Survey (eFEDS): The AGN catalog and its X-ray spectral properties

The eROSITA Final Equatorial Depth Survey (eFEDS), observed with eROSITA ahead of its planned 4-yr all-sky survey, is the largest contiguous-field X-ray survey at present. It yielded a large sample of X-ray sources with very rich multiband photometric and spectroscopic coverage. We present here the eFEDS active galactic nuclei (AGN) catalog and the eROSITA X-ray spectral properties of the eFEDS sources. Using a Bayesian method, we performed a systematic X-ray spectral analysis for all the eFEDS sources. We adopted multiple spectral models, including single-component power-law or hot-plasma models and double-component models of a power law plus soft excess. We investigated the capacity of eROSITA X-ray spectra for constraining AGN spectral shapes through a detailed analysis of the posterior parameter probability distribution functions. Hierarchical Bayesian modeling was used to recover the spectral parameter distribution of the sample. The source fluxes and luminosities were measured from the posterior of the spectral fitting. The eFEDS AGN catalog (22 079 sources) comprises ~80% of the eFEDS point sources. Despite a large number of faint sources, our spectral fitting provides reasonable measurements of spectral shapes and intrinsic luminosities for a majority of the sources. Because of sample selection bias, this AGN catalog is dominated by X-ray unobscured sources, with an obscured (logN H > 21.5) fraction of 8%; the power-law emission of the hot corona is also relatively soft, with a typical slope of 2.0. For type-I AGN, the X-ray emission is well correlated with the UV emission with the usual anticorrelation between the X-ray to UV spectral slope α OX and the UV luminosity. The X-ray spectral properties measured with various models are presented for all the eFEDS sources.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-F-J-210: A Preliminary Study On the Dosimetric Impact of Detector Based Spectral Ct On Proton Therapy Treatment Planning

Purpose: To compare the difference in Hounsfield unit-relative stopping power and evaluate the dosimetric impact of spectral vs. conventional CT on proton therapy treatment plans. Method: The Philips prototype (IQon), a detector-based, spectral CT system (spectral) was used to scan calibration and Rando phantoms. Data were reconstructed with and without energy decomposition to produce monoenergetic 70 keV, 140 keV, and the Zeff images. Relative stopping power (RSP) in the head and lung regions were evaluated as a function of HU in order to compare spectral and conventional CT. Treatment plans for the Rando phantom were also generated and used to produce DVHs of fictitious target volume and organ-at-risk contoured on the head and lung. Results: Agreement of the Zeff of the tissue-substitute materials determined using spectral CT agrees to within 1 to 5% of the Zeff of the known phantom composition. The discrepancy is primarily attributed to non-uniformity in the phantom. Differences between the HU-RSP curves obtained using spectral and conventional CT were small except for in the lung curve at HU>1000. The large difference in planned doses using Spectral vs. conventional CT occurred in a low-dose brain region (1.7mm between the locations of the 100 cGy lines and 3 mm for 50 cGy lines). Conclusion: Conventionally, a single HU-RSP from CT scanner is used in proton treatment planning. Spectral CT allows site-specific HU-RSP for each patient. Spectral and conventional HU-RSP may result in different distributions as shown here. Additional study is required to evaluate the impact of Spectral CT in proton treatment planning. This study is part of a research agreement between Philips and University Hospitals/Case Medical Center.

60 APPLIED LIFE SCIENCES↗

INVESTIGATING THE CONNECTION BETWEEN QUASI-PERIODIC OSCILLATIONS AND SPECTRAL COMPONENTS WITH NuSTAR DATA OF GRS 1915+105

Low-frequency quasi-periodic oscillations (QPOs) are commonly observed during the hard states of black hole binaries. Several studies have established various observational/empirical correlations between spectral parameters and QPO properties, indicating a close link between the two. However, the exact mechanism of generation of QPOs is not yet well understood. In this paper, we present our attempts to comprehend the connection between the spectral components and the low-frequency QPO (LFQPO) observed in GRS 1915+105 using the data from NuSTAR. Detailed spectral modeling as well as the presence of the LFQPO and its energy dependence during this observation have been reported by Miller et al. and Zhang et al., respectively. We investigate the compatibility of the spectral model and the energy dependence of the QPO by simulating light curves in various energy bands for small variation of the spectral parameters. The basic concept here is to establish the connection, if any, between the QPO and the variation of either a spectral component or a specific parameter, which in turn can shed some light on the origin of the QPO. We begin with the best-fit spectral model of Miller et al. and simulate the light curve by varying the spectral parameters at frequencies close to the observed QPO frequency in order to generate the simulated QPO. Furthermore we simulate similar light curves in various energy bands in order to reproduce the observed energy dependence of the rms amplitude of the QPO. We find that the observed trend of increasing rms amplitude with energy can be reproduced qualitatively if the spectral index is assumed to be varying with the phases of the QPO. Variation of any other spectral parameter does not reproduce the observed energy dependence.

79 ASTRONOMY AND ASTROPHYSICS↗

Spectral Methods for Computational Fluid Dynamics

As a tool for large-scale computations in fluid dynamics, spectral methods were prophesized in 1944, born in 1954, virtually buried in the mid-1960's, resurrected in 1969, evangalized in the 1970's, and catholicized in the 1980's. The use of spectral methods for meteorological problems was proposed by Blinova in 1944 and the first numerical computations were conducted by Silberman (1954). By the early 1960's computers had achieved sufficient power to permit calculations with hundreds of degrees of freedom. For problems of this size the traditional way of computing the nonlinear terms in spectral methods was expensive compared with finite-difference methods. Consequently, spectral methods fell out of favor. The expense of computing nonlinear terms remained a severe drawback until Orszag (1969) and Eliasen, Machenauer, and Rasmussen (1970) developed the transform methods that still form the backbone of many large-scale spectral computations. The original proselytes of spectral methods were meteorologists involved in global weather modeling and fluid dynamicists investigating isotropic turbulence. The converts who were inspired by the successes of these pioneers remained, for the most part, confined to these and closely related fields throughout the 1970's. During that decade spectral methods appeared to be well-suited only for problems governed by ordinary diSerential eqllations or by partial differential equations with periodic boundary conditions. And, of course, the solution itself needed to be smooth. Some of the obstacles to wider application of spectral methods were: (1) poor resolution of discontinuous solutions; (2) inefficient implementation of implicit methods; and (3) drastic geometric constraints. All of these barriers have undergone some erosion during the 1980's, particularly the latter two. As a result, the applicability and appeal of spectral methods for computational fluid dynamics has broadened considerably. The motivation for the use of spectral methods in numerical calculations stems from the attractive approximation properties of orthogonal polynomial expansions.

Zang, T. A.↗

Spectral Dimensionality and Scale of Urban Radiance

Characterization of urban radiance and reflectance is important for understanding the effects of solar energy flux on the urban environment as well as for satellite mapping of urban settlement patterns. Spectral mixture analyses of Landsat and Ikonos imagery suggest that the urban radiance field can very often be described with combinations of three or four spectral endmembers. Dimensionality estimates of Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) radiance measurements of urban areas reveal the existence of 30 to 60 spectral dimensions. The extent to which broadband imagery collected by operational satellites can represent the higher dimensional mixing space is a function of both the spatial and spectral resolution of the sensor. AVIRIS imagery offers the spatial and spectral resolution necessary to investigate the scale dependence of the spectral dimensionality. Dimensionality estimates derived from Minimum Noise Fraction (MNF) eigenvalue distributions show a distinct scale dependence for AVIRIS radiance measurements of Milpitas, California. Apparent dimensionality diminishes from almost 40 to less than 10 spectral dimensions between scales of 8000 m and 300 m. The 10 to 30 m scale of most features in urban mosaics results in substantial spectral mixing at the 20 m scale of high altitude AVIRIS pixels. Much of the variance at pixel scales is therefore likely to result from actual differences in surface reflectance at pixel scales. Spatial smoothing and spectral subsampling of AVIRIS spectra both result in substantial loss of information and reduction of apparent dimensionality, but the primary spectral endmembers in all cases are analogous to those found in global analyses of Landsat and Ikonos imagery of other urban areas.

Small, Christopher↗

Results and Lessons from a Decade of Terra MODIS On-Orbit Spectral Characterization

Since its launch in December 1999, the NASA EOS Terra MODIS has successfully operated for more than a decade. MODIS makes observations in 36 spectral bands from visible (VIS) to longwave infrared (LWIR) and at three nadir spatial resolutions: 250m (2 bands), 500m (5 bands), and 1km (29 bands). In addition to its on-board calibrators designed for the radiometric calibration, MODIS was built with a unique device, called the spectro-radiometric calibration assembly (SRCA). It can be configured in three different modes: radiometric, spatial, and spectral. When it is operated in the spectral modes, the SRCA can monitor changes in Sensor spectral performance for the VIS and near-infrared (NIR) spectral bands. For more than 10 years, the SRCA operation has continued to provide valuable information for MODIS on-orbit spectral performance. This paper briefly describes SRCA on-orbit operation and calibration activities; it presents decade-long spectral characterization results for Terra MODIS VIS and NIR spectral bands in terms of chances in their center wavelengths (CW) and bandwidths (BW). It is shown that the SRCA on-orbit wavelength calibration capability remains satisfactory. For most spectral bands, the changes in CW and BW are less than 0.5 and 1 nm, respectively. Results and lessons from Terra MODIS on-orbit spectral characterization have and will continue to benefit its successor, Aqua MODIS, and other future missions.

Xiong, X.↗

Directional and Spectral Irradiance in Ocean Models: Effects on Simulated Global Phytoplankton, Nutrients, and Primary Production

The importance of including directional and spectral light in simulations of ocean radiative transfer was investigated using a coupled biogeochemical-circulation-radiative model of the global oceans. The effort focused on phytoplankton abundances, nutrient concentrations and vertically-integrated net primary production. The importance was approached by sequentially removing directional (i.e., direct vs. diffuse) and spectral irradiance and comparing results of the above variables to a fully directionally and spectrally-resolved model. In each case the total irradiance was kept constant; it was only the pathways and spectral nature that were changed. Assuming all irradiance was diffuse had negligible effect on global ocean primary production. Global nitrate and total chlorophyll concentrations declined by about 20% each. The largest changes occurred in the tropics and sub-tropics rather than the high latitudes, where most of the irradiance is already diffuse. Disregarding spectral irradiance had effects that depended upon the choice of attenuation wavelength. The wavelength closest to the spectrally-resolved model, 500 nm, produced lower nitrate (19%) and chlorophyll (8%) and higher primary production (2%) than the spectral model. Phytoplankton relative abundances were very sensitive to the choice of non-spectral wavelength transmittance. The combined effects of neglecting both directional and spectral irradiance exacerbated the differences, despite using attenuation at 500 nm. Global nitrate decreased 33% and chlorophyll decreased 24%. Changes in phytoplankton community structure were considerable, representing a change from chlorophytes to cyanobacteria and coccolithophores. This suggested a shift in community function, from light-limitation to nutrient limitation: lower demands for nutrients from cyanobacteria and coccolithophores favored them over the more nutrient-demanding chlorophytes. Although diatoms have the highest nutrient demands in the model, their relative abundances were generally unaffected because they only prosper in nutrient-rich regions, such as the high latitudes and upwelling regions, which showed the fewest effects from the changes in radiative simulations. The results showed that including directional and spectral irradiance when simulating the ocean light field can be important for ocean biology, but the magnitude varies with variables and regions. The quantitative results are intended to assist ocean modelers when considering improved irradiance representations relative to other processes or variables associated with the issues of interest.

Phytoplankton↗

Assessment of the Accuracy and Consistency of Cloud Property Retrievals from Passive Radiometers with Varying Spectral Information

Over the past few decades, space-based passive radiometers have been used to study the spatial distribution of clouds and some of their basic properties. Modern radiometers have significantly higher spatial resolution and collect more spectral information (i.e., have more spectral bands) than early instruments, and these advances have allowed researchers to characterize cloud physical and microphysical properties with greater detail. There is significant interest in utilizing as much of the existing satellite record as possible to study global and regional changes in cloud occurrence and distribution as well as the associated changes in reflected shortwave and outgoing longwave fluxes. Cloud property retrieval algorithms such as the NASA Satellite Cloud Optical and Radiative Property System (SatCORPS) have traditionally utilized as much spectral information as possible in order to maximize the accuracy of the retrievals. However, changes to the retrieval algorithm over time in order to take advantage of progressively more spectral information results in inconsistencies in cloud properties which in turn results in inconsistencies with products derived from these properties. It is not possible to implement modern state-of-the-art algorithms to earlier instruments which lack diverse spectral information, but many instruments since the early 2000s generally have approximately similar spectral bands in the visible (~0.65 microns), longwave infrared (~11 microns), and in many cases, the midwave infrared (~3.8 microns) and water vapor absorption (~6.7 microns), portions of the electromagnetic spectrum. Different versions of SatCORPS have been implemented with either the full set of spectral information collected by imagers such as GOES-16 and MODIS or with a reduced set of spectral bands in order to be more consistent with past imagers that lack such diverse spectral information. This study uses independent cloud property retrievals from the Cloud-Aerosol Lidar with Orthogonal Polarization (CALIOP) to assess the accuracy of the retrievals (e.g., cloud fraction, thermodynamic phase, altitude) from the different retrieval methods and to demonstrate the advantages and disadvantages of using a reduced set of common spectral bands in order to achieve temporal and spatial consistency across different instruments.

Christopher R. Yost↗